943 resultados para Rapid HIV Testing
Resumo:
A new generation of water soluble tetrazolium salts have recently become available and in this study we compared a colorimetric assay developed using one of these salts, 2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2, 4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8), with a previously developed 2,3-bis [2-methyloxy-4-nitro-5-sulfophenyl]-2H-tetrazolium-5-carboxanilide (XTT) colorimetric assay to determine which agent is most suitable for use as a colorimetric indicator in susceptibility testing. The MICs of 6 antibiotics were determined for 33 staphylococci using both colorimetric assays and compared with those obtained using the British Society for Antimicrobial Chemotherapy reference broth microdilution method. Absolute categorical agreement between the reference and test methods ranged from 79% (cefuroxime) to 100% (vancomycin) for both assays. No minor or major errors occurred using either assay with very major errors ranging from zero (vancomycin) to seven (cefuroxime). Analysis of the distribution of differences in the log2 dilution MIC results revealed overall agreement, within the accuracy limits of the standard test (± 1 log2 dilution), using the XTT and WST-8 assays of 98% and 88%, respectively. Further studies on 31 ESBL-producing isolates were performed using the XTT method with absolute categorical agreement ranging from 87% (nitrofurantoin) to 100% (ofloxacin and meropenem). No errors were noted for either ofloxacin or meropenem with overall agreement of 91%. The data suggests that XTT is more reliable and accurate than WST-8 for use in a rapid antimicrobial susceptibility test.
Resumo:
The use of perceptual inputs is an emerging area within HCI that suggests a developing Perceptual User Interface (PUI) that may prove advantageous for those involved in mobile serious games and immersive social network environments. Since there are a large variety of input devices, software platforms, possible interactions, and myriad ways to combine all of the above elements in pursuit of a PUI, we propose in this paper a basic experimental framework that will be able to standardize study of the wide range of interactive applications for testing efficacy in learning or information retrieval and also suggest improvements to emerging PUIs by enabling quick iteration. This rapid iteration will start to define a targeted range of interactions that will be intuitive and comfortable as perceptual inputs, and enhance learning and information retention in comparison to traditional GUI systems. The work focuses on the planning of the technical development of two scenarios, and the first steps in developing a framework to evaluate these and other PUIs for efficacy and pedagogy.
Resumo:
Human fungal infections have increased at an alarming rate in recent years, particularly in immunocompromised individuals. Cryptococcosis is the second most prevalent systemic fungal infection worldwide, and the most prevalent systemic infection in immunocompromised individuals, representing more than 70% of cases. The incidence of cryptococcosis is high in people with HIV/acquired immunodeficiency syndrome (AIDS), with recent estimates indicating that there are one million cases of cryptococcal meningitis globally per year in AIDS patients. The aim of this research was to develop a rapid flow cytometric antifungal susceptibility test and to compare the results with the standard methods. A reference strain and clinical isolates of Cryptococcus neoformans and Cryptococcus gattii were tested for susceptibility to amphotericin B by flow cytometry using propidium iodide as indicator of viability. Flow cytometry (FC) results were compared with the minimum inhibitory concentration (MIC) values determined by microdilution. The antifungal activity of amphotericin B ranged from MICs of 0.06 to 2μg/ml for the 11 isolates studied. The same results were found by FC. The FC method allows same-day results, assisting in the selection of appropriate antifungal therapies. These results demonstrate an excellent correlation between FC and the classic methods of testing for susceptibility to antifungal agents. This rapid diagnosis method makes it possible to quickly administer effective therapeutic interventions, often saving lives.
Resumo:
Introduction: Primary HIV infection is usually caused by R5 viruses, and there is an association between the emergence of CCXR4-utilizing strains and faster disease progression. We characterized HIV-1 from a cohort of recently infected individuals in Brazil, predicted the virus's co-receptor use based on the env genotype and attempted to correlate virus profiles with disease progression. Methods: A total of 72 recently infected HIV patients were recruited based on the Serologic Testing Algorithm for Recent HIV Seroconversion and were followed every three to four months for up to 78 weeks. The HIV-1 V3 region was characterized by sequencing nine to twelve weeks after enrollment. Disease progression was characterized by CD4+ T-cell count decline to levels consistently below 350 cells/mu L. Results: Twelve out of 72 individuals (17%) were predicted to harbor CXCR4-utilizing strains; a baseline CD4,350 was more frequent among these individuals (p = 0.03). Fifty-seven individuals that were predicted to have CCR5-utilizing viruses and 10 individuals having CXCR4-utilizing strains presented with baseline CD4.350; after 78 weeks, 33 individuals with CCR5 strains and one individual with CXCR4 strains had CD4.350 (p = 0.001). There was no association between CD4 decline and demographic characteristics or HIV-1 subtype. Conclusions: Our findings confirm the presence of strains with higher in vitro pathogenicity during early HIV infection, suggesting that even among recently infected individuals, rapid progression may be a consequence of the early emergence of CXCR4-utilizing strains. Characterizing the HIV-1 V3 region by sequencing may be useful in predicting disease progression and guiding treatment initiation decisions.
Evaluation of rapid tests for human immunodeficiency virus as a tool to detect recent seroconversion
Resumo:
The identification of recent HIV infection is important for epidemiological studies and to monitor the epidemic. The objective of this study was to evaluate two rapid tests that are easily available to the Brazilian scientific community for using as markers of recent HIV infection. The Rapid Test - HIV-1/2 Bio-Manguinhos (Bio-Manguinhos/Fiocruz, Brazil) and the Rapid Check HIV 1&2 (NDI-UFES, Center for Infectious Diseases, Universidade Federal do Espirito Santo) were tested, using 489 samples with HIV positive serology, from blood donors, previously classified as recent or long-term infection by serological testing algorithm for recent HIV seroconversion (STARHS) or LS-HIV Vitros assay methods. The samples were diluted prior to testing (1:50 and 1:100 for the Rapid Test - HIV-1/2 Bio-Manguinhos, and 1:500 and 1:600 for the Rapid Check HIV 1&2). Negative samples were considered recent infection, whereas those showing any color intensity were associated with long-term infection. The best dilutions were 1:100 for HIV-1/2 Bio-Manguinhos test (Kappa = 0.840; overall agreement = 0.93), and 1:500 for the Rapid Check HIV 1&2 (Kappa = 0.867; overall agreement = 0.94). The results suggest that both rapid tests can be used to detect recent seroconversion. (C) 2012 Elsevier Editora Ltda. All rights reserved.
Resumo:
To evaluate the impact of a national HIV voluntary counselling and testing (VCT) campaign on presentation to HIV care in a rural population in Tanzania.
Resumo:
Background Replicative phenotypic HIV resistance testing (rPRT) uses recombinant infectious virus to measure viral replication in the presence of antiretroviral drugs. Due to its high sensitivity of detection of viral minorities and its dissecting power for complex viral resistance patterns and mixed virus populations rPRT might help to improve HIV resistance diagnostics, particularly for patients with multiple drug failures. The aim was to investigate whether the addition of rPRT to genotypic resistance testing (GRT) compared to GRT alone is beneficial for obtaining a virological response in heavily pre-treated HIV-infected patients. Methods Patients with resistance tests between 2002 and 2006 were followed within the Swiss HIV Cohort Study (SHCS). We assessed patients' virological success after their antiretroviral therapy was switched following resistance testing. Multilevel logistic regression models with SHCS centre as a random effect were used to investigate the association between the type of resistance test and virological response (HIV-1 RNA <50 copies/mL or ≥1.5log reduction). Results Of 1158 individuals with resistance tests 221 with GRT+rPRT and 937 with GRT were eligible for analysis. Overall virological response rates were 85.1% for GRT+rPRT and 81.4% for GRT. In the subgroup of patients with >2 previous failures, the odds ratio (OR) for virological response of GRT+rPRT compared to GRT was 1.45 (95% CI 1.00-2.09). Multivariate analyses indicate a significant improvement with GRT+rPRT compared to GRT alone (OR 1.68, 95% CI 1.31-2.15). Conclusions In heavily pre-treated patients rPRT-based resistance information adds benefit, contributing to a higher rate of treatment success.
Nanoduct(R) sweat testing for rapid diagnosis in newborns, infants and children with cystic fibrosis
Resumo:
Determination of chloride concentration in sweat is the current diagnostic gold standard for Cystic Fibrosis (CF). Nanoduct(R) is a new analyzing system measuring conductivity which requires only 3 microliters of sweat and gives results within 30 minutes. The aim of the study was to evaluate the applicability of this system in a clinical setting of three children's hospitals and borderline results were compared with sweat chloride concentration. Over 3 years, 1,041 subjects were tested and in 946 diagnostic results were obtained. In 95 children, Nanoduct(R) failed (9.1% failure rate), mainly due to failures in preterm babies and newborns. Assuming 59 mmol/L as an upper limit of normal conductivity, all our 46 CF patients were correctly diagnosed (sensitivity 100%, 95% CI: 93.1-100; negative predicted value 100% (95% CI: 99.6-100) and only 39 non CF's were false positive (39/900, 4.3%; specificity 95.7%, 95%CI: 94.2-96.9, positive predicted value 54.1% with a 95%CI: 43.4-65.0). Increasing the diagnostic limit to 80 mmol/L, the rate fell to 0.3% (3/900). CF patients had a median conductivity of 115 mmol/L; the non-CF a median of 37 mmol/L. In conclusion, the Nanoduct(R) test is a reliable diagnostic tool for CF diagnosis: It has a failure rate comparable to other sweat tests and can be used as a simple bedside test for fast and reliable exclusion, diagnosis or suspicion of CF. In cases with borderline conductivity (60-80 mmol/L) other additional methods (determination of chloride and genotyping) are indicated.
Resumo:
BACKGROUND: We aimed to assess the value of a structured clinical assessment and genetic testing for refining the diagnosis of abacavir hypersensitivity reactions (ABC-HSRs) in a routine clinical setting. METHODS: We performed a diagnostic reassessment using a structured patient chart review in individuals who had stopped ABC because of suspected HSR. Two HIV physicians blinded to the human leukocyte antigen (HLA) typing results independently classified these individuals on a scale between 3 (ABC-HSR highly likely) and -3 (ABC-HSR highly unlikely). Scoring was based on symptoms, onset of symptoms and comedication use. Patients were classified as clinically likely (mean score > or =2), uncertain (mean score > or = -1 and < or = 1) and unlikely (mean score < or = -2). HLA typing was performed using sequence-based methods. RESULTS: From 131 reassessed individuals, 27 (21%) were classified as likely, 43 (33%) as unlikely and 61 (47%) as uncertain ABC-HSR. Of the 131 individuals with suspected ABC-HSR, 31% were HLA-B*5701-positive compared with 1% of 140 ABC-tolerant controls (P < 0.001). HLA-B*5701 carriage rate was higher in individuals with likely ABC-HSR compared with those with uncertain or unlikely ABC-HSR (78%, 30% and 5%, respectively, P < 0.001). Only six (7%) HLA-B*5701-negative individuals were classified as likely HSR after reassessment. CONCLUSIONS: HLA-B*5701 carriage is highly predictive of clinically diagnosed ABC-HSR. The high proportion of HLA-B*5701-negative individuals with minor symptoms among individuals with suspected HSR indicates overdiagnosis of ABC-HSR in the era preceding genetic screening. A structured clinical assessment and genetic testing could reduce the rate of inappropriate ABC discontinuation and identify individuals at high risk for ABC-HSR.
Resumo:
QUESTIONS UNDER STUDY: To assess whether the prevalence of HIV positive tests in clients at five anonymous testing sites in Switzerland had increased since the end of the 1990s, and ascertain whether there had been any concurrent change in the proportions of associated risk factors. METHODS: Baseline characteristics were analysed, by groups of years, over the eleven consecutive years of data collected from the testing sites. Numbers of HIV positive tests were presented as prevalence/1000 tests performed within each category. Multivariable analyses, stratified by African nationality and risk group of heterosexuals or men who have sex with men (MSM), were done controlling simultaneously for a series of variables. Odds ratios (ORs) were reported together with their 95% confidence intervals (CI). P values were calculated from likelihood ratio tests. RESULTS: There was an increase in the prevalence of positive tests in African heterosexuals between 1996-1999 and 2004-2006, rising from 54.2 to 86.4/1000 and from 5.6 to 25.2/1000 in females and males respectively. The proportion of MSM who knew that one or more of their sexual partners was infected with HIV increased from 2% to 17% and the proportion who reported having more than five sexual partners in the preceding two years increased from 44% to 51%. CONCLUSIONS: Surveillance data from anonymous testing sites continue to provide useful information on the changing epidemiology of HIV and thus inform public health strategies against HIV.
Variability of anti-PF4/heparin antibody results obtained by the rapid testing system ID-H/PF4-PaGIA
Resumo:
BACKGROUND: Recent studies have shown that a low clinical pretest probability may be adequate for excluding heparin-induced thrombocytopenia. However, for patients with intermediate or high pretest probability, laboratory testing is essential for confirming or refuting the diagnosis. Rapid assessment of anti-PF4/heparin-antibodies may assist clinical decision-making. OBJECTIVES: To evaluate the performance of rapid ID-H/PF4-PaGIA. In particular, we verified reproducibility of results between plasma and serum specimens, between fresh and frozen samples, and between different ID-H/PF4-polymer lots (polystyrene beads coated with heparin/PF4-complexes). PATIENTS/METHODS: The samples studied were 1376 plasma and 914 corresponding serum samples from patients investigated for suspected heparin-induced thrombocytopenia between January 2000 and October 2008. Anti-PF4/heparin-antibodies were assessed by ID-H/PF4-PaGIA, commercially available ELISAs and heparin-induced platelet aggregation test. RESULTS: Among 914 paired plasma/serum samples we noted discordant results (negative vs. low-titre positive) in nine instances (1%; 95%CI, 0.4-1.6%). Overall, agreement between titres assessed in plasma vs. serum was highly significant (Spearman correlation coefficient, 0.975; P < 0.0001). Forty-seven samples tested both fresh and after freezing/thawing showed a good agreement, with one discordant positive/negative result (Spearman correlation coefficient, 0.970; P < 0.0001). Among 1376 plasma samples we noted a strikingly variable incidence of false negative results (none - 82%; 95%CI, 66-98%), depending on the employed ID-H/PF4-polymer lot. Faulty lots can be recognized by titrating commercial positive controls and stored samples of HIT-patients. CONCLUSION: Laboratories performing the assay should implement stringent internal quality controls in order to recognize potentially faulty ID-H/PF4-polymer lots, thus avoiding false negative results.