952 resultados para Review Procedures


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In the past 10 years, new anticoagulants (NACs) have been studied for venous thromboembolism (VTE) prophylaxis. Objective: To evaluate the risk/benefit profile of NACs versus enoxaparin for VTE prophylaxis in major orthopedic surgery. Methods: A systematic review of double-blind randomized phase III studies was performed. The search strategy was run from 2000 to 2011 in the main medical electronic databases in any language. Independent extraction of articles was performed by 2 authors using predefined data fields, including study quality indicators. Results: Fifteen published clinical trials evaluating fondaparinux, rivaroxaban, dabigatran, and apixaban were included. Primary efficacy (any deep vein thrombosis [DVT], nonfatal pulmonary embolism, or all-cause mortality) favored fondaparinux (relative risk [RR] 0.50; 95% CI, 0.39, 0.63) and rivaroxaban (RR, 0.50; 95% CI, 0.34, 0.73) over enoxaparin, although significant heterogeneity was observed in both series. The primary efficacy of dabigatran at 220 mg, apixaban, and bemiparin were similar, with RRs of 1.02 (95% CI, 0.86, 1.20), 0.63 (95% CI, 0.39, 1.01), and 0.87 (95% CI, 0.65, 1.17), respectively. The primary efficacy of dabigatran at 150 mg (RR, 1.20; 95% CI, 1.03, 1.41), was inferior to enoxaparin. The incidence of proximal DVT favored apixaban (RR, 0.45; 95% CI, 0.27, 0.75) only. Rivaroxaban (RR, 0.45; 95% CI, 0.27, 0,77) and apixaban (RR, 0.38; 95% CI, 0.16, 0.90) produced significantly lower frequencies of symptomatic DVT. The incidence of major VTE favored rivaroxaban (RR, 0.44; 95% CI, 0.25, 0.81), only. Bleeding risk was similar for all NACs, except fondaparinux (RR, 1.27; 95% CI, 1.04, 1.55), which exhibited a significantly higher any-bleeding risk compared with enoxaparin, and apixaban (RR, 0.88; 95% CI, 0.79, 0.99), which was associated with a reduced risk of any bleeding. Alanine amino transferase was significantly lower with 220 mg of dabigatran, (RR, 0.67; 95% CI, 0.79, 0.99) than with enoxaparin. Conclusions: NACs can be considered alternatives to conventional thromboprophylaxis regimens in patients undergoing elective major orthopedic surgery, depending on clinical characteristics and cost-effectiveness. The knowledge of some differences concerning efficacy or safety profile, pointed out in this systematic review, along with the respective limitations, may be useful in clinical practice. © 2013 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The review purposes are to (1) evaluate the experimental evidence for adverse effects on reproduction and metabolism and (2) identify the current knowledge of analytical procedures, biochemistry and environmental aspects relating to organotins. Organotins are pollutants that are used as biocides in antifouling paints. They produce endocrine-disrupting effects in mollusks, such as imposex. In rodents, organotin exposure induces developmental and reproductive toxicity as well as alteration of metabolic homeostasis through its action as an obesogen. The adverse effects that appear in rodents have raised concerns about organotins' potential health risk to humans in relation to organotin exposure. At present, triorganotin, such as tributyltin, have been demonstrated to produce imposex, and mammalian reproductive and metabolic toxicity. For most mammals, triorganotin exposure predominantly occurs through the ingestion, and this compound can cross the placenta. With these risks in mind, it is important to improve our knowledge of organotins' effects on environmental health. © 2012 Elsevier Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Odontogenic cysts are considered as nonneoplasic benign lesions. Among the cysts, keratocyst odontogenic tumor (KCOT) is an intra‑osseous tumor characterized by parakeratinized stratified squamous epithelium and a potential for aggressive, infiltrative behavior, and for the possibility to develop carcinomas in the lesion wall. Thus, the aim of this study was to describe a clinical case of KCOT in a young patient and discuss the treatment alternatives to solve this case. A 15‑year‑old male was referred for treatment of a giant lesion in his left side of the mandible. After the biopsy, a diagnostic of KCOT was made, and the following procedures were planned for KCOT treatment. Marsupialization was performed for lesion decompression and consequent lesion size reduction. Afterward, enucleation for complete KCOT removal was performed followed by third mandibular molar extraction. After 5 years, no signs of recurrence were observed. The treatment proposed was efficient in removing the KCOT with minimal surgical morbidity and optimal healing process, and the first and second mandibular molars were preserved with pulp vitality. In conclusion, this treatment protocol was an effective and conservative approach for the management of the KCOT, enabling the reduction of the initial lesion, the preservation of anatomical structures and teeth, allowing quicker return to function. No signs of recurrence after 5 years were observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The removal of resin debris and/or resin cement from the enamel surface without causing iatrogenic is the main objective when removing the orthodontic brackets. Some factors such as the time required for removal, damage to the tooth structure, are essential factors for the clinician at the time of removal. Various techniques are used for the removal of orthodontic brackets after the treatment; it is known that the use of clinical procedures such as the use of diamond burs and some pliers removers can damage the structure of the enamel, often depending on the bond strength that should be taken into consideration at the time of removal. This literature review aims to gather the most relevant studies that can clarify the clinical technique, which may be more suitable for removal of the brackets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our goal was to study the use of 2.0-mm miniplates for the fixation of mandibular fractures. Records of 191 patients who experienced a total of 280 mandibular fractures that were treated with 2.0-mm miniplates were reviewed. One hundred twelve of those patients, presenting 160 fractures, who attended a late follow-up were also clinically evaluated. Miniplates were used in the same positions described by AO/ASIF. No intermaxillary fixation was used. All patients included had a minimum follow-up of 6 months. Demographic data, procedures, postoperative results, and complications were analyzed. Mandibular fractures occurred mainly in males (mean age, 30.3 years). Mean follow-up was 21.92 months. The main etiology was motor vehicle accident. The most common fracture was the angle fracture (28.21%). Twenty-two fractures developed infection, for an overall incidence of 7.85%. When only angle fractures are considered, that incidence is increased to 18.98%. Although only 1 patient (0.89%) described inferior alveolar nerve paresthesia, objective testing revealed sensitivity alterations in 31.52% of the patients who had fractures in regions related to the inferior alveolar nerve. Temporary mild deficit of the marginal mandibular branch was observed in 2.56% of the extraoral approaches performed and 2.48% presented with hypertrophic scars. Incidence of occlusal alterations was 4.0%. Facial asymmetry was observed in 2.67% of the patients, whereas malunion incidence was 1.78%. Fibrous union, mostly partial, occurred in 2.38% of the fractures, but only 1 of those presented with mobility (0.59%). Condylar resorption developed in 6.25% of the fixated condylar fractures. Mean mouth opening was 42.08 mm. The overall incidence of complications, including infections, was similar to those described for more rigid methods of fixation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For oral rehabilitation with implant-supported prostheses, there are required procedures to create the bone volume needed for installation of the implants. Thus, bone grafts from intraoral or extraoral donor sites represent a very favorable opportunity. This study aimed to review the literature on the subject, seeking to discuss parameters for the indications, advantages and complications of techniques for autogenous bone grafts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrospinning has become a widely implemented technique for the generation of nonwoven mats that are useful in tissue engineering and filter applications. The overriding factor that has contributed to the popularity of this method is the ease with which fibers with submicron diameters can be produced. Fibers on that size scale are comparable to protein filaments that are observed in the extracellular matrix. The apparatus and procedures for conducting electrospinning experiments are ostensibly simple. While it is rarely reported in the literature on this topic, any experience with this method of fiber spinning reveals substantial ambiguities in how the process can be controlled to generate reproducible results. The simplicity of the procedure belies the complexity of the physical processes that determine the electrospinning process dynamics. In this article, three process domains and the physical domain of charge interaction are identified as important in electrospinning: (a) creation of charge carriers, (b) charge transport, (c) residual charge. The initial event that enables electrospinning is the generation of region of excess charge in the fluid that is to be electrospun. The electrostatic forces that develop on this region of charged fluid in the presence of a high potential result in the ejection of a fluid jet that solidifies into the resulting fiber. The transport of charge from the charge solution to the grounded collection device produces some of the current which is observed. That transport can occur by the fluid jet and through the atmosphere surrounding the electrospinning apparatus. Charges that are created in the fluid that are not dissipated remain in the solidified fiber as residual charges. The physics of each of these domains in the electrospinning process is summarized in terms of the current understanding, and possible sources of ambiguity in the implementation of this technique are indicated. Directions for future research to further articulate the behavior of the electrospinning process are suggested. (C) 2012 American Institute of Physics. [doi: 10.1063/1.3682464]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molecularly imprinted polymers (MIP's) have been applied in several areas of analytical chemistry, including the modification of electrodes. The main purpose of such modification is improving selectivity; however, a gain in sensitivity was also observed in many cases. The most frequent approaches for these modifications are the electrodeposition of polymer films and sol gel deposits, spin and drop coating and self-assembling of films on metal nanoparticles. The preparation of bulk (body) modified composites as carbon pastes and polymer agglutinated graphite have also been investigated. In all cases several analytes including pharmaceuticals, pesticides, and inorganic species, as well as molecules with biological relevance have been successfully used as templates and analyzed with such devices in electroanalytical procedures. Herein, 65 references are presented concerning the general characteristics and some details related to the preparation of MIP's including a description of electrodes modified with MIP's by different approaches. The results using voltammetric and amperometric detection are described.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Recent reviews have indicated that low level level laser therapy (LLLT) is ineffective in lateral elbow tendinopathy (LET) without assessing validity of treatment procedures and doses or the influence of prior steroid injections. Methods Systematic review with meta-analysis, with primary outcome measures of pain relief and/or global improvement and subgroup analyses of methodological quality, wavelengths and treatment procedures. Results 18 randomised placebo-controlled trials (RCTs) were identified with 13 RCTs (730 patients) meeting the criteria for meta-analysis. 12 RCTs satisfied half or more of the methodological criteria. Publication bias was detected by Egger's graphical test, which showed a negative direction of bias. Ten of the trials included patients with poor prognosis caused by failed steroid injections or other treatment failures, or long symptom duration or severe baseline pain. The weighted mean difference (WMD) for pain relief was 10.2 mm [95% CI: 3.0 to 17.5] and the RR for global improvement was 1.36 [1.16 to 1.60]. Trials which targeted acupuncture points reported negative results, as did trials with wavelengths 820, 830 and 1064 nm. In a subgroup of five trials with 904 nm lasers and one trial with 632 nm wavelength where the lateral elbow tendon insertions were directly irradiated, WMD for pain relief was 17.2 mm [95% CI: 8.5 to 25.9] and 14.0 mm [95% CI: 7.4 to 20.6] respectively, while RR for global pain improvement was only reported for 904 nm at 1.53 [95% CI: 1.28 to 1.83]. LLLT doses in this subgroup ranged between 0.5 and 7.2 Joules. Secondary outcome measures of painfree grip strength, pain pressure threshold, sick leave and follow-up data from 3 to 8 weeks after the end of treatment, showed consistently significant results in favour of the same LLLT subgroup (p < 0.02). No serious side-effects were reported. Conclusion LLLT administered with optimal doses of 904 nm and possibly 632 nm wavelengths directly to the lateral elbow tendon insertions, seem to offer short-term pain relief and less disability in LET, both alone and in conjunction with an exercise regimen. This finding contradicts the conclusions of previous reviews which failed to assess treatment procedures, wavelengths and optimal doses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new Brazilian ABNT NBR 15575 Standard (the ―Standard‖) recommends two methods for analyzing housing thermal performance: a simplified and a computational simulation method. The aim of this paper is to evaluate both methods and the coherence between each. For this, the thermal performance of a low-cost single-family house was evaluated through the application of the procedures prescribed by the Standard. To accomplish this study, the EnergyPlus software was selected. Comparative analyses of the house with varying envelope U-values and solar absorptance of external walls were performed in order to evaluate the influence of these parameters on the results. The results have shown limitations in the current Standard computational simulation method, due to different aspects: weather files, lack of consideration of passive strategies, and inconsistency with the simplified method. Therefore, this research indicates that there are some aspects to be improved in this Standard, so it could better represent the real thermal performance of social housing in Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article characterizes hypersensitivity reactions during anesthetic-surgical procedures. This integrative literature review was conducted in the LILACS, CINAHL, COCHRANE and MEDLINE databases including papers published from 1966 to September 2011. A total of 17 case reports, two prevalence studies and one cohort study were identified. Latex reactions were mainly type III and the primary source of intraoperative reaction was latex gloves. The average time for clinical manifestation was 59.8 minutes after anesthetic induction; 44.4% of patients reported a reaction to latex at the pre-anesthetic evaluation. It was determined that the history of allergic reactions to latex obtained in the pre-anesthetic evaluation does not ensure the safety of patients if the staff is inattentive to the severity of the issue. There is also a tendency to initially attribute the anaphylactic event to the anesthetic drugs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In deterministic optimization, the uncertainties of the structural system (i.e. dimension, model, material, loads, etc) are not explicitly taken into account. Hence, resulting optimal solutions may lead to reduced reliability levels. The objective of reliability based design optimization (RBDO) is to optimize structures guaranteeing that a minimum level of reliability, chosen a priori by the designer, is maintained. Since reliability analysis using the First Order Reliability Method (FORM) is an optimization procedure itself, RBDO (in its classical version) is a double-loop strategy: the reliability analysis (inner loop) and the structural optimization (outer loop). The coupling of these two loops leads to very high computational costs. To reduce the computational burden of RBDO based on FORM, several authors propose decoupling the structural optimization and the reliability analysis. These procedures may be divided in two groups: (i) serial single loop methods and (ii) unilevel methods. The basic idea of serial single loop methods is to decouple the two loops and solve them sequentially, until some convergence criterion is achieved. On the other hand, uni-level methods employ different strategies to obtain a single loop of optimization to solve the RBDO problem. This paper presents a review of such RBDO strategies. A comparison of the performance (computational cost) of the main strategies is presented for several variants of two benchmark problems from the literature and for a structure modeled using the finite element method.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today, the bleaching of nonvital, discolored teeth is a low-risk routine treatment for improving esthetics. This review article focuses on the etiology of tooth discolorations, different treatment techniques, and risks of bleaching procedures. Some tooth discolorations in endodontically treated teeth are caused by dental treatments. The three most popular techniques for nonvital tooth bleaching are the walking bleach technique, inside/outside bleaching, and in-office bleaching. The walking bleach technique is a relatively reliable, fairly simple technique for dentists and patients. Inside/outside bleaching can be used additionally when internal and external bleaching must be combined. Inoffice bleaching seems to be a short-term solution, the effects of which can largely be attributed to dehydration of the teeth. There are still some open questions concerning the bleaching agents. Improved safety seems desirable with regard to adding thiourea as a scavenger of radicals or newer materials such as sodium percarbonate. The thermocatalytic technique, insufficient cervical sealing, and high concentrations of bleaching agents should be avoided, as this can increase the risk of cervical root resorptions. Patients should be informed about the low predictability of bleaching success and the risk of recurrent discoloration. The risk of cervical root resorption should be discussed with the patient. There is a strong correlation between root resorption and dental trauma.