884 resultados para Peripheral fatigue
Resumo:
Objective To evaluate relative telomere length of female migraine patients. Background Migraine is a debilitating disorder affecting 6-28% of the population. Studies on the mechanisms of migraine have demonstrated genetic causes but the pathophysiology and subcellular effects of the disease remain poorly understood. Shortened telomere length is associated with age-related or chronic diseases, and induced stresses. Migraine attacks may impart significant stress on cellular function, thus this study investigates a correlation between shortening of telomeres and migraine. Methods Relative telomere length was measured using a previously described quantitative polymerase chain reaction method. A regression analysis was performed to assess differences in mean relative telomere length between migraine patients and healthy controls. Results The leukocyte telomeres of a cohort of 142 Caucasian female migraine subjects aged 18-77 years and 143 matched 17-77-year-old healthy control Caucasian women were examined.A significantly shorter relative telomere length was observed in the migraine group compared with the control group after adjusting for age and body mass index (P = .001). In addition, age of onset was observed to associate with the loss of relative telomere length, especially at early age of onset (<17 years old). No association was observed between relative telomere length and the severity and frequency of migraine attacks and the duration of migraine. Conclusion Telomeres are shorter in migraine patients and there is more variation in telomere length in migraine patients.
Resumo:
BACKGROUND: US Centers for Disease Control guidelines recommend replacement of peripheral intravenous (IV) catheters no more frequently than every 72 to 96 hours. Routine replacement is thought to reduce the risk of phlebitis and bloodstream infection. Catheter insertion is an unpleasant experience for patients and replacement may be unnecessary if the catheter remains functional and there are no signs of inflammation. Costs associated with routine replacement may be considerable. This is an update of a review first published in 2010. OBJECTIVES: To assess the effects of removing peripheral IV catheters when clinically indicated compared with removing and re-siting the catheter routinely. SEARCH METHODS: For this update the Cochrane Peripheral Vascular Diseases (PVD) Group Trials Search Co-ordinator searched the PVD Specialised Register (December 2012) and CENTRAL (2012, Issue 11). We also searched MEDLINE (last searched October 2012) and clinical trials registries. SELECTION CRITERIA: Randomised controlled trials that compared routine removal of peripheral IV catheters with removal only when clinically indicated in hospitalised or community dwelling patients receiving continuous or intermittent infusions. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial quality and extracted data. MAIN RESULTS: Seven trials with a total of 4895 patients were included in the review. Catheter-related bloodstream infection (CRBSI) was assessed in five trials (4806 patients). There was no significant between group difference in the CRBSI rate (clinically-indicated 1/2365; routine change 2/2441). The risk ratio (RR) was 0.61 but the confidence interval (CI) was wide, creating uncertainty around the estimate (95% CI 0.08 to 4.68; P = 0.64). No difference in phlebitis rates was found whether catheters were changed according to clinical indications or routinely (clinically-indicated 186/2365; 3-day change 166/2441; RR 1.14, 95% CI 0.93 to 1.39). This result was unaffected by whether infusion through the catheter was continuous or intermittent. We also analysed the data by number of device days and again no differences between groups were observed (RR 1.03, 95% CI 0.84 to 1.27; P = 0.75). One trial assessed all-cause bloodstream infection. There was no difference in this outcome between the two groups (clinically-indicated 4/1593 (0.02%); routine change 9/1690 (0.05%); P = 0.21). Cannulation costs were lower by approximately AUD 7.00 in the clinically-indicated group (mean difference (MD) -6.96, 95% CI -9.05 to -4.86; P ≤ 0.00001). AUTHORS' CONCLUSIONS: The review found no evidence to support changing catheters every 72 to 96 hours. Consequently, healthcare organisations may consider changing to a policy whereby catheters are changed only if clinically indicated. This would provide significant cost savings and would spare patients the unnecessary pain of routine re-sites in the absence of clinical indications. To minimise peripheral catheter-related complications, the insertion site should be inspected at each shift change and the catheter removed if signs of inflammation, infiltration, or blockage are present. OBJECTIVES: To assess the effects of removing peripheral IV catheters when clinically indicated compared with removing and re-siting the catheter routinely. SEARCH METHODS: For this update the Cochrane Peripheral Vascular Diseases (PVD) Group Trials Search Co-ordinator searched the PVD Specialised Register (December 2012) and CENTRAL (2012, Issue 11). We also searched MEDLINE (last searched October 2012) and clinical trials registries. SELECTION CRITERIA: Randomised controlled trials that compared routine removal of peripheral IV catheters with removal only when clinically indicated in hospitalised or community dwelling patients receiving continuous or intermittent infusions. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed trial quality and extracted data. MAIN RESULTS: Seven trials with a total of 4895 patients were included in the review. Catheter-related bloodstream infection (CRBSI) was assessed in five trials (4806 patients). There was no significant between group difference in the CRBSI rate (clinically-indicated 1/2365; routine change 2/2441). The risk ratio (RR) was 0.61 but the confidence interval (CI) was wide, creating uncertainty around the estimate (95% CI 0.08 to 4.68; P = 0.64). No difference in phlebitis rates was found whether catheters were changed according to clinical indications or routinely (clinically-indicated 186/2365; 3-day change 166/2441; RR 1.14, 95% CI 0.93 to 1.39). This result was unaffected by whether infusion through the catheter was continuous or intermittent. We also analysed the data by number of device days and again no differences between groups were observed (RR 1.03, 95% CI 0.84 to 1.27; P = 0.75). One trial assessed all-cause bloodstream infection. There was no difference in this outcome between the two groups (clinically-indicated 4/1593 (0.02%); routine change 9/1690 (0.05%); P = 0.21). Cannulation costs were lower by approximately AUD 7.00 in the clinically-indicated group (mean difference (MD) -6.96, 95% CI -9.05 to -4.86; P ≤ 0.00001). AUTHORS' CONCLUSIONS: The review found no evidence to support changing catheters every 72 to 96 hours. Consequently, healthcare organisations may consider changing to a policy whereby catheters are changed only if clinically indicated. This would provide significant cost savings and would spare patients the unnecessary pain of routine re-sites in the absence of clinical indications. To minimise peripheral catheter-related complications, the insertion site should be inspected at each shift change and the catheter removed if signs of inflammation, infiltration, or blockage are present.
Resumo:
Aims and objectives This study sought to determine the relationship between health related quality of life (HRQoL), fatigue and activity levels of people with anaemia secondary to chronic kidney disease (CKD) over a 12 month period following the introduction of an erythropoietin stimulating agent (ESA). Background CKD occurs in five stages and it is a complex chronic illness which severely impacts on an individual’s HRQoL, and ability to perform everyday activities. Fatigue is also a common symptom experienced by people with CKD. Design and methods Using a longitudinal repeated measures design, 28 people with CKD completed the SF-36, human activity profile and fatigue severity scale at the commencement of an ESA and then at 3, 6 and 12 months. Results Over a 12 month period, people reported a significant change in HRQoL in relation to role physical, vitality, mental health/emotional well-being and overall mental health. However activity levels did not significantly improve during that time. Both the amount of breathlessness and level of fatigue were highest at baseline and declined over time. Both fatigue and breathlessness were correlated with less reported general health over time. Conclusion Renal nurses, in dialysis units and CKD outpatient clinics, have repeated and frequent contact with people with CKD over long periods of time, and are in an ideal position to routinely assess fatigue and activity levels and to institute timely interventions. Early detection would enable timely nursing interventions to optimise HRQoL and independent activity. Relevance to Clinical Practice Drawing on rehabilitation nursing interventions could assist renal nurses to minimize the burden of fatigue and its impact on simple everyday activities and a person’s quality of life. These interventions are important for people who are living at home and could assist in lowering the burden on home support services.
Resumo:
Fatigue/sleepiness is recognised as an important contributory factor in fatal and serious injury road traffic incidents (RTIs), however, identifying fatigue/sleepiness as a causal factor remains an uncertain science. Within Australia attending police officers at a RTI report the causal factors; one option is fatigue/sleepiness. In some Australian jurisdictions police incident databases are subject to post hoc analysis using a proxy definition for fatigue/sleepiness. This secondary analysis identifies further RTIs caused by fatigue/sleepiness not initially identified by attending officers. The current study investigates the efficacy of such proxy definitions for attributing fatigue/sleepiness as a RTI causal factor. Over 1600 Australian drivers were surveyed regarding their experience and involvement in fatigue/sleep-related RTIs and near-misses during the past five years. Driving while fatigued/sleepy had been experienced by the majority of participants (66.0% of participants). Fatigue/sleep-related near misses were reported by 19.1% of participants, with 2.4% being involved in a fatigue/sleep-related RTI. Examination of the characteristics for the most recent event (either a near miss or crash) found that the largest proportion of incidents (28.0%) occurred when commuting to or from work, followed by social activities (25.1%), holiday travel (19.8%), or for work purposes (10.1%). The fatigue/sleep related RTI and near-miss experience of a representative sample of Australian drivers does not reflect the proxy definitions used for fatigue/sleepiness identification. In particular those RTIs that occur in urban areas and at slow speeds may not be identified. While important to have a strategy for identifying fatigue/sleepiness related RTIs proxy measures appear best suited to identifying specific subsets of such RTIs.
Resumo:
Low cycle fatigue cracking of light gauge metal roofing was investigated by testing a number of two-span corrugated roofing assemblies with different spans and fastening systems under cyclic uplift wind loading. Fatigue results correlated quite well with the corresponding static results reported earlier, and revealed the dependence of fatigue behaviour on the fastening system used. A comparison was made of one fastening system with the other regarding fatigue performance .
Resumo:
Purpose To investigate hyperopic shifts and the oblique (or 45-degree/135-degree) component of astigmatism at large angles in the horizontal visual field using the Hartmann-Shack technique. Methods The adult participants consisted of 6 hypermetropes, 13 emmetropes and 11 myopes. Measurements were made with a modified COAS-HD Hartmann-Shack aberrometer across T60 degrees along the horizontal visual field in 5-degree steps. Eyes were dilated with 1% cyclopentolate. Peripheral refraction was estimated as mean spherical (or spherical equivalent) refraction, with/against the rule of astigmatism and oblique astigmatism components, and as horizontal and vertical refraction components based on 3-mm major diameter elliptical pupils. Results Thirty percent of eyes showed a pattern that was a combination of type IV and type I patterns of Rempt et al. (Rempt F, Hoogerheide J, Hoogenboom WP. Peripheral retinoscopy and the skiagram. Ophthalmologica 1971;162:1Y10), which shows the characteristics of type IV (relative hypermetropia along the vertical meridian and relative myopia along the horizontal meridian) out to an angle of between 40 and 50 degrees before behaving like type I (both meridians show relative hypermetropia). We classified this pattern as type IV/I. Seven of 13 emmetropes had this pattern. As a group, there was no significant variation of the oblique component of astigmatism with angle, but about one-half of the eyes showed significant positive slopes (more positive or less negative values in the nasal field than in the temporal field) and one-fourth showed significant negative slopes. Conclusions It is often considered that a pattern of relative peripheral hypermetropia predisposes to the development of myopia. In this context, the finding of a considerable portion of emmetropes with the IV/I pattern suggests that it is unlikely that refraction at visual field angles beyond 40 degrees from fixation contributes to myopia development.
Resumo:
This paper describes the development of an analytical model used to simulate the fatigue behaviour of roof cladding during the passage of a tropical cyclone. The model incorporated into a computer program uses wind pressure data from wind tunnel tests in combination with time history information on wind speed and direction during a tropical cyclone, and experimental fatigue characteristics data of roof claddings. The wind pressure data is analysed using a rainflow form of analysis, and a fatigue damage index calculated using a modified form of Miner's rule. Some of the results obtained to date and their significance in relation to the review of current fatigue tests are presented. The model appears to be reasonable for comparative estimation of fatigue life, but an improvement of Miner's rule is required for the prediction of actual fatigue life.
Resumo:
Currently two different fatigue tests are being used to investigate the fatigue susceptibility of roof claddings in the cyclone prone areas of Australia. In order to resolve this issue a detailed investigation was conducted to study the nature of cyclonic wind forces using wind tunnel testing and computer modelling and the fatigue behaviour of metal roof claddings using structural testing. This led to the development of an accurate, but complicated loading matrix for a design cyclone. Based on this matrix, a simplified low-high-low loading sequence has been developed for the testing of roofing systems in cyclone prone areas. This paper first reviews the currently used fatigue loading sequences, then presents details of the cyclonic wind loading matrix and finally the development of the new simplified loading sequence. This simplified sequence should become the only suitable test for most of the cyclone prone areas of Australia covered by Region C which suffers from Category 4 cyclones. For Region D which suffers from Category 5 cyclones, the same loading sequence with 20% increased cycles has been recommended. An experimental programme to validate the new simplified loading sequence has been proposed.
Resumo:
The study aimed to examine shiftworkers fatigue and the longitudinal relationships that impact on fatigue such as team climate, work life conflict, control of shifts and shift type in shift working nurses. We used a quantitative survey methodology and analysed data with a moderated hierarchical multiple regression. After matching across two time periods 18 months apart, the sample consisted of 166 nurses from one Australian hospital. Of these nurses, 61 worked two rotating day shifts (morning & afternoon/evening) and 105 were rotating shiftworkers who worked three shifts (morning afternoon/evening and nights). The findings suggest that control over shift scheduling can have significant effects on fatigue for both two-shift and three-shift workers. A significant negative relationship between positive team climate and fatigue was moderated by shift type. At both Time 1 and Time 2, work life conflict was the strongest predictor of concurrent fatigue, but over time it was not.
Resumo:
Purpose To design and manufacture lenses to correct peripheral refraction along the horizontal meridian and to determine whether these resulted in noticeable improvements in visual performance. Method Subjective refraction of a low myope was determined on the basis of best peripheral detection acuity along the horizontal visual field out to ±30° for both horizontal and vertical gratings. Subjective refraction was compared to objective refractions using a COAS-HD aberrometer. Special lenses were made to correct peripheral refraction, based on designs optimized with and without smoothing across a 3 mm diameter square aperture. Grating detection was retested with these lenses. Contrast thresholds of 1.25’ spots were determined across the field for the conditions of best correction, on-axis correction, and the special lenses. Results The participant had high relative peripheral hyperopia, particularly in the temporal visual field (maximum 2.9 D). There were differences > 0.5D between subjective and objective refractions at a few field angles. On-axis correction reduced peripheral detection acuity and increased peripheral contrast threshold in the peripheral visual field, relative to the best correction, by up to 0.4 and 0.5 log units, respectively. The special lenses restored most of the peripheral vision, although not all at angles to ±10°, and with the lens optimized with aperture-smoothing possibly giving better vision than the lens optimized without aperture-smoothing at some angles. Conclusion It is possible to design and manufacture lenses to give near optimum peripheral visual performance to at least ±30° along one visual field meridian. The benefit of such lenses is likely to be manifest only if a subject has a considerable relative peripheral refraction, for example of the order of 2 D.