978 resultados para Pilares de edificación


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we discuss the procedures adopted for the design of built-up columns (laced and battened columns). Built-up columns are widely used in steel construction generally when the compression forces are relatively low and the column buckling lengths are large. They are commonly used in industrial buildings, for example, as posts for cladding, or as columns supporting a crane girder. Unlike columns with full section, in the case of built-up columns, it is necessary to evaluate the shear stiffness. In fact, the shear strength leads to a significant reduction of the critical load. In the context of this work, the components of the columns (chords, diagonals, posts, etc.) are formed by cold-formed members. In order to systematize and rationalize the verification of the built-up columns, this work aim to develop a computer program based on the standards NBR 14762, NBR 6355 and Eurocode 3, basically the considerations of the part EN 1993-1-1

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are regulations that establish conditions and enable the design of armor columns. The NBR 6118 features statements relating to the transverse reinforcement as spacing, reinforcement diameters provision in structural elements and others. However, the norm in force does not provide an explicit methodology for the design of stirrups in different situations. We do not propose even a calculation model for this equipment and provides normative considerations for maximum or minimum values of spacings and armor in diameter. It is noteworthy that the classical references also do not provide a calculation routine sizing of transverse reinforcement and only makes the checks as the normative conditions for the given data. Based on this assumption and the problems that may occur in sizing error, both for spacing and for the proposal of the stirrup diameter, this study demonstrates that armor calculation method already established in the literature and then through an intuitive tool and available develops a spreadsheet based on this calculation routine. It takes as reference the one developed by Emil Moersch (1902) and the calculation model proposed by BUFFONI E SILVA (2006). Finally the paper presents a rational design of shear reinforcement and confronts these values with some numerical examples to show its truth

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

São apresentadas análises das recomendações para estimar a resistência ao puncionamento de lajes lisas de acordo com a versão atual da norma brasileira, a NBR 6118:2003, que não considera o efeito da retangularidade de pilares internos, e sua predecessora, a NBR 6118:1980. Em seções transversais retangulares, o índice de polarização das tensões de cisalhamento é crescente. Isto altera a forma de ruptura da laje, já que a punção se inicia em torno das extremidades da seção do pilar, não se estendendo para os lados maiores, como prescreve a norma, comportamento este que reduz a resistência última das lajes frente às estimativas normativas. São apresentados os resultados de uma análise numérica por elementos finitos (M.E.F.) e uma proposta para melhorar a ductilidade das lajes lisas através das dimensões mínimas dos pilares. Observou-se que a NBR 6118:1980 mostrou-se conservadora e que as estimativas da NBR 6118: 2003 podem ser melhoradas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we discuss the procedures adopted for the design of built-up columns (laced and battened columns). Built-up columns are widely used in steel construction generally when the compression forces are relatively low and the column buckling lengths are large. They are commonly used in industrial buildings, for example, as posts for cladding, or as columns supporting a crane girder. Unlike columns with full section, in the case of built-up columns, it is necessary to evaluate the shear stiffness. In fact, the shear strength leads to a significant reduction of the critical load. In the context of this work, the components of the columns (chords, diagonals, posts, etc.) are formed by cold-formed members. In order to systematize and rationalize the verification of the built-up columns, this work aim to develop a computer program based on the standards NBR 14762, NBR 6355 and Eurocode 3, basically the considerations of the part EN 1993-1-1

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are regulations that establish conditions and enable the design of armor columns. The NBR 6118 features statements relating to the transverse reinforcement as spacing, reinforcement diameters provision in structural elements and others. However, the norm in force does not provide an explicit methodology for the design of stirrups in different situations. We do not propose even a calculation model for this equipment and provides normative considerations for maximum or minimum values of spacings and armor in diameter. It is noteworthy that the classical references also do not provide a calculation routine sizing of transverse reinforcement and only makes the checks as the normative conditions for the given data. Based on this assumption and the problems that may occur in sizing error, both for spacing and for the proposal of the stirrup diameter, this study demonstrates that armor calculation method already established in the literature and then through an intuitive tool and available develops a spreadsheet based on this calculation routine. It takes as reference the one developed by Emil Moersch (1902) and the calculation model proposed by BUFFONI E SILVA (2006). Finally the paper presents a rational design of shear reinforcement and confronts these values with some numerical examples to show its truth

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Colección Introducción a los conceptos de análisis y diseño estructural en las construcciones arquitectónicas.Temas docentes de estructuras VIII

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[ES]La intervención trata de rehabilitar los edificios de la Vega de San José (Las Palmas de Gran Canaria) y su entorno. Agrupamos la edificación en manzanas, reorganizando el territorio mediante ámbitos de privacidad. Sobre el edificio a desarrollar mantenemos la estructura preexistente de pilares de hormigón armado y forjados de viguetas y bovedillas y organizamos la planta con una nueva distrubución (tirando los tabiques que existen). Ampliamos la vivienda con unas cajas mediante placas de anclaje, reforzando los pilares que quedan en contacto.