351 resultados para PbO2 anode


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Highly transparent and stoichiometric boron nitride (BN) films were deposited on both electrodes (anode and cathode) of a radio-frequency parallel-plate plasma reactor by the glow discharge decomposition of two gas mixtures: B2H6-H2-NH3 and B2H6-N2. The chemical, optical, and structural properties of the films, as well as their stability under long exposition to humid atmosphere, were analyzed by x-ray photoelectron, infrared, and Raman spectroscopies; scanning and transmission electron microscopies; and optical transmittance spectrophotometry. It was found that the BN films grown on the anode using the B2H6-H2-NH3 mixture were smooth, dense, adhered well to substrates, and had a textured hexagonal structure with the basal planes perpendicular to the film surface. These films were chemically stable to moisture, even after an exposition period of two years. In contrast, the films grown on the anode from the B2H6-N2 mixture showed tensile stress failure and were very unstable in the presence of moisture. However, the films grown on the cathode from B2H6-H2-NH3 gases suffered from compressive stress failure on exposure to air; whereas with B2H6-N2 gases, adherent and stable cathodic BN films were obtained with the same crystallographic texture as anodic films prepared from the B2H6-H2-NH3 mixture. These results are discussed in terms of the origin of film stress, the effects of ion bombardment on the growing films, and the surface chemical effects of hydrogen atoms present in the gas discharge.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Le glucose est le principal substrat énergétique cérébral. Sa concentration dans le cerveau est étroitement liée à la glycémie. Chez le patient neurolésé, du fait de l'augmentation des besoins énergétiques, les réserves cérébrales de glucose sont limitées. Une glycémie suffisamment élevée paraît nécessaire pour assurer un apport adéquat de glucose au cerveau. Objectifs : Le but de cette étude est de mieux comprendre la relation entre glucose cérébral et glycémie lors de lésion cérébrale en analysant la physiologie cérébrale chez des patients neurolésés. Plus précisément nous investiguerons: La relation entre le glucose cérébral et le glucose systémique et son association avec le pronostic vital, l'association entre la neuroglucopénie et différents paramètres cérébraux tel que l'hypertension intracrânienne (HTIC) ou la dysfonction énergétique et finalement l'effet d'une perfusion de glucose 10% sur le glucose cérébral lors d'état de neuroglucopénie. Méthodologie : Analyse d'une base de données prospective comportant des patients souffrant d'un traumatisme crânio-cérébral (TCC) ou une hémorragie sous- arachnoïdienne (HSA) sévères. Les patients comateux sont monitorés par un dispositif intra-parenchymateux avancé, comprenant un cathéter de microdialyse cérébrale et un capteur de PbO2. Résultats : 34 patients consécutifs (moyenne d'âge 42 ans, moyenne de temps jusqu'au début du monitoring : 1.5 jours ± 1 ; moyenne de la durée maximale du monitoring : 6 jours ± 3) ont été étudiés, 25 patients souffrant d'un TCC et 9 patients avec une HSA. Nous avons obtenu une corrélation individuelle entre le glucose cérébral et la glycémie chez 52.9 % des patients. Lorsque la glycémie est inférieure à 5 mmol/l, on observe plus fréquemment des épisodes de neuroglucopénie en comparaison aux valeurs intermédiaires de glycémie (5 - 9.9 mmol/l). Les épisodes d'HTIC (pression intracrânienne (PIC) > 20 mmHg) sont plus fréquemment associés à des épisodes de neuroglucopénie que lorsque la pression intracrânienne est normale 75 % vs. 35%. La dysfonction énergétique est plus souvent associés à des épisodes de neuroglucopénie que lorsque le LPR est normal: 55% contre 36%. Un coefficient de corrélation entre glucose cérébral et glycémie significativement plus élevé a été obtenu chez les survivants que chez les non-survivants (0.1 [interquartile range 0.02- 0.3] contre 0.32 [0.17-0.61]). Chez les patients neuroglucopéniques ayant une corrélation entre glucose cérébral et glycémie, la perfusion de glucose i.v. fait monter le glucose cérébral jusqu'à l'arrêt de la perfusion. Conclusion : Malgré une étroite relation entre glycémie et glucose cérébral en conditions stables, cette relation peut être altérée par des causes cérébrales chez les patients neurolésés montrant que la diminution de la disponibilité du glucose extracellulaire ne résulte pas uniquement d'une hypoglycémie relative mais également de causes cérébrales tel que l'hypoperfusion, l'HTIC ou la dysfonction énergétique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In mammography, the image contrast and dose delivered to the patient are determined by the x-ray spectrum and the scatter to primary ratio S/P. Thus the quality of the mammographic procedure is highly dependent on the choice of anode and filter material and on the method used to reduce the amount of scattered radiation reaching the detector. Synchrotron radiation is a useful tool to study the effect of beam energy on the optimization of the mammographic process because it delivers a high flux of monochromatic photons. Moreover, because the beam is naturally flat collimated in one direction, a slot can be used instead of a grid for scatter reduction. We have measured the ratio S/P and the transmission factors for grids and slots for monoenergetic synchrotron radiation. In this way the effect of beam energy and scatter rejection method were separated, and their respective importance for image quality and dose analyzed. Our results show that conventional mammographic spectra are not far from optimum and that the use of a slot instead of a grid has an important effect on the optimization of the mammographic process. We propose a simple numerical model to quantify this effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recently a fingering morphology, resembling the hydrodynamic Saffman-Taylor instability, was identified in the quasi-two-dimensional electrodeposition of copper. We present here measurements of the dispersion relation of the growing front. The instability is accompanied by gravity-driven convection rolls at the electrodes, which are examined using particle image velocimetry. While at the anode the theory presented by Chazalviel et al. [J. Electroanal. Chem. 407, 61 (1996)] describes the convection roll, the flow field at the cathode is more complicated because of the growing deposit. In particular, the analysis of the orientation of the velocity vectors reveals some lag of the development of the convection roll compared to the finger envelope.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Following is the Operations Manual for the Pennsylvania Ave Bridge over I-235 located in Des Moines, Iowa, which was installed from July 1992 to October 1992. The project uses ELGARD™ 210 Anode Mesh and is divided into 3 zones. Periodic data collection and/or inspection of the cathodic protection system is required to insure proper operation and a long life. This Operation Manual contains a schedule, operation procedures, operation log forms, a rectifier panel drawing, and pertinent reference matenal. Operation procedures and operating records are contained in the body of the manual, while blank operation forms, as built drawings, and pertinent reference material are contained in the appendices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bridge deck deterioration due to corrosive effect of deicers on reinforcing steel is a major problem facing many agencies. Cathodic protection is one method used to prevent reinforcing steel corrosion. The application of a direct current to the embedded reinforcing steel and a sacrificial anode protects the steel from corrosion. This 1992 project involved placing an Elgard Titanium Anode Mesh Cathodic Protection System on a bridge deck. The anode was fastened to the deck after the Class A repair-work and the overlay was placed using the Iowa Low Slump Dense Concrete System. The system was set up initially at 1 mA/sq ft.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bridge deck and substructure deterioration due to the corrosive effects of deicing chemicals on reinforcing steel is a problem facing many transportation agencies. The main concern is protection of older bridges with uncoated reinforcing steel. Many different methods have been tried over the past years to repair bridge decks. The Iowa system of bridge deck rehabilitation has proven to be very effective. It consists of scarifying the deck surface, removing any deteriorated concrete, and overlaying with low slump dense concrete. Another rehabilitation method that has emerged is cathodic protection. It has been used for many years in the protection of underground pipelines and in 1973 was first installed on a bridge deck. Cathodic protection works by applying an external source of direct current to the embedded reinforcing steel, thereby changing the electrochemical process of corrosion. The corroding steel, which is anodic, is protected by changing it to a cathodic state. The technology involved in cathodic protection as applied to bridge decks has improved over the last 12 years. One company marketing new technology in cathodic protection systems is Raychem Corporation of Menlo Park, California. Their system utilizes a Ferex anode mesh that distributes the impressed direct current over the deck surface. Ferex mesh was selected because it seemed readily adaptable to the Iowa system of bridge deck rehabilitation. The bridge deck would be scarified, deteriorated concrete removed, Ferex anode mesh installed, and overlaid with low slump dense concrete. The Federal Highway Administration (FHWA) promotes cathodic protection under Demonstration Project No. 34, "Cathodic Protection for Reinforced Concrete Bridge Decks."

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työn tavoitteena oli tutkia eri mittausmenetelmillä metallipinnoitettujen elektrodien kulumista kulumiskokeiden aikana. Mittausmenetelminä olivat käytössä syklinen voltammetria, polarisaatiokäyrän määritys ja sähkökemiallinen impedanssispektrometria, jotka olivat offline-mittausmenetelmiä. Näiden menetelmien avulla pystyttiin seuraamaan yksittäisten elektrodien kulumista ajon aikana. Elektrodin pinnoitteen alkuaineiden pitoisuuksia tutkittiin myös elektronimikroskoopin röntgenspektrometrin avulla. Työn aikana tehdyissä kulumiskokeista havaittiin elektrodin kuluvan sitä nopeammin mitä suurempi on virrantiheys. Työssä tehtyjen elektronimikroskooppikokeiden avulla havaittiin, että harvinaisten metallien seostaminen pinnoitteeseen pidentää metallipinnoitetun elektrodin käyttöikää. Syklisen voltammetrian avulla pystyttiin seuraamaan elektrodin pinta-alan muuttumista ajon aikana. Työssä käytettyjen kulumiskokeiden avulla ei suoranaisesti pystytty määrittämään elektrodin jäljellä olevaa elinikää.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

GdBaCo2O5+x (GBCO) was evaluated as a cathode for intermediate-temperature solid oxide fuel cells. A porous layer of GBCO was deposited on an anode-supported fuel cell consisting of a 15m thick electrolyte of yttria-stabilized zirconia (YSZ) prepared by dense screen-printing anda Ni–YSZ cermet as an anode (Ni–YSZ/YSZ/GBCO). Values of power density of 150 mW cm−2 at 700◦C and ca. 250 mW cm−2 at 800◦C are reported for this standard configuration using 5% of H2 in nitrogen as fuel. An intermediate porous layer of YSZ was introduced between the electrolyte and the cathode improving the performance of the cell. Values for power density of 300 mW cm−2 at 700◦C and ca. 500 mW cm−2 at 800◦C in this configuration were achieved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Tinnitus is an often disabling condition for which there is no effective therapy. Current research suggests that tinnitus may develop due to maladaptive plastic changes and altered activity in the auditory and prefrontal cortex. Transcranial direct current stimulation (tDCS) modulates brain activity and has been shown to transiently suppress tinnitus in trials. OBJECTIVE: To investigate the efficacy and safety of tDCS in the treatment of chronic subjective tinnitus. METHODS: In a randomized, parallel, double-blind, sham-controlled study, the efficacy and safety of cathodal tDCS to the auditory cortex with anode over the prefrontal cortex was investigated in five sessions over five consecutive days. Tinnitus was assessed after the last session on day 5, and at follow-up visits 1 and 3 months post stimulation using the Tinnitus Handicap Inventory (THI, primary outcome measure), Subjective Tinnitus Severity Scale, Hospital Anxiety and Depression scale, Visual Analogue Scale, and Clinical Global Impression scale. RESULTS: 42 patients were investigated, 21 received tDCS and 21 sham stimulation. There were no beneficial effects of tDCS on tinnitus as assessed by primary and secondary outcome measures. Effect size assessed with Cohen's d amounted to 0.08 (95% CI: -0.52 to 0.69) at 1 month and 0.18 (95% CI: -0.43 to 0.78) at 3 months for the THI. CONCLUSION: tDCS of the auditory and prefrontal cortices is safe, but does not improve tinnitus. Different tDCS protocols might be beneficial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes an experiment to be performed in both instrumental analysis and experimental physical-chemistry curricular disciplines in order to open options to develop challenging basic research activities. Thus the experimental procedures and the results obtained in the preparation of electrodeposited lead dioxide onto graphite and its evaluation as potentiometric sensor for H3O+ and Pb2+ ions, are presented. The data obtained in acid-base titrations were compared with those of the traditional combination glass electrode at the same conditions. Although a linear sub-Nernstian response to free hydrogen ions was observed for the electrodeposited PbO2 electrode, a good agreement was obtained between them. Working as lead(II) sensing electrode, the PbO2 showed a linear sub-Nernstian behavior at total Pb2+ concentrations ranging from 3,5 x 10-4 to 3,0 x 10-2 mol/L in nitrate media. For the redox couple PbO2/Pb(II) the operational slope converges to the theoretical one, as the acidity of the working solution increases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The e phase of electrolytic manganese dioxide (EMD) is the structural form most easily converted in the LiMn2O4 spinel used as cathode in lithium batteries. Thus, employing titanium as anode, a study of electrolysis parameters was carried out in order to determine the best conditions to produce an e-EMD suitable for that spinel preparation. The influence of solution temperature (65oC and 90oC) and current density (between 1 mA/cm2 and 17.5 mA/cm2) on the anode potential and the EMD properties was investigated using an aqueous 2.0 mol/L MnSO4 + 0.30 mol/L H2SO4 solution. In any of the electrolysis conditions tested only the e-EMD structure was obtained, but its specific surface area varied with the applied current density and temperature. Drying the e-EMD at temperatures between 60oC and 120oC did not cause any phase changes. To produce a suitable EMD at the highest current density possible without passivation of the titanium anode, the best electrolysis parameters were determined to be 90oC and 15 mA/cm2. The e-EMD thus obtained had a specific surface area (BET) of ca. 65 m2/g.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An on-line electrodissolution procedure implemented in a flow injection system for determination of copper, zinc and lead in brasses alloys by ICP-AES is described. Sample dissolution procedure was carried out by using a PTFE chamber and a DC power supply with constant current. Solid sample was attached to chamber as anode and a gold tubing coupled in the chamber was used as cathode. An electrolytic solution flowing through the gold tubing closed the electric circuit with sample, in order to provide condition for electric dissolution when the DC power supply was switched on. The best results were achieved by using a 1.5 mol l-1 nitric acid solution as electrolyte and a 2.5 A current intensity. The procedure presented a good performance characterized by a relative standard deviation better than < 5% (n=5) and a sample throughput of 180 determinations per hour for Cu, Zn and Pb. Results were in agreement with those obtained by conventional acid dissolution (99% confidence level).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anodic electrodissolution procedure in a flow injection system for determination of constituents in alloys is discussed. This approach implement sample preparation procedure by using a chamber and a DC power supply with constant direct current. Solid sample was attached to chamber as anode. In this review a general overview of these procedure is presented. The procedure presented a good performance characterized by a high sample throughput determinations, good accuracy and relative standard deviation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Organic compounds responsible for the color of wastewaters are usually refractory to biological digestion. In this paper the photo-assisted electrolysis process is used for color removal from three of the most colored wastewaters, which are daily generated in large amounts: the E1 bleach Kraft mill effluent, a textile reactive dye effluent and a landfill leachate. Electrolysis was carried out at 26,5 mA cm-2 in a flow reactor in which the anode surface was illuminated by a 400 W high pressure Hg bulb. In all experiments 70-75% of color reduction was observed which was also followed by a net organic load oxidation.