944 resultados para PRESSURE-DROP
Resumo:
The flow behaviors of CH3CCl2F hydrate slurry with volume concentration of 10-70% were studied in a new built flow loop with a diameter of 42.0 mm and length of 30.0 m. Morphologies of the fluids from slurrylike hydrates to slushlike hydrates with increasing of hydrate volume concentration in pipeline were observed. Pressure drops in pipeline also were studied and an exceptional pressure transition zone with hydrate volume concentration between 30% and 40% was found for the first time, which can be used as a notation to judge if the pipeline runs safely or not. Fanning friction factors of the hydrate slurries with all hydrate contents tend to constants between 0.38 and 0.5, which depend on the volume concentration in slurries, when the velocity reaches 1.5 m/s. A simple relation to estimate the pressure drop of hydrate slurry in pipeline was presented and verified. Experimental results were compared to the estimated results, which showed a good agreement.
Resumo:
Condensation of steam in a single microchannel, silicon test section was investigated visually at low flow rates. The microchannel was rectangular in cross-section with a depth of 30 pm, a width of 800 mu m and a length of 5.0 mm, covered with a Pyrex glass to allow for visualization of the bubble formation process. By varying the cooling rate during condensation of the saturated water vapor, it was possible to control the shape, size and frequency of the bubbles formed. At low cooling rates using only natural air convection from the ambient environment, the flow pattern in the microchannel consisted of a nearly stable elongated bubble attached upstream (near the inlet) that pinched off into a train of elliptical bubbles downstream of the elongated bubble. It was observed that these elliptical bubbles were emitted periodically from the tip of the elongated bubble at a high frequency, with smaller size than the channel width. The shape of the emitted bubbles underwent modifications shortly after their generation until finally becoming a stable vertical ellipse, maintaining its shape and size as it flowed downstream at a constant speed. These periodically emitted elliptical bubbles thus formed an ordered bubble sequence (train). At higher cooling rates using chilled water in a copper heat sink attached to the test section, the bubble formation frequency increased significantly while the bubble size decreased, all the while forming a perfect bubble train flowing downstream of the microchannel. The emitted bubbles in this case immediately formed into a circular shape without any further modification after their separation from the elongated bubble upstream. The present study suggests that a method for controlling the size and generation frequency of microbubbles could be so developed, which may be of interest for microfluidic applications. The breakup of the elongated bubble is caused by the large Weber number at the tip of the elongated bubble induced by the maximum vapor velocity at the centerline of the microchannel inside the elongated bubble and the smaller surface tension force of water at the tip of the elongated bubble.
Resumo:
Transient flow patterns and bubble slug lengths were investigated with oxygen gas (O-2) bubbles produced by catalytic chemical reactions using a high speed camera bonded with a microscope. The microreactor consists of an inlet liquid plenum, nine parallel rectangular microchannels followed by a micronozzle, using the MEMS fabrication technique. The etched surface was deposited by the thin platinum film, which is acted as the catalyst. Experiments were performed with the inlet mass concentration of the hydrogen peroxide from 50% to 90% and the pressure drop across the silicon chip from 2.5 to 20.0 kPa. The silicon chip is directly exposed in the environment thus the heat released via the catalytic chemical reactions is dissipated into the environment and the experiment was performed at the room temperature level. It is found that the two-phase flow with the catalytic chemical reactions display the cyclic behavior. A full cycle consists of a short fresh liquid refilling stage, a liquid decomposition stage followed by the bubble slug flow stage. At the beginning of the bubble slug flow stage, the liquid slug number reaches maximum, while at the end of the bubble slug flow stage the liquid slugs are quickly flushed out of the microchannels. Two or three large bubbles are observed in the inlet liquid plenum, affecting the two-phase distributions in microchannels. The bubble slug lengths, cycle periods as well as the mass flow rates are analyzed with different mass concentrations of hydrogen peroxide and pressure drops. The bubble slug length is helpful for the selection of the future microreactor length ensuring the complete hydrogen peroxide decomposition. Future studies on the temperature effect on the transient two-phase flow with chemical reactions are recommended.
Resumo:
The initiation of pipeline spanning involves the coupling between the flow over the pipeline and the seepage-flow in the soil underneath the pipeline. The pipeline spanning initiation is experimentally observed and discussed in this article. It is qualitatively indicated that the pressure-drop induced soil seepage failure is the predominant cause for pipeline spanning initiation. A flow-pipe-seepage sequential coupling Finite Element Method (FEM) model is proposed to simulate the coupling between the water flow-field and the soil seepage-field. A critical hydraulic gradient is obtained for oblique seepage failure of the sand in the direction tangent to the pipe. Parametric study is performed to investigate the effects of inflow velocity, pipe embedment on the pressure-drop, and the effects of soil internal friction angle and pipe embedment-to-diameter ratio on the critical flow velocity for pipeline spanning initiation. It is indicated that the dimensionless critical flow velocity changes approximately linearly with the soil internal friction angle for the submarine pipeline partially-embedded in a sandy seabed.
Resumo:
对新型油水分离器关键装置柱型旋流器进行了性能实验研究,得到了压降,压降比与进口流量和溢流比之间的关系.结果表明,柱型旋流器内压降随着流量的增大而增大,呈抛物线型增长;压降比与溢流比之间呈线性关系.给出了计算旋流器压降的经验关系式.这些结果对柱型旋流器的设计运行和操作控制有着重要的指导作用,目前已用于南海平台油水分离器的现场实验
Resumo:
本文所介绍的水下机械手液压控制系统为一典型的具有变回油压力封闭式系统。文中阐述了此种系统液压动力机构的设计原理及静、动态参数的分析计算方法。对于在变回油压力下,由四通阀控制的非对称油缸的静态特性进行了详细的分析。给出了在不同回油压力下,不同面积比的非对称油缸、阀的负载压降及最大空载流量的变化规律。这对于确定水下机械手的液压动力机构的参数提供了依据。
Resumo:
The practical application and development of the time-lapse seismic reservoir monitor technology has indicated which has already become one of most important development technologies in seeking the surplus oil distribution and improving the reservoir recovering. The paper, first obtained the rock physics experiment analysis data according to the Bohai Sea loose sandstone in-situ measure technical, and determined the feasibility research of the S oil-field on the time-lapse seismic reservoir monitoring combining with the time-lapse numeric simulation technology, which was used to analyze the time-lapse seismic respond raw of the reservoir parameters change and pointed out the attentive problems during the real time-lapse seismic processing and interpretation. Next, simply introduced the technical link and the effect of the time-lapse mutual constrained fidelity and match processing aiming at the local complex gathering condition, geological condition, development engineering condition. Third, introduced the time-lapse integrated interpretation and the technical system with the innovative key technology that includes the time-lapse difference explanation technology, the time-lapse seismic multi-attributes integrated interpretation technology, and the time-lapse constrained reservoir parameters inversion technology, and so on. Using the time-lapse difference direct explanation technology, directly obtained the surplus oil macroscopic distribution through the difference seismic data; Using the presenting 8 big principles of the sublayer isochronisms comparison, carried on the time-lapse integrated interpretation analysis on the fine sublayer comparison and the thin oil-layer(group) contrast and the oil layer (group); The paper putted up the research, contrast, applications of the multi-sides sensitive attribute analysis and the RBF nerve network on the nearest study algorithm, and predicted the reservoir parameters and the surplus oil distribution with them; Combining with innovative researches and the time-lapse seismic constrained reservoir parameters inversion technology realized the good combination of the seismic and the reservoir engineering. Fourth, under fully analyzing the geology condition, the reservoir condition, the exploit dynamic data, and the seismic data of the S oil-field, and analyzing the time-lapse difference factors with reservoir dynamic exploit data, calibrated the oil-gas saturation change, the pressure change, the water saturation change, and determined the rationality of the time-lapse seismic difference, and finally obtained the surplus oil distribution, the water flood characteristic understanding, reservoir degasification, and pressure drop raw, and so on, which had been used in the well pattern tightening plan proof of the S oil-field development adjustment plan. Finally, the paper summarized the knowledge and understanding of the marine time-lapse seismic integrated interpretation, also had pointed out the further need researched question.
Resumo:
Tangential flow affinity membrane cartridge (TFAMC) fs a new model of immunoadsorption therapy for hemoperfusion. Recombinant Protein A was immobilized on the membrane cartridge through Schiff base formation for extracorporeal IgG and immune complex removal from blood. Flow characteristics, immunoadsorption capacity and biocompatibility of protein A TFAMC were studied. The results showed that the pressure drop increased with the increasing flow rate of water, plasma and blood, demonstrating reliable strength of membrane at high now rare. The adsorption capacities of protein A TFAMC for IgG from human plasma and blood were measured. The cartridge with 139 mg protein A immobilized on the matrix (6 mg protein A/g dry matrix) adsorbed 553 mg IgG (23.8 mg IgG/g dry matrix) from human plasma and 499.4 mg IgG (21.5 mg IgG/g dry matrix) from human blood, respectively. The circulation time had a major influence on IgG adsorption capacity, but the flow rate had little influence. Experiments in vitro and in vivo confirmed that protein A TFAMC mainly adsorbed Ige and Little of other plasma proteins, and that blood cell damage was negligible. The extracorporeal circulation system is safe and reliable. Copyright (C) 1999 John Wiley & Sons, Ltd.
Resumo:
This study has considered the optimisation of granola breakfast cereal manufacturing processes by wet granulation and pneumatic conveying. Granola is an aggregated food product used as a breakfast cereal and in cereal bars. Processing of granola involves mixing the dry ingredients (typically oats, nuts, etc.) followed by the addition of a binder which can contain honey, water and/or oil. In this work, the design and operation of two parallel wet granulation processes to produce aggregate granola products were incorporated: a) a high shear mixing granulation process followed by drying/toasting in an oven. b) a continuous fluidised bed followed by drying/toasting in an oven. In high shear granulation the influence of process parameters on key granule aggregate quality attributes such as granule size distribution and textural properties of granola were investigated. The experimental results show that the impeller rotational speed is the single most important process parameter which influences granola physical and textural properties. After that binder addition rate and wet massing time also show significant impacts on granule properties. Increasing the impeller speed and wet massing time increases the median granule size while also presenting a positive correlation with density. The combination of high impeller speed and low binder addition rate resulted in granules with the highest levels of hardness and crispness. In the fluidised bed granulation process the effect of nozzle air pressure and binder spray rate on key aggregate quality attributes were studied. The experimental results show that a decrease in nozzle air pressure leads to larger in mean granule size. The combination of lowest nozzle air pressure and lowest binder spray rate results in granules with the highest levels of hardness and crispness. Overall, the high shear granulation process led to larger, denser, less porous and stronger (less likely to break) aggregates than the fluidised bed process. The study also examined the particle breakage of granola during pneumatic conveying produced by both the high shear granulation and the fluidised bed granulation process. Products were pneumatically conveyed in a purpose built conveying rig designed to mimic product conveying and packaging. Three different conveying rig configurations were employed; a straight pipe, a rig consisting two 45° bends and one with 90° bend. Particle breakage increases with applied pressure drop, and a 90° bend pipe results in more attrition for all conveying velocities relative to other pipe geometry. Additionally for the granules produced in the high shear granulator; those produced at the highest impeller speed, while being the largest also have the lowest levels of proportional breakage while smaller granules produced at the lowest impeller speed have the highest levels of breakage. This effect clearly shows the importance of shear history (during granule production) on breakage during subsequent processing. In terms of the fluidised bed granulation, there was no single operating parameter that was deemed to have a significant effect on breakage during subsequent conveying. Finally, a simple power law breakage model based on process input parameters was developed for both manufacturing processes. It was found suitable for predicting the breakage of granola breakfast cereal at various applied air velocities using a number of pipe configurations, taking into account shear histories.
Resumo:
This note presents a simple model for prediction of liquid hold-up in two-phase horizontal pipe flow for the stratified roll wave (St+RW) flow regime. Liquid hold-up data for horizontal two-phase pipe flow [1, 2, 3, 4, 5 and 6] exhibit a steady increase with liquid velocity and a more dramatic fall with increasing gas rate as shown by Hand et al. [7 and 8] for example. In addition the liquid hold-up is reported to show an additional variation with pipe diameter. Generally, if the initial liquid rate for the no-gas flow condition gives a liquid height below the pipe centre line, the flow patterns pass successively through the stratified (St), stratified ripple (St+R), stratified roll wave, film plus droplet (F+D) and finally the annular (A+D, A+RW, A+BTS) regimes as the gas rate is increased. Hand et al. [7 and 8] have given a detailed description of this progression in flow regime development and definitions of the patterns involved. Despite the fact that there are over one hundred models which have been developed to predict liquid hold-up, none have been shown to be universally useful, while only a handful have proven to be applicable to specific flow regimes [9, 10, 11 and 12]. One of the most intractable regimes to predict has been the stratified roll wave pattern where the liquid hold-up shows the most dramatic change with gas flow rate. It has been suggested that the momentum balance-type models, which give both hold-up and pressure drop prediction, can predict universally for all flow regimes but particularly in the case of the difficult stratified roll wave pattern. Donnelly [1] recently demonstrated that the momentum balance models experienced some difficulties in the prediction of this regime. Without going into lengthy details, these models differ in the assumed friction factor or shear stress on the surfaces within the pipe particularly at the liquid–gas interface. The Baker–Jardine model [13] when tested against the 0.0454 m i.d. data of Nguyen [2] exhibited a wide scatter for both liquid hold-up and pressure drop as shown in Fig. 1. The Andritsos–Hanratty model [14] gave better prediction of pressure drop but a wide scatter for liquid hold-up estimation (cf. Fig. 2) when tested against the 0.0935 m i.d. data of Hand [5]. The Spedding–Hand model [15], shown in Fig. 3 against the data of Hand [5], gave improved performance but was still unsatisfactory with the prediction of hold-up for stratified-type flows. The MARS model of Grolman [6] gave better prediction of hold-up (cf. Fig. 4) but deterioration in the estimation of pressure drop when tested against the data of Nguyen [2]. Thus no method is available that will accurately predict liquid hold-up across the whole range of flow patterns but particularly for the stratified plus roll wavy regime. The position is particularly unfortunate since the stratified-type regimes are perhaps the most predominant pattern found in multiphase lines.
Resumo:
Pressure drop data are reported for two phase air-water flow through a vertical to horizontal 90° elbow bend set in 0.026 m i.d. pipe. The pressure drop in the vertical inlet tangent showed some significant differences to that found for straight vertical pipe. This was caused by the elbow bend partially choking the inflow resulting in a build-up of pressure and liquid in the vertical inlet riser and differences in the structure of the flow regimes when compared to the straight vertical pipe. The horizontal outlet tangent by contrast gave data in general agreement with literature even to exhibiting a drag reduction region at low liquid rates and gas velocities between 1 and 2 m s -1. The elbow bend pressure drop was best correlated in terms of le/d determined using the actual pressure loss in the inlet vertical riser. The data showed a general increase with fluid rates that tapered off at high fluid rates and exhibited a negative pressure region at low rates. The latter was attributed to the flow being smoothly accommodated by the bend when it passed from slug flow in the riser to smooth stratified flow in the outlet tangent. A general correlation was presented for the elbow bend pressure drop in terms of total Reynolds numbers. A modified Lockhart-Martinelli model gave prediction of the data.
Resumo:
Flow maldistribution of the exhaust gas entering a Diesel Particulate Filter (DPF) can cause uneven soot distribution during loading and excessive temperature gradients during the regeneration phase. Minimising the magnitude of this maldistribution is therefore an important consideration in the design of the inlet pipe and diffuser, particularly in situations where packaging constraints dictate bends in the inlet pipe close to the filter, or a sharp diffuser angle. This paper describes the use of Particle Image Velocimetry (PIV) to validate a Computational Fluid Dynamic (CFD) model of the flow within the inlet diffuser of a DPF so that CFD can be used with confidence as a tool to minimise this flow maldistribution. PIV is used to study the flow of gas into a DPF over a range of steady state flow conditions. The distribution of flow approaching the front face of the substrate was of particular interest to this study. Optically clear diffusing cones were designed and placed between pipe and substrate to allow PIV analysis to take place. Stereoscopic PIV was used to eliminate any error produced by the optical aberrations caused by looking through the curved wall of the inlet cone. In parallel to the experiments, numerical analysis was carried out using a CFD program with an incorporated DPF model. Boundary conditions for the CFD simulations were taken from the experimental data, allowing an experimental validation of the numerical results. The CFD model incorporated a DPF model, the cement layers seen in segmented filters and the intumescent matting that is commonly used to pack the filter into a metal casing. The mesh contained approximately 580,000 cells and used the realizable ?-e turbulence model. The CFD simulation predicted both pressure drop across the DPF and the velocity field within the cone and at the DPF face with reasonable accuracy, providing confidence in the use the CFD in future work to design new, more efficient cones.
Resumo:
Thermal management as a method of heightening performance in miniaturized electronic devices using microchannel heat sinks has recently become of interest to researchers and the industry. One of the current challenges is to design heat sinks with uniform flow distribution. A number of experimental studies have been conducted to seek appropriate designs for microchannel heat sinks. However, pursuing this goal experimentally can be an expensive endeavor. The present work investigates the effect of cross-links on adiabatic two-phase flow in an array of parallel channels. It is carried out using the three dimensional mixture model from the computational fluid dynamics software, FLUENT 6.3. A straight channel and two cross-linked channel models were simulated. The cross-links were located at 1/3 and 2/3 of the channel length, and their widths were one and two times larger than the channel width. All test models had 45 parallel rectangular channels, with a hydraulic diameter of 1.59 mm. The results showed that the trend of flow distribution agrees with experimental results. A new design, with cross-links incorporated, was proposed and the results showed a significant improvement of up to 55% on flow distribution compared with the standard straight channel configuration without a penalty in the pressure drop. Further discussion about the effect of cross-links on flow distribution, flow structure, and pressure drop was also documented.