846 resultados para Physicochemical measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analysis of a major multi-site epidemiologic study of heart disease has required estimation of the pairwise correlation of several measurements across sub-populations. Because the measurements from each sub-population were subject to sampling variability, the Pearson product moment estimator of these correlations produces biased estimates. This paper proposes a model that takes into account within and between sub-population variation, provides algorithms for obtaining maximum likelihood estimates of these correlations and discusses several approaches for obtaining interval estimates. (C) 1997 by John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods. Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/eContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. Results. Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm(3) and 1.11 cm(3), respectively, with absolute limits of agreement ranging from -1.19 cm(3) to + 3.17 cm(3). The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm(3); range, 0.22-0.99 cm(3)) than in survival cases (median, 0.58 cm(3); range, 0.42-0.92 cm(3) [p < 0.011). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. Conclusion. Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose. (C) 2007 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnitude Of functional impairment that may indicate the threshold between MCI and incipient Alzheimer`s disease (AD) has not been clearly defined. The objective was to examine the pattern of functional impairment in the continuum MCI-AD. Eighty-nine older adults (32 cognitively unimpaired, 31 MCI, and 26 AD patients) were examined with the Brazilian version of the Direct Assessment of Functional Status (DAFS-BR) at a University-based memory clinic. MCI patients were sub-divided according to the progression to AD upon follow-up, and had baseline cognitive, functional and biological variables analyzed. MCI patients displayed mild deficits in functional abilities, with intermediate scores as compared to controls and AD. The DAFS-BR items that differentiated MCI from controls involved the ability to deal with finances and shopping skills. At baseline, scores obtained by MCI patients who converted to AD were not significantly different from scores of nonconverters. The magnitude of functional deficits was associated with AD-like pathological findings in the CSF. In conclusion, MCI patients present with early functional changes in complex, instrumental abilities that require the integrity of memory and executive functions. The objective measurement of the functional state may help identify older adults with increased risk of developing dementia in the MCI-AD continuum. (JINS, 2010, 16, 297-305.)

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dorsolateral prefrontal cortex (DLPFC) has been implicated in the pathophysiology of mental disorders. Previous region-of-interest MRI studies that attempted to delineate this region adopted various landmarks and measurement techniques, with inconsistent results. We developed a new region-of-interest measurement method to obtain morphometric data of this region from structural MRI scans, taking into account knowledge from cytoarchitectonic postmortem studies and the large inter-individual variability of this region. MRI scans of 10 subjects were obtained, and DLPFC tracing was performed in the coronal plane by two independent raters using the semi-automated software Brains2. The intra-class correlation coefficients between two independent raters were 0.94 for the left DLPFC and 0.93 for the right DLPFC. The mean +/- S.D. DLPFC volumes were 9.23 +/- 2.35 ml for the left hemisphere and 8.20 +/- 2.08 ml for the right hemisphere. Our proposed method has high inter-rater reliability and is easy to implement, permitting the standardized measurement of this region for clinical research applications. (C) 2009 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this study was to characterize the first 48-hour evolution of metabolic acidosis of adult patients with diabetic ketoacidosis admitted to the intensive care unit. Materials and Methods: We studied 9 patients retrieved from our prospective collected database, using the physicochemical approach to acid-base disturbances. Results: Mean (SD) age was 34 (13) years; mean (SD) Acute Physiology and Chronic Health Evaluation II score was 16 (10); mean (SD) blood glucose level on admission was 480 (144) mg/dL; mean (SD) pH was 7.17 (0.18); and mean (SD) standard base excess was -16.8 (7.7) mEq/L. On admission, a great part of metabolic acidosis was attributed to unmeasured anions (strong ion gap [SIG], 20 +/- 10 mEq/L), with a wide range of strong ion difference (41 +/- 10 mEq/L). During the first 48 hours of treatment, 297 +/- 180 IU of insulin and 9240 +/- 6505 mL of fluids were used. Metabolic improvement was marked by the normalization of pH, partial correction of standard base excess, and a reduction of hyperglycemia. There was a significant improvement of SIG (7.6 +/- 6.2 mEq/L) and a worsening of strong ion difference acidosis (36 +/- 5 mEq/L) in the first 24 hours, with a trend toward recuperation between 24 and 48 hours (38 +/- 6 mEq/L). Conclusion: Initial metabolic acidosis was due to SIG, and the treatment was associated with a significant decrease of SIG with an elevation of serum chloride above the normal range. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acidosis is a common and deleterious aspect of maintenance dialysis. Traditionally, it is considered to be an elevated anion gap acidosis caused by the inability to excrete nonvolatile anions. Stewart`s approach made it possible to identify real determinants of the acid-base status and allowed quantification of the components of these disturbances, especially the unmeasured anions. We performed a cross-sectional study to identify and quantify each component of acidosis in hemodialysis maintenance patients. Sixty-four maintenance hemodialysis patients and 14 controls were enrolled in this study. Gasometrical and biochemical analysis were performed before the midweek dialysis session. Quantitative physicochemical analysis was carried out using the Stewart methodology. Hemodialysis patients were found to have mild acidemia (mean pH: 7.33 +/- 0.06 versus 7.41 +/- 0.05) secondary to metabolic acidosis (serum bicarbonate: 18.8 +/- 0.26 versus 25.2 +/- 0.48 mEq/l). The metabolic acidosis was due to retention of unmeasured anions (6.5 +/- 0.29 versus 3.1 +/- 0.62 mEq/l), hyperchloremia (105.1 +/- 0.5 versus 101.8 +/- 0.7 mEq/l), and hyperphosphatemia (5.90 +/- 0.19 versus 3.66 +/- 0.14 mg/dl). Compared with control values, the unmeasured anions and hyperchloremia had a similar acidifying effect (3.4 and 3.3 mEq/l), corresponding to almost 90% of the metabolic acidosis. Unmeasured anions and hyperchloremia are important components of acidosis in maintenance hemodialysis, in addition to phosphorus. Future studies to determine the etiology and consequences of hyperchloremic acidosis are warranted.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Shrimp is a frequent cause of food allergy. Tropomyosin is the major allergen in shrimp, and it shares homology to tropomyosins from other crustaceans, dust mites, cockroach, and parasites. Objective: The aim of this study was to determine the value of detection of IgE to shrimp tropomyosin in the diagnosis of shrimp allergy. Methods: We have studied 35 patients with asthma, rhinitis, or both who were sensitized to Dermatophagoides pteronyssinus. All subjects underwent skin prick testing in addition to double-blind, placebo-controlled food challenges (DBPCFC); oral open challenges; or both with shrimp. Measurements of IgE to shrimp and shrimp tropomyosin were carried out by means of CAP and chimeric ELISA, respectively. Results: Oral challenges confirmed the diagnosis of shrimp allergy in 7 patients. IgE measurement to shrimp tropomyosin was positive in 71.4% of the patients with shrimp allergy. Of the 28 patients without shrimp allergy, only 7.1% (2/28) had IgE to shrimp tropomyosin compared with 25% (7/28) who had IgE to shrimp and 35.7% (10/28) who had positive skin prick test responses to shrimp. Sensitivity was similar for all 3 methods (71.4%); in contrast, specificity of IgE to shrimp tropomyosin (92.8%) was greater than that of IgE to shrimp (75%) and skin prick testing (64.2%). With regard to diagnostic efficiency, measurement of IgE to shrimp tropomyosin was superior to measurement of IgE to shrimp and skin prick testing (88.5%, 74.2%, and 65.7%, respectively). Conclusion: Use of measurements of IgE to shrimp tropomyosin provided added value to the diagnosis of shrimp allergy. (J Allergy Clin Immunol 2010;125:872-8.)