890 resultados para Phantom Borders
The Other Side of the Fence:Reconceptualizing the “Camp” and Migration Zones at the Borders of Spain
Resumo:
This article explores the dynamics of the space of exception at the borders of Europe in the Spanish enclave of Melilla, and the neighboring Moroccan city of Oujda. Building upon field research conducted in the spring of 2008, I ask how we can understand the political space of migration not simply as exceptional, but as shaped by the mobility of the irregular migrants moving outside of the frameworks, policies, and practices of the state. By privileging the migrant narrative and making use of Rancière's conception of politics as shaped by the demands of those who “have no part,” I suggest an alternative way of understanding the politics of exception and agency of non-citizens—that is, one of disruption and demands to open up powerful potentials for change in an otherwise rigid regime.
Resumo:
This study aims to evaluate the use of Varian radiotherapy dynamic treatment log (DynaLog) files to verify IMRT plan delivery as part of a routine quality assurance procedure. Delivery accuracy in terms of machine performance was quantified by multileaf collimator (MLC) position errors and fluence delivery accuracy for patients receiving intensity modulated radiation therapy (IMRT) treatment. The relationship between machine performance and plan complexity, quantified by the modulation complexity score (MCS) was also investigated. Actual MLC positions and delivered fraction of monitor units (MU), recorded every 50 ms during IMRT delivery, were extracted from the DynaLog files. The planned MLC positions and fractional MU were taken from the record and verify system MLC control file. Planned and delivered beam data were compared to determine leaf position errors with and without the overshoot effect. Analysis was also performed on planned and actual fluence maps reconstructed from the MLC control file and delivered treatment log files respectively. This analysis was performed for all treatment fractions for 5 prostate, 5 prostate and pelvic node (PPN) and 5 head and neck (H&N) IMRT plans, totalling 82 IMRT fields in ∼5500 DynaLog files. The root mean square (RMS) leaf position errors without the overshoot effect were 0.09, 0.26, 0.19 mm for the prostate, PPN and H&N plans respectively, which increased to 0.30, 0.39 and 0.30 mm when the overshoot effect was considered. Average errors were not affected by the overshoot effect and were 0.05, 0.13 and 0.17 mm for prostate, PPN and H&N plans respectively. The percentage of pixels passing fluence map gamma analysis at 3%/3 mm was 99.94 ± 0.25%, which reduced to 91.62 ± 11.39% at 1%/1 mm criterion. Leaf position errors, but not gamma passing rate, were directly related to plan complexity as determined by the MCS. Site specific confidence intervals for average leaf position errors were set at -0.03-0.12 mm for prostate and -0.02-0.28 mm for more complex PPN and H&N plans. For all treatment sites confidence intervals for RMS errors with the overshoot was set at 0-0.50 mm and for the percentage of pixels passing a gamma analysis at 1%/1 mm a confidence interval of 68.83% was set also for all treatment sites. This work demonstrates the successful implementation of treatment log files to validate IMRT deliveries and how dynamic log files can diagnose delivery errors not possible with phantom based QC. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.
Resumo:
Wearable antenna performance measurements were used to characterize a synthetic variable layered phantom testbed, representative of human tissue for operation in the 868/915 MHz, and 2400 MHz industrial, scientific and medical frequency bands. Antenna radiation efficiency measurements on the phantom were compared with measurements on the thorax region of a human test subject. The results show that the phantom is representative of the human body for the application of wireless vital sign monitors, where conductive connections are made to the tissue.
Resumo:
The experience of border crossing for refugees and irregular migrants challenges global border and migration controls in multiple contexts. Using qualitative field research in Tanzania, Spain, Morocco and Australia, Heather Johnson asks how a global regime of migration management and control can be perceived through the dynamics of particular border spaces: refugee camps, border zones and detention centres. She explores how irregular migrants are impacted by the increasingly security-oriented practices of border control, and how they confront these practices. Johnson rejects the characterization of border spaces as exceptional, abject and exclusionary, arguing instead for an understanding of politics as everyday contestation that reveals a radical political agency, re-imagining the global non-citizen as a transgressive and powerful figure. Building on recent scholarship that rethinks irregularity and non-citizenship, her conclusions have broad implications for how we understand irregular migration from a position of dialogue and solidarity.
Resumo:
This article reflects on an on-going research project which aims to expand the understanding of the production and transformation of urban borders in the Eastern European cities of the ex ‘communist bloc’, starting from the case of Sofia. It explores the proposition that there has been a prolific process of wall making in this city associated with ‘vanishing public spaces’, ‘rescaling of enclosure’, and ‘corrosion of the collective urban realm’ (Hirt, 2012). The paper seeks to understand the social and political effects of this process by delving into the sensorial, emotional and embodied experiences associated with the mundane mobilities of urban residents. Using participants’ self-directed photography and videos from ‘walk-along’ interviews it explores the ways in which borders are made visible and are produced, challenged or resisted through mobility, and delves into the associated senses of deepening social and spatial differentiation in the city.
Resumo:
The motivation for this study was to reduce physics workload relating to patient- specific quality assurance (QA). VMAT plan delivery accuracy was determined from analysis of pre- and on-treatment trajectory log files and phantom-based ionization chamber array measurements. The correlation in this combination of measurements for patient-specific QA was investigated. The relationship between delivery errors and plan complexity was investigated as a potential method to further reduce patient-specific QA workload. Thirty VMAT plans from three treatment sites - prostate only, prostate and pelvic node (PPN), and head and neck (H&N) - were retrospectively analyzed in this work. The 2D fluence delivery reconstructed from pretreatment and on-treatment trajectory log files was compared with the planned fluence using gamma analysis. Pretreatment dose delivery verification was also car- ried out using gamma analysis of ionization chamber array measurements compared with calculated doses. Pearson correlations were used to explore any relationship between trajectory log file (pretreatment and on-treatment) and ionization chamber array gamma results (pretreatment). Plan complexity was assessed using the MU/ arc and the modulation complexity score (MCS), with Pearson correlations used to examine any relationships between complexity metrics and plan delivery accu- racy. Trajectory log files were also used to further explore the accuracy of MLC and gantry positions. Pretreatment 1%/1 mm gamma passing rates for trajectory log file analysis were 99.1% (98.7%-99.2%), 99.3% (99.1%-99.5%), and 98.4% (97.3%-98.8%) (median (IQR)) for prostate, PPN, and H&N, respectively, and were significantly correlated to on-treatment trajectory log file gamma results (R = 0.989, p < 0.001). Pretreatment ionization chamber array (2%/2 mm) gamma results were also significantly correlated with on-treatment trajectory log file gamma results (R = 0.623, p < 0.001). Furthermore, all gamma results displayed a significant correlation with MCS (R > 0.57, p < 0.001), but not with MU/arc. Average MLC position and gantry angle errors were 0.001 ± 0.002 mm and 0.025° ± 0.008° over all treatment sites and were not found to affect delivery accuracy. However, vari- ability in MLC speed was found to be directly related to MLC position accuracy. The accuracy of VMAT plan delivery assessed using pretreatment trajectory log file fluence delivery and ionization chamber array measurements were strongly correlated with on-treatment trajectory log file fluence delivery. The strong corre- lation between trajectory log file and phantom-based gamma results demonstrates potential to reduce our current patient-specific QA. Additionally, insight into MLC and gantry position accuracy through trajectory log file analysis and the strong cor- relation between gamma analysis results and the MCS could also provide further methodologies to both optimize the VMAT planning and QA process.
Resumo:
6,000 word state of art essay