999 resultados para Polymer testing


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over half a million heroin misusers receive oral methadone maintenance treatment world-wide1 but the maintenance prescription of injectable opioid drugs, like heroin, remains controversial. In 1992 Switzerland began a large scale evaluation of heroin and other injectable opiate prescribing that eventually involved 1035 misusers. 2 3 The results of the evaluation have recently been reported.4 These show that it was feasible to provide heroin by intravenous injection at a clinic, up to three times a day, for seven days a week. This was done while maintaining good drug control, good order, client safety, and staff morale. Patients were stabilised on 500 to 600 mg heroin daily without evidence of increasing tolerance. Retention in treatment was 89% at six months and 69% at 18 months.4 The self reported use of non-prescribed heroin fell signifianctly, but other drug use was minimally affected. The death rate was 1% per year, and there were no deaths from overdose among participants . . . [Full text of this article]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the results of an experimental investigation into the fluidized-bed coating of cylindrical metal specimens using two types of thermoplastic powders, Rilsan(R) PA11, a nylon-11 powder produced by Elf Atochem, France and Cotene(TM) 4612, a linear low density polyethylene powder produced by J.R Courtenay (New Zealand). The effects of dipping time, preheat temperature and particle size distribution on coating thickness and surface finish were investigated. Consistent trends in coating thickness growth with dipping time were obtained for both nylon-11 and polyethylene powders with increases in coating thickness with preheat temperature. For the same preheat temperature, the lower melting point of polyethylene results in thicker coatings compared to those of nylon-11. There is a negligible change in the coating thickness for sieved powders compared to that for unsieved powders. A pre-heat temperatures of between 240 degrees C and 300 degrees C is necessary to achieve an acceptable surface finish with both nylon-11 and polyethylene powders. To minimize errors in achieving the desired coating thickness, dipping times shorter than 2 s are not recommended. The use of graphs of coating thickness versus dipping time in combination with the coating surface roughness plots presented in this paper enable the optimal choice of pre-heat temperature and dipping time to achieve acceptable surface finish. (C) 1999 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previous work on generating state machines for the purpose of class testing has not been formally based. There has also been work on deriving state machines from formal specifications for testing non-object-oriented software. We build on this work by presenting a method for deriving a state machine for testing purposes from a formal specification of the class under test. We also show how the resulting state machine can be used as the basis for a test suite developed and executed using an existing framework for class testing. To derive the state machine, we identify the states and possible interactions of the operations of the class under test. The Test Template Framework is used to formally derive the states from the Object-Z specification of the class under test. The transitions of the finite state machine are calculated from the derived states and the class's operations. The formally derived finite state machine is transformed to a ClassBench testgraph, which is used as input to the ClassBench framework to test a C++ implementation of the class. The method is illustrated using a simple bounded queue example.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This field study was a combined chemical and biological investigation of the relative effects of using dispersants to treat oil spills impacting mangrove habitats. The aim of the chemistry was to determine whether dispersant affected the short- or long-term composition of a medium range crude oil (Gippsland) stranded in a tropical mangrove environment in Queensland, Australia. Sediment cores from three replicate plots of each treatment (oil only and oil plus dispersant) were analyzed for total hydrocarbons and for individual molecular markers (alkanes, aromatics, triterpanes, and steranes). Sediments were collected at 2 days, then 1, 7, 13 and 22 months post-spill. Over this time, oil in the six treated plots decreased exponentially from 36.6 +/- 16.5 to 1.2 +/- 0.8 mg/g dry wt. There was no statistical difference in initial oil concentrations, penetration of oil to depth, or in the rates of oil dissipation between oiled or dispersed oil plots. At 13 months, alkanes were >50% degraded, aromatics were similar to 30% degraded based upon ratios of labile to resistant markers. However, there was no change in the triterpane or sterane biomarker signatures of the retained oil. This is of general forensic interest for pollution events. The predominant removal processes were evaporation (less than or equal to 27%) and dissolution (greater than or equal to 56%), with a lag-phase of 1 month before the start of significant microbial degradation (less than or equal to 7%). The most resistant fraction of the oil that remained after 7 months (the higher molecular weight hydrocarbons) correlated with the initial total organic carbon content of the soil. Removal rate in the Queensland mangroves was significantly faster than that observed in the Caribbean and was related to tidal flushing. (C) 1999 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a model of specification-based testing of interactive systems. This model provides the basis for a framework to guide such testing. Interactive systems are traditionally decomposed into a functionality component and a user interface component; this distinction is termed dialogue separation and is the underlying basis for conceptual and architectural models of such systems. Correctness involves both proper behaviour of the user interface and proper computation by the underlying functionality. Specification-based testing is one method used to increase confidence in correctness, but it has had limited application to interactive system development to date.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

H-1- and C-13-NMR spectroscopy and FT-Raman spectroscopy are used to investigate the properties of a polymer gel dosimeter post-irradiation. The polymer gel (PACT) is composed of acrylamide, N,N'-methylene-bisacrylamide, gelatin, and water. The formation of a polyacrylamide network within the gelatin matrix follows a dose dependence nonlinearly correlated to the disappearance of the double bonds from the dissolved monomers within the absorbed dose range of 0-50 Gy. The signal from the gelatin remains constant with irradiation. We show that the NMR spin-spin relaxation times (T-2) of PAGs irradiated to up to 50 Gy measured in a NMR spectrometer and a clinical magnetic resonance imaging scanner can be modeled using the spectroscopic intensity of the growing polymer network. More specifically, we show that the nonlinear T-2 dependence against dose can be understood in terms of the fraction of protons in three different proton pools. (C) 2000 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effects of ionizing radiation in different compositions of polymer gel dosimeters are investigated using FT-Raman spectroscopy and NMR T-2 relaxation times. The dosimeters are manufactured from different concentrations of comonomers (acrylamide and N,N'-methylene-bis-acrylamide) dispersed in different concentrations of an aqueous gelatin matrix. Results are analysed using a model of fast exchange of magnetization between three proton pools. The fraction of protons in each pool is determined using the known chemical composition of the dosimeter and FT-Raman spectroscopy. Based on these results, the physical and chemical processes in interplay in the dosimeters are examined in view of their effect on the changes in T-2 The precipitation of growing macroradicals and the scavenging of free radicals by gelatin are used to explain the rate of polymerization. The model describes the changes in T-2 as a function of the absorbed dose up to 50 Gy for the different compositions. This is expected to aid the theoretical design of new, more efficient dosimeters, since it was demonstrated that the optimum dosimeter (i.e, with the lowest dose resolution) must have a range of relaxation times which match the range of T-2 values which can be determined with the lowest uncertainty using an MRI scanner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The nuclear magnetic resonance (NMR) spin-spin relaxation time (T-2) is related to the radiation-dependent concentration of polymer formed in polymer gel dosimeters manufactured from monomers in an aqueous gelatin matrix. Changes in T-2 with time post-irradiation have been reported in the literature but their nature is not fully understood. We investigated those changes with time after irradiation using FT-Raman spectroscopy and the precise determination of T-2 at high magnetic field in a polymer gel dosimeter, A model of fast exchange of magnetization taking into account ongoing gelation and strengthening of the gelatin matrix as well as the polymerization of the monomers with time is presented. Published data on the changes of T-2 in gelatin gels as a function of post-manufacture time are used and fitted closely by the model presented. The same set of parameters characterizing the variations of T-2 in gelatin gels and the increasing concentration of polymer determined from Fr-Raman spectroscopy are used successfully in the modelling of irradiated polymer gel dosimeters. Minimal variations in T-2 in an irradiated PAG dosimeter are observed after 13 h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for the evaluation of radiotherapy 3D polymer gel dosimeters has been developed using ultrasound to assess the significant structural changes that occur following irradiation of the dosimeters. The ultrasonic parameters of acoustic speed of propagation, attenuation and transmitted signal intensity were measured as a function of absorbed radiation dose. The dose sensitivities for each parameter were determined as 1.8 x 10(-4) s m(-1) Gy(-1), 3.9 dB m(-1) Gy(-1) and 3.2 V-1 Gy(-1) respectively. All parameters displayed a strong variation with absorbed dose that continued beyond absorbed doses of 15 Gy. The ultrasonic measurements demonstrated a significantly larger dynamic range in dose response curves than that achieved with previously published magnetic resonance imaging (MRI) dose response data. It is concluded that ultrasound shows great potential as a technique for the evaluation of polymer gel dosimeters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Off-resonance RF pre-saturation was used to obtain contrast in MRI images of polymer gel dosimeters irradiated to doses up to 50 Gy. Two different polymer gel dosimeters composed of 2-hydroxyethyl-acryl ate or methacrylic acid monomers mixed with N, N'-methylene-bisacrylamide (BIS), dispersed in an aqueous gelatin matrix were evaluated. Radiation-induced polymerization of the co-monomers generates a fast-relaxing insoluble polymer. Saturation of the polymer using off-resonance Gaussian RF pulses prior to a spin-echo read-out with a short echo time leads to contrast that is dependent on the absorbed dose. This contrast is attributed to magnetization transfer (MT) between free water and the polymer, and direct saturation of water was found to be negligible under the prevailing experimental conditions. The usefulness of MT imaging was assessed by computing the dose resolution obtained with this technique. We found a low value of dose resolution over a wide range of doses could be obtained with a single experiment. This is an advantage over multiple spin echo (MSE) experiments using a single echo spacing where an optimal dose resolution is achieved over only very limited ranges of doses. The results suggest MT imaging protocols may be developed into a useful tool for polymer gel dosimetry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Syphilis remains a significant cause of preventable perinatal death in developing countries with many women remaining untested and thus untreated. Syphilis testing in the clinic (on-site testing) may be a useful strategy to overcome this. We studied the impact of on-site syphilis testing on treatment delays and rates, and perinatal mortality. Methods: We conducted a cluster randomised controlled trial among seven pairs of primary healthcare clinics in rural South Africa, comparing on-site testing complemented by laboratory confirmation versus laboratory testing alone. Intervention clinics used the on-site test conducted by primary care nurses, with results and treatment available within an hour. Control clinics sent blood samples to the provincial laboratory, with results returned 2 weeks later. Results: Of 7134 women seeking antenatal care with available test results, 793 (11.1%) tested positive for syphilis. Women at intervention clinics completed treatment 16 days sooner on average (95% confidence interval: 11 to 21), though there was no significant difference in the proportion receiving adequate treatment at intervention (64%) and control (69%) clinics. There was also no significant difference in the proportion experiencing perinatal loss (3.3% v 5.1%; adjusted risk difference: -0.9%; 95% Cl -4.4 to 2.7). Conclusions: Despite reducing treatment delays, the addition of on-site syphilis testing to existing laboratory testing services did not lead to higher treatment rates or reduce perinatal mortality. However on-site testing for syphilis may remain an important option for improving antenatal care in settings where laboratory facilities are not available.