988 resultados para Reconstrução faringoesofágica


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a multi-resolution approach for surface reconstruction from clouds of unorganized points representing an object surface in 3D space. The proposed method uses a set of mesh operators and simple rules for selective mesh refinement, with a strategy based on Kohonen s self-organizing map. Basically, a self-adaptive scheme is used for iteratively moving vertices of an initial simple mesh in the direction of the set of points, ideally the object boundary. Successive refinement and motion of vertices are applied leading to a more detailed surface, in a multi-resolution, iterative scheme. Reconstruction was experimented with several point sets, induding different shapes and sizes. Results show generated meshes very dose to object final shapes. We include measures of performance and discuss robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Several studies emphasize the importance of assessing the knee function after anterior cruciate ligament (ACL) reconstruction. The influence of several variables on the function of these patients has been analyzed, but there is no consensus in the science literature. Purpose: To evaluate the correlation between the torque and balance on the knee function after ACL reconstruction. Methods: 23 males patients with ACL reconstruction were tested. The procedures of the study included analysis of concentric peak torque at 60o/s and 180o/s of quadriceps femoris and hamstring muscle with a isokinetic dynamometer. The balance in single-limb stance was measured with stabilometry. The functional performance were performed by two hop tests. To estimate the subjective function of the patients was applied Lysholm Knee Scoring Scale and a Global Rating scale. Results: The analysis of data showed a moderate positive correlation between knee extensor torque and functional performance tests (r= 0,48; p=0,02). A moderate negative correlation was found between the two variables of the stabilometry center of pressure and average speed of centre of pressure and the Global Rating scale (r = -0.4, p = 0,04 and r = -0,49, p = 0 ,02, respectively). No correlation was found between peak torque and balance in single-limb stance. Conclusion: The results of the present study suggest that knee extensor strength and postural balance have some influence on knee function in patients after ACL reconstruction

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Muscle fatigue is a phenomenon that promotes physiological and biomechanical disorders and their changes in healthy subjects have been widely studied and have significant importance for care in preventing injuries, but we do not have many information about its effects in patients after ACL reconstruction. Thus, this study is to analyze the effects of fatigue on neuromuscular behavior of quadriceps after ACL reconstruction. To reach this objective, participants were forty men, twenty healthy (26,90 ± 6,29 years) and twenty after ACL reconstruction (29,75 ± 7,01 years) with a graft of semitendinosus and gracilis tendons, between four to six months after surgery. At first, there was an assessment of joint position sense (JPS) at the isokinetic dynamometer at a speed of 5°/s and target angle of 45° to analyze the absolute error of JPS. Next, we applied the a muscle fatigue protocol, running 100 repetitions of isokinetic knee flexion-extension at 90°/s. Concurrently with this protocol, there was the assessment of muscle performance, as the peak torque (PT) and fatigue index, and electromyographic activity (RMS and median frequency). Finally, we repeated the assessment of JPS. The statistical analysis showed that patients after ACL reconstruction have, even under normal conditions, the amended JPS compared with healthy subjects and that after fatigue, both have disturbances in the JPS, but this alteration is significantly exacerbated in patients after ACL reconstruction. About muscle performance, we could notice that these patients have a lower PT, although there are no differences between the dynamometric and EMG fatigue index. These findings show the necessity about the cares of pacients with ACL reconstruction in respect of the risks of articulate instability and overload in ligamentar graft

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L´étude du processus de construction / reconstruction des compétences de l´assistant social sous la gestion du SESI (Service Social de l´ Industrie), Natal/RN, dès la moitié des années 90 a réaffirmer la perspective que ce processus est le résultat de déterminations macrosociétaires qui sont présents, particulièrement au Brésil, aussi que, la façon par laquelle l´assistant social, le professionnel inscrit dans la division sociale et technique du travail, fait développer son perfectionement technique et intelectuel dans un milieu de nouvelles structures productives qui éxigent un nouveau profil du professionnel face à la crise du capital et de l´État. Cette recherche, de nature qualitative et quantitative, a eu lieu par de combinaisons de recherche bibliographique et empirique. Les sujets ont été huit assistants sociaux et six travailleurs administratifs du SESI, Natal/RN. Les donnés ont été obtenus par des interviews semi-structrées. On a analisé les changements qui sont arrivés dans les gestions du SESI et les compétences qui sont éxigées de l´assistant social ; l´influence du milieu socio-occupationel sur l´action professionnelle et sur le processus de construction/reconstruction de compétences; l´agrandissement de demandes institutionnelles pour l´assistant social par rapport à la prestation de services ; aussi que la constatation de l´importance de ce professionnel, sa hardiesse, mais aussi quelques limites et défis affrontés face à la qualification stimulé par le SESI, en amenant le professionnel dans un processus contradictoire de qualification et disqualification professionelle

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a ligação entre músculos oculares extrínsecos e esferas de polietileno poroso usando um bioadesivo. MÉTODOS: Estudo experimental envolvendo 8 coelhos albinos submetidos a enucleação do olho direto com colocação de implante esférico de polietileno poroso de 12 mm de diâmetro unido aos músculos oculares extrínsecos por meio do bioadesivo 2-octil-cianoacrilato. Noventa dias após a cirurgia os animais foram sacrificados e o conteúdo orbitário removido. em 4 animais foi realizado estudo biomecânico, avaliando-se a força de ruptura entre a musculatura e a esfera (grupo implante) e entre a musculatura e a esclera nos olhos contralaterais (grupo controle). Nos outros 4 animais foi realizada análise histológica. RESULTADO: A avaliação biomecânica revelou que a força de ruptura entre esfera-músculo e esclera-músculo foram semelhantes quando se usa o adesivo de cianoacrilato. O exame histológico mostrou reação fibrovascular no local da adesão entre a musculatura e a esfera, sem efeitos deletérios aos tecidos. Ao redor dos implantes foi possível observar pseudocápsula e no interior, neovasos e tecido fibrovascular preenchendo os espaços entre os grânulos do polietileno. CONCLUSÃO: O adesivo 2-octil-cianoacrilato mantém boa força de adesão na união entre os músculos e as esferas de polietileno poroso, com redução do tempo cirúrgico e sem efeitos deletérios aos tecidos orbitais. Desta forma, deve-se considerar o uso do bioadesivo na reconstrução da cavidade anoftálmica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo: Apresentar as complicações observadas com esferas de diferentes materiais na reconstrução da cavidade anoftálmica. Métodos: Foram avaliados retrospectivamente 117 portadores de cavidade anoftálmica, com tempo mínimo de seguimento de 6 meses, procurando correlacionar sexo, tipo de esfera utilizada, causa da perda do olho, diâmetro da prótese, tipo de cirurgia e a ocorrência das complicações (deiscências e expulsão da esfera). Resultados: As deiscências ocorreram principalmente com esferas de polímero vegetal. A expulsão da esfera ocorreu mais precocemente nos implantes integráveis e foi mais freqüente com as esferas não-integráveis (PMMA). A esfera de polietileno (Polipore) foi a que apresentou menos probabilidade de complicações. Conclusão: A esfera de polietileno é na atualidade a melhor alternativa para preenchimento da cavidade anoftálmica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avaliou-se o efeito da reconstrução do ligamento cruzado cranial, associado ou não ao sulfato de condroitina, na evolução da osteoartrite induzida experimentalmente em cães. Vinte cães hígidos, sem raça definida, machos e fêmeas, com peso corpóreo entre 19 e 25kg, foram submetidos à desmotomia do ligamento cruzado cranial. Trinta dias após, foram separados em dois grupos de 10 animais. Um grupo foi submetido à reconstrução do ligamento cruzado com uso de aloenxerto de ligamento patelar congelado, o outro não. Trinta e um dias após a desmotomia, cada grupo foi dividido em dois subgrupos de cinco animais. Um recebeu sulfato de condroitina, o outro não. Os cães foram avaliados clínica e radiograficamente antes da desmotomia e aos 30, 60 e 90 dias após a desmotomia. No último momento foram realizados exames macro e microscópico. Nos cães submetidos somente à desmotomia e tratados com sulfato de condroitina houve redução na progressão das alterações ósseas, ao exame radiográfico. A reconstrução do ligamento cruzado cranial melhorou a função do membro e, quando associada ao sulfato de condroitina, houve melhor resposta. Não houve diferença entre os subgrupos quanto aos exames macro e microscópico.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Relacionar a área de secção inicial do enxerto com o resultado da cirurgia de reconstrução do LCA. Foram operados oito cães, divididos em dois grupos, de acordo com o tamanho do enxerto: grupo A - 25% e grupo B - 40% da largura do ligamento patelar (LP). MÉTODOS: Após oito meses, os cães foram sacrificados para análise macroscópica e histológica dos ligamentos reconstruídos, utilizando-se o joelho contralateral do cão como controle. RESULTADOS: em ambos os grupos, todos os ligamentos reconstruídos apresentaram-se viáveis e hipertrofiados; o enxerto de LP teve sua morfologia alterada, verificada através da medida do crimp e da celularidade, assemelhando-se com a do LCA. CONCLUSÃO: A área de secção do enxerto não influenciou o resultado histológico da cirurgia de reconstrução do LCA em cães.