823 resultados para Pain management in animals
Resumo:
This book chapter represents a synthesis of the work which started in my PhD and which has been the conceptual basis for all of my research since 1993. The chapter presents a method for scientists and managers to use for selecting the type of remotely sensed data to use to meet their information needs associated with a mapping, monitoring or modelling application. The work draws on results from several of my ARC projects, CRC Rainforest and Coastal projects and theses of P.Scarth , K.Joyce and C.Roelfsema.
Resumo:
The aim of this study was to compare the intra-and inter-rater reliability of pressure pain threshold (PPT) and manual palpation (MP) of orofacial structures in symptomatic and symptom-free children for temporomandibular disorders (TMD). Fourteen children reporting pain in masticatory muscles or the temporomandibular joint and 16 symptom-free children were randomly assessed on three different occasions: by rater-1 in the first and third session and by rater-2 in the second session. The trained raters applied algometry and MP as recommended by the Research Diagnostic Criteria for TMD. Intraclass correlation coefficients and the Kappa statistic were used to assess the levels of reliability of PPT and MP, respectively. Excellent intra-and inter-rater reliability levels were observed for PPT values at most of the examined sites for symptom-free children and excellent and moderate reliability levels for children reporting pain. For MP, moderate and poor intra-rater and inter-rater reliability levels were observed for most sites in both groups. Algometry showed higher reliability levels for both groups of children and is recommended for pain assessment in children in association with MP. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Numerous studies have shown that it is possible to manipulate follicular and luteal dynamics, thereby eliminating the need for oestrus detection in embryo transfer (ET) programmes. Fixed-time ET (FTET) protocols are based on the use of gonadotrophin-releasing hormone (GnRH) and prostaglandin (PG) F or progesterone/progestogen (P4)-releasing devices and oestradiol. The FTET protocols increases the proportion of recipients transferred, and therefore pregnancy rates, compared with the use of PGF followed by ET 7 days after oestrus. Furthermore, the addition of equine chorionic gonadotrophin (eCG) to the P4 and oestradiol-based FTET protocols results in an even higher proportion of recipients transferred, and thus higher pregnancy rates. The beneficial effect of eCG treatment may be related to increased growth of the dominant follicle and increased plasma P4 concentrations during the subsequent luteal phase. In Bos taurus x Bos indicus recipients, pregnancy rates were positively correlated with the diameter of the corpus luteum (CL) and the number of CL at ET. When repeat-breeder Holstein cows were used as recipients, FTET protocols increased number of recipients transferred and pregnancy rates compared with the traditional PGF-based synchronisation protocols. In conclusion, the use of FTET protocols eliminates the need for the detection of oestrus and results in a greater proportion of recipients transferred and satisfactory pregnancy rates. Thus, FTET optimises the use of recipients, reducing labour and animal handling and facilitating the use of ET.