998 resultados para Radiology technicians


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The purpose of this paper is to present the technical specifications of the Forensic Reference Phantom (FRP), to test its behavior relative to organic test materials, and discuss potential applications of the phantom in forensic radiology. Materials and method The FRP prototype is made of synthetic materials designed to simulate the computed tomography (CT) attenuation of water. It has six bore holes that accommodate multiuse containers. These containers were filled with test materials and scanned at 80 kVp, 120 kVp, and 140 kVp. X-ray attenuation was measured by two readers. Intra- and inter-reader reliability was assessed using the intra-class correlation coefficient (ICC). Significance levels between mean CT numbers at 80 kVp, 120 kVp, and 140 kVp were assessed with the Friedman-test. The T-test was used to assess significance levels between the FRP and water. Results Overall mean CT numbers ranged from −3.0–3.7HU for the FRP; −1000.3–−993.5HU for air; −157.7– −108.1HU for oil; 35.5–42.0HU for musle tissue; and 1301.5–2354.8HU for cortical bone. Inter-reader and intra-reader reliability were excellent (ICC>0.994; and ICC=0.999 respectively). CT numbers were significantly different at different energy levels. There was no significant difference between the attenuation of the FRP and water. Conclusions The FRP is a new tool for quality assurance and research in forensic radiology. The mean CT attenuation of the FRP is equivalent to water. The phantom can be scanned during routine post-mortem CT to assess the composition of unidentified objects. In addition, the FRP may be used to investigate new imaging algorithms and scan protocols in forensic radiology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiologists have been confronted with multiple new challenges in recent years. While there has been a steady increase in the number of radiological examinations and imaging material per examination, examination protocols have become more complex and highly time-consuming whereas case-based remuneration is on the decline. The identification of inefficient components in examination processes and reporting is therefore essential. Where and why do time delays occur? How can they be avoided? The following article provides a brief overview and is designed to stimulate discussion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forensic radiology is a new subspecialty that has arisen worldwide in the field of forensic medicine. Postmortem computed tomography (PMCT) and, to a lesser extent, PMCT angiography (PMCTA), are established imaging methods that have replaced dated conventional X-ray images in morgues. However, these methods have not been standardized for postmortem imaging. Therefore, this article outlines the main approach for a recommended standard protocol for postmortem cross-sectional imaging that focuses on unenhanced PMCT and PMCTA. This review should facilitate the implementation of a high-quality protocol that enables standardized reporting in morgues, associated hospitals or private practices that perform forensic scans to provide the same quality that clinical scans provide in court.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE In traumatic brain injury, diffusion-weighted and diffusion tensor imaging of the brain are essential techniques for determining the pathology sustained and the outcome. Postmortem cross-sectional imaging is an established adjunct to forensic autopsy in death investigation. The purpose of this prospective study was to evaluate postmortem diffusion tensor imaging in forensics for its feasibility, influencing factors and correlation to the cause of death compared with autopsy. METHODS Postmortem computed tomography, magnetic resonance imaging, and diffusion tensor imaging with fiber tracking were performed in 10 deceased subjects. The Likert scale grading of colored fractional anisotropy maps was correlated to the body temperature and intracranial pathology to assess the diagnostic feasibility of postmortem diffusion tensor imaging and fiber tracking. RESULTS Optimal fiber tracking (>15,000 fiber tracts) was achieved with a body temperature at 10°C. Likert scale grading showed no linear correlation (P > 0.7) to fiber tract counts. No statistically significant correlation between total fiber count and postmortem interval could be observed (P = 0.122). Postmortem diffusion tensor imaging and fiber tracking allowed for radiological diagnosis in cases with shearing injuries but was impaired in cases with pneumencephalon and intracerebral mass hemorrhage. CONCLUSIONS Postmortem diffusion tensor imaging with fiber tracking provides an exceptional in situ insight "deep into the fibers" of the brain with diagnostic benefit in traumatic brain injury and axonal injuries in the assessment of the underlying cause of death, considering influencing factors for optimal imaging technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighted imaging (DWI) is an established diagnostic tool with regards to the central nervous system (CNS) and research into its application in the musculoskeletal system has been growing. It has been shown that DWI has utility in differentiating vertebral compression fractures from malignant ones, assessing partial and complete tears of the anterior cruciate ligament (ACL), monitoring tumor response to therapy, and characterization of soft-tissue and bone tumors. DWI is however less useful in differentiating malignant vs. infectious processes. As of yet, no definitive qualitative or quantitative properties have been established due to reasons ranging from variability in acquisition protocols to overlapping imaging characteristics. Even with these limitations, DWI can still provide clinically useful information, increasing diagnostic accuracy and improving patient management when magnetic resonance imaging (MRI) findings are inconclusive. The purpose of this article is to summarize recent research into DWI applications in the musculoskeletal system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple nonmorphologic magnetic resonance sequences are available in musculoskeletal imaging that can provide additional information to better characterize and diagnose musculoskeletal disorders and diseases. These sequences include blood-oxygen-level-dependent (BOLD), arterial spin labeling (ASL), diffusion-weighted imaging (DWI), and diffusion-tensor imaging (DTI). BOLD and ASL provide different methods to evaluate skeletal muscle microperfusion. The BOLD signal reflects the ratio between oxyhemoglobin and deoxyhemoglobin. ASL uses selective tagging of inflowing blood spins in a specific region for calculating local perfusion. DWI and DTI provide information about the structural integrity of soft tissue including muscles and fibers as well as pathologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A integração de sistemas é um tema sempre actual na temática das tecnologias de informação. Desde há muito tempo que as grandes empresas identificaram a necessidade de integrar dados de diferentes sistemas, criando mais valor para os seus negócios. Alguns sectores da indústria estão claramente mais avançados do que outros no que diz respeito à integração de sistemas. Alguns factores, como a concorrência e competitividade mais agressiva em alguns mercados, foram os catalisadores desses avanços tecnológicos. A indústria da saúde não foi, infelizmente, um dos sectores onde se registaram grandes avanços na integração de sistemas. Foi, no entanto, onde se registou uma explosão de normas e protocolos que suportam as diversas disciplinas da medicina, como por ex, a Radiologia. Essas normas e protocolos permitiram dotar a medicina de meios mais rigorosos de produzir diagnósticos e encontrar curas para as mais diversas patologias. Existem muitos produtos que adoptam estas normas. As organizações foram, progressivamente, adquirindo esses produtos mas sem grande preocupação da eventual necessidade da integração. A disciplina da Radiologia é uma das disciplinas onde se verifica, ainda hoje, uma enorme diversidade de equipamentos e sistemas de informação mas onde se encontra desafios consideráveis no que diz respeito à integração. Foram esses desafios que despoletaram o interesse de investigação e cujos resultados se partilham nesta dissertação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mode of access: Internet.