930 resultados para PV power profile
Resumo:
With the continued development of renewable energy generation technologies and increasing pressure to combat the global effects of greenhouse warming, plug-in hybrid electric vehicles (PHEVs) have received worldwide attention, finding applications in North America and Europe. When a large number of PHEVs are introduced into a power system, there will be extensive impacts on power system planning and operation, as well as on electricity market development. It is therefore necessary to properly control PHEV charging and discharging behaviors. Given this background, a new unit commitment model and its solution method that takes into account the optimal PHEV charging and discharging controls is presented in this paper. A 10-unit and 24-hour unit commitment (UC) problem is employed to demonstrate the feasibility and efficiency of the developed method, and the impacts of the wide applications of PHEVs on the operating costs and the emission of the power system are studied. Case studies are also carried out to investigate the impacts of different PHEV penetration levels and different PHEV charging modes on the results of the UC problem. A 100-unit system is employed for further analysis on the impacts of PHEVs on the UC problem in a larger system application. Simulation results demonstrate that the employment of optimized PHEV charging and discharging modes is very helpful for smoothing the load curve profile and enhancing the ability of the power system to accommodate more PHEVs. Furthermore, an optimal Vehicle to Grid (V2G) discharging control provides economic and efficient backups and spinning reserves for the secure and economic operation of the power system
Resumo:
Australia requires decisive action on climate change and issues of sustainability. The Urban Informatics Research Lab has been funded by the Queensland State Government to conduct a three year study (2009 – 2011) exploring ways to support Queensland residents in making more sustainable consumer and lifestyle choices. We conduct user-centred design research that inform the development of real-time, mobile, locational, networked information interfaces, feedback mechanisms and persuasive and motivational approaches that in turn assist in-situ decision making and environmental awareness in everyday settings. The study aims to deliver usable and useful prototypes offering individual and collective visualisations of ecological impact and opportunities for engagement and collaboration in order to foster a participatory and sustainable culture of life in Australia. Raising people’s awareness with environmental data and educational information does not necessarily trigger sufficient motivation to change their habits towards a more environmentally friendly and sustainable lifestyle. Our research seeks to develop a better understanding how to go beyond just informing and into motivating and encouraging action and change. Drawing on participatory culture, ubiquitous computing, and real-time information, the study delivers research that leads to viable new design approaches and information interfaces which will strengthen Australia’s position to meet the targets of the Clean Energy Future strategy, and contribute to the sustainability of a low-carbon future in Australia. As part of this program of research, the Urban Informatics Research Lab has been invited to partner with GV Community Energy Pty Ltd on a project funded by the Victorian Government Sustainability Fund. This feasibility report specifically looks at the challenges and opportunities of energy monitoring in households in Victoria that include a PV solar installation. The report is structured into two parts: In Part 1, we first review a range of energy monitoring solutions, both stand-alone and internet-enabled. This section primarily focusses on the technical capacilities. However, in order to understand this information and make an informed decision, it is crucial to understand the basic principles and limitations of energy monitoring as well as the opportunities and challenges of a networked approach towards energy monitoring which are discussed in Section 2.
Resumo:
Parabolic Trough Concentrators (PTC) are the most proven solar collectors for solar thermal power plants, and are suitable for concentrating photovoltaic (CPV) applications. PV cells are sensitive to spatial uniformity of incident light and the cell operating temperature. This requires the design of CPV-PTCs to be optimised both optically and thermally. Optical modelling can be performed using Monte Carlo Ray Tracing (MCRT), with conjugate heat transfer (CHT) modelling using the computational fluid dynamics (CFD) to analyse the overall designs. This paper develops and evaluates a CHT simulation for a concentrating solar thermal PTC collector. It uses the ray tracing work by Cheng et al. (2010) and thermal performance data for LS-2 parabolic trough used in the SEGS III-VII plants from Dudley et al. (1994). This is a preliminary step to developing models to compare heat transfer performances of faceted absorbers for concentrating photovoltaic (CPV) applications. Reasonable agreement between the simulation results and the experimental data confirms the reliability of the numerical model. The model explores different physical issues as well as computational issues for this particular kind of system modeling. The physical issues include the resultant non-uniformity of the boundary heat flux profile and the temperature profile around the tube, and uneven heating of the HTF. The numerical issues include, most importantly, the design of the computational domain/s, and the solution techniques of the turbulence quantities and the near-wall physics. This simulation confirmed that optical simulation and the computational CHT simulation of the collector can be accomplished independently.
Resumo:
Gaelic Games are the indigenous sports played in Ireland, the most popular being Gaelic football and hurling. The games are contact sports and the physical demands are thought to be similar to those of Australian Rules football, rugby union, rugby league, field hockey, and lacrosse (Delahunt et al., 2011). The difference in chronological age between children in a single age group is known as relative age and its consequences as the RAE, whereby younger players are disadvantaged (Del Campo et al., 2010). The purpose of this study was to describe the physical and performance profile of sub-elite juvenile Gaelic Games players and to establish if a RAE is present in this cohort and any influence physiological moderator variables may have on this. Following receipt of ethical approval (EHSREC11-45), six sub-elite county development squads (Under-14/15/16 age groups, male, n=115) volunteered to partake in the study. Anthropometric data including skin folds and girths were collected. A number of field tests of physical performance including 5 and 20m speed, vertical and broad jump distance, and an estimate of VO2max were carried out. Descriptive data are presented as Mean SD. Juvenile sub-elite Gaelic Games players aged 14.53 0.82 y were 172.87 7.63 cm tall, had a mass of 64.74 11.06 kg, a BMI of 21.57 2.82 kg.m-2 and 9.22 4.78 % body fat. Flexibility, measured by sit and reach was 33.62 6.86 cm and lower limb power measured by vertical and broad jump were 42.19 5.73 and 191.16 25.26 cm, respectively. Participant time to complete 5m, 20m and an agility test (T-Test) was 1.12 0.07, 3.31 0.30 and 9.31 0.55 s respectively. Participant’s estimated VO2max was 48.23 5.05 ml.kg.min-1. Chi-Square analysis of birth month by quartile (Q1 = January-March) revealed that a RAE was present in this cohort, whereby an over-representation of players born in Q1 compared with Q2, Q3 and Q4 was evident (2 = 14.078, df = 3, p = 0.003). Kruskal-Wallis analysis of the data revealed no significant difference in any of the performance parameters based on quartile of birth (Alpha level = 0.05).This study provides a physical performance profile of juvenile sub-elite Gaelic Games players, comparable with those of other sports such as soccer and rugby. This novel data can inform us of the physical requirements of the sport. The evidence of a RAE is similar to that observed in other contact sports such as soccer and rugby league (Carling et al, 2009; Till et al, 2010). Although a RAE exists in this cohort, this cannot be explained by any physical/physiological moderator variables. Carling C et al. (2009). Scandinavian Journal of Medicine and Science in Sport 19, 3-9. Delahunt E et al. (2011). Journal of Athletic Training 46, 241-5. Del Campo DG et al. (2010). Journal of Sport Science and Medicine 9, 190-198. Delorme N et al. (2010). European Journal of Sport Science 10, 91-96. Till K et al. (2010). Scandinavian Journal of Medicine and Science in Sports 20, 320-329.
Resumo:
An accurate PV module electrical model is presented based on the Shockley diode equation. The simple model has a photo-current current source, a single diode junction and a series resistance, and includes temperature dependences. The method of parameter extraction and model evaluation in Matlab is demonstrated for a typical 60W solar panel. This model is used to investigate the variation of maximum power point with temperature and isolation levels. A comparison of buck versus boost maximum power point tracker (MPPT) topologies is made, and compared with a direct connection to a constant voltage (battery) load. The boost converter is shown to have a slight advantage over the buck, since it can always track the maximum power point.
Resumo:
An accurate PV module electrical model is presented based on the Shockley diode equation. The simple model has a photo-current current source, a single diode junction and a series resistance, and includes temperature dependences. The method of parameter extraction and model evaluation in Matlab is demonstrated for a typical 60W solar panel. This model is used to investigate the variation of maximumpower point with temperature and insolation levels. A comparison of buck versus boostmaximum power point tracker (MPPT) topologies is made, and compared with a direct connection to a constant voltage (battery) load. The boost converter is shown to have a slight advantage over the buck, since it can always track the maximum power point.
Resumo:
Irradiance profile around the receiver tube (RT) of a parabolic trough collector (PTC) is a key effect of optical performance that affects the overall energy performance of the collector. Thermal performance evaluation of the RT relies on the appropriate determination of the irradiance profile. This article explains a technique in which empirical equations were developed to calculate the local irradiance as a function of angular location of the RT of a standard PTC using a vigorously verified Monte Carlo ray tracing model. A large range of test conditions including daily normal insolation, spectral selective coatings and glass envelop conditions were selected from the published data by Dudley et al. [1] for the job. The R2 values of the equations are excellent that vary in between 0.9857 and 0.9999. Therefore, these equations can be used confidently to produce realistic non-uniform boundary heat flux profile around the RT at normal incidence for conjugate heat transfer analyses of the collector. Required values in the equations are daily normal insolation, and the spectral selective properties of the collector components. Since the equations are polynomial functions, data processing software can be employed to calculate the flux profile very easily and quickly. The ultimate goal of this research is to make the concentrating solar power technology cost competitive with conventional energy technology facilitating its ongoing research.
Resumo:
The reliable operation of distribution systems is critically dependent on detailed understanding of load impacts on distribution transformer insulation systems. This paper estimates the impact of rooftop photovoltaic (PV) generation on a typical 200-kVA, 22/0.415-kV distribution transformer life under different operating conditions. This transformer supplies a suburban area with a high penetration of roof top photovoltaic systems. The transformer loads and the phase distribution of the PV systems are significantly unbalanced. Oil and hot-spot temperature and remnant life of distribution transformer under different PV and balance scenarios are calculated. It is shown that PV can significantly extend the transformer life.
Resumo:
This paper presents a distributed communication based active power curtailment (APC) control scheme for grid connected photovoltaic (PV) systems to address voltage rise. A simple distribution feeder model is presented and simulated using MATLAB. The resource sharing based control scheme proposed is shown to be effective at reducing voltage rise during times of peak generation and low load. Simulations also show the even distribution of APC using simple communications. Simulations demonstrate the versatility of the proposed control method under major communication failure conditions. Further research may lead to possible applications in coordinated electric vehicle (EV) charging.
Resumo:
In this paper, load profile and operational goal are used to find optimal sizing of combined PV-energy storage for a future grid-connected residential building. As part of this approach, five operational goals are introduced and the annual cost for each operation goal has been assessed. Finally, the optimal sizing for combined PV-energy storage has been determined, using direct search method. In addition, sensitivity of the annual cost to different parameters has been analyzed.
Resumo:
This project was an innovative approach in developing smart coordination of available energy resources to improve the integration level of PV in distribution network. Voltage and loading issues are considered as the main concerns for future electricity grid which need to be avoided using such resources. A distributed control structure was proposed for the resources in distribution network to avoid noted power quality issues.
Resumo:
A typical low power IPT system employs an H-Bridge converter with a simple control strategy to generate a high frequency current from DC power supply. This paper proposes a cascaded multilevel converter for bidirectional IPT (BIPT) systems, which is suitable for low to medium power applications as well as for situations such as PV cells where several individual DC sources are to be utilized. A novel modulation strategy is proposed for the multilevel converter with the aim of minimizing switching losses. Series - Series (SS) compensation circuit is adopted for the IPT system and a mathematical model is presented to minimize the coil losses of the system under varying output power. Theoretical results presented in comparison to the simulations to demonstrate the applicability of the proposed concept and the validity of the developed model. The experimental results show the feasibility of the proposed phase shift modulation.
Resumo:
Purpose In the past, leadership scholars have tended to focus on leadership as a force for good and productivity (Ashworth, 1994; Higgs, 2009; Padilla, Hogan, & Kaiser, 2007). However, recently attention has been given to the ‘dark side’ of leadership (see Higgs, 2009; Judge, Piccolo, & Kosalka, 2009). The aim of this chapter is to explore dark leadership from the perspective of the narcissistic leader using a fictional character from a popular film. Methodology/approach Using the Diagnostic and Statistical Manual of Mental Disorders, 4th edition, 1994 (DSM-IV) (American Psychiatric Association, 2000) as an operational definition of narcissistic personality disorder we explore the psychology of the narcissistic leader through a fictional character study in a popular film. Findings We have created a psychological profile of a narcissistic leader which identifies specific behavioural characteristics within a toxic organizational culture. Social implications This study has implications for employees within any organizational culture. It is significant because it can illustrate how dark leadership can impact negatively within organizations. Originality/value The use of actual living persons on which to base case study material in the study of dark leadership is problematic and constrained by ethical issues. However, the use of characters in fiction, such as contemporary film and drama, represents an excellent source of case study material. Given that little empirical works exists on narcissistic leaders and leadership, the chapter adds originality and value to the field.
Resumo:
Integrating Photovoltaic (PV) systems with battery energy storage in the distribution network will be essential to allow for continued uptake of domestic PV system installations. With increasing concerns regarding environmental and climate change issues, incorporating sources of renewable energy into power networks across the world will be key for a sustainable future. Australia is well placed to utilise solar energy as a significant component of its future energy generation and within the last 5 years there has been a rapid growth in the penetration levels seen by the grid. This growth of PV systems is causing a number of issues including intermittency of supply, negative power flow and voltage rises. Using the simulator tool GridLAB-D with a model of a typical South-East Queensland (SEQ) 11 kV distribution feeder, the effect of various configurations of PV systems have been offset with Battery Energy Storage Systems (BESS). From this, combinations of PV and storage that are most effective at mitigating the issues were explored.
Resumo:
Integration of rooftop photovoltaics (PVs) in residential networks at moderate penetration levels is becoming a reality in many countries including Australia. Despite the technical challenges in properly accommodating PV units, one of the major benefits is the ability of PV units to extend useful life time of distribution transformers. This effect is not quantified in the existing literature. This paper carries out an analysis into the impacts of rooftop PVs at different penetration levels on the performance of distribution transformers and residential networks. This paper presents a methodology to quantify the benefit of the distribution transformer life extension brought about by customer-owned rooftop PV units. The proposed methodology is applied to a real distribution system with various scenarios, including different penetration levels. The results show the distribution transformer loss-of-life function, as a function of the rooftop PV penetration level, is monotonically decreasing function which saturates after a certain penetration level. The best life improvements occur with transformers that are highly loaded and the presence of a significant PV installation may support the deferral of transformer upgrades.