922 resultados para SINGLE-PHASE FLOW


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pressure drop data are reported for two phase air-water flow through a vertical to horizontal 90° elbow bend set in 0.026 m i.d. pipe. The pressure drop in the vertical inlet tangent showed some significant differences to that found for straight vertical pipe. This was caused by the elbow bend partially choking the inflow resulting in a build-up of pressure and liquid in the vertical inlet riser and differences in the structure of the flow regimes when compared to the straight vertical pipe. The horizontal outlet tangent by contrast gave data in general agreement with literature even to exhibiting a drag reduction region at low liquid rates and gas velocities between 1 and 2 m s -1. The elbow bend pressure drop was best correlated in terms of le/d determined using the actual pressure loss in the inlet vertical riser. The data showed a general increase with fluid rates that tapered off at high fluid rates and exhibited a negative pressure region at low rates. The latter was attributed to the flow being smoothly accommodated by the bend when it passed from slug flow in the riser to smooth stratified flow in the outlet tangent. A general correlation was presented for the elbow bend pressure drop in terms of total Reynolds numbers. A modified Lockhart-Martinelli model gave prediction of the data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new universal flow map has been developed for two-phase co-current flow. The map has been successfully tested against wide variety of data. Flow regime transition predictors suggested by other authors have been shown to be useful. New transitional models are proposed for the stratified to annular regimes, blow through slug and intermittent regimes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Capillary hydrodynamics has three considerable distinctions from macrosystems: first, there is an increase in the ratio of the surface area of the phases to the volume that they occupy; second, a flow is characterized by small Reynolds numbers at which viscous forces predominate over inertial forces; and third, the microroughness and wettability of the wall of the channel exert a considerable influence on the flow pattern. In view of these differences, the correlations used for tubes with a larger diameter cannot be used to calculate the boundaries of the transitions between different flow regimes in microchannels. In the present review, an analysis of published data on a gas-liquid two-phase flow in capillaries of various shapes is given, which makes it possible to systematize the collected body of information. The specific features of the geometry of a mixer and an inlet section, the hydraulic diameter of a capillary, and the surface tension of a liquid exert the strongest influence on the position of the boundaries of two-phase flow regimes. Under conditions of the constant geometry of the mixer, the best agreement in the position of the boundaries of the transitions between different hydrodynamic regimes in capillaries is observed during the construction of maps of the regimes with the use of the Weber numbers for a gas and a liquid as coordinate axes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe extensive studies on a family of perovskite oxides that are ferroelectric and ferromagnetic at ambient temperatures. The data include x-ray diffraction, Raman spectroscopy, measurements of ferroelectric and magnetic hysteresis, dielectric constants, Curie temperatures, electron microscopy
(both scanning electron microscope and transmission electron microscopy (TEM)) studies, and both longitudinal and transverse magnetoelectric constants a33 and a31. The study extends earlier work to lower Fe, Ta, and Nb concentrations at the B-site (from 15%–20% down to 5%). The magnetoelectric
constants increase supralinearly with Fe concentrations, supporting the earlier conclusions of a key role for Fe spin clustering. The room-temperature orthorhombic C2v point group symmetry inferred from earlier x-ray diffraction studies is confirmed via TEM, and the primitive unit cell size is found to be the basic perovskite Z¼1 structure of BaTiO3, also the sequence of phase transitions with increasing temperature from rhombohedral to orthorhombic to tetragonal to cubic mimics barium titanate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We design consistent discontinuous Galerkin finite element schemes for the approximation of a quasi-incompressible two phase flow model of Allen–Cahn/Cahn–Hilliard/Navier–Stokes–Korteweg type which allows for phase transitions. We show that the scheme is mass conservative and monotonically energy dissipative. In this case the dissipation is isolated to discrete equivalents of those effects already causing dissipation on the continuous level, that is, there is no artificial numerical dissipation added into the scheme. In this sense the methods are consistent with the energy dissipation of the continuous PDE system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, an agent-based distributed control scheme is presented to control single-phase parallel inverters in solar photovoltaic (PV) systems connected to microgrids. A communication assisted multi-agent framework is developed within microgrids where agents perform their tasks in a distributed manner with an aim of stabilizing load voltage and current under normal and faulted conditions through the asymptotic tracking of the reference current signal. The distributed agent-based control scheme requires information from the neighboring agents through communication network to decide control actions. The proposed control scheme utilizes Ziegler-Nichols (Z-N) tuning approach to design proportional integral (PI) controllers for controlling inverters within the multi-agent system (MAS). A microgrid with parallel inverter-connected solar PV systems is considered for simulations under normal and faulted conditions where results show the excellency of the proposed agent-based scheme in comparison to the conventional scheme without MAS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a linear quadratic regulator with integral action, ensuring fast dynamic response and resisting capability of voltage deviation from instantaneous reference grid voltage, to control the inverter voltage that can also be used in a microgrid. The proposed control strategy is based on a linear quadratic regulator, minimizing the cost function of the system, with integral action used to impede voltage degradation from a reference voltage for outside disturbances of the system, such as abrupt load change. The combined integral term assists to recover the voltage difference between grid and reference grid voltage. The validity of the proposed controller has been tested with linear and non-linear loads under various conditions. In both cases, the effectiveness of the controller has been proved. The result of the proposed controller is good to track the instantaneous reference grid voltage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper an alternative method based on artificial neural networks is presented to determine harmonic components in the load current of a single-phase electric power system with nonlinear loads, whose parameters can vary so much in reason of the loads characteristic behaviors as because of the human intervention. The first six components in the load current are determined using the information contained in the time-varying waveforms. The effectiveness of this method is verified by using it in a single-phase active power filter with selective compensation of the current drained by an AC controller. The proposed method is compared with the fast Fourier transform.