992 resultados para Rotational Panoramic Radiography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review aims to identify strategies to optimise radiography practice using digital technologies, for full spine studies on paediatrics focusing particularly on methods used to diagnose and measure severity of spinal curvatures. The literature search was performed on different databases (PubMed, Google Scholar and ScienceDirect) and relevant websites (e.g., American College of Radiology and International Commission on Radiological Protection) to identify guidelines and recent studies focused on dose optimisation in paediatrics using digital technologies. Plain radiography was identified as the most accurate method. The American College of Radiology (ACR) and European Commission (EC) provided two guidelines that were identified as the most relevant to the subject. The ACR guidelines were updated in 2014; however these guidelines do not provide detailed guidance on technical exposure parameters. The EC guidelines are more complete but are dedicated to screen film systems. Other studies provided reviews on the several exposure parameters that should be included for optimisation, such as tube current, tube voltage and source-to-image distance; however, only explored few of these parameters and not all of them together. One publication explored all parameters together but this was for adults only. Due to lack of literature on exposure parameters for paediatrics, more research is required to guide and harmonise practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: Optimise a set of exposure factors, with the lowest effective dose, to delineate spinal curvature with the modified Cobb method in a full spine using computed radiography (CR) for a 5-year-old paediatric anthropomorphic phantom. Methods: Images were acquired by varying a set of parameters: positions (antero-posterior (AP), posteroanterior (PA) and lateral), kilo-voltage peak (kVp) (66-90), source-to-image distance (SID) (150 to 200cm), broad focus and the use of a grid (grid in/out) to analyse the impact on E and image quality (IQ). IQ was analysed applying two approaches: objective [contrast-to-noise-ratio/(CNR] and perceptual, using 5 observers. Monte-Carlo modelling was used for dose estimation. Cohen’s Kappa coefficient was used to calculate inter-observer-variability. The angle was measured using Cobb’s method on lateral projections under different imaging conditions. Results: PA promoted the lowest effective dose (0.013 mSv) compared to AP (0.048 mSv) and lateral (0.025 mSv). The exposure parameters that allowed lower dose were 200cm SID, 90 kVp, broad focus and grid out for paediatrics using an Agfa CR system. Thirty-seven images were assessed for IQ and thirty-two were classified adequate. Cobb angle measurements varied between 16°±2.9 and 19.9°±0.9. Conclusion: Cobb angle measurements can be performed using the lowest dose with a low contrast-tonoise ratio. The variation on measurements for this was ±2.9° and this is within the range of acceptable clinical error without impact on clinical diagnosis. Further work is recommended on improvement to the sample size and a more robust perceptual IQ assessment protocol for observers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As it is widely known, in structural dynamic applications, ranging from structural coupling to model updating, the incompatibility between measured and simulated data is inevitable, due to the problem of coordinate incompleteness. Usually, the experimental data from conventional vibration testing is collected at a few translational degrees of freedom (DOF) due to applied forces, using hammer or shaker exciters, over a limited frequency range. Hence, one can only measure a portion of the receptance matrix, few columns, related to the forced DOFs, and rows, related to the measured DOFs. In contrast, by finite element modeling, one can obtain a full data set, both in terms of DOFs and identified modes. Over the years, several model reduction techniques have been proposed, as well as data expansion ones. However, the latter are significantly fewer and the demand for efficient techniques is still an issue. In this work, one proposes a technique for expanding measured frequency response functions (FRF) over the entire set of DOFs. This technique is based upon a modified Kidder's method and the principle of reciprocity, and it avoids the need for modal identification, as it uses the measured FRFs directly. In order to illustrate the performance of the proposed technique, a set of simulated experimental translational FRFs is taken as reference to estimate rotational FRFs, including those that are due to applied moments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This present study aimed to investigate the fatigue life of unused (new) endodontic instruments made of NiTi with control memory by Coltene™ and subjected to the multi curvature of a mandibular first molar root canal. Additionally, the instrument‟s structural behaviour was analysed through non-linear finite element analysis (FEA). The fatigue life of twelve Hyflex™ CM files was assessed while were forced to adopt a stance with multiple radius of curvature, similar to the ones usually found in a mandibular first molar root canal; nine of them were subjected to Pecking motion, a relative movement of axial type. To achieve this, it was designed an experimental setup with the aim of timing the instruments until fracture while worked inside a stainless steel mandibular first molar model with relative axial motion to simulate the pecking motion. Additionally, the model‟s root canal multi-curvature was confirmed by radiography. The non-linear finite element analysis was conducted using the computer aided design software package SolidWorks™ Simulation, in order to define the imposed displacement required by the FEA, it was necessary to model an endodontic instrument with simplified geometry using SolidWorks™ and subsequently analyse the geometry of the root canal CAD model. The experimental results shown that the instruments subjected to pecking motion displayed higher fatigue life values and higher lengths of fractured tips than those with only rotational relative movement. The finite element non-linear analyses shown, for identical conditions, maximum values for the first principal stress lower than the yield strength of the material and those were located in similar positions to the instrument‟s fracture location determined by the experimental testing results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Biomédica (área de especialização em Informática Médica)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All patients having undergone a coronarography during 1984 have been surveyed in Switzerland. This retrospective study has used existing data in the 13 centers practicing this diagnostic procedure. 4921 coronarographies were carried out in 1984, amongst 4359 patients. In terms of population-based rates, the national figures are 77 procedures/100,000 residents, and 68 patients/100,000 residents. Female rates are one fourth of the male rates (27/100,000 versus 112/100,000). For both sexes, the highest utilization rates are for the age groups 60-64. Swiss figures are relatively low when compared with other developed countries. However, patterns of utilization are very different within the country: according to the Canton of residence of the patient, the utilization rates (standardized for age and sex) vary from 8/100,000 to 160/100,000. There is a distinct gradient from south-west to north-east, which closely corresponds to the distribution of centers practicing the procedure. More intriguing is the fact that cardiovascular mortality shows an inverse geographical gradient, with the highest mortality in Cantons having the lowest rate of coronarography. Various reasons for the observed variations are discussed, in relation with differences in supply of diagnostic and therapeutic equipments, but also in relation with various patterns of demand related to differential morbidity rates and/or differential patterns of clinical decision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Depuis plus de 10 ans les modèles numériques d'altitude (MNA) produits par technologie de « light detection and ranging » (« LIDAR ») ont fourni de nouveaux outils très utiles pour des études géomorphologiques, particulièrement dans le cas des glissements de terrain. Le balayage laser terrestre (« TLS ») permet une utilisation très souple. Le TLS peut être employé pour la surveillance ou dans des situations d'urgence qui nécessitent une acquisition rapide d'un MNA afin d'évaluer l'aléa. Au travers de trois exemples, nous démontrons l'utilité du TLS pour la quantification de volumes de glissements de terrain, la création de profils et l'analyse de séries temporelles. Ces études de cas sont des glissements de terrain situés dans les argiles sensibles de l'est du Canada (Québec, Canada) ou de petits glissements rotationnels dans les berges d'une rivière (Suisse).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Cinque Torri group (Cortina d'Ampezzo, Italy) is an articulated system of unstable carbonatic rock monoliths located in a very important tourism area and therefore characterized by a significant risk. The instability phenomena involved represent an example of lateral spreading developed over a larger deep seated gravitational slope deformation (DSGSD) area. After the recent fall of a monolith of more than 10 000 m3, a scientific study was initiated to monitor the more unstable sectors and to characterize the past movements as a fundamental tool for predicting future movements and hazard assessment. To achieve greater insight on the ongoing lateral spreading process, a method for a quantitative analysis of rotational movements associated with the lateral spreading has been developed, applied and validated. The method is based on: i) detailed geometrical characterization of the area by means of laser scanner techniques; ii) recognition of the discontinuity sets and definition of a reference frame for each set, iii) correlation between the obtained reference frames related to a specific sector and a stable external reference frame, and iv) determination of the 3D rotations in terms of Euler angles to describe the present settlement of the Cinque Torri system with respect to the surrounding stable areas. In this way, significant information on the processes involved in the fragmentation and spreading of a former dolomitic plateau into different rock cliffs has been gained. The method is suitable to be applied to similar case studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Workforce Planning Review 2

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Workforce Planning Review

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report of the Project Group

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Expert Group on Radiography Grades was established in accordance with proposals from the Labour Relations Commission. Its aim was to examine and make recommendations for the future development of the profession and the diagnostic imaging and therapy services which ensure the highest level of patient care is delivered in a modern health environment Download the Report here

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stress radiographs have been recommended in order to obtain a better objective quantification of abnormal compartment knee motion. This tool has showed to be superior in quantifying a posterior cruciate ligament (PCL) lesion compared to clinical or arthrometer evaluation. Different radiographic techniques have been described in literature to quantify posterior pathological laxity. In this study we evaluated the total amount of posterior displacement (PTD) and side to side difference (SSD), before and after surgical reconstruction of PCL or PCL and posterolateral complex (PLC), using two different stress radiography techniques (Telos stress and kneeling view). Twenty patients were included in this study. We found a statistical significant difference about both total PTD and SSD among the two techniques preoperatively and at follow-up, with greatest values occurring using the kneeling view. Although stress radiographies has been introduced to allow an objective quantification of laxity in ligamentous injured knee, we believe that further studies on a large numbers of subjects are required to define the relationship between PTD values, measured with stress knee radiography, particularly using kneeling view, and ligamentous knee injury, in order to obtain a real useful tool in the decision making process, as well as to evaluate the outcome after ligamentous surgery.