979 resultados para Permanent Magnet Generator


Relevância:

80.00% 80.00%

Publicador:

Resumo:

采用单神经元自适应PID控制器对永磁同步电机进行了调速控制。详细介绍了PMSM(PermanentMagnetSynchronousMotor)的矢量控制原理。最后给出PMSM单神经元自适应PID控制的仿真结果和硬件实现方法。仿真结果表明,该系统具有良好的动态性能。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

针对高精度、微进给永磁直线交流同步电机 (PMLSM )驱动系统 ,采用基于模型的扰动抑制 (MBDA)方法 ,对诸如摩擦力、切削力、负载变动之类的扰动进行抑制。MBDA是利用一个与系统并行的标称模型 ,通过输出反馈 ,将系统输出与标称模型输出进行比较 ,得出误差信号 ,并通过设计一个补偿器将误差信号反馈给被控对象的输入端 ,从而实现扰动抑制。同时 ,针对速度环设计了积分 -比例 (IP)控制器 ,以满足系统快速跟踪指令的要求 ,并且其具有较强的抗扰动能力。仿真结果表明 ,该控制方法响应速度快 ,抗干扰能力强

Relevância:

80.00% 80.00%

Publicador:

Resumo:

为了实现水下机器人(UUV,Unmanned Underwater Vehicle)的高精度控制,深入研究了螺旋桨驱动UUV推进系统各个环节运行机理,并建立了它们各自的数学模型,包括PWM模块、直流永磁电机、螺旋桨、舵的数学模型。多功能仿真试验和湖试试验的系统响应曲线基本吻合,一方面表明本文建立的推进系统模型的正确性,另一方面体现了在多功能仿真平台上调试的控制策略和控制器参数具有很大的可信度。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

在电机的设计中,常常需要通过优化设计得到合理的电机结构尺寸和参数.电机的设计问题实质上是一种带约束的复杂的非线性连续函数优化问题.要得到一个满意的优化结果不仅要求算法具有较高的精度,而且要有快的收敛速度.提出一种新的混合算法对永磁电机的尺寸和整体结构进行优化设计.将混沌算法和粒子群算法相结合,以微型永磁电机为例,对槽形等多个变量进行优化,结果证明了算法的有效性和快速性,适合于同类问题求解.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

为中科院沈阳自动化研究所机器人中心研制了海洋救助机器人推进器用钕铁硼永磁直流电动机.针对该电动机设计的特殊性,重点论述电动机功率、电压、转速及主要尺寸的确定方法,主磁极、换向器和电刷装置的设计方法,对电动机的结构特点、电磁性能和实验结果也作了介绍.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

介绍了高精度微进给直线永磁同步电机伺服系统的 IP位置控制 ,提出了对该系统的最优预见前馈补偿 ,以提高系统的跟踪性能。为了能适应系统参数的变化 ,采用自适应神经元来实现预见前馈补偿。自适应神经元的输入向量为预见步数 ,权值为预见前馈系数 ,权值具有明确的物理意义 ,而且权的初始值不是随机数 ,而是系统在额定情况下算出的预见前馈系数 ,从而加快了神经元的调整速度 ,提高了系统的跟踪能力。仿真实验结果证明了所提出方案的有效性

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis explores the use of electromagnetics for both steering and tracking of medical instruments in minimally invasive surgeries. The end application is virtual navigation of the lung for biopsy of early stage cancer nodules. Navigation to the peripheral regions of the lung is difficult due to physical dimensions of the bronchi and current methods have low successes rates for accurate diagnosis. Firstly, the potential use of DC magnetic fields for the actuation of catheter devices with permanently magnetised distal attachments is investigated. Catheter models formed from various materials and magnetic tip formations are used to examine the usefulness of relatively low power and compact electromagnets. The force and torque that can be exerted on a small permanent magnet is shown to be extremely limited. Hence, after this initial investigation we turn our attention to electromagnetic tracking, in the development of a novel, low-cost implementation of a GPS-like system for navigating within a patient. A planar magnetic transmitter, formed on a printed circuit board for a low-profile and low cost manufacture, is used to generate a low frequency magnetic field distribution which is detected by a small induction coil sensor. The field transmitter is controlled by a novel closed-loop system that ensures a highly stable magnetic field with reduced interference from one transmitter coil to another. Efficient demodulation schemes are presented which utilise synchronous detection of each magnetic field component experienced by the sensor. The overall tracking accuracy of the system is shown to be less than 2 mm with an orientation error less than 1°. A novel demodulation implementation using a unique undersampling approach allows the use of reduced sample rates to sample the signals of interest without loss of tracking accuracy. This is advantageous for embedded microcontroller implementations of EM tracking systems. The EM tracking system is demonstrated in the pre-clinical environment of a breathing lung phantom. The airways of the phantom are successfully navigated using the system in combination with a 3D computer model rendered from CT data. Registration is achieved using both a landmark rigid registration method and a hybrid fiducial-free approach. The design of a planar magnetic shield structure for blocking the effects of metallic distortion from below the transmitter is presented which successfully blocks the impact of large ferromagnetic objects such as operating tables. A variety of shielding material are analysed with MuMetal and ferrite both providing excellent shieling performance and an increased signal to noise ratio. Finally, the effect of conductive materials and human tissue on magnetic field measurements is presented. Error due to induced eddy currents and capacitive coupling is shown to severely affect EM tracking accuracy at higher frequencies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The liquid metal flow in induction crucible models is known to be unstable, turbulent and difficult to predict in the regime of medium frequencies when the electromagnetic skin-layer is of considerable extent. We present long term turbulent flow measurements by a permanent magnet incorporated potential difference velocity probe in a cylindrical container filled with eutectic melt In-Ga-Sn. The parallel numerical simulation of the long time scale development of the turbulent average flow is presented. The numerical flow model uses an implicit pseudo-spectral code and k-w turbulence model, which was recently developed for the transitional flow modelling. The results compare reasonably to the experiment and demonstrate the time development of the turbulent flow field and the turbulence energy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The liquid metal flow in inducation crucible models is known to be higly unstable and turbutlen in the regim e of medium frequecies when the elctronmagnetic skin-layer is of considerable extent. We present long term turbulent flow measurements by a permanent magnet incorporated potential difference veolocity probe in a cylindirical container filled with eutecti mlt In-Ga-SN. The parallel numerical simulation of the long time scale development of the turbulen average flow is presented. The numerical lfow model uses a pseud-spectral code and k-w turbulence model, which was recently developed for the transitional flow modelling. The result compare reasonably to the experiment and demonstrate the time development of the turbulent flow field.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Presently, Queens University Belfast is constructing a unique permanent magnet EBIT which grants unparalleled access to the photons from the trap region. However measurements of ions would still require their transfer through the collector to other measurement areas. To allow more representative sampling, a new in situ analyzer is proposed to be situated immediately at the collector end of the trap region. This analyzer may detect ions by expanding the radius of their cyclotron motion using electric fields until the ions strike Microsphere Plates (MSPs). It may also be possible by using trochoidal motion to detect product electrons. This is important as these have never been detected before in an EBIT. The preliminary design is described in this paper. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Gold-coated magnetic nanoparticles were synthesized with size ranging from 15 to 40 nm using sodium citrates as the reducing agent. Oxidized magnetites (Fe3O4) fabricated by co-precipitation of Fe2+ and Fe3+ in strong alkaline solution were used as magnetic cores. The structures of gold (Au) shell and magnetic core (Au–Fe) were studied by transmission electron microscopy (TEM) image and energy dispersive spectroscopy (EDS) spectrum. Results from high-resolution X-ray diffraction (HR XRD) show that the Au–Fe oxide nanoparticles have a face-centered cubic shape with the crystalline faces of {1 1 1}. The Au-coated magnetic nanoparticles exhibited a surface plasmon resonance peak at 528 nm. The nanoparticles are well dispersed in distilled water. A 3000 G permanent magnet was successfully used for the separation of the functionalized nanoparticles. Magnetic properties of the nanoparticles were determined by magnetic force microscope (MFM) in nanometric resolution and vibrating sample magnetometer (VSM). Magnetic separation of biological molecules using Au-coated magnetic oxide composite nanoparticles was examined after attachment of protein immunoglobulin G (IgG) through electrostatic interactions. Using this method, separation was achieved with a maximum yield of 35% at an IgG concentration of 400 ng/ml.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As wind power generation undergoes rapid growth, new technical challenges emerge: dynamic stability and power quality. The influence of wind speed disturbances and a pitch control malfunction on the quality of the energy injected into the electric grid is studied for variable-speed wind turbines with different power-electronic converter topologies. Additionally, a new control strategy is proposed for the variable-speed operation of wind turbines with permanent magnet synchronous generators. The performance of disturbance attenuation and system robustness is ascertained. Simulation results are presented and conclusions are duly drawn. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper is a contribution for the assessment and comparison of magnet properties based on magnetic field characteristics particularly concerning the magnetic induction uniformity in the air gaps. For this aim, a solver was developed and implemented to determine the magnetic field of a magnetic core to be used in Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometry. The electromagnetic field computation is based on a 2D finite-element method (FEM) using both the scalar and the vector potential formulation. Results for the magnetic field lines and the magnetic induction vector in the air gap are presented. The target magnetic induction is 0.2 T, which is a typical requirement of the FFC NMR technique, which can be achieved with a magnetic core based on permanent magnets or coils. In addition, this application requires high magnetic induction uniformity. To achieve this goal, a solution including superconducting pieces is analyzed. Results are compared with a different FEM program.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the optimal design of a sur- face mounted permanent magnet Brushless DC mo- tor (PMBLDC) meant for spacecraft applications. The spacecraft applications requires the choice of a torques motor with high torque density, minimum cogging torque, better positional stability and high torque to inertia ratio. Performance of two types of machine con¯gurations viz Slotted PMBLDC and Slotless PMBLDC with halbach array are compared with the help of analytical and FE methods. It is found that unlike a Slotted PMBLDC motor, the Slotless type with halbach array develops zero cogging torque without reduction in the developed torque. Moreover, the machine being coreless provides high torque to inertia ratio and zero magnetic stiction

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents the design and analysis of a novel machine family of Siotiess Permanent Magnet Brushless DC motors (PMBLDC) for precise positioning applications of spacecrafts. Initial design, selection of major parameters and air gap magnetic flux density are estimated using the analytical model of the machine. The proportion of the halbach array in the machine was optimized using FE to obtain near trapezoidal flux pattern. The novel machine topology is found to deliver high torque density, high efficiency, zero cogging torque, better positional stability, high torque to inertia ratio and zero magnetic stiction suiting space requirements. The machine provides uniform air gap flux density along the radius thus avoiding circulating currents in stator conductors and hence reducing torque ripple