911 resultados para Photoelectronic devices


Relevância:

20.00% 20.00%

Publicador:

Resumo:

CdS nanoparticles exhibit size dependent optical and electrical properties. We report here the photocurrent and I-V characteristic studies of CdS nanoparticle devices. A sizable short circuit photocurrent was observed in the detection range governed by the size of the clusters. We speculate on the mechanisms leading to the photocurrent and emission in these nanometer scale systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electric-motored personal mobility devices (PMDs) are appearing on Australian roads. While legal to import and own, their use is typically illegal for adult riders within the road transport system. However, these devices could provide an answer to traffic congestion by getting people out of cars for short trips (“first-and-last mile” travel). City of Ryde council, Macquarie University, and Transport for NSW examined PMD use within the road transport system. Stage 1 of the project examined PMD use within a controlled pedestrian environment on the Macquarie University campus. Three PMD categories were used: one-wheelers (an electric unicycle, the Solowheel); two-wheelers (an electric scooter, the Egret); and three-wheelers (the Qugo). The two-wheeled PMD was most effective in terms of flexibility. In contrast, the three-wheeled PMD was most effective in terms of speed. One-wheeled PMD riders were very satisfied with their device, especially at speed, but significant training and practice was required. Two-wheeled PMD riders had less difficulty navigating through pedestrian precincts and favoured the manoeuvrability of the device as the relative narrowness of the two-wheeled PMD made it easier to use on a diversity of path widths. The usability of all PMDs was compromised by the weight of the devices, difficulties in ascending steeper gradients, portability, and parking. This was a limited trial, with a small number of participants and within a unique environment. However, agreement has been reached for a Stage 2 extension into the Macquarie Park business precinct for further real-world trials within a fully functional road transport system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential of using mobile devices to increase learner engagement within a small group of at-risk vocational education students was studied through a qualitative case study. It was found that the use of mobile devices could be a strategy educators may use to reduce the barriers these students often encounter within traditional classrooms. Notions of interactivity, ease of use, existing familiarity and fluency were found to be fundamental variables that were central to the group's use of mobile devices. The study provides direction for educators looking for innovative ways to engage students who struggle in a classroom situation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the aim of finding simple methods for the fabrication of He II refilling devices, He II flow has been studied through filters made from various fine powders (oxides and metals, grain sizes in the range 0.05–2 μm) by compacting them under pressure. The results obtained for the different states of He II flow, especially in the “breakthrough” and “easy flow” range, are explained by the fountain effect, He II hydrodynamics and the choking effect. According to the results, pressedpowder filters can be classified into three groups with different flow characteristics, of which the “good transfer filters” with a behaviour neatly described by simple theory are suitable for use in He II refilling devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional comparisons between the capture efficiency of sampling devices have generally looked at the absolute differences between devices. We recommend that the signal-to-noise ratio be used when comparing the capture efficiency of benthic sampling devices. Using the signal-to-noise ratio rather than the absolute difference has the advantages that the variance is taken into account when determining how important the difference is, the hypothesis and minimum detectable difference can be made identical for all taxa, it is independent of the units used for measurement, and the sample-size calculation is independent of the variance. This new technique is illustrated by comparing the capture efficiency of a 0.05 m(2) van Veen grab and an airlift suction device, using samples taken from Heron and One Tree lagoons, Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The estimation of feed efficiency in beef cattle should be undertaken in the environment where the genetic potential of the animal is to be expressed. Consequently if cattle are to be pasture fed, there is a requirement for accurate feed intake measurements on individual animals in the field. This in turn requires the use of accurate faecal marker delivery systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to help broaden the use of electronic portal imaging devices (EPIDs) for pre-treatment patient positioning verification, from photon-beam radiotherapy to photon- and electron-beam radiotherapy, by proposing and testing a method for acquiring clinicallyuseful EPID images of patient anatomy using electron beams, with a view to enabling and encouraging further research in this area. EPID images used in this study were acquired using all available beams from a linac configured to deliver electron beams with nominal energies of 6, 9, 12, 16 and 20 MeV, as well as photon beams with nominal energies of 6 and 10 MV. A widely-available heterogeneous, approximately-humanoid, thorax phantom was used, to provide an indication of the contrast and noise produced when imaging different types of tissue with comparatively realistic thicknesses. The acquired images were automatically calibrated, corrected for the effects of variations in the sensitivity of individual photodiodes, using a flood field image. For electron beam imaging, flood field EPID calibration images were acquired with and without the placement of blocks of water-equivalent plastic (with thicknesses approximately equal to the practical range of electrons in the plastic) placed upstream of the EPID, to filter out the primary electron beam, leaving only the bremsstrahlung photon signal. While the electron beam images acquired using a standard (unfiltered) flood field calibration were observed to be noisy and difficult to interpret, the electron beam images acquired using the filtered flood field calibration showed tissues and bony anatomy with levels of contrast and noise that were similar to the contrast and noise levels seen in the clinically acceptable photon beam EPID images. The best electron beam imaging results (highest contrast, signal-to-noise and contrast-to-noise ratios) were achieved when the images were acquired using the higher energy electron beams (16 and 20 MeV) when the EPID was calibrated using an intermediate (12 MeV) electron beam energy. These results demonstrate the feasibility of acquiring clinically-useful EPID images of patient anatomy using electron beams and suggest important avenues for future investigation, thus enabling and encouraging further research in this area. There is manifest potential for the EPID imaging method proposed in this work to lead to the clinical use of electron beam imaging for geometric verification of electron treatments in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents results from an experimental 10-day research charter that was designed to quantify the effects of a) a turtle excluder device (TED) and b) a radial escape section bycatch reduction device (BRD) and c) both devices together, on prawn and bycatch catch rates in the Queensland shallow water eastern king prawn (Penaeus plebejus) trawl fishery. The bycatch was comprised of 250 taxa, mainly gurnards, whiting, lizard fish, flathead, dragonets, portunid crabs, turretfish and flounders. The observed mean catch rates of bycatch and marketable eastern king prawns from the standard trawl net (i.e., net with no TED or BRD) used during the charter were 11.06 (se 0.90) kg per hectare swept by the trawl gear (ha-1) and 0.94 kg ha-1, respectively. For the range of depths sampled (20.1-90.7 m), bycatch catch rates declined significantly at a rate of 0.14 kg ha-1 for every 1 m increase in depth, while prawn catch rates were unaffected. When both the TED and radial escape section BRD were used together they resulted in a 24% reduction in total bycatch catch rate compared to a standard net, but at a 20% reduction in marketable prawn catch rate. The largest reductions were achieved for stout whiting Sillago robusta (57% reduction) and yellowtail scad Trachurus novaezelandiae (32% reduction). Multidimensional scaling and analysis of similarities revealed that bycatch assemblages differed significantly between depths and latitude, but not between the different combinations of bycatch reduction devices. Despite the lowered prawn catch rates, the reduced bycatch catch rates are promising, particularly for S. robusta which is not permitted to be retained by the prawn trawl fleet and yet experiences considerable incidental fishing mortality, and because it is targeted in a separate licensed commercial fishery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sampling devices differing greatly in shape, size and operating condition have been used to collect air samples to determine rates of emission of volatile substances, including odour. However, physical chemistry principles, in particular the partitioning of volatile substances between two phases as explained by Henrys Law and the relationship between wind velocity and emission rate, suggests that different devices cannot be expected to provide equivalent emission rate estimates. Thus several problems are associated with the use of static and dynamic emission chambers, but the more turbulent devices such as wind tunnels do not appear to be subject to these problems. In general, the ability to relate emission rate estimates obtained from wind tunnel measurements to those derived from device-independent techniques supports the use of wind tunnels to determine emission rates that can be used as input data for dispersion models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two commonly used sampling devices (a wind tunnel and the US EPA dynamic emission chamber), were used to collect paired samples of odorous air from a number of agricultural odour sources. The odour samples were assessed using triangular, forced-choice dynamic olfactometry. The odour concentration data was combined with the flushing rate data to calculate odour emission rates for both devices on all sources. Odour concentrations were consistently higher in samples collected with a flux chamber (ratio ranging from 10:7 to 5:1, relative to wind tunnel samples), whereas odour emission rates were consistently larger when derived from wind tunnels (ratio ranging from 60:1 to 240:1, relative to flux chamber values). A complex relationship existed between emission rate estimates derived from each device, apparently influenced by the nature of the emitting surface. These results have great significance for users of odour dispersion models, for which an odour emission rate is a key input parameter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a low-frequency electrical noise measurement in graphene based field effect transistors. For single layer graphene (SLG), the resistance fluctuations is governed by the screening of the charge impurities by the mobile charges. However, in case of Bilayer graphene (BLG), the electrical noise is strongly connected to its band structure, and unlike single layer graphene, displays a minimum when the gap between the conduction and valence band is zero. Using double gated BLG devices we have tuned the zero gap and charge neutrality points independently, which offers a versatile mechanism to investigate the low-energy band structure, charge localization and screening properties of bilayer graphene

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Online dynamic load modeling has become possible with the availability of Static Voltage Compensator (SVC) and Phasor Measurement Unit (PMU) devices. The power of the load response to the small random bounded voltage fluctuations caused from SVC can be measured by PMU for modelling purposes. The aim of this paper is to illustrate the capability of identifying an aggregated load model from high voltage substation level in the online environment. The induction motor is used as the main test subject since it contributes the majority of the dynamic loads. A test system representing simple electromechanical generator model serving dynamic loads through the transmission network is used to verify the proposed method. Also, dynamic load with multiple induction motors are modeled to achieve a better realistic load representation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis utilises an evidence-based approach to critically evaluate and summarize effectiveness research on physiotherapy, physiotherapy-related motor-based interventions and orthotic devices in children and adolescents with cerebral palsy (CP). It aims to assess the methodological challenges of the systematic reviews and trials, to evaluate the effectiveness of interventions in current use, and to make suggestions for future trials Methods: Systematic reviews were searched from computerized bibliographic databases up to August 2007 for physiotherapy and physiotherapy-related interventions, and up to May 2003 for orthotic devices. Two reviewers independently identified, selected, and assessed the quality of the reviews using the Overview Quality Assessment Questionnaire complemented with decision rules. From a sample of 14 randomized controlled trials (RCT) published between January 1990 and June 2003 we analysed the methods of sampling, recruitment, and comparability of groups; defined the components of a complex intervention; identified outcome measures based on the International Classification of Functioning, Disability and Health (ICF); analysed the clinical interpretation of score changes; and analysed trial reporting using a modified 33-item CONSORT (Consolidated Standards of Reporting Trials) checklist. The effectiveness of physiotherapy and physiotherapy-related interventions in children with diagnosed CP was evaluated in a systematic review of randomised controlled trials that were searched from computerized databases from January 1990 up to February 2007. Two reviewers independently assessed the methodological quality, extracted the data, classified the outcomes using the ICF, and considered the level of evidence according to van Tulder et al. (2003). Results: We identified 21 reviews on physiotherapy and physiotherapy-related interventions and five on orthotic devices. These reviews summarized 23 or 5 randomised controlled trials and 104 or 27 observational studies, respectively. Only six reviews were of high quality. These found some evidence supporting strength training, constraint-induced movement therapy or hippotherapy, and insufficient evidence on comprehensive interventions. Based on the original studies included in the reviews on orthotic devices we found some short-term effects of lower limb casting on passive range of movement, and of ankle-foot orthoses on equinus walk. Long term effects of lower limb orthoses have not been studied. Evidence of upper limb casting or orthoses is conflicting. In the sample of 14 RCTs, most trials used simple randomisation, complemented with matching or stratification, but only three specified the concealed allocation. Numerous studies provided sufficient details on the components of a complex intervention, but the overlap of outcome measures across studies was poor and the clinical interpretation of observed score changes was mostly missing. Almost half (48%) of the applicable CONSORT-based items (range 28 32) were reported adequately. Most reporting inadequacies were in outcome measures, sample size determination, details of the sequence generation, allocation concealment and implementation of the randomization, success of assessor blinding, recruitment and follow-up dates, intention-to-treat analysis, precision of the effect size, co-interventions, and adverse events. The systematic review identified 22 trials on eight intervention categories. Four trials were of high quality. Moderate evidence of effectiveness was established for upper extremity treatments on attained goals, active supination and developmental status, and of constraint-induced therapy on the amount and quality of hand use and new emerging behaviours. Moderate evidence of ineffectiveness was found for strength training's effect on walking speed and stride length. Conflicting evidence was found for strength training's effect on gross motor function. For the other intervention categories the evidence was limited due to the low methodological quality and the statistically insignificant results of the studies. Conclusions: The high-quality reviews provide both supportive and insufficient evidence on some physiotherapy interventions. The poor quality of most reviews calls for caution, although most reviews drew no conclusions on effectiveness due to the poor quality of the primary studies. A considerable number of RCTs of good to fair methodological and reporting quality indicate that informative and well-reported RCTs on complex interventions in children and adolescents with CP are feasible. Nevertheless, methodological improvement is needed in certain areas of the trial design and performance, and the trial authors are encouraged to follow the CONSORT criteria. Based on RCTs we established moderate evidence for some effectiveness of upper extremity training. Due to limitations in methodological quality and variations in population, interventions and outcomes, mostly limited evidence on the effectiveness of most physiotherapy interventions is available to guide clinical practice. Well-designed trials are needed, especially for focused physiotherapy interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous carbon oxygen-reducing electrodes incorporated with perovskite oxide catalysts are reported. It has been possible to fabricate high-performance oxygen-reducing electrodes by introducing La0.5Sr0.5CoO3 and La0.99Sr0.01NiO3 with the activated coconut-shell charcoal; these electrodes could sustain load currents as high as 1 A cm−2 without serious degradation. A model to explain oxygen-reducing activity of these oxides has been proposed.