945 resultados para Power-factor-correction techniques


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Connectivity analysis on diffusion MRI data of the whole- brain suffers from distortions caused by the standard echo- planar imaging acquisition strategies. These images show characteristic geometrical deformations and signal destruction that are an important drawback limiting the success of tractography algorithms. Several retrospective correction techniques are readily available. In this work, we use a digital phantom designed for the evaluation of connectivity pipelines. We subject the phantom to a âeurooetheoretically correctâeuro and plausible deformation that resembles the artifact under investigation. We correct data back, with three standard methodologies (namely fieldmap-based, reversed encoding-based, and registration- based). Finally, we rank the methods based on their geometrical accuracy, the dropout compensation, and their impact on the resulting connectivity matrices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We study the workings of the factor analysis of high-dimensional data using artificial series generated from a large, multi-sector dynamic stochastic general equilibrium (DSGE) model. The objective is to use the DSGE model as a laboratory that allow us to shed some light on the practical benefits and limitations of using factor analysis techniques on economic data. We explain in what sense the artificial data can be thought of having a factor structure, study the theoretical and finite sample properties of the principal components estimates of the factor space, investigate the substantive reason(s) for the good performance of di¤usion index forecasts, and assess the quality of the factor analysis of highly dissagregated data. In all our exercises, we explain the precise relationship between the factors and the basic macroeconomic shocks postulated by the model.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Les analyses effectuées dans le cadre de ce mémoire ont été réalisées à l'aide du module MatchIt disponible sous l’environnent d'analyse statistique R. / Statistical analyzes of this thesis were performed using the MatchIt package available in the statistical analysis environment R.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho investiga basicamente a validade do Teste Illinois de Habilidades Psicolinguísticas -ITPA -instrumento de avaliação do desenvolvimento da linguagem infantil. Seus autores, S. Kirk e J.J. McCarthy (1961), utilizam o referencial teórico proposto por C. Osgood (1957), a ele incorporando o modelo derivado da Teoria da Informação, o que permite que, na prática clínica, o ITPA possa ser incluído no processo psicodiagnóstico como instrumento de avaliação dos problemas da comunicação em crianças entre três e dez anos. Os objetivos que conduzem e orientam o trabalho apresentado podem ser definidos em três níveis: 1) O que trata dos constructos e suas interrelaç6es -análise crítica da validade teóricado ITPA; 2) O que avalia sua condição de instrumento diagnóstico do desempenho escolar -sensibilidade discriminante do rendimento acadêmico; 3) O que trata da eficácia da prática psicopedagógica proposta pelo mesmo instrumento. O estudo sobre a validade teórica foi realizado com 931 crianças entre três e dez anos de idade, em processo de escolarização, frequentando creches, jardins de infância ou classes regulares da Rede de Ensino do Primeiro Grau no Município do Rio de Janeiro. Utilizou-se a técnica da Análise Fatorial, complementada por uma abordagem lógica que comprovaram algumas das dimensões propostas pelo referencial teórico de Kirk e McCarthy. Para a validade diagnóstica foram avaliadas 71 crianças com dificuldades no desempenho acadêmico, expressas através de conceitos de insuficiência ou deficiência de rendimento e seus resultados foram comparados com os de um subgrupo, aleatoriamente constituído de crianças que participaram do estudo anterior. Utilizou-se a técnica da Análise Discriminante chegando-se à seguinte conclusão: embora a validade de constructo do IIPA não tenha sido completamente confirmada num nível diagnóstico os resultados permitem identificar, com baixa margem de erro, as crianças que pertencem a um ou outro dos grupos de contraste. Quanto ao terceiro nível, foi feita ampla-revelação bibliográfica sobre investigações efetuadas com este instrumento no Brasil e no Exterior. Visou-se avaliar a eficácia da prática psicopedagógica utilizada quando desenvolvida à luz dos recursos de intervenção que o IIPA propõe. Concluiu-se que as pesquisas, até o presente momento efetuadas, não são suficientes para formar um juízo mais seguro da praxis educativa destinada à reabilitação das crianças com problemas da comunicação - o que constitui impedimento a seu desempenho acadêmico - em função das controvérsias que tais pesquisas apresentam.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The past decade has wítenessed a series of (well accepted and defined) financial crises periods in the world economy. Most of these events aI,"e country specific and eventually spreaded out across neighbor countries, with the concept of vicinity extrapolating the geographic maps and entering the contagion maps. Unfortunately, what contagion represents and how to measure it are still unanswered questions. In this article we measure the transmission of shocks by cross-market correlation\ coefficients following Forbes and Rigobon's (2000) notion of shift-contagion,. Our main contribution relies upon the use of traditional factor model techniques combined with stochastic volatility mo deIs to study the dependence among Latin American stock price indexes and the North American indexo More specifically, we concentrate on situations where the factor variances are modeled by a multivariate stochastic volatility structure. From a theoretical perspective, we improve currently available methodology by allowing the factor loadings, in the factor model structure, to have a time-varying structure and to capture changes in the series' weights over time. By doing this, we believe that changes and interventions experienced by those five countries are well accommodated by our models which learns and adapts reasonably fast to those economic and idiosyncratic shocks. We empirically show that the time varying covariance structure can be modeled by one or two common factors and that some sort of contagion is present in most of the series' covariances during periods of economical instability, or crisis. Open issues on real time implementation and natural model comparisons are thoroughly discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two Macusanite pebbles (MB1 and MB2) were dated with the fission-track method. Six irradiations were carried out in different nuclear reactors: Pavia (Italy), IPEN-CNEN (Brazil) and IPEN-Lima (Peru). Measurements of the thorium and uranium induced-fission per target nucleus using natural thorium thin films and natural U-doped glasses calibrated against natural uranium thin films, together with lambda(F) of 8.46 x 10(-17) a(-1) were used to determine the ages. The apparent ages were corrected using the plateau and size correction methods. Track measurements were performed by different analysts, using different counting criteria. In addition, tracks were measured on samples which had been submitted to thermal treatment as well as on samples which had not been heated. Thermal treatments were carried out to erase the fossil tracks before neutron irradiation. No significant differences have been found in individual results, using the two Macusanite pebbles and the different nuclear reactors, age correction techniques, analysts, track-counting criteria, and thermal treatments before neutron irradiation. The great majority of the results (14/17) is compatible with the Ar-Ar ages of 5.12 +/- 0.11 and 5.10 +/- 0.11 Ma, Macusanite MB1 and MB2, respectively. However, the fission-track ages are systematically less (similar to8%) than the Ar-Ar ages of the two Macusanite samples studied. (C) 2003 Published by Elsevier Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to provide a low cost system of thermal comfort, a common model of home fan, 40 cm diameter size, had its manual four-button control system replaced by an automatic speed control. The new control system has a temperature sensor feeding a microcontroller that, by using an optic coupling, DIAC or TRIAC-based circuit, varies the RMS value of the fan motor input voltage and its speed, according to the room temperature. Over a wide range of velocity, the fan net power and the motor fan input power were measured working under both control system. The temperature of the motor stator and the voltage waveforms were observed too. Measured values analysis showed that the TRIAC-based control system makes the fan motor work at a very low power factor and efficiency values. The worst case is at low velocity range where the higher fan motor stator temperatures were registered. The poor power factor and efficiency and the harmonics signals inserted in the motor input voltage wave by the TRIAC commutation procedure are correlated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The conventional power flow method is considered to be inadequate to obtain the maximum loading point because of the singularity of Jacobian matrix. Continuation methods are efficient tools for solving this kind of problem since different parameterization schemes can be used to avoid such ill-conditioning problems. This paper presents the details of new schemes for the parameterization step of the continuation power flow method. The new parameterization options are based on physical parameters, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and transmission line power losses (real and reactive). The simulation results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) are presented and discussed in the companion paper. The results show that the characteristics of the conventional method are not only preserved but also improved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New parameterization schemes have been proposed by the authors in Part I of this paper. In this part these new options for the parameterization of power flow equations are tested, namely, the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, and the transmission line power losses (real and reactive). These different parameterization schemes can be used to obtain the maximum loading point without ill-conditioning problems, once the singularity of Jacobian matrix is avoided. The results obtained with the new approach for the IEEE test systems (14, 30, 57, and 118 buses) show that the characteristics of the conventional method are not only preserved but also improved. In addition, it is shown that the proposed method and the conventional one can be switched during the tracing of PV curves to determine, with few iterations, all points of the PV curve. Several tests were also carried out to compare the performance of the proposed parameterization schemes for the continuation power flow method with the use of both the secant and tangent predictors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents an improved analysis of a novel Programmable Power-factor-corrected-Based Hybrid Multipulse Power Rectifier (PFC-HMPR) for utility interface of power electronic converters. The proposed hybrid multipulse rectifier is composed of an ordinary three-phase six-pulse diode-bridge rectifier (Graetz bridge) with a parallel connection of single-phase switched converters in each three-phase rectifier leg. In this paper, the authors present a complete discussion about the controlled rectifiers' power contribution and also a complete analysis concerning the total harmonic distortion of current that can be achieved when the proposed converter operates as a conventional 12-pulse rectifier. The mathematical analysis presented in this paper corroborate, with detailed equations, the experimental results of two 6-kW prototypes implemented in a laboratory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel hybrid three-phase rectifier is proposed. It is capable to achieve high input power factor (PF) and low total harmonic input currents distortion (THDI). The proposed hybrid high power rectifier is composed by a standard three-phase six-pulse diode rectifier (Graetz bridge) with a parallel connection of single-phase Sepic rectifiers in each three-phase rectifier leg. Such topology results in a structure capable of programming the input current waveform and providing conditions for obtaining high input power factor and low harmonic current distortion. In order to validate the proposed hybrid rectifier, this work describes its principles, with detailed operation, simulation, experimental results, and discussions on power rating of the required Sepic converters as related to the desired total harmonic current distortion. It is demonstrated that only a fraction of the output power is processed through the Sepic converters, making the proposed solution economically viable for very high power installations, with fast investment payback. Moreover, retrofitting to existing installations is also feasible since the parallel path can be easily controlled by integration with the existing dc-link. A prototype has been implemented in the laboratory and it was fully demonstrated to both operate with excellent performance and be feasibly implemented in higher power applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)