999 resultados para Rhythmic part


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research is part of a project whose scope was to investigate the engineering properties of new non-commercial alloy formulations based on the Cu rich corner of the Cu-Fe-Cr ternary system with the primary aim of exploring the development of a new cost-effective high-strength, high-conductivity copper alloy. Promising properties have been measured for the following alloys: Cu-0.7wt%Cr-0.3wt%Fe and Cu-0.7wt%Cr-2.0wt%Fe. This paper reports on the microstructural characterisation of these alloys and discusses the mechanical and electrical properties of these alloys in terms of their microstructure, particularly the formation of precipitates. These alloys have evinced properties that warrant further investigation. Cost modelling has shown that Cu-0.7wt%Cr-0.3wt%Fe is approximately 25% cheaper to produce than commercial Cu-1%Cr. It has also been shown to be more cost efficient on a yield stress and % IACS per dollar basis. The reason for the cost saving is that the Cu-0.7%Cr-0.3%Fe alloy can be made with low carbon ferro-chrome additions as the source of chromium rather than the more expensive Cu-Cr master-alloy. For applications in which cost is one of the primary materials selection criteria, it is envisaged that there would be numerous applications in both cast and wrought form, where the Cu-0.7%Cr-0.3%Fe alloy would be more suitable than Cu-1%Cr. (C) 2001 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To examine the feasibility and safety of a low anterior resection of the rectosigmoid plus adjacent pelvic tumour as part of primary cytoreduction for ovarian cancer. Methods. This study included 65 consecutive patients with primary ovarian cancer who had debulking surgery from 1996 through 2000. All patients underwent an en bloc resection of ovarian cancer and a rectosigmoid resection followed by an end-to-end anastomosis. Parameters for safety and efficacy were considered as primary statistical endpoints for the aim of this analysis. Results. Postoperative residual tumour was nil, 1 cm in 14, 34, and 14 patients, respectively. The median postoperative hospital stay was 11 days (range, 6 to 50 days). Intraoperative complications included an injury to the urinary bladder in one patient. Postoperative complications included wound complications (n=14, 21.5%), septicemia (n=9, 13.8%), cardiac complications (n=7, 10.8%), thromboembolic complications (n=5, 7.7%) ileus (n=2, 3.1%) anastomotic leak (n=2, 3.1%) and fistula (n=1, 1.5%). Reasons for a reoperation during the same admission included repair of an anastomotic leak (n=1), postoperative hemorrhage (n=1), and wound debridement (n=1). Wound complications, septicemia, and anastomotic leak formation were more frequent in patients who had a serum albumin level of less than or equal to 30 g/L preoperatively. There was one surgically related mortality in a patient who died from a cerebral vascular accident 2 days postoperatively. Conclusions. An en bloc resection as part of primary cytoreductive surgery for ovarian cancer is effective and its morbidity is acceptably low. (C) 2001 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To demonstrate that the combination of impression cytology and single cell DNA fingerprinting represents a powerful tool that is suitable for detecting transplanted cells after corneal limbal allografting. Methods, Fifty single cells were obtained by corneal impression cytology from 12 patients undergoing cataract surgery. Individual cells were isolated from samples by micromanipulation. Polymerase chain reaction and short tandem repeat profiling was used to obtain forensic standard DNA fingerprints from single cells. Blood samples taken at the time of impression cytology provided control fingerprints. Results, informative DNA fingerprints were obtained from all corneal samples and 66% (33 of 50 cells) of isolated single cells, Of all fingerprints obtained, most (91%, 30 of 33 fingerprints) corneal fingerprints matched corresponding blond sample fingerprints. At least one corneal fingerprint matched the corresponding blood sample fingerprint in 83% (10 of 12 patients) of the patients in the study, Conclusions. This extremely specific single cell DNA fingerprinting system permits accurate identification of individual corneal epithelial cells, allowing very reliable determination of their origin, which will enable host and donor cells to be distinguished from each other after keratolimbal allografting procedures. even if the host and donor are the same sex or siblings. These DNA fingerprinting methods allow assessment of quality and quantity of donor cell survival, as well as survival time. The extreme sensitivity and accuracy of the technique means that should contamination occur, it would be identified, thus ensuring meaningful results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An archaeological survey on Peel Island in Moreton Bay, southeast Queensland, was conducted to assist the conservation planning for the Peel Island Lazaret (PIL), one of a number of institutions housed on the island during the nineteenth and twentieth centuries. The survey revealed a patteming of artefacts across the island as well as landscape modification related to its Aboriginal and European institutional uses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: First, to assess the clinical effectiveness of hylan G-F 20 in an appropriate care treatment regimen (as defined by the American College of Rheumatology (ACR) 1995 guidelines) as measured by validated disease-specific outcomes and health-related quality of life endpoints for patients with osteoarthritis (OA) of the knee. Second, to utilize the measures of effectiveness and costs in an economic evaluation (see accompanying manuscript). Design: A total of 255 patients with OA of the knee were enrolled by rheumatologists or orthopedic surgeons into a prospective, randomized, open-label, 1-year, multi-centred trial, conducted in Canada. Patients were randomized to 'Appropriate care with hylan G-F 20' (AC+H) or 'Appropriate care without hylan G-F 20' (AC). Data were collected at clinic visits (baseline, 12 months) and by telephone (1, 2, 4, 6, 8, 10, and 12 months). Results: The AC+H group was superior to the AC group for all primary (% reduction in mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain scale: 38% vs 13%, P=0.0001) and secondary effectiveness outcome measures. These differences were all statistically significant and exceeded the 20% difference between groups seta priori by the investigators as the minimum clinically important difference. Health-related quality of life improvements in the AC+H group were statistically superior for the WOMAC pain, stiffness and physical function (all P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To explore circadian variation in pain, stiffness, and manual dexterity inpatients with hand osteoarthritis (OA). Methods: Twenty one patients with hand OA, as defined by ACR criteria (17 women, four men, mean age 62.2 years, range 52-74 years) self rated pain and stiffness on separate 10 cm horizontal visual analogue scales and performed bead intubation coordinometry (BIC) six times each day (on waking up, at bedtime, and every four hours in between) for 10 consecutive days. Each series (using data with the trend removed if there was a significant trend) was analysed for circadian rhythmicity by a cosine. vector technique (single cosinor). With individual data expressed as the percentage of the mean, group rhythm characteristics at period 24 hours were summarised for each variable by population mean cosinor analysis. Results: Individual analyses identified significant circadian rhythms at pless than or equal to0.05 for pain (n=15/21), stiffness (n=16/20), and dexterity (n=18/21), and a significant circadian rhythm on a group basis was identified for pain (p=0.013), stiffness (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has long been supposed that the interference observed in certain patterns of coordination is mediated, at least in part, by peripheral afference from the moving limbs. We manipulated the level of afferent input, arising from movement of the opposite limb, during the acquisition of a complex coordination task. Participants learned to generate flexion and extension movements of the right wrist, of 75degrees amplitude, that were a quarter cycle out of phase with a 1-Hz sinusoidal visual reference signal. On separate trials, the left wrist either was at rest, or was moved passively by a torque motor through 50degrees, 75degrees or 100degrees, in synchrony with the reference signal. Five acquisition sessions were conducted on successive days. A retention session was conducted I week later. Performance was initially superior when the opposite limb was moved passively than when it was static. The amplitude and frequency of active movement were lower in the static condition than in the driven conditions and the variation in the relative phase relation across trials was greater than in the driven conditions. In addition, the variability of amplitude, frequency and the relative phase relation during each trial was greater when the opposite limb was static than when driven. Similar effects were expressed in electromyograms. The most marked and consistent differences in the accuracy and consistency of performance (defined in terms of relative phase) were between the static condition and the condition in which the left wrist was moved through 50degrees. These outcomes were exhibited most prominently during initial exposure to the task. Increases in task performance during the acquisition period, as assessed by a number of kinematic variables, were generally well described by power functions. In addition, the recruitment of extensor carpi radialis (ECR), and the degree of co-contraction of flexor carpi radialis and ECR, decreased during acquisition. Our results indicate that, in an appropriate task context, afferent feedback from the opposite limb, even when out of phase with the focal movement, may have a positive influence upon the stability of coordination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experiment was performed to characterise the movement kinematics and the electromyogram (EMG) during rhythmic voluntary flexion and extension of the wrist against different compliant (elastic-viscous-inertial) loads. Three levels of each type of load, and an unloaded condition, were employed. The movements were paced at a frequency of I Hz by an auditory metronome, and visual feedback of wrist displacement in relation to a target amplitude of 100degrees was provided. Electro-myographic recordings were obtained from flexor carpi radialis (FCR) and extensor carpi radialis brevis (ECR). The movement profiles generated in the ten experimental conditions were indistinguishable, indicating that the CNS was able to compensate completely for the imposed changes in the task dynamics. When the level of viscous load was elevated, this compensation took the form of an increase in the rate of initial rise of the flexor and the extensor EMG burst. In response to increases in inertial load, the flexor and extensor EMG bursts commenced and terminated earlier in the movement cycle, and tended to be of greater duration. When the movements were performed in opposition to an elastic load, both the onset and offset of EMG activity occurred later than in the unloaded condition. There was also a net reduction in extensor burst duration with increases in elastic load, and an increase in the rate of initial rise of the extensor burst. Less pronounced alterations in the rate of initial rise of the flexor EMG burst were also observed. In all instances, increases in the magnitude of the external load led to elevations in the overall level of muscle activation. These data reveal that the elements of the central command that are modified in response to the imposition of a compliant load are contingent, not only upon the magnitude, but also upon the character of the load.