938 resultados para Prosthesis Fitting
Resumo:
Coxian phase-type distributions are becoming a popular means of representing survival times within a health care environment. They are favoured as they show a distribution as a system of phases and can allow for an easy visual representation of the rate of flow of patients through a system. Difficulties arise, however, in determining the parameter estimates of the Coxian phase-type distribution. This paper examines ways of making the fitting of the Coxian phase-type distribution less cumbersome by outlining different software packages and algorithms available to perform the fit and assessing their capabilities through a number of performance measures. The performance measures rate each of the methods and help in identifying the more efficient. Conclusions drawn from these performance measures suggest SAS to be the most robust package. It has a high rate of convergence in each of the four example model fits considered, short computational times, detailed output, convergence criteria options, along with a succinct ability to switch between different algorithms.
Resumo:
Background: Small molecule inhibitors of the zinc finger domain (ZFI) in the nucleocapsid protein (NCp7) of HIV-1 are potent inhibitors of HIV and SIV
replication and may have utility as topical products to prevent infection. Furthermore, intravaginal rings (IVRs) were developed as coitally-independent,
sustained release devices which could be used for administration of HIV microbicides. The aims of these studies were to demonstrate that IVRs sized for
macaques are practical and compatible with the current generation of thioester-based NCp7 inhibitors.
Methods: Non-medicated silicone elastomer vaginal rings of various sizes thought to be applicable for macaques were prepared and tested for vaginal fit in Pigtailed and Chinese Rhesus macaques. Macaques were monitored for 8 weeks for mucosal disruption by colposcopy and proinflammatory cytokine markers in cervical vaginal lavages (CVL) using Luminex bead-based technology. Three different ZFIs (compounds 52, 89 and 122, each derived from an N-substituted S-acyl-2-mercaptobenzamide thioester scaffold) were loaded at 50 mg into an optimal matrix-type ring design. In vitro continuous release studies were then conducted over 28 days and analyzed by HPLC. Rate of release was determined by linear regression analysis.
Results: Qualitative evaluation at the time of ring insertion suggested that the 25 mm ring provided optimal fit in both macaque species. All rings remained in
place during the study period (2 to 4 weeks), and the animals did not attempt to remove the rings. No tissue irritation was observed, and no signs of physical
discomfort were noted. Also, no significant induction of cervicovaginal proinflammatory markers was observed during the 8-week period during and following ring insertion. One Pigtailed macaque showed elevated IL-8 levels in the CVL during the period when the ring was in place; however, these levels were comparable to those observed in two control macaques. In vitro release of the ZFIs peaked at day 1 and then continually declined to near steady-state rates between 20-30 mcg/day. The percent release after 14 days was 2.9, 2.0 and 0.9 for ZFI 89, 52 and 122, respectively.
Conclusions: IVRs of 25mm diameter, determined to be the optimal size for macaques, were well tolerated and did not induce inflammation. Release of all ZFI compounds followed t 0.5 kinetics. These findings suggest that efficacy testing in primate models is warranted to fully evaluate the potential to prevent
transmission.
Resumo:
DESIGN: A multi-centre randomised controlled study in 14 dental schools. This report is an interim analysis at 3 years.
INTERVENTION: Patients were allocated to either the Removable dental prosthesis group (RPD)-109 patients or the no prosthesis group (SDA) -106 patients. Patients had to be older than 35 years with no molars in the study jaw. Follow-up visits were scheduled at 4 to 8 wks (baseline), at 6 months, and at 1, 2, 3, 4, and 5 yrs after treatment.
OUTCOME MEASURE: Time to loss of first tooth following intervention or no intervention.
RESULTS: 81 patients received a RDP and 69 patients received no treatment in the end. This is a reduction of 26% and 35% respectively from the time when they were randomised to the two groups. Tooth loss occurred in 13 of the RDP group (16% of those who received the RDP, 12% of those allocated to the group at the start) with 5 of these being in the study jaw and 8 in the opposing jaw. Tooth loss occurred in 9 of the SDA group (13% of those who received SDA, 9% of those who were allocated to the group at the start) with 5 in the study jaw and 4 in the opposing jaw. The respective Kaplan-Meier survival rates at 38 months were 0.83 (95% CI: 0.74-0.91) in the RDP group and 0.86 (95% CI: 0.78-0.95) in the SDA group.
CONCLUSIONS: The difference in tooth loss at three years between patients treated with RDP and those not treated with RDP was not significant.
Resumo:
This case report details the successful rehabilitation of an edentulous patient using a complete upper prosthesis and a lower implant retained overdenture. The provision of care was split between a specialist centre and a primary care setting. This approach reduced inconvenience to the patient. Modern surgical and prosthodontic techniques also reduced the total delivery time. After initial consultation a new set of complete dentures was prescribed with changes in design to the originals. The patient was also planned for placement of two mandibular implants to stabilise and retain the mandibular denture. The first line of treatment involved provision of a new set of dentures constructed by the patient's general dental practitioner. Dental implants were then placed in a specialist centre and the patient returned to the dental practice for attachment of the lower denture to the dental implants. The benefits and success of mandibular implant retained dentures are well documented. With delivery of the overdenture, the patient reported increased satisfaction with his prostheses which allowed him to eat a greater range of foods and enabled him to feel confident when speaking and socialising.
Resumo:
Affiliation: Institut de recherche en immunologie et en cancérologie, Université de Montréal
Resumo:
This paper discusses a study to investigate the possibility of quantifying and analyzing the speech of cleft palate subjects.
Resumo:
This paper is a review of hearing aid practices in Mexico.
Resumo:
Combinations of drugs are increasingly being used for a wide variety of diseases and conditions. A pre-clinical study may allow the investigation of the response at a large number of dose combinations. In determining the response to a drug combination, interest may lie in seeking evidence of synergism, in which the joint action is greater than the actions of the individual drugs, or of antagonism, in which it is less. Two well-known response surface models representing no interaction are Loewe additivity and Bliss independence, and Loewe or Bliss synergism or antagonism is defined relative to these. We illustrate an approach to fitting these models for the case in which the marginal single drug dose-response relationships are represented by four-parameter logistic curves with common upper and lower limits, and where the response variable is normally distributed with a common variance about the dose-response curve. When the dose-response curves are not parallel, the relative potency of the two drugs varies according to the magnitude of the desired effect and the models for Loewe additivity and synergism/antagonism cannot be explicitly expressed. We present an iterative approach to fitting these models without the assumption of parallel dose-response curves. A goodness-of-fit test based on residuals is also described. Implementation using the SAS NLIN procedure is illustrated using data from a pre-clinical study. Copyright © 2007 John Wiley & Sons, Ltd.
Resumo:
This paper specifically examines the implantation of a microelectrode array into the median nerve of the left arm of a healthy male volunteer. The objective was to establish a bi-directional link between the human nervous system and a computer, via a unique interface module. This is the first time that such a device has been used with a healthy human. The aim of the study was to assess the efficacy, compatibility, and long term operability of the neural implant in allowing the subject to perceive feedback stimulation and for neural activity to be detected and processed such that the subject could interact with remote technologies. A case study demonstrating real-time control of an instrumented prosthetic hand by means of the bi-directional link is given. The implantation did not result in infection, and scanning electron microscope images of the implant post extraction have not indicated significant rejection of the implant by the body. No perceivable loss of hand sensation or motion control was experienced by the subject while the implant was in place, and further testing of the subject following the removal of the implant has not indicated any measurable long term defects. The implant was extracted after 96 days. Copyright © 2004 John Wiley & Sons, Ltd.