931 resultados para Reliability assessment


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Because there is discordance between different immunoassay values for serum hGH, and because clinical state may not correlate with immunoreactive hGH, we have developed an assay to accurately measure serum hGH somatogenic bioactivity. The results of this assay were compared with the Elegance two-site ELISA assay across 135 patient samples in a variety of clinical states. DESIGN The somatogenic assay was based on stable expression of hGH receptor in the murine BaF line, allowing these cells to proliferate in response to hGH. To eliminate interference by other growth factors in serum, we created a specific antagonist of the hGH receptor (similar to Trovert or Pegvisomant) which allowed us to obtain a true measure of hGH somatogenic activity by subtraction of the activity in the presence of the antagonist. The assay was carried out in microtiter plates over 24 h, with oxidation of a chromogenic tetrazolium salt (MTT) as the endpoint. PATIENTS These encompassed a number of different clinical conditions related to short stature, including idiopathic short stature, neurosecretory dysfunction and renal failure, as well as obese patients on dietary restriction and normal volunteers. MEASUREMENTS In addition to the colourimetric (MTT) response to hGH, we measured free hGH by stripping out GHBP-bound hGH using beads coupled to a monoclonal antibody to the GHBP (GH binding protein). All samples were measured in both bioassay and ELISA assay. RESULTS This bioassay was sensitive (5 mU/l or 2 mug/l) and precise, and not subject to interference by the GHBP. There was a good correlation (r = 0.95) between bioactivity and immunoactivity across clinical states. There was, however, an increased bioactivity during secretory peaks (over 25 mU/l), which has been reported previously for the Nb2 bioassay. Free hGH did not correlate with clinical state. CONCLUSIONS Because the results of the Elegance ELISA and the bioassay correlate well, even though there is greater bioactivity at higher hormone concentrations, it is evident that an appropriate immunoassay is able to act as a reliable indicator for clinical assessment. In those rare cases where bio-inactive GH exists, our bioassay should provide an appropriate means to demonstrate this.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Test of Mouse Proficiency (TOMP) was developed to assist occupational therapists and education professionals assess computer mouse competency skills in children from preschool to upper primary (elementary) school age. The preliminary reliability and validity of TOMP are reported in this paper. Methods used to examine the internal consistency, test-retest reliability, and criterion- and construct-related validity of the test are elaborated. In the continuing process of test refinement, these preliminary studies support to varying degrees the reliability and validity of TOMP. Recommendations for further validation of the assessment are discussed along with indications for potential clinical application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. Methods: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. Results: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC = 0.75-0.89) to excellent (ICC greater than or equal to 0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC greater than or equal to 0.93). Conclusions: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurement of Health-Related Quality of Life (HRQoL) of the elderly requires instruments with demonstrated sensitivity, reliability, and validity, particularly with the increasing proportion of older people entering the health care system. This article reports the psychometric properties of the 12-item Assessment of Quality of Life (AQoL) instrument in chronically ill community-dwelling elderly people with an 18-month follow-up. Comparator instruments included the SF-36 and the OARS. Construct validity of the AQoL was strong when examined via factor analysis and convergent and divergent validity against other scales. Receiver Operator Characteristic (ROC) curve analyses and relative efficiency estimates indicated the AQoL is sensitive, responsive, and had the strongest predicative validity for nursing home entry. It was also sensitive to economic prediction over the follow-up. Given these robust psychometric properties and the brevity of the scale, AQoL appears to be a suitable instrument for epidemiologic studies where HRQoL and utility data are required from elderly populations. (C) 2003 Elsevier Science Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Wireless medical systems are comprised of four stages, namely the medical device, the data transport, the data collection and the data evaluation stages. Whereas the performance of the first stage is highly regulated, the others are not. This paper concentrates on the data transport stage and argues that it is necessary to establish standardized tests to be used by medical device manufacturers to provide comparable results concerning the communication performance of the wireless networks used to transport medical data. Besides, it suggests test parameters and procedures to be used to produce comparable communication performance results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper assesses the validity and reliability of two instruments measuring quality of service, the SERVPERF and SERVQUAL scales, replicated in a novel cultural settings, a Portuguese energy company. To provide insights and strategies for managerial intervention, a relation between customers’ satisfaction and quality of service is established. The empirical study suggests a superior convergent and predictive validity of SERVPERF scale to measure quality of service in this settings when comparing to SERVQUAL. The main differences of this study with previous ones, are that this one resorts on a confirmatory factor analysis, the validation of the instruments is performed by using the same measures suggested by their creators and extends the line of research to a novel cultural settings, a Portuguese energy company. Concerning the relationship between service quality and customers’ satisfaction, all of the quality of service attributes correlate almost equally to the satisfaction ones, with a lower weight concerning tangibles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper assesses the validity and reliability of two instruments measuring quality of service, the SERVPERF and SERVQUAL scales, replicated in a novel cultural settings, a Portuguese energy company. To provide insights and strategies for managerial intervention, a relation between customers’ satisfaction and quality of service is established. The empirical study suggests a superior convergent and predictive validity of SERVPERF scale to measure quality of service in this settings when comparing to SERVQUAL. The main differences of this study with previous ones, are that this one resorts on a confirmatory factor analysis, the validation of the instruments is performed by using the same measures suggested by their creators and extends the line of research to a novel cultural settings, a Portuguese energy company. Concerning the relationship between service quality and customers’ satisfaction, all of the quality of service attributes correlate almost equally to the satisfaction ones, with a lower weight concerning tangibles.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose – Quantitative instruments to assess patient safety culture have been developed recently and a few review articles have been published. Measuring safety culture enables healthcare managers and staff to improve safety behaviours and outcomes for patients and staff. The study aims to determine the AHRQ Hospital Survey on Patient Safety Culture (HSPSC) Portuguese version's validity and reliability. Design/methodology/approach – A missing-value analysis and item analysis was performed to identify problematic items. Reliability analysis, inter-item correlations and inter-scale correlations were done to check internal consistency, composite scores. Inter-correlations were examined to assess construct validity. A confirmatory factor analysis was performed to investigate the observed data's fit to the dimensional structure proposed in the AHRQ HSPSC Portuguese version. To analyse differences between hospitals concerning composites scores, an ANOVA analysis and multiple comparisons were done. Findings – Eight of 12 dimensions had Cronbach's alphas higher than 0.7. The instrument as a whole achieved a high Cronbach's alpha (0.91). Inter-correlations showed that there is no dimension with redundant items, however dimension 10 increased its internal consistency when one item is removed. Originality/value – This study is the first to evaluate an American patient safety culture survey using Portuguese data. The survey has satisfactory reliability and construct validity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To develop an instrument to assess discrimination effects on health outcomes and behaviors, capable of distinguishing harmful differential treatment effects from their interpretation as discriminatory events. METHODS: Successive versions of an instrument were developed based on a systematic review of instruments assessing racial discrimination, focus groups and review by a panel comprising seven experts. The instrument was refined using cognitive interviews and pilot-testing. The final version of the instrument was administered to 424 undergraduate college students in the city of Rio de Janeiro, Southeastern Brazil, in 2010. Structural dimensionality, two types of reliability and construct validity were analyzed. RESULTS: Exploratory factor analysis corroborated the hypothesis of the instrument's unidimensionality, and seven experts verified its face and content validity. The internal consistency was 0.8, and test-retest reliability was higher than 0.5 for 14 out of 18 items. The overall score was higher among socially disadvantaged individuals and correlated with adverse health behaviors/conditions, particularly when differential treatments were attributed to discrimination. CONCLUSIONS: These findings indicate the validity and reliability of the instrument developed. The proposed instrument enables the investigation of novel aspects of the relationship between discrimination and health.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To develop and validate a short health literacy assessment tool for Portuguese-speaking adults. METHODS: The Short Assessment of Health Literacy for Portuguese-speaking Adults is an assessment tool which consists of 50 items that assess an individual's ability to correctly pronounce and understand common medical terms. We evaluated the instrument's psychometric properties in a convenience sample of 226 Brazilian older adults. Construct validity was assessed by correlating the tool scores with years of schooling, self-reported literacy, and global cognitive functioning. Discrimination validity was assessed by testing the tool's accuracy in detecting inadequate health literacy, defined as failure to fully understand standard medical prescriptions. RESULTS: Moderate to high correlations were found in the assessment of construct validity (Spearman's coefficients ranging from 0.63 to 0.76). The instrument showed adequate internal consistency (Cronbach's alpha=0.93) and adequate test-retest reliability (intraclass correlation coefficient=0.95). The area under the receiver operating characteristic curve for detection of inadequate health literacy was 0.82. A version consisting of 18 items was tested and showed similar psychometric properties. CONCLUSIONS: The instrument developed showed good validity and reliability in a sample of Brazilian older adults. It can be used in research and clinical settings for screening inadequate health literacy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of uncertainty propagation in composite laminate structures is studied. An approach based on the optimal design of composite structures to achieve a target reliability level is proposed. Using the Uniform Design Method (UDM), a set of design points is generated over a design domain centred at mean values of random variables, aimed at studying the space variability. The most critical Tsai number, the structural reliability index and the sensitivities are obtained for each UDM design point, using the maximum load obtained from optimal design search. Using the UDM design points as input/output patterns, an Artificial Neural Network (ANN) is developed based on supervised evolutionary learning. Finally, using the developed ANN a Monte Carlo simulation procedure is implemented and the variability of the structural response based on global sensitivity analysis (GSA) is studied. The GSA is based on the first order Sobol indices and relative sensitivities. An appropriate GSA algorithm aiming to obtain Sobol indices is proposed. The most important sources of uncertainty are identified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the validity and reliability of an instrument that evaluates the structure of primary health care units for the treatment of tuberculosis.METHODS This cross-sectional study used simple random sampling and evaluated 1,037 health care professionals from five Brazilian municipalities (Natal, state of Rio Grande do Norte; Cabedelo, state of Paraíba; Foz do Iguaçu, state of Parana; Sao José do Rio Preto, state of Sao Paulo, and Uberaba, state of Minas Gerais) in 2011. Structural indicators were identified and validated, considering different methods of organization of the health care system in the municipalities of different population sizes. Each structure represented the organization of health care services and contained the resources available for the execution of health care services: physical resources (equipment, consumables, and facilities); human resources (number and qualification); and resources for maintenance of the existing infrastructure and technology (deemed as the organization of health care services). The statistical analyses used in the validation process included reliability analysis, exploratory factor analysis, and confirmatory factor analysis.RESULTS The validation process indicated the retention of five factors, with 85.9% of the total variance explained, internal consistency between 0.6460 and 0.7802, and quality of fit of the confirmatory factor analysis of 0.995 using the goodness-of-fit index. The retained factors comprised five structural indicators: professionals involved in the care of tuberculosis patients, training, access to recording instruments, availability of supplies, and coordination of health care services with other levels of care. Availability of supplies had the best performance and the lowest coefficient of variation among the services evaluated. The indicators of assessment of human resources and coordination with other levels of care had satisfactory performance, but the latter showed the highest coefficient of variation. The performance of the indicators “training” and “access to recording instruments” was inferior to that of other indicators.CONCLUSIONS The instrument showed feasibility of application and potential to assess the structure of primary health care units for the treatment of tuberculosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Safety is one of the major concerns of process safety engineers in most industrial facilities all over the world. To this scope, some events play an important role once the effect of their consequences can be assumed as totally undesirable. One of these events refers to the occurrence of a fire. Such event can result in catastrophic consequences for life, equipment, and continuity of activities or even leading to environmental damage. A fire protection equipment with low reliability means that this equipment are often unavailable and thus the risk of a fire increases. Maintenance of fire protection equipment is very important because this kind of systems is mostly in a dormant mode, which gives uncertainty about their operability when demanded in a real situation of fire. This article outlines the importance of tests, inspection, and maintenance operations in the context of a fire sprinkler system and proposes a methodology based on international standards and supported by test/inspection reports to correct the frequency of these actions according to the level of degradation of the components and regarding safety purposes. © 2015 American Institute of Chemical Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work is a contribution to the definition and assessment of structural robustness. Special emphasis is given to reliability of reinforced concrete structures under corrosion of longitudinal reinforcement. On this communication several authors’ proposals in order to define and measure structural robustness are analyzed and discussed. The probabilistic based robustness index is defined, considering the reliability index decreasing for all possible damage levels. Damage is considered as the corrosion level of the longitudinal reinforcement in terms of rebar weight loss. Damage produces changes in both cross sectional area of rebar and bond strength. The proposed methodology is illustrated by means of an application example. In order to consider the impact of reinforcement corrosion on failure probability growth, an advanced methodology based on the strong discontinuities approach and an isotropic continuum damage model for concrete is adopted. The methodology consist on a two-step analysis: on the first step an analysis of the cross section is performed in order to capture phenomena such as expansion of the reinforcement due to the corrosion products accumulation and damage and cracking in the reinforcement surrounding concrete; on the second step a 2D deteriorated structural model is built with the results obtained on the first step of the analysis. The referred methodology combined with a Monte Carlo simulation is then used to compute the failure probability and the reliability index of the structure for different corrosion levels. Finally, structural robustness is assessed using the proposed probabilistic index.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, Perfil de Gestão e Sistemas Ambientais