944 resultados para Particle size, Pennisetum glaucum (L.) R. B.
Resumo:
The partial oxalate method, with the columbite route, associated with the Pechini method, was used to obtain a very fine ceramic powder at low temperature. Using this route it was possible to obtain a very reactive powder and to synthesize a lead magnesium niobate (PMN) powder with up to 100% of perovskite phase at a lower temperatures than the PbO melting point. The influence of the BaTiO3 and PbTiO3 seeds in the phase formation, along with time and temperature during the PMN calcination, was also investigated. The amount of 2% of BaTiO3 seeds promoted PMN powder formation with 100% of perovskite phase and a very narrow particle size distribution. (C) 2001 Elsevier B.V. Ltd and Techna S.r.l. All rights reserved.
Resumo:
O objetivo deste trabalho foi realizar a caracterização físico-química do pó e da tintura, e análise por espectrofotometria e cromatografia do extrato seco de Peperomia pellucida L. (H. B. K.). As metodologias seguiram a Farmacopéia Brasileira IV ed., com exceção da prospecção química, da espectrofotometria, da obtenção do perfil cromatogrfico do extrato seco, e determinação do resíduo seco. A prospecção química revelou a presença de saponinas espumídicas; açúcares redutores; proteínas e aminoácidos; fenóis; taninos; flavonóides; esterides e triterpenóides. Na análise por CCD, o melhor perfil da fração flavonoídica foi obtido com MeOH/CHOOH (90:10). Foi confirmada, através de CLAE, a presença de 3’,4’,7-tri-O-metoxiflavona no extrato seco deste material vegetal. Os resultados obtidos contribuem para a determinação de especificações de uma futura monografia em Farmacopéias da Peperomia pellucida L. (H.B.K.).
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnolgico (CNPq)
Resumo:
Silver/alanine nanocomposites with varying mass percentage of silver have been produced. The size of the silver nanoparticles seems to drive the formation of the nanocomposite, yielding a homogeneous dispersion of the silver nanoparticles in the alanine matrix or flocs of silver nanoparticles segregated from the alanine crystals. The alanine crystalline orientation is modified according to the particle size of the silver nanoparticles. Concerning a mass percentage of silver below 0.1%, the nanocomposites are homogeneous, and there is no particle aggregation. As the mass percentage of silver is increased, the system becomes unstable, and there is particle flocculation with subsequent segregation of the alanine crystals. The nanocomposites have been analyzed by transmission electron microscopy (TEM), UV-Vis absorption spectroscopy, X-ray diffraction (XRD), and Fourier transform infrared (FTIR) spectroscopy and they have been tested as radiation detectors by means of electron spin resonance (ESR) spectroscopy in order to detect the paramagnetic centers created by the radiation. In fact, the sensitivity of the radiation detectors is optimized in the case of systems containing small particles (30 nm) that are well dispersed in the alanine matrix. As the agglomeration increases, particle growth (up to 1.5 mu m) and segregation diminish the sensitivity. In conclusion, nanostructured materials can be used for optimization of alanine sensitivity, by taking into account the influence of the particles size of the silver nanoparticles on the detection properties of the alanine radiation detectors, thus contributing to the construction of small-sized detectors.
Resumo:
The goal of this study was to test the hypothesis that the aggregated state of natural marine particles constrains the sensitivity of optical beam attenuation to particle size. An instrumented bottom tripod was deployed at the 12-m node of the Martha's Vineyard Coastal Observatory to monitor particle size distributions, particle size-versus-settling-velocity relationships, and the beam attenuation coefficient (c(p)) in the bottom boundary layer in September 2007. An automated in situ filtration system on the tripod collected 24 direct estimates of suspended particulate mass (SPM) during each of five deployments. On a sampling interval of 5 min, data from a Sequoia Scientific LISST 100x Type B were merged with data from a digital floc camera to generate suspended particle volume size distributions spanning diameters from approximately 2 mu m to 4 cm. Diameter-dependent densities were calculated from size-versus-settling-velocity data, allowing conversion of the volume size distributions to mass distributions, which were used to estimate SPM every 5 min. Estimated SPM and measured c(p) from the LISST 100x were linearly correlated throughout the experiment, despite wide variations in particle size. The slope of the line, which is the ratio of c(p) to SPM, was 0.22 g m(-2). Individual estimates of c(p):SPM were between 0.2 and 0.4 g m(-2) for volumetric median particle diameters ranging from 10 to 150 mu m. The wide range of values in c(p):SPM in the literature likely results from three factors capable of producing factor-of-two variability in the ratio: particle size, particle composition, and the finite acceptance angle of commercial beam-transmissometers.
Resumo:
A Laser In-Situ Scattering Transmissometer (LISST) was used to collect vertical distribution data of particles from 2.5 to 500 µm in size. The LISST uses a multi-ring detector to measure scattering light of particles from a laser diode. Particles are classified into 32 log-spaced bins and the concentration of each bin is calculated as micro-liters per liter (µl/l). The instrument is rated to a depth of 300 m, and also records temperature and pressure. The sample interval was set to record every second. The LISST was attached to the LOPC frame to conduct casts and allow for particle-size comparisons between the two instruments. The LOPC is rated to a depth of 2000 m, thus a short deployment to a depth of 300 m was first conducted with both instruments. The instruments were then returned to the deck and the LISST removed via a quick release bracket so deep LOPC casts could be continued at a station. Raw LISST size-spectrum data is presented as concentrations for each of the 32 size bins for every second of the cast.
Resumo:
Influencia de cereal principal y el tamaño medio de partícula de la dieta sobre el desempeño productivo y calidad de los huevos de las gallinas marrones para puesta.
Resumo:
This study centers on the question: How sensitive are 231Pa/230Th and 10Be/230Th to sediment composition and redistribution? The natural radionuclides 231Pa, 230Th and 10Be recorded in deep sea sediments are tracers for water mass advection and particle fluxes. We investigate the influence of oceanic particle composition on the element adsorption in order to improve our understanding of sedimentary isotope records. We present new data on particle size specific 231Pa and 10Be concentrations. An additional separation step, based on settling velocities, led to the isolation of a very opal-rich phase. We find that opal-rich particles contain the highest 231Pa and 10Be concentrations, and higher 231Pa/230Th and 10Be/230Th isotope ratios than opal-poor particles. The fractionation relative to 230Th induced by the adsorption to opal-rich particles is more pronounced for 231Pa than for 10Be. We conclude that bulk 231Pa/230Th in Southern Ocean sediments is most suitable as a proxy for past opal fluxes. The comparison between two neighboring cores with rapid and slow accumulation rates reveals that these isotope ratios are not influenced significantly by the intensity of sediment focusing at these two study sites. However, a simulation shows that particle sorting by selective removal of sediment (winnowing) could change the isotope ratios. Consequently, 231Pa/230Th should not be used as paleocirculation proxy in cases where a strong loss of opal-rich material due to bottom currents occurred.
Resumo:
Includes bibliographical references.
Resumo:
Mode of access: Internet.
Resumo:
The present bibliography has been combined with 2 previously published bibliographies (1949 and 1954)