941 resultados para Safety data recording
Resumo:
This study was carried out to detect differences in locomotion and feeding behavior in lame (group L; n = 41; gait score ≥ 2.5) and non-lame (group C; n = 12; gait score ≤ 2) multiparous Holstein cows in a cross-sectional study design. A model for automatic lameness detection was created, using data from accelerometers attached to the hind limbs and noseband sensors attached to the head. Each cow's gait was videotaped and scored on a 5-point scale before and after a period of 3 consecutive days of behavioral data recording. The mean value of 3 independent experienced observers was taken as a definite gait score and considered to be the gold standard. For statistical analysis, data from the noseband sensor and one of two accelerometers per cow (randomly selected) of 2 out of 3 randomly selected days was used. For comparison between group L and group C, the T-test, the Aspin-Welch Test and the Wilcoxon Test were used. The sensitivity and specificity for lameness detection was determined with logistic regression and ROC-analysis. Group L compared to group C had significantly lower eating and ruminating time, fewer eating chews, ruminating chews and ruminating boluses, longer lying time and lying bout duration, lower standing time, fewer standing and walking bouts, fewer, slower and shorter strides and a lower walking speed. The model considering the number of standing bouts and walking speed was the best predictor of cows being lame with a sensitivity of 90.2% and specificity of 91.7%. Sensitivity and specificity of the lameness detection model were considered to be very high, even without the use of halter data. It was concluded that under the conditions of the study farm, accelerometer data were suitable for accurately distinguishing between lame and non-lame dairy cows, even in cases of slight lameness with a gait score of 2.5.
Resumo:
BACKGROUND: There is limited research concerning how small companies in particular, respond to health and safety messages. AIMS: To understand individuals' knowledge and beliefs about chemical risks and to compare these with those of experts. METHODS: The use of chromic acid in particular, and also other chemicals associated with chrome plating were studied. All chromium plating firms were based in the West Midlands. The methodology involved initial face to face interviews (n = 21) with chromium platers, structured questionnaires (n = 84) to test the prevalence of beliefs identified in the interviews, an expert questionnaire, and a workshop to discuss findings. The responses of platers were compared with those of occupational health and safety experts. RESULTS: Although chromium platers appeared to understand the short term adverse effects of the chemicals to which they are exposed, their understanding of long term, or chronic effects appeared to be incomplete. They had good knowledge of acute effects based primarily on experience. Platers were aware of the hazardous nature of the chemicals with which they work, but did not draw distinction between the terms "hazards" and "risks". They had difficulties articulating the effects of the chemicals and how exposure might occur; although it is inappropriate to equate this with lack of knowledge. A significant minority of platers displayed deficiencies in understanding key technical terms used in Safety Data Sheets. CONCLUSIONS: This study provides a method which can be used to gain some understanding of workers' knowledge and beliefs about risks that they are exposed to in the workplace. The study also identifies gaps between the platers' knowledge and beliefs and those of experts. New risk information needs to be designed which addresses the information needs of platers using language that they understand.
Resumo:
Inhaled human insulin (Exubera®) is a rapid-acting regular human insulin administered by oral inhalation before meals. It provides a non-invasive alternative to multiple subcutaneous injections for the treatment of hyperglycemia in adult patients with type 1 and type 2 diabetes. Compared with subcutaneous rapid-acting insulin analogs, Exubera provides equivalent HbA1c control. As a monotherapy or in combination with oral agents, Exubera also provides greater glycemic control than oral agents alone, at least in patients with high levels of HbA1c. Exubera demonstrates improved patient satisfaction compared with subcutaneous insulin or oral agents alone. When offered as a treatment option together with standard treatments in uncontrolled patients naive to insulin, Exubera increases acceptance of insulin therapy three-fold compared with patients offered standard regimens only. Exubera is well tolerated in comparison to subcutaneous insulin, with a similar incidence of mild to moderate hypoglycemia. Although cough is a common adverse effect early in therapy, this leads to treatment discontinuations in less than 1% of patients. Despite an increased incidence of insulin antibodies compared with subcutaneous administration, and a consistent but minor impact on pulmonary function, long-term safety data of up to 4 years continue to support the safety profile of Exubera.
Resumo:
BACKGROUND: Heavy menstrual bleeding (HMB) is a common problem, yet evidence to inform decisions about initial medical treatment is limited. OBJECTIVES: To assess the clinical effectiveness and cost-effectiveness of the levonorgestrel-releasing intrauterine system (LNG-IUS) (Mirena(®), Bayer) compared with usual medical treatment, with exploration of women's perspectives on treatment. DESIGN: A pragmatic, multicentre randomised trial with an economic evaluation and a longitudinal qualitative study. SETTING: Women who presented in primary care. PARTICIPANTS: A total of 571 women with HMB. A purposeful sample of 27 women who were randomised or ineligible owing to treatment preference participated in semistructured face-to-face interviews around 2 and 12 months after commencing treatment. INTERVENTIONS: LNG-IUS or usual medical treatment (tranexamic acid, mefenamic acid, combined oestrogen-progestogen or progesterone alone). Women could subsequently swap or cease their allocated treatment. OUTCOME MEASURES: The primary outcome was the patient-reported score on the Menorrhagia Multi-Attribute Scale (MMAS) assessed over a 2-year period and then again at 5 years. Secondary outcomes included general quality of life (QoL), sexual activity, surgical intervention and safety. Data were analysed using iterative constant comparison. A state transition model-based cost-utility analysis was undertaken alongside the randomised trial. Quality-adjusted life-years (QALYs) were derived from the European Quality of Life-5 Dimensions (EQ-5D) and the Short Form questionnaire-6 Dimensions (SF-6D). The intention-to-treat analyses were reported as cost per QALY gained. Uncertainty was explored by conducting both deterministic and probabilistic sensitivity analyses. RESULTS: The MMAS total scores improved significantly in both groups at all time points, but were significantly greater for the LNG-IUS than for usual treatment [mean difference over 2 years was 13.4 points, 95% confidence interval (CI) 9.9 to 16.9 points; p < 0.001]. However, this difference between groups was reduced and no longer significant by 5 years (mean difference in scores 3.9 points, 95% CI -0.6 to 8.3 points; p = 0.09). By 5 years, only 47% of women had a LNG-IUS in place and 15% were still taking usual medical treatment. Five-year surgery rates were low, at 20%, and were similar, irrespective of initial treatments. There were no significant differences in serious adverse events between groups. Using the EQ-5D, at 2 years, the relative cost-effectiveness of the LNG-IUS compared with usual medical treatment was £1600 per QALY, which by 5 years was reduced to £114 per QALY. Using the SF-6D, usual medical treatment dominates the LNG-IUS. The qualitative findings show that women's experiences and expectations of medical treatments for HMB vary considerably and change over time. Women had high expectations of a prompt effect from medical treatments. CONCLUSIONS: The LNG-IUS, compared with usual medical therapies, resulted in greater improvement over 2 years in women's assessments of the effect of HMB on their daily routine, including work, social and family life, and psychological and physical well-being. At 5 years, the differences were no longer significant. A similar low proportion of women required surgical intervention in both groups. The LNG-IUS is cost-effective in both the short and medium term, using the method generally recommended by the National Institute for Health and Care Excellence. Using the alternative measures to value QoL will have a considerable impact on cost-effectiveness decisions. It will be important to explore the clinical and health-care trajectories of the ECLIPSE (clinical effectiveness and cost-effectiveness of levonorgestrel-releasing intrauterine system in primary care against standard treatment for menorrhagia) trial participants to 10 years, by which time half of the cohort will have reached menopause. TRIAL REGISTRATION: Current Controlled Trials ISRCTN86566246. FUNDING: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 19, No. 88. See the NIHR Journals Library website for further project information.
Resumo:
Respiration and ammonium excretion rates at different oxygen partial pressure were measured for calanoid copepods and euphausiids from the Eastern Tropical South Pacific and the Eastern Tropical North Atlantic. All specimens used for experiments were caught in the upper 400 m of the water column and only animals appearing unharmed and fit were used for experiments. Specimens were sorted, identified and transferred into aquaria with filtered, well-oxygenated seawater immediately after the catch and maintained for 1 to 13 hours prior to physiological experiments at the respective experimental temperature. Maintenance and physiological experiments were conducted in darkness in temperature-controlled incubators at 11, 13 or 23 degree C (±1). Before and during experiments, animals were not fed. Respiration and ammonium excretion rate measurements (both in µmol h-1 gDW-1) at varying oxygen concentrations were conducted in 12 to 60 mL gas-tight glass bottles. These were equipped with oxygen microsensors (ø 3 mm, PreSens Precision Sensing GmbH, Regensburg, Germany) attached to the inner wall of the bottles to monitor oxygen concentrations non-invasively. Read-out of oxygen concentrations was conducted using multi-channel fiber optic oxygen transmitters (Oxy-4 and Oxy-10 mini, PreSens Precision Sensing GmbH, Regensburg, Germany) that were connected via optical fibers to the outside of the bottles directly above the oxygen microsensor spots. Measurements were started at pre-adjusted oxygen and carbon dioxide levels. For this, seawater stocks with adjusted pO2 and pCO2 were prepared by equilibrating 3 to 4 L of filtered (0.2 µm filter Whatman GFF filter) and UV - sterilized (Aqua Cristal UV C 5 Watt, JBL GmbH & Co. KG, Neuhofen, Germany) water with premixed gases (certified gas mixtures from Air Liquide) for 4 hours at the respective experimental temperature. pCO2 levels were chosen to mimic the environmental pCO2 in the ETSP OMZ or the ETNA OMZ. Experimental runs were conducted with 11 to 15 trial incubations (1 or 2 animals per incubation bottle and three different treatment levels) and three animal-free control incubations (one per experimental treatment). During each run, experimental treatments comprised 100% air saturation as well as one reduced air saturation level with and without CO2. Oxygen concentrations in the incubation bottles were recorded every 5 min using the fiber-optic microsensor system and data recording for respiration rate determination was started immediately after all animals were transferred. Respiration rates were calculated from the slope of oxygen decrease over selected time intervals. Chosen time intervals were 20 to 105 min long. No respiration rate was calculated for the first 20 to 60 min after animal transfer to avoid the impact of enhanced activity of the animal or changes in the bottle water temperature during initial handling on the respiration rates and oxygen readings. Respiration rates were obtained over a maximum of 16 hours incubation time and slopes were linear at normoxia to mild hypoxia. Respiration rates in animal-free control bottles were used to correct for microbial activity. These rates were < 2% of animal respiration rates at normoxia. Samples for the measurement of ammonium concentrations were taken after 2 to 10 hours incubation time. Ammonium concentration was determined fluorimetrically (Holmes et al., 1999). Ammonium excretion was calculated as the concentration difference between incubation and animal-free control bottles. Some specimens died during the respiration and excretion rate measurements, as indicated by a cessation of respiration. No excretion rate measurements were conducted in this case, but the oxygen level at which the animal died was noted.
Resumo:
If magnetism is universal in nature, magnetic materials are ubiquitous. A life without magnetism is unthinkable and a day without the influence of a magnetic material is unimaginable. They find innumerable applications in the form of many passive and active devices namely, compass, electric motor, generator, microphone, loud speaker, maglev train, magnetic resonance imaging, data recording and reading, hadron collider etc. The list is endless. Such is the influence of magnetism and magnetic materials in ones day to day life. With the advent of nanoscience and nanotechnology, along with the emergence of new areas/fields such as spintronics, multiferroics and magnetic refrigeration, the importance of magnetism is ever increasing and attracting the attention of researchers worldwide. The search for a fluid which exhibits magnetism has been on for quite some time. However nature has not bestowed us with a magnetic fluid and hence it has been the dream of many researchers to synthesize a magnetic fluid which is thought to revolutionize many applications based on magnetism. The discovery of a magnetic fluid by Jacob Rabinow in the year 1952 paved the way for a new branch of Physics/Engineering which later became magnetic fluids. This gave birth to a new class of material called magnetorheological materials. Magnetorheological materials are considered superior to electrorheological materials in that magnetorheology is a contactless operation and often inexpensive.Most of the studies in the past on magnetorheological materials were based on magnetic fluids. Recently the focus has been on the solid state analogue of magnetic fluids which are called Magnetorheological Elastomers (MREs). The very word magnetorheological elastomer implies that the rheological properties of these materials can be altered by the influence of an external applied magnetic field and this process is reversible. If the application of an external magnetic field modifies the viscosity of a magnetic fluid, the effect of external magnetic stimuli on a magnetorheological elastomer is in the modification of its stiffness. They are reversible too. Magnetorheological materials exhibit variable stiffness and find applications in adaptive structures of aerospace, automotive civil and electrical engineering applications. The major advantage of MRE is that the particles are not able to settle with time and hence there is no need of a vessel to hold it. The possibility of hazardous waste leakage is no more with a solid MRE. Moreover, the particles in a solid MRE will not affect the performance and durability of the equipment. Usually MR solids work only in the pre yield region while MR fluids, typically work in the post yield state. The application of an external magnetic field modifies the stiffness constant, shear modulus and loss modulus which are complex quantities. In viscoelastic materials a part of the input energy is stored and released during each cycle and a part is dissipated as heat. The storage modulus G′ represents the capacity of the material to store energy of deformation, which contribute to material stiffness. The loss modulusG′′ represents the ability of the material to dissipate the energy of deformation. Such materials can find applications in the form of adaptive vibration absorbers (ATVAs), stiffness tunable mounts and variable impedance surfaces. MREs are an important material for automobile giants and became the focus of this research for eventual automatic vibration control, sound isolation, brakes, clutches and suspension systems
Resumo:
Objective: Cost-effectiveness analysis of a 6-month treatment of apixaban (10 mg/12h, first 7 days; 5 mg/12h afterwards) for the treatment of the first event of venous thromboembolism (VTE) and prevention of recurrences, versus low-molecular-weight heparins/vitamin K antagonists treatment (LMWH/VKA). Material and methods: A lifetime Markov model with 13 health states was used for describing the course of the disease. Efficacy and safety data were obtained from AMPLIFY and AMPLIFY-EXT clinical trials; health outcomes were measured as life years gained (LYG) and quality-adjusted life years (QALY). The chosen perspective of this analysis has been the Spanish National Health System (NHS). Drugs, management of VTE and complications costs were obtained from several Spanish data sources (, 2014). A 3% discount rate was applied to health outcomes and costs. Univariate and probabilistic sensitivity analyses (SA) were performed in order to assess the robustness of the results. Results: Apixaban was the most effective therapy with 7.182 LYG and 5.865 QALY, versus 7.160 LYG and 5.838 QALYs with LMWH/VKA. Furthermore, apixaban had a lower total cost (13,374.70 vs 13,738.30). Probabilistic SA confirmed dominance of apixaban (led to better health outcomes with less associated costs) in 89% of the simulations. Conclusions: Apixaban 5 mg/12h versus LMWH/VKA was an efficient therapeutic strategy for the treatment and prevention of recurrences of VTE from the NHS perspective.
Resumo:
The aim has been to review the literature about the risk factors of hamstring injury in soccer from a biomechanical point of view. METHODOLOGY. Data bases of bibliography references were Medline, Scopus and SportDiscuss. RESULTS AND DISCUSSION. Many prospective studies have shown that the previous injury is the greatest risk factor of sustaining the injury. However the primary causes of the injury are unclear in soccer. A lack of hamstring flexibility has been one of the main injury risk factors with controversies on the results. Imbalance of isokinetic force is a risk factor but electrical coactivation of all muscles participating during knee flexion and extension are unknown in football. While the importance of lumbopelvic-hamstrings muscles synchronization during running seems to be crucial for understanding the risk of injury, no research has been developed in this topic in football. CONCLUSIONS. More research using new data recording procedures as Dynamic Scanners, Surface EMG, Inverse Dynamic Analysis are needed. The analysis of more specific movements as running, kicking or jumping is clearly required. Managers, coaches, physical trainers, physiotherapists, sport physicians and researchers should work together in order to improve the injury prevention and rehabilitation programs of football players. Key Words: sports biomechanics, soccer, hamstring injury, risk factors
Resumo:
Background Edoxaban, an oral factor Xa inhibitor, is non-inferior for prevention of stroke and systemic embolism in patients with atrial fibrillation and is associated with less bleeding than well controlled warfarin therapy. Few safety data about edoxaban in patients undergoing electrical cardioversion are available. Methods We did a multicentre, prospective, randomised, open-label, blinded-endpoint evaluation trial in 19 countries with 239 sites comparing edoxaban 60 mg per day with enoxaparin–warfarin in patients undergoing electrical cardioversion of non-valvular atrial fibrillation. The dose of edoxaban was reduced to 30 mg per day if one or more factors (creatinine clearance 15–50 mL/min, low bodyweight [≤60 kg], or concomitant use of P-glycoprotein inhibitors) were present. Block randomisation (block size four)—stratified by cardioversion approach (transoesophageal echocardiography [TEE] or not), anticoagulant experience, selected edoxaban dose, and region—was done through a voice-web system. The primary efficacy endpoint was a composite of stroke, systemic embolic event, myocardial infarction, and cardiovascular mortality, analysed by intention to treat. The primary safety endpoint was major and clinically relevant non-major (CRNM) bleeding in patients who received at least one dose of study drug. Follow-up was 28 days on study drug after cardioversion plus 30 days to assess safety. This trial is registered with ClinicalTrials.gov, number NCT02072434. Findings Between March 25, 2014, and Oct 28, 2015, 2199 patients were enrolled and randomly assigned to receive edoxaban (n=1095) or enoxaparin–warfarin (n=1104). The mean age was 64 years (SD 10·54) and mean CHA2DS2-VASc score was 2·6 (SD 1·4). Mean time in therapeutic range on warfarin was 70·8% (SD 27·4). The primary efficacy endpoint occurred in five (<1%) patients in the edoxaban group versus 11 (1%) in the enoxaparin–warfarin group (odds ratio [OR] 0·46, 95% CI 0·12–1·43). The primary safety endpoint occurred in 16 (1%) of 1067 patients given edoxaban versus 11 (1%) of 1082 patients given enoxaparin–warfarin (OR 1·48, 95% CI 0·64–3·55). The results were independent of the TEE-guided strategy and anticoagulation status. Interpretation ENSURE-AF is the largest prospective randomised clinical trial of anticoagulation for cardioversion of patients with non-valvular atrial fibrillation. Rates of major and CRNM bleeding and thromboembolism were low in the two treatment groups. Funding Daiichi Sankyo provided financial support for the study. © 2016 Elsevier Ltd
Resumo:
Background-Randomized trials that studied clinical outcomes after percutaneous coronary intervention (PCI) with bare metal stenting versus coronary artery bypass grafting (CABG) are underpowered to properly assess safety end points like death, stroke, and myocardial infarction. Pooling data from randomized controlled trials increases the statistical power and allows better assessment of the treatment effect in high-risk subgroups. Methods and Results-We performed a pooled analysis of 3051 patients in 4 randomized trials evaluating the relative safety and efficacy of PCI with stenting and CABG at 5 years for the treatment of multivessel coronary artery disease. The primary end point was the composite end point of death, stroke, or myocardial infarction. The secondary end point was the occurrence of major adverse cardiac and cerebrovascular accidents, death, stroke, myocardial infarction, and repeat revascularization. We tested for heterogeneities in treatment effect in patient subgroups. At 5 years, the cumulative incidence of death, myocardial infarction, and stroke was similar in patients randomized to PCI with stenting versus CABG (16.7% versus 16.9%, respectively; hazard ratio, 1.04, 95% confidence interval, 0.86 to 1.27; P = 0.69). Repeat revascularization, however, occurred significantly more frequently after PCI than CABG (29.0% versus 7.9%, respectively; hazard ratio, 0.23; 95% confidence interval, 0.18 to 0.29; P<0.001). Major adverse cardiac and cerebrovascular events were significantly higher in the PCI than the CABG group (39.2% versus 23.0%, respectively; hazard ratio, 0.53; 95% confidence interval, 0.45 to 0.61; P<0.001). No heterogeneity of treatment effect was found in the subgroups, including diabetic patients and those presenting with 3-vessel disease. Conclusions-In this pooled analysis of 4 randomized trials, PCI with stenting was associated with a long-term safety profile similar to that of CABG. However, as a result of persistently lower repeat revascularization rates in the CABG patients, overall major adverse cardiac and cerebrovascular event rates were significantly lower in the CABG group at 5 years.
Resumo:
Ship tracking systems allow Maritime Organizations that are concerned with the Safety at Sea to obtain information on the current location and route of merchant vessels. Thanks to Space technology in recent years the geographical coverage of the ship tracking platforms has increased significantly, from radar based near-shore traffic monitoring towards a worldwide picture of the maritime traffic situation. The long-range tracking systems currently in operations allow the storage of ship position data over many years: a valuable source of knowledge about the shipping routes between different ocean regions. The outcome of this Master project is a software prototype for the estimation of the most operated shipping route between any two geographical locations. The analysis is based on the historical ship positions acquired with long-range tracking systems. The proposed approach makes use of a Genetic Algorithm applied on a training set of relevant ship positions extracted from the long-term storage tracking database of the European Maritime Safety Agency (EMSA). The analysis of some representative shipping routes is presented and the quality of the results and their operational applications are assessed by a Maritime Safety expert.
Resumo:
BACKGROUND: Certolizumab pegol (Cimzia, CZP) was approved for the treatment of Crohn's disease (CD) patients in 2007 in Switzerland as the first country worldwide. This prospective phase IV study aimed to evaluate the efficacy and safety of CZP over 26 weeks in a multicenter cohort of practice-based patients. METHODS: Evaluation questionnaires at baseline, week 6, and week 26 were completed by gastroenterologists in hospitals and private practices. Adverse events were evaluated according to World Health Organization (WHO) guidelines. RESULTS: Sixty patients (38F/22M) were included; 53% had complicated disease (stricturing or penetrating), 45% had undergone prior CD-related surgery. All patients had prior exposure to systemic steroids, 96% to immunomodulators, 73% to infliximab, and 43% to adalimumab. A significant decrease of the Harvey-Bradshaw Index (HBI) was observed under CZP therapy (12.2 ± 4.9 at week 0 versus 6.3 ± 4.7 at week 6 and 6.7 ± 5.3 at week 26, both P < 0.001). Response and remission rates were 70% and 40% (week 6) and 67% and 36%, respectively (week 26). The complete perianal fistula closure rate was 36% at week 6 and 55% at week 26. The frequency of adverse drug reactions attributed to CZP was 5%. CZP was continued in 88% of patients beyond week 6 and in 67% beyond week 26. CONCLUSIONS: In a population of CD patients with predominantly complicated disease behavior, CZP proved to be effective in induction and maintenance of response and remission. This series provides the first evidence of CZP's effectiveness in perianal fistulizing CD in clinical practice.
Resumo:
The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although statistically significant responses could be detected in more than 50% of trials for every subject. Overall, we conclude that the proposed setup is well suited for simultaneous EEG-fMRI at 7T.
Resumo:
BACKGROUND: European Surveillance of Congenital Anomalies (EUROCAT) is a network of population-based congenital anomaly registries in Europe surveying more than 1 million births per year, or 25% of the births in the European Union. This paper describes the potential of the EUROCAT collaboration for pharmacoepidemiology and drug safety surveillance. METHODS: The 34 full members and 6 associate members of the EUROCAT network were sent a questionnaire about their data sources on drug exposure and on drug coding. Available data on drug exposure during the first trimester available in the central EUROCAT database for the years 1996-2000 was summarised for 15 out of 25 responding full members. RESULTS: Of the 40 registries, 29 returned questionnaires (25 full and 4 associate members). Four of these registries do not collect data on maternal drug use. Of the full members, 15 registries use the EUROCAT drug code, 4 use the international ATC drug code, 3 registries use another coding system and 7 use a combination of these coding systems. Obstetric records are the most frequently used sources of drug information for the registries, followed by interviews with the mother. Only one registry uses pharmacy data. Percentages of cases with drug exposure (excluding vitamins/minerals) varied from 4.4% to 26.0% among different registries. The categories of drugs recorded varied widely between registries. CONCLUSIONS: Practices vary widely between registries regarding recording drug exposure information. EUROCAT has the potential to be an effective collaborative framework to contribute to post-marketing drug surveillance in relation to teratogenic effects, but work is needed to implement ATC drug coding more widely, and to diversify the sources of information used to determine drug exposure in each registry.
Resumo:
Objective: The Agency for Healthcare Research and Quality (AHRQ) developed Patient Safety Indicators (PSIs) for use with ICD-9-CM data. Many countries have adopted ICD-10 for coding hospital diagnoses. We conducted this study to develop an internationally harmonized ICD-10 coding algorithm for the AHRQ PSIs. Methods: The AHRQ PSI Version 2.1 has been translated into ICD-10-AM (Australian Modification), and PSI Version 3.0a has been independently translated into ICD-10-GM (German Modification). We converted these two country-specific coding algorithms into ICD-10-WHO (World Health Organization version) and combined them to form one master list. Members of an international expert panel-including physicians, professional medical coders, disease classification specialists, health services researchers, epidemiologists, and users of the PSI-independently evaluated this master list and rated each code as either "include," "exclude," or "uncertain," following the AHRQ PSI definitions. After summarizing the independent rating results, we held a face-to-face meeting to discuss codes for which there was no unanimous consensus and newly proposed codes. A modified Delphi method was employed to generate a final ICD-10 WHO coding list. Results: Of 20 PSIs, 15 that were based mainly on diagnosis codes were selected for translation. At the meeting, panelists discussed 794 codes for which consensus had not been achieved and 2,541 additional codes that were proposed by individual panelists for consideration prior to the meeting. Three documents were generated: a PSI ICD-10-WHO version-coding list, a list of issues for consideration on certain AHRQ PSIs and ICD-9-CM codes, and a recommendation to WHO to improve specification of some disease classifications. Conclusion: An ICD-10-WHO PSI coding list has been developed and structured in a manner similar to the AHRQ manual. Although face validity of the list has been ensured through a rigorous expert panel assessment, its true validity and applicability should be assessed internationally.