977 resultados para SYNCHRONOUS GENERATOR
Resumo:
The objective of he article is to research the dynamic capacities developed and used by WEG in its internationalization process and to explain how these capacities help the company defends and supports competitive advantage. The article presents an exploratory study of the internationalization process of WEG in Argentina and China. This article has as analysis approach the dynamic capacities, contributes to the literature of international management in two aspects. First, it adds the analytical look of the internationalization based on dynamic capacities that are still well restricted. Second, when working the dynamic capacities as central element of the analysis of the internationalization process, it Proposes one framework of integrative analysis of the economic and behavioral theories that are used to explain the process of companies`-internationalization, although they are dealt independently and sometimes antagonistic way. The result shows as the dynamic capacities are articulated in the base of WEG in its process of internationalization for Argentina and the subsequent movement for China. The developed dynamic capacities in Argentina were acquired for the Brazilian headquarter and could have been applied in the process of internationalization for China. However, a more complex organizational structure cannot be identified where the inter-subsidiary relationships could share dynamic capacities as proposed in framework.
Resumo:
A 50-year-old woman presented with pancreatitis, fluctuant jaundice, weight loss, and abdominal pain. Contrast-enhanced computed tomography and abdominal ultrasound showed slight dilatation of the biliary tree and gallbladder without calculi. Endoscopy demonstrated a tumor protruding from the papilla of Vater. First endoscopically biopsy diagnosed no tumor, and a second biopsy diagnosed as papillary adenocarcinoma. The patient underwent duodenopancreatectomy. The specimen was fixed in formalin (10%). The tissue was processed routinely, and paraffin sections were stained with hematoxylin-eosin and periodic acid Schiff. Gross examination showed two tumors seen as prolapsed nodules growing isolated from the minor and major duodenal papillae measuring 1.5 and 1.0 cm, respectively, both covered by duodenal mucosa and the histologic study of both lesions demonstrated a moderately differentiated tubular adenocarcinoma, which invaded duodenal wall. After surgery, she is alive 24 months without evidence of recurrence.
Resumo:
Collision tumors consist of two independent but coexisting tumors. This uncommon situation might be easily mistaken for a composite tumor where one histogenetic event originates from two apparently distinct neoplasms. Colorectal collisions are particularly unusual; here, we report the exceedingly rare case of a 61-year-old man with malignant melanoma and adenocarcinoma colliding in the rectum. Collision tumors have an idiopathic pathophysiology and in fact ""accidental meeting"" is accepted by many authors. This article discusses the concepts about cancer development, which are overlooked by this hypothesis, another theory to explain that this rare occurrence involves microenvironment changes.
Resumo:
Evidence for nearly synchronous climate oscillations during the last deglaciation has been found throughout the Northern Hemisphere but few records are based on independent time scales of calendar years. We present a rare uranium-series dated oxygen-carbon isotope record for a speleothem from Tangshan Cave, China, which demonstrates that abrupt deglacial climatic oscillations from 16 800 to 10 500 yr BP are semi-synchronous with those found in Greenland ice core records. Relatively rapid shifts in speleothem oxygen isotope ratios demonstrate that the intensity of the East Asian monsoon switched in parallel with the abrupt transitions separating the Bolling-Allerod, Younger Dryas, and pre-Boreal climatic reversals. However, the dated isotopic transitions appear to have lasted longer. Our results demonstrate the dominant role of atmospheric teleconnections in the rapid propagation of deglacial climatic signals on a hemispheric scale, and highlight the importance of U-series dated speleothems in the timing and characterization of abrupt climate change. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Utiliza-se o método coordenada geradora Hartree-Fock para gerar bases Gaussianas adaptadas para os átomos de Li (Z=3) até Xe (Z=54). Neste método, integram-se as equações de Griffin-Hill-Wheeler-Hartree-Fock através da técnica de discretização integral. Comparam-se as funções de ondas geradas neste trabalho com as funções de ondas Roothaan-Hartree-Fock de Clementi e Roetti (1974) e com outros conjuntos de bases relatados na literatura. Para os átomos estudados aqui, os erros em nossas energias totais relativos aos limites numéricos Hartree-Fock são sempre menores que 7,426 milihartree.
Resumo:
The intensive use of semiconductor devices enabled the development of a repetitive high-voltage pulse-generator topology from the dc voltage-multiplier (VM) concept. The proposed circuit is based on an odd VM-type circuit, where a number of dc capacitors share a common connection with different voltage ratings in each one, and the output voltage comes from a single capacitor. Standard VM rectifier and coupling diodes are used for charging the energy-storing capacitors, from an ac power supply, and two additional on/off semiconductors in each stage, to switch from the typical charging VM mode to a pulse mode with the dc energy-storing capacitors connected in series with the load. Results from a 2-kV experimental prototype with three stages, delivering a 10-mu s pulse with a 5-kHz repetition rate into a resistive load, are discussed. Additionally, the proposed circuit is compared against the solid-state Marx generator topology for the same peak input and output voltages.
Resumo:
This paper presents a predictive optimal matrix converter controller for a flywheel energy storage system used as Dynamic Voltage Restorer (DVR). The flywheel energy storage device is based on a steel seamless tube mounted as a vertical axis flywheel to store kinetic energy. The motor/generator is a Permanent Magnet Synchronous Machine driven by the AC-AC Matrix Converter. The matrix control method uses a discrete-time model of the converter system to predict the expected values of the input and output currents for all the 27 possible vectors generated by the matrix converter. An optimal controller minimizes control errors using a weighted cost functional. The flywheel and control process was tested as a DVR to mitigate voltage sags and swells. Simulation results show that the DVR is able to compensate the critical load voltage without delays, voltage undershoots or overshoots, overcoming the input/output coupling of matrix converters.
Resumo:
Demand for power is growing every day, mainly due to emerging economies in countries such as China, Russia, India, and Brazil. During the last 50 years steam pressure and temperature in power plants have been continuously raised to improve thermal efficiency. Recent efforts to improve efficiency leads to the development of a new generation of heat recovery steam generator, where the Benson once-through technology is applied to improve the thermal efficiency. The main purpose of this paper is to analyze the mechanical behavior of a high pressure superheater manifold by applying finite element modeling and a finite element analysis with the objective of analyzing stress propagation, leading to the study of damage mechanism, e.g., uniaxial fatigue, uniaxial creep for life prediction. The objective of this paper is also to analyze the mechanical properties of the new high temperature resistant materials in the market such as 2Cr Bainitic steels (T/P23 and T/P24) and also the 9-12Cr Martensitic steels (T/P91, T/P92, E911, and P/T122). For this study the design rules for construction of power boilers to define the geometry of the HPSH manifold were applied.
Resumo:
This paper addresses the voltage droop compensation associated with long pulses generated by solid-stated based high-voltage Marx topologies. In particular a novel design scheme for voltage droop compensation in solid-state based bipolar Marx generators, using low-cost circuitry design and control, is described. The compensation consists of adding one auxiliary PWM stage to the existing Marx stages, without changing the modularity and topology of the circuit, which controls the output voltage and a LC filter that smoothes the voltage droop in both the positive and negative output pulses. Simulation results are presented for 5 stages Marx circuit using 1 kV per stage, with 1 kHz repetition rate and 10% duty cycle.
Resumo:
This paper presents a variable speed autonomous squirrel cage generator excited by a current-controlled voltage source inverter to be used in stand-alone micro-hydro power plants. The paper proposes a system control strategy aiming to properly excite the machine as well as to achieve the load voltage control. A feed-forward control sets the appropriate generator flux by taking into account the actual speed and the desired load voltage. A load voltage control loop is used to adjust the generated active power in order to sustain the load voltage at a reference value. The control system is based on a rotor flux oriented vector control technique which takes into account the machine saturation effect. The proposed control strategy and the adopted system models were validated both by numerical simulation and by experimental results obtained from a laboratory prototype. Results covering the prototype start-up, as well as its steady-state and dynamical behavior are presented. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
We consider the global scheduling problem of multimode real-time systems upon identical multiprocessor platforms. During the execution of a multimode system, the system can change from one mode to another such that the current task set is replaced with a new task set. Thereby, ensuring that deadlines are met requires not only that a schedulability test is performed on tasks in each mode but also that (i) a protocol for transitioning from one mode to another is specified and (ii) a schedulability test for each transition is performed. In this paper, we extend the synchronous transition protocol SM-MSO in order to take into account mode-independent tasks [1], i.e., tasks of which the execution pattern must not be jeopardized by the mode changes.
Resumo:
OBJETIVO: Estimar a confiabilidade teste-reteste dos itens do Resource Generator scale para avaliação de capital social no Estudo Longitudinal de Saúde do Adulto (ELSA-Brasil).MÉTODOS: A escala de capital social foi aplicada em subamostra de 281 participantes dos seis Centros de Investigação do ELSA, em duas oportunidades, com intervalo de sete a 14 dias. O instrumento é constituído por 31 itens que representam situações concretas para avaliar o acesso a diferentes tipos de recursos, além de avaliar a fonte dos recursos disponíveis (familiares, amigos ou conhecidos). A análise estatística foi realizada por meio de estatísticas kappa (k) e kappa ajustado pela prevalência (ka).RESULTADOS: Os recursos sociais investigados foram encontrados com grande frequência (acima de 50%). Em relação à presença ou ausência dos recursos, as estimativas de confiabilidade ajustadas pela prevalência (ka) variaram de 0,54 a 0,97. No que se refere à fonte de recurso, essas estimativas variaram de ka = 0,45 (alguém que tenha bons contatos com a mídia) a ka = 0,86 (alguém que se formou no Ensino Médio).CONCLUSÕES: A escala apresentou níveis adequados de confiabilidade, que variaram de acordo com o tipo de recurso.
Resumo:
A 10 kJ electromagnetic forming (EMF) modulator with energy recovery based on two resonant power modules, each containing a 4.5 kV/30-kA silicon controlled rectifier, a 1.11-mF capacitor bank and an energy recovery circuit, working in parallel to allow a maximum actuator discharge current amplitude and rate of 50 kA and 2 kA/mu s was successfully developed and tested. It can be plugged in standard single phase 230 V/16 A mains socket and the circuit is able to recover up to 32% of its initial energy, reducing the charging time of conventional EMF systems by up to 68%.
Resumo:
European Transactions on Telecommunications, vol. 18