948 resultados para Positron Emission Tomography (PET)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have developed a new projector model specifically tailored for fast list-mode tomographic reconstructions in Positron emission tomography (PET) scanners with parallel planar detectors. The model provides an accurate estimation of the probability distribution of coincidence events defined by pairs of scintillating crystals. This distribution is parameterized with 2D elliptical Gaussian functions defined in planes perpendicular to the main axis of the tube of response (TOR). The parameters of these Gaussian functions have been obtained by fitting Monte Carlo simulations that include positron range, acolinearity of gamma rays, as well as detector attenuation and scatter effects. The proposed model has been applied efficiently to list-mode reconstruction algorithms. Evaluation with Monte Carlo simulations over a rotating high resolution PET scanner indicates that this model allows to obtain better recovery to noise ratio in OSEM (ordered-subsets, expectation-maximization) reconstruction, if compared to list-mode reconstruction with symmetric circular Gaussian TOR model, and histogram-based OSEM with precalculated system matrix using Monte Carlo simulated models and symmetries.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Date of Acceptance: 02/06/2015

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A presença da Medicina Nuclear como modalidade de obtenção de imagens médicas é um dos principais procedimentos utilizados hoje nos centros de saúde, tendo como grande vantagem a capacidade de analisar o comportamento metabólico do paciente, traduzindo-se em diagnósticos precoces. Entretanto, sabe-se que a quantificação em Medicina Nuclear é dificultada por diversos fatores, entre os quais estão a correção de atenuação, espalhamento, algoritmos de reconstrução e modelos assumidos. Neste contexto, o principal objetivo deste projeto foi melhorar a acurácia e a precisão na análise de imagens de PET/CT via processos realísticos e bem controlados. Para esse fim, foi proposta a elaboração de uma estrutura modular, a qual está composta por um conjunto de passos consecutivamente interligados começando com a simulação de phantoms antropomórficos 3D para posteriormente gerar as projeções realísticas PET/CT usando a plataforma GATE (com simulação de Monte Carlo), em seguida é aplicada uma etapa de reconstrução de imagens 3D, na sequência as imagens são filtradas (por meio do filtro de Anscombe/Wiener para a redução de ruído Poisson caraterístico deste tipo de imagens) e, segmentadas (baseados na teoria Fuzzy Connectedness). Uma vez definida a região de interesse (ROI) foram produzidas as Curvas de Atividade de Entrada e Resultante requeridas no processo de análise da dinâmica de compartimentos com o qual foi obtida a quantificação do metabolismo do órgão ou estrutura de estudo. Finalmente, de uma maneira semelhante imagens PET/CT reais fornecidas pelo Instituto do Coração (InCor) do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo (HC-FMUSP) foram analisadas. Portanto, concluiu-se que a etapa de filtragem tridimensional usando o filtro Anscombe/Wiener foi relevante e de alto impacto no processo de quantificação metabólica e em outras etapas importantes do projeto em geral.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Head motion during a Positron Emission Tomography (PET) brain scan can considerably degrade image quality. External motion-tracking devices have proven successful in minimizing this effect, but the associated time, maintenance, and workflow changes inhibit their widespread clinical use. List-mode PET acquisition allows for the retroactive analysis of coincidence events on any time scale throughout a scan, and therefore potentially offers a data-driven motion detection and characterization technique. An algorithm was developed to parse list-mode data, divide the full acquisition into short scan intervals, and calculate the line-of-response (LOR) midpoint average for each interval. These LOR midpoint averages, known as “radioactivity centroids,” were presumed to represent the center of the radioactivity distribution in the scanner, and it was thought that changes in this metric over time would correspond to intra-scan motion.

Several scans were taken of the 3D Hoffman brain phantom on a GE Discovery IQ PET/CT scanner to test the ability of the radioactivity to indicate intra-scan motion. Each scan incrementally surveyed motion in a different degree of freedom (2 translational and 2 rotational). The radioactivity centroids calculated from these scans correlated linearly to phantom positions/orientations. Centroid measurements over 1-second intervals performed on scans with ~1mCi of activity in the center of the field of view had standard deviations of 0.026 cm in the x- and y-dimensions and 0.020 cm in the z-dimension, which demonstrates high precision and repeatability in this metric. Radioactivity centroids are thus shown to successfully represent discrete motions on the submillimeter scale. It is also shown that while the radioactivity centroid can precisely indicate the amount of motion during an acquisition, it fails to distinguish what type of motion occurred.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dynamic positron emission tomography (PET) imaging can be used to track the distribution of injected radio-labelled molecules over time in vivo. This is a powerful technique, which provides researchers and clinicians the opportunity to study the status of healthy and pathological tissue by examining how it processes substances of interest. Widely used tracers include 18F-uorodeoxyglucose, an analog of glucose, which is used as the radiotracer in over ninety percent of PET scans. This radiotracer provides a way of quantifying the distribution of glucose utilisation in vivo. The interpretation of PET time-course data is complicated because the measured signal is a combination of vascular delivery and tissue retention effects. If the arterial time-course is known, the tissue time-course can typically be expressed in terms of a linear convolution between the arterial time-course and the tissue residue function. As the residue represents the amount of tracer remaining in the tissue, this can be thought of as a survival function; these functions been examined in great detail by the statistics community. Kinetic analysis of PET data is concerned with estimation of the residue and associated functionals such as ow, ux and volume of distribution. This thesis presents a Markov chain formulation of blood tissue exchange and explores how this relates to established compartmental forms. A nonparametric approach to the estimation of the residue is examined and the improvement in this model relative to compartmental model is evaluated using simulations and cross-validation techniques. The reference distribution of the test statistics, generated in comparing the models, is also studied. We explore these models further with simulated studies and an FDG-PET dataset from subjects with gliomas, which has previously been analysed with compartmental modelling. We also consider the performance of a recently proposed mixture modelling technique in this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-08

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to investigate the subjective perception of anxiety pre- and post-procedure, and explore the relationship between demographic, clinical variables and cancer patients' anxiety during a positron emission tomography/computed tomography (PET/CT) scan. Two hundred and thirty-two oncological out patients, with clinical indication for performing an (18)F-2-fluoro-2-deoxy-D-glucose ((18)F-FDG) PET/CT scan and attending a nuclear medicine (NM) department, participated in the study. Patients' anxiety and subjective experience of PET/CT were examined using two self-report questionnaires. The pre-procedure questionnaire focused on demographic information, level of knowledge regarding the scan and subjective perception of anxiety before the procedure. The post-procedure questionnaire included the subjective perception anxiety after the procedure, information adequacy and satisfaction with the NM department. The self-reported data indicate that patients were anxious during PET/CT. Furthermore, our data revealed a significant difference between the anxiety pre-procedure and post-procedure (z = -3909, p < 0.05), in which the anxiety pre-procedure has significantly higher values. No significant correlation was found between anxiety and age of the patients, education levels, adequacy of information or satisfaction with the NM Department. Perception of anxiety post-procedure differs between gender (U = 5641, p = 0.033). In conclusion, PET/CT generated anxiety levels in oncological patients, especially before the procedure. Although patients seemed to be satisfied with information delivered by staff and with the NM Department, attention has to be focused on effective interventions strategies that help patients to reduce anxiety.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objectives: Cerebrotendinous xanthomatosis (CTX) is a rare autosomal recessive lipid-storage disease caused by mutations in the CYP27A1. The purpose of this study is to determine the clinical characteristics, neuroimaging and mutation detect in a family with CTX systematically. Methods: Collecting history materials and detecting the routine clinical biochemical tests and imaging examination, and for the first time taking the whole body positron emission tomography (PET)-CT examination for probed in the world to research abnormal metabolism activities in CTX. To observe the effect of treatment with chenodeoxycholic acid (CDCA) and stains before and after the intervention, using serum lipid level detection and neuropsychological evaluation. Genetic testing was carried out to screen the nine exons and exon-intron boundaries about 200-300bq of CYP27A1. Results: A 37-year-old woman with typical clinical characteristics of CTX. Magnetic resonance imaging (MRI) of brain showed bilateral lesions in the dentate nucleus of the cerebellum, then, PET images revealed multiple abnormal hypermetabolism areas at distal tendon, and multifocal areas of hypometabolism in bilateral sides of cerebellar hemispheres, the frontal lobe and temporal lobe. Histopathology reveals accumulation of xanthoma cells and dispersed lipid crystal clefts in xanthomas. In genetic analysis, it shown an insertion of cytosine (77-78insC) located in the first exon of CYP27A1 in the proband. Conclusions: We found that a Chinese patient presented a typical clinical feature of CTX along with clear correlation on both structural and functional imaging had a novel mutation in the CYP27A1 gene.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction Many bilinguals will have had the experience of unintentionally reading something in a language other than the intended one (e.g. MUG to mean mosquito in Dutch rather than a receptacle for a hot drink, as one of the possible intended English meanings), of finding themselves blocked on a word for which many alternatives suggest themselves (but, somewhat annoyingly, not in the right language), of their accent changing when stressed or tired and, occasionally, of starting to speak in a language that is not understood by those around them. These instances where lexical access appears compromised and control over language behavior is reduced hint at the intricate structure of the bilingual lexical architecture and the complexity of the processes by which knowledge is accessed and retrieved. While bilinguals might tend to blame word finding and other language problems on their bilinguality, these difficulties per se are not unique to the bilingual population. However, what is unique, and yet far more common than is appreciated by monolinguals, is the cognitive architecture that subserves bilingual language processing. With bilingualism (and multilingualism) the rule rather than the exception (Grosjean, 1982), this architecture may well be the default structure of the language processing system. As such, it is critical that we understand more fully not only how the processing of more than one language is subserved by the brain, but also how this understanding furthers our knowledge of the cognitive architecture that encapsulates the bilingual mental lexicon. The neurolinguistic approach to bilingualism focuses on determining the manner in which the two (or more) languages are stored in the brain and how they are differentially (or similarly) processed. The underlying assumption is that the acquisition of more than one language requires at the very least a change to or expansion of the existing lexicon, if not the formation of language-specific components, and this is likely to manifest in some way at the physiological level. There are many sources of information, ranging from data on bilingual aphasic patients (Paradis, 1977, 1985, 1997) to lateralization (Vaid, 1983; see Hull & Vaid, 2006, for a review), recordings of event-related potentials (ERPs) (e.g. Ardal et al., 1990; Phillips et al., 2006), and positron emission tomography (PET) and functional magnetic resonance imaging (fMRI) studies of neurologically intact bilinguals (see Indefrey, 2006; Vaid & Hull, 2002, for reviews). Following the consideration of methodological issues and interpretative limitations that characterize these approaches, the chapter focuses on how the application of these approaches has furthered our understanding of (1) selectivity of bilingual lexical access, (2) distinctions between word types in the bilingual lexicon and (3) control processes that enable language selection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Investigated human visual processing of simple two-colour patterns using a delayed match to sample paradigm with positron emission tomography (PET). This study is unique in that the authors specifically designed the visual stimuli to be the same for both pattern and colour recognition with all patterns being abstract shapes not easily verbally coded composed of two-colour combinations. The authors did this to explore those brain regions required for both colour and pattern processing and to separate those areas of activation required for one or the other. 10 right-handed male volunteers aged 18–35 yrs were recruited. The authors found that both tasks activated similar occipital regions, the major difference being more extensive activation in pattern recognition. A right-sided network that involved the inferior parietal lobule, the head of the caudate nucleus, and the pulvinar nucleus of the thalamus was common to both paradigms. Pattern recognition also activated the left temporal pole and right lateral orbital gyrus, whereas colour recognition activated the left fusiform gyrus and several right frontal regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

At St Thomas' Hospital, we have developed a computer program on a Titan graphics supercomputer to plan the stereotactic implantation of iodine-125 seeds for the palliative treatment of recurrent malignant gliomas. Use of the Gill-Thomas-Cosman relocatable frame allows planning and surgery to be carried out at different hospitals on different days. Stereotactic computed tomography (CT) and positron emission tomography (PET) scans are performed and the images transferred to the planning computer. The head, tumour and frame fiducials are outlined on the relevant images, and a three-dimensional model generated. Structures which could interfere with the surgery or radiotherapy, such as major vessels, shunt tubing etc., can also be outlined and included in the display. Catheter target and entry points are set using a three-dimensional cursor controlled by a set of dials attached to the computer. The program calculates and displays the radiation dose distribution within the target volume for various catheter and seed arrangements. The CT co-ordinates of the fiducial rods are used to convert catheter co-ordinates from CT space to frame space and to calculate the catheter insertion angles and depths. The surgically implanted catheters are after-loaded the next day and the seeds left in place for between 4 and 6 days, giving a nominal dose of 50 Gy to the edge of the target volume. 25 patients have been treated so far.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Previous studies have found that the lateral posterior fusiform gyri respond more robustly to pictures of animals than pictures of manmade objects and suggested that these regions encode the visual properties characteristic of animals. We suggest that such effects actually reflect processing demands arising when items with similar representations must be finely discriminated. In a positron emission tomography (PET) study of category verification with colored photographs of animals and vehicles, there was robust animal-specific activation in the lateral posterior fusiform gyri when stimuli were categorized at an intermediate level of specificity (e.g., dog or car). However, when the same photographs were categorized at a more specific level (e.g., Labrador or BMW), these regions responded equally strongly to animals and vehicles. We conclude that the lateral posterior fusiform does not encode domain-specific representations of animals or visual properties characteristic of animals. Instead, these regions are strongly activated whenever an item must be discriminated from many close visual or semantic competitors. Apparent category effects arise because, at an intermediate level of specificity, animals have more visual and semantic competitors than do artifacts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cerebral responses to alternating periods of a control task and a selective letter generation paradigm were investigated with functional Magnetic Resonance Imaging (fMRI). Subjects selectively generated letters from four designated sets of six letters from the English language alphabet, with the instruction that they were not to produce letters in alphabetical order either forward or backward, repeat or alternate letters. Performance during this condition was compared with that of a control condition in which subjects recited the same letters in alphabetical order. Analyses revealed significant and extensive foci of activation in a number of cerebral regions including mid-dorsolateral frontal cortex, inferior frontal gyrus, precuneus, supramarginal gyrus, and cerebellum during the selective letter generation condition. These findings are discussed with respect to recent positron emission tomography (PET) and fMRI studies of verbal working memory and encoding/retrieval in episodic memory.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Metabolic imaging using positron emission tomography (PET) has found increasing clinical use for the management of infiltrating tumours such as glioma. However, the heterogeneous biological nature of tumours and intrinsic treatment resistance in some regions means that knowledge of multiple biological factors is needed for effective treatment planning. For example, the use of 18F-FDOPA to identify infiltrative tumour and 18F-FMISO for localizing hypoxic regions. Performing multiple PET acquisitions is impractical in many clinical settings, but previous studies suggest multiplexed PET imaging could be viable. The fidelity of the two signals is affected by the injection interval, scan timing and injected dose. The contribution of this work is to propose a framework to explicitly trade-off signal fidelity with logistical constraints when designing the imaging protocol. The particular case of estimating 18F-FMISO from a single frame prior to injection of 18F-FDOPA is considered. Theoretical experiments using simulations for typical biological scenarios in humans demonstrate that results comparable to a pair of single-tracer acquisitions can be obtained provided protocol timings are carefully selected. These results were validated using a pre-clinical data set that was synthetically multiplexed. The results indicate that the dual acquisition of 18F-FMISO and 18F-FDOPA could be feasible in the clinical setting. The proposed framework could also be used to design protocols for other tracers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Positron emission tomography (PET) is an imaging technique in which radioactive positron-emitting tracers are used to study biochemical and physiological functions in humans and in animal experiments. The use of PET imaging has increased rapidly in recent years, as have special requirements in the fields of neurology and oncology for the development of syntheses for new, more specific and selective radiotracers. Synthesis development and automation are necessary when high amounts of radioactivity are needed for multiple PET studies. In addition, preclinical studies using experimental animal models are necessary for evaluating the suitability of new PET tracers for humans. For purification and analysing the labelled end-product, an effective radioanalytical method combined with an optimal radioactivity detection technique is of great importance. In this study, a fluorine-18 labelling synthesis method for two tracers was developed and optimized, and the usefulness of these tracers for possible prospective human studies was evaluated. N-(3-[18F]fluoropropyl)-2β-carbomethoxy-3β-(4-fluorophenyl)nortropane ([18F]β-CFT-FP) is a candidate PET tracer for the dopamine transporter (DAT), and 1H-1-(3-[18F]fluoro-2-hydroxypropyl)-2-nitroimidazole ([18F]FMISO) is a well-known hypoxia marker for hypoxic but viable cells in tumours. The methodological aim of this thesis was to evaluate the status of thin-layer chromatography (TLC) combined with proper radioactivity detection measurement systems as a radioanalytical method. Three different detection methods of radioactivity were compared: radioactivity scanning, film autoradiography, and digital photostimulated luminescence (PSL) autoradiography. The fluorine-18 labelling synthesis for [18F]β-CFT-FP was developed and carbon-11 labelled [11C]β-CFT-FP was used to study the specificity of β-CFT-FP for the DAT sites in human post-mortem brain slices. These in vitro studies showed that β-CFT-FP binds to the caudate-putamen, an area rich of DAT. The synthesis of fluorine-18 labelled [18F]FMISO was optimized, and the tracer was prepared using an automated system with good and reproducible yields. In preclinical studies, the action of the radiation sensitizer estramustine phosphate on the radiation treatment and uptake of [18F]FMISO was evaluated, with results of great importance for later human studies. The methodological part of this thesis showed that radioTLC is the method of choice when combined with an appropriate radioactivity detection technique. Digital PSL autoradiography proved to be the most appropriate when compared to the radioactivity scanning and film autoradiography methods. The very high sensitivity, good resolution, and wide dynamic range of digital PSL autoradiography are its advantages in detection of β-emitting radiolabelled substances.