122 resultados para Retificação


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

No presente trabalho, investigamos o transporte eletrônico molecular em dois compostos orgânicos, o Ponceau SS (PSS) e o Oligo-(para)fenileno-vinileno (PPV) através de cálculos ab initio e função de Green de não equilíbrio (FGNE). Estes métodos demonstraram equivalência para a descrição destes dispositivos moleculares. Fizemos cálculos quânticos para o Hamiltoniano derivado de Hartree-Fock (HF) e obtivemos as propriedades de corrente-voltagem (I-V) para as duas estruturas moleculares. Com o método FGNE conseguimos modelar o transporte através de um sistema de multiníveis eletrônicos obtendo a corrente descrevendo as regiões de ressonância e a assimetria do sistema. Como resposta o PSS demonstrou assimetria para polarizações direta e reversa e a ressonância é alcançada mostrando que o dispositivo opere como um transistor molecular bi-direcional. Para o PPV investigamos também as propriedades geométricas através da conexão entre transporte eletrônico e o grau de quiralidade molecular que foi calculado usando o índice quiral que depende apenas das posições atômicas. Obtivemos que moléculas quirais e propriedades estruturais podem induzir uma assimetria no transporte eletrônico, resultando num processo de retificação. Também obtivemos que a resposta elétrica (I-V) e momento de dipolo elétrico são proporcionais ao grau de quiralidade molecular. Estes resultados sugerem que o transporte eletrônico neste sistema pode ser explorado na avaliação do seu grau de quiralidade.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study attempted to observe the performance of three types of diamonds, two natural and one synthetic, to determine which features longer life and greater wear than the others. The methodology employed in this study was to dressed an aluminum oxide grinding wheel, and every twenty paces with a advance of depth dressing of 40 µm per passes, take an image of the tip in a horizontal position and the other in the vertical position of this diamond in a stereoscopic. Thereafter, the dresser was replaced in the rectifier to conduct a new dressing. The criteria to completion of the test was the spark generated by the grinding wheel contact with the base of the dresser, which indicates the end of the contact with the diamond wheel. After the tests, was calculated the areas worn of each diamond in accordance with each image obtained through the aid of a graphics software. The data were then arranged in graphs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Individuals with temporomandibular disorders (TMD) often have signs and symptoms such as intra-articular pain, muscle spasm, neck pain radiating from others who interfere with this balance. Over time can lead to postural changes and correction of the cervical spine, anterior head and shoulder asymmetry. The aim was to verify the effects of manual therapy on posture in subjects with TMD. Materials and methods: 30 volunteers (mean: 21.43± SD:1.43) of both sexes who had TMD classified according to axis I of the Research Diagnostic Criteria participated in this study. These were photographed in the anterior frontal and sagittal planes for analysis of the following angles (acromion clavicular joint, sternoclavicular joint, orbicular external, corners of the mouthand and protruding head). After, the volunteers were divided into groups ATM (manual therapy in the treatment of temporomandibular joint), Cervical (manual therapy in the treatment of cervical joint) and Control. The Kolmogokov-Smirnov test, followed by ANOVA, considering a significance level of 5% was used. Results: Groups ATM, Cervical and Control were considered homogeneous with respect to the values of the angles measured. These also showed no significant difference between the 1st, 5th and 10th sessions, so the manual therapy techniques applied to the TMJ and Cervical groups were not sufficient to change postural alignment. Conclusion: The postural alignment, the TMD patients evaluated in this study did not change after attending the sessions proposals with manual therapy techniques in the cervical and TMJ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of the Global Positioning System technology has brought a real revolution in the surveying and georeferencing techniques, which are the basis for many others relevant studies to the many fields of Geography. In this sense, it was seen a massive growth of the use of GNSS receivers in Brazil from the early 2000s, due the duty of Georreferencing Rural Properties to comply with the 10.267/2001 law. For Georreferencing, it is needed high accuracy receivers, and most of time, it is used two receivers: one static base and one rover. To do the adjustment of the base (in order to correct errors), two ways are utilized: post-processing via the brazilian GNSS network - Rede Brasileira de Monitoramento Contínuo dos Sistemas GNSS (RBMC) or via Precise Point Positioning - Posicionamento por Ponto Preciso, both managed by IBGE. Given the wide range of applications as well as discussions on the accuracy of both methods, this monograph aims to conduct a comparative analysis and prove the effectiveness of both methods considering the INCRA’s Standard for Rural Properties Georreferencing. From the processing of GNSS data collected in Piracicaba, Ituverava, Iperó and São Pedro, it could be seen that the research reached the objectives and shows that both methods are accurate and feasible

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper we study the process of manufacture of wire drawn steel bars 9254, from rolled wire rod. These bars are used in the automotive industry for the manufacture of coil springs, which make up the system damping of several vehicles. The wire drawing process consists of the steps of pre-straightening, shot peening, drawing, cutting and polishing. The study aims to search for the configuration of process variables, which present the best result with respect to bending. To this were maintained settings prestraightening and mechanical stripping and varied angles and stringer polish being studied to replace the spinneret with a working angle, for a string with two working angles. To assist in the analysis of the results was the tool used DOE Software Minitab, which assesses the variation in results according to each parameter and the interaction parameters. It was thus possible to determine the best condition for wire drawing

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Shearplate is an optical glass plate having two flat surfaces and a small angle between them. The use of a high quality shear plate is essential to implement shear interferometric technique . The shear interferometry is a technique used to evaluate the light beam collimation. In order to guarantee the shearplate quality , the complete manufacturing process must be thoroughly monitored. In the manufacturing process, the first step consisted of the glass selection. The selected glass has been submitted to the process of cutting, gluing, chamfering, grinding and polishing. Each phase has been strictly monitored. The quality of the final result depends extremely on an appropriate starting condition, which arises from the grinding process, as the polishing process only recovers the brightness of the part, acting on a small scale on the wearing off of the part, as well as not changing the structured obtained in the grinding process. Respecting all stages of the manufacturing process, the quality of the part has evolved to a good result. The best result obtained showed PV distance of 162 nm, slightly less than λ / 4. This result is significant because the dimensions of the piece with respect to the dimensions of the polisher what interferes directly in the results. The closer are the dimensions of piece and the dimensions of the polisher, the greater the difficulty in controlling the propagation of errors

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEB