838 resultados para Physiological optics.
Resumo:
Purpose: A clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500 (Japan) was performed to evaluate validity and repeatability compared with non-cycloplegic subjective refraction and Javal–Schiotz keratometry. An investigation into the dynamic recording capabilities of the instrument was also conducted. Methods: Refractive error measurements were obtained from 150 eyes of 75 subjects (aged 25.12 ± 9.03 years), subjectively by a masked optometrist, and objectively with the WAM-5500 at a second session. Keratometry measurements from the WAM-5500 were compared to Javal–Schiotz readings. Intratest variability was examined on all subjects, whilst intertest variability was assessed on a subgroup of 44 eyes 7–14 days after the initial objective measures. The accuracy of the dynamic recording mode of the instrument and its tolerance to longitudinal movement was evaluated using a model eye. An additional evaluation of the dynamic mode was performed using a human eye in relaxed and accommodated states. Results: Refractive error determined by the WAM-5500 was found to be very similar (p = 0.77) to subjective refraction (difference, -0.01 ± 0.38 D). The instrument was accurate and reliable over a wide range of refractive errors (-6.38 to +4.88 D). WAM-5500 keratometry values were steeper by approximately 0.05 mm in both the vertical and horizontal meridians. High intertest repeatability was demonstrated for all parameters measured: for sphere, cylinder power and MSE, over 90% of retest values fell within ±0.50 D of initial testing. In dynamic (high-speed) mode, the root-mean-square of the fluctuations was 0.005 ± 0.0005 D and a high level of recording accuracy was maintained when the measurement ring was significantly blurred by longitudinal movement of the instrument head. Conclusion: The WAM-5500 Auto Ref/Keratometer represents a reliable and valid objective refraction tool for general optometric practice, with important additional features allowing pupil size determination and easy conversion into high-speed mode, increasing its usefulness post-surgically following accommodating intra-ocular lens implantation, and as a research tool in the study of accommodation.
Resumo:
The optometric profession in the UK has a major role in the detection, assessment and management of ocular anomalies in children between 5 and 16 years of age. The role complements a variety of associated screening services provided across several health care sectors. The review examines the evidence-base for the content, provision and efficacy of these screening services in terms of the prevalence of anomalies such as refractive error, amblyopia, binocular vision and colour vision and considers the consequences of their curtailment. Vision screening must focus on pre-school children if the aim of the screening is to detect and treat conditions that may lead to amblyopia, whereas if the aim is to detect and correct significant refractive errors (not likely to lead to amblyopia) then it would be expedient for the optometric profession to act as the major provider of refractive (and colour vision) screening at 5-6 years of age. Myopia is the refractive error most likely to develop during primary school presenting typically between 8 and 12 years of age, thus screening at entry to secondary school is warranted. Given the inevitable restriction on resources for health care, establishing screening at 5 and 11 years of age, with exclusion of any subsequent screening, is the preferred option. © 2004 The College of Optometrists.
Resumo:
Aim: To determine the best method of estimating the optimum magnification needed by visually impaired patients. Methods: The magnification of low vision aids prescribed to 187 presbyopic visually impaired patients for reading newspapers or books was compared with logMAR distance and near acuity (at 25 cm) and magnification predicted by +4 D step near additions. Results: Distance letter (r = 0.58) and near word visual acuity (r = 0.67) were strongly correlated to the prescribed magnification as were predictive formulae based on these measures. Prediction using the effect of proximal magnification resulted in a similar correlation (r = 0.67) and prediction was poorer in those who did not benefit from proximal magnification. The difference between prescribed and predicted magnification was found to be unrelated to the condition causing visual impairment (F = 2.57, p = 0.08), the central visual field status (F = 0.57, p = 0.57) and patient psychology (F = 0.44, p = 0.51), but was higher in those prescribed stand magnifiers than high near additions (F = 5.99, p < 0.01). Conclusions: The magnification necessary to perform normal visual tasks can be predicted in the majority of cases using visual acuity measures, although measuring the effect of proximal magnification demonstrates the effect of stronger glasses and identifies those in whom prescribed magnification is more difficult to predict.
Resumo:
The visual evoked magnetic response to half-field stimulation using pattern reversal was studied using a d.c. SQUID coupled to a second order gradiometer. The main component of the magnetic response consisted of a positive wave at around 100 ms (P100M). At the time this component was present the response to half-field stimulation consisted of an outgoing magnetic field contralateral and extending to the midline. When the left half field was stimulated the outgoing field was over the posterior right visual cortex and when the right half field was stimulated it was over the left anterior visual cortex. These findings would correctly identify a source located in the contralateral visual cortex. The orientation of the dipoles was not that previously assumed to explain the paradoxical lateralization of the visual evoked potential. The results are discussed in terms of both electrical and magnetic models of the calcarine fissure. © 1992.
Resumo:
The visual evoked magnetic response (VEMR) was measured over the occipital cortex to pattern and flash stimuli in 86 normal subjects aged 15-86 years. The latency of the major positive component (outgoing magnetic field) to the pattern reversal stimulus (P100M) increased with age, particularly after 55 years, while the amplitude of the P100M decreased more gradually over the lifespan. By contrast, the latency of the major positive component to the flash stimulus (P2M) increased more slowly with age after about 50 years, while its amplitude may have decreased in only a proportion of the elderly subjects. The changes in the P100M with age may reflect senile changes in the eye and optic nerve, e.g. senile miosis, degenerative changes in the retina or geniculostriate deficits. The P2M may be more susceptible to senile changes in the visual cortex. The data suggest that the contrast channels of visual information processing deteriorate more rapidly with age than the luminance channels.
Resumo:
Both the eye and brain generate magnetic fields when stimulated with a variety of visual cues. These magnetic fields can be measured with a magnetometer; a device which uses superconducting technology. The application of this technique to measuring the magnetooculogram, magnetoretinogram and visually evoked fields from the brain is described. So far the main use of this technique has been in pure research. Its potential for diagnosing ocular and neurological diseases is discussed.
Resumo:
Despite numerous investigations, the aetiology and mechanism of accommodation and presbyopia remains equivocal. Using Gaussian first-order ray tracing calculations, we examine the contribution that ocular axial distances make to the accommodation response. Further, the influence of age and ametropia are also considered. The data show that all changes in axial distances during accommodation reduce the accommodation response, with the reduction in anterior chamber depth contributing most to this overall attenuation. Although the total power loss due to the changes in axial distances remained constant with increasing age, hyperopes exhibited less accommodation than myopes. The study, therefore, enhances our understanding of biometric accommodative changes and demonstrates the utility of vergence analysis in the assessment of accommodation.
Resumo:
It has long been sought to measure ocular accommodation continuously in human factor applications such as driving or flying. Open-field autorefractors such as the Canon R-1 could be converted to allow continuous, objective recording, but steady eye fixation and head immobilisation were essential for the measurements to be valid. Image analysis techniques utilised by newer open-view autorefractors such as the Shin-Nippon SRW-5000 are more tolerant to head and eye movements, but perhaps the technique with the greatest potential for the measurement of accommodation in human factor applications is photoretinoscopy. This paper examines the development of techniques for high temporal measurements of accommodation and reports on the tolerance of one such recent commercial instrument, the PowerRefractor (PlusOptiX). The instrument was found to be tolerant to eye movements from the optical axis of the instrument (∼0.50 DS change in apparent accommodation with gaze 25° eccentric to the optical axis), longitudinal head movement (<0.25 DS from 8 cm towards and 20 cm away from the correct photorefractor to eye distance) and changes in background illuminance (<0.25 DS from 0.5 to 20 cd m-2 target luminance). The PowerRefractor also quantifies the direction of gaze and pupil size, but is unable to take measurements with small pupils <3.7 ±1.0 mm. © 2002 The College of Optometrists.
Resumo:
Citation information: Armstrong RA, Davies LN, Dunne MCM & Gilmartin B. Statistical guidelines for clinical studies of human vision. Ophthalmic Physiol Opt 2011, 31, 123-136. doi: 10.1111/j.1475-1313.2010.00815.x ABSTRACT: Statistical analysis of data can be complex and different statisticians may disagree as to the correct approach leading to conflict between authors, editors, and reviewers. The objective of this article is to provide some statistical advice for contributors to optometric and ophthalmic journals, to provide advice specifically relevant to clinical studies of human vision, and to recommend statistical analyses that could be used in a variety of circumstances. In submitting an article, in which quantitative data are reported, authors should describe clearly the statistical procedures that they have used and to justify each stage of the analysis. This is especially important if more complex or 'non-standard' analyses have been carried out. The article begins with some general comments relating to data analysis concerning sample size and 'power', hypothesis testing, parametric and non-parametric variables, 'bootstrap methods', one and two-tail testing, and the Bonferroni correction. More specific advice is then given with reference to particular statistical procedures that can be used on a variety of types of data. Where relevant, examples of correct statistical practice are given with reference to recently published articles in the optometric and ophthalmic literature.
Resumo:
Purpose: Recent studies indicate that ocular and scleral rigidity is pertinent to our understanding of glaucoma, age related macular degeneration and the development and pathogenesis of myopia. The principal method of measuring ocular rigidity is by extrapolation of data from corneal indentation tonometry (Ko) using Friedenwald’s transformation algorithms. Using scleral indentation (Schiotz tonometry) we assess whether regional variations in resistance to indentation occur in vivo across the human anterior globe directly, with reference to the deflection of Schiotz scale readings. Methods: Data were collected from both eyes of 26 normal young adult subjects with a range of refractive error (mean spherical equivalent ± S.D. of -1.77 D ± 3.28 D, range -10.56 to +4.38 D). Schiotz tonometry (5.5 g & 7.5 g) was performed on the cornea and four scleral quadrants; supero-temporal (ST) and -nasal (SN), infero-temporal (IT) and -nasal (IN) approximately 8 mm posterior to the limbus. Results: Values of Ko (mm3)-1 were consistent with those previously reported (mean 0.0101 ± 0.0082, range 0.0019–0.0304). In regards to the sclera, significant differences (p < 0.001) were found across quadrants with indentation readings for both loads between means for the cornea and ST; ST and SN; ST and IT, ST and IN. Mean (±S.D.) scale readings for 5.5 g were: cornea 5.93 ± 1.14, ST 8.05 ± 1.58, IT 7.03 ± 1.86, SN 6.25 ± 1.10, IN 6.02 ± 1.49; and 7.5 g: cornea 9.26 ± 1.27, ST 11.56 ± 1.65, IT 10.31 ± 1.74, SN 9.91 ± 1.20, IN 9.50 ± 1.56. Conclusions: Significant regional variation was found in the resistance of the anterior sclera to indentation produced by the Schiotz tonometer.