490 resultados para Orthopedic


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Musculoskeletal diseases are one of the leading causes of disability worldwide. Tendon injuries are responsible for substantial morbidity, pain and disability. Tissue engineering strategies aim at translating tendon structure into biomimetic materials. The main goal of the present study is to develop microengineered hydrogel fibers through the combination of microfabrication and chemical interactions between oppositely charged polyelectrolytes. For this, methacrylated hyaluronic acid (MeHA) and chondroitin sulfate (MeCS) were combined with chitosan (CHT). Hydrogel fibers were obtained by injecting polymer solutions (either MeHA or MeHA/MeCS and CHT) in separate microchannels that join at a y-junction, with the materials interacting upon contact at the interface. To evaluate cell behavior, human tendon derived cells (hTDCs) were isolated from tendon surplus samples during orthopedic surgeries and seeded on top of the fibers. hTDCs adhered to the surface of the fibers, remaining viable, and were found to be expressing CD44, the receptor for hyaluronic acid. The synthesis of hydrogel fibers crosslinkable through both physical and chemical mechanisms combined with microfabrication technology allows the development of biomimetic structures with parallel fibers being formed towards the replication of tendon tissue architecture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The weak fixation of biomaterials within the bone structure is one of the major reasons of implants failures. Calcium phosphate (CaP) coatings are used in bone tissue engineering to improve implant osseointegration by enhancing cellular adhesion, proliferation and differentiation, leading to a tight and stable junction between implant and host bone. It has also been observed that materials compatible with bone tissue either have a CaP coating or develop such a calcified surface upon implantation. Thus, the development of bioactive coatings becomes essential for further improvement of integration with the surrounding tissue. However, most of current applied CaP coatings methods (e.g. physical vapor deposition), cannot be applied to complex shapes and porous implants, provide poor structural control over the coating and prevent incorporation of bioactive organic compounds (e.g. antibiotics, growth factors) because of the used harsh processing conditions. Layer-by-layer (LbL) is a versatile technology that permits the building-up of multilayered polyelectrolyte films in mild conditions based on the alternate adsorption of cationic and anionic elements that can integrate bioactive compounds. As it is recognized in natureâ s biomineralization process the presence of an organic template to induce mineral deposition, this work investigate a ion based biomimetic method where all the process is based on LbL methodology made of weak natural-origin polyelectrolytes. A nanostructured multilayer component, with 5 or 10 bilayers, was produced initially using chitosan and chondroitin sulphate polyelectrolyte biopolymers, which possess similarities with the extracellular matrix and good biocompatibility. The multilayers are then rinsed with a sequential passing of solutions containing Ca2+ and PO43- ions. The formation of CaP over the polyelectrolyte multilayers was confirmed by QCM-D, SEM and EDX. The outcomes show that 10 polyelectrolyte bilayer condition behaved as a  better site for initiating the formation of CaP as the precipitation occur at earlier stages than in 5 polyelectrolyte bilayers one. This denotes that higher number of bilayers could hold the CaP crystals more efficiently. This work achieved uniform coatings that can be applied to any surface with access to the liquid media in a low-temperature method, which potentiates the manufacture of effective bioactive biomaterials with great potential in orthopedic applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[Excerpt] Bone tissue engineering is a very challenging and promising field, which handles with the limitations of bone regenerative capacity and the failure of current orthopedic implants [1]. This work describes the preparation and characterization of an injectable dextrin-based hydrogel (oDex) able to incorporate nanoparticles, cells, biomolecules or Bonelike~ granules [2]. (...)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Engenharia de Tecidos, Medicina Regenerativa e Células Estaminais.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of biomaterials to direct osteogenic differentiation of human mesenchymal stem cells (hMSCs) in the absence of osteogenic supplements is thought to be part of the next generation of orthopedic implants. We previously engineered surface-roughness gradients of average roughness (Ra) varying from the sub-micron to the micrometer range ( 0.5–4.7 lm), and mean distance between peaks (RSm) gradually varying from 214 lm to 33 lm. Here we have screened the ability of such surface-gradients of polycaprolactone to influence the expression of alkaline phosphatase (ALP), collagen type 1 (COL1) and mineralization by hMSCs cultured in dexamethasone (Dex)-deprived osteogenic induction medium (OIM) and in basal growth medium (BGM). Ra 1.53 lm/RSm 79 lm in Dex-deprived OI medium, and Ra 0.93 lm/RSm 135 lm in BGM consistently showed higher effectiveness at supporting the expression of the osteogenic markers ALP, COL1 and mineralization, compared to the tissue culture polystyrene (TCP) control in complete OIM. The superior effectiveness of specific surface-roughness revealed that this strategy may be used as a compelling alternative to soluble osteogenic inducers in orthopedic applications featuring the clinically relevant biodegradable polymer polycaprolactone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia e Gestão da Qualidade

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento (Programa doutoral em Engenharia de Materiais)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inspired by nature, in particular by the marine mussels adhesive proteins (MAPs) and by the tough brick-and-mortar nacre-like structure, novel multilayered films are prepared in the present work. Organic-inorganic multilayered films, with an architecture similar to nacre based on bioactive glass nanoparticles (BG), chitosan and hyaluronic acid modified with catechol groups, which are the main responsible for the outstanding adhesion in MAPs, are developed for the first time. The biomimetic conjugate is prepared by carbodiimide chemistry and analyzed by ultraviolet-visible spectrophotometry. The build-up of the multilayered films is monitored with a quartz crystal microbalance with dissipation monitoring and their topography is characterized by atomic force microscopy. The mechanical properties reveal that the films containing catechol groups and BG present an enhanced adhesion. Moreover, the bioactivity of the films upon immersion in a simulated body fluid solution for 7 days is evaluated by scanning electron microscopy coupled with energy dispersive X-ray spectroscopy, Fourier transform infrared spectroscopy and X-ray diffraction. It was found that the constructed films promote the formation of bone-like apatite in vitro. Such multifunctional mussel inspired LbL films, which combine enhanced adhesion and bioactivity, could be potentially used as coatings of a variety of implants for orthopedic applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Theoretical background: The construct of resilience is now used in many fields, such as in sports, corporate governance and in health care system. Against the backdrop of the unique system of rehabilitation in Germany, that empowers people to participate in a social and pro-fessional way, the concept of resilience is becoming increasingly important. Accordingly this cross-sectional study should explore the resilience of orthopedic and psychosomatic patients in more detail.Questions: Are there differences in the sample that lead to different sub-samples based on the RS-13? Are there differences between the sub-samples in terms of socio-demographic data, psychosocial problems, psychological stress, stress in the workplace and the experi-ence of stress? Do socio-demografic, employment, psycho-social and psychological varia-bles influence resilience?Method: For this investigation the data of n = 131 patients was used. The data was collected in an orthopedic clinic of rehabilitation and in a psychosomatic clinic of rehabilitation. On the basis of the results of the short Resiliencescale RS-13 the sample was split into two sub-samples of N1 = 51 patients with low resilience and N2 = 80 patients with higher resilience. The questions were examined by regarding the Brief Symptom Checklist (BSCL), the Ultra-Kurz-Screening (UKS), the Stressscale (from the DASS-Questionnaire) and the Employee Attitude Survey (BAuA). Additionally a literature research was done in databases like Psy-Content, Psyndex and Springerlink to acquire the theoretical background.Results: Within the sample, there were two sub-samples, one which included patients with low resilience while the other was characterized by high resilience. Patients with low resili-ence did not differ by considering the variables of age, sex, marital status, children, educa-tion, occupational status, industry and job stress. Patients with high resilience are older and rarer incap

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Any primary care doctor should be able to decide on the fitness to drive of a given patient. The issue of an older driver, patients addicted to alcohol or drugs, under current psychotropic drug treatment, or diabetic, is discussed in the light of legal provisions and current recommendations. This article also discusses aspects associated with neurological, cardiac and orthopedic issues.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this retrospective study was to compare the clinical and radiographic results after TKA (PFC, DePuy), performed either by computer assisted navigation (CAS, Brainlab, Johnson&Johnson) or by conventional means. Material and methods: Between May and December 2006 we reviewed 36 conventional TKA performed between 2002 and 2003 (group A) and 37 navigated TKA performed between 2005 and 2006 (group B) by the same experienced surgeon. The mean age in group A was 74 years (range 62-90) and 73 (range 58-85) in group B with a similar age distribution. The preoperative mechanical axes in group A ranged from -13° varus to +13° valgus (mean absolute deviation 6.83°, SD 3.86), in group B from -13° to +16° (mean absolute deviation 5.35, SD 4.29). Patients with a previous tibial osteotomy or revision arthroplasty were excluded from the study. Examination was done by an experienced orthopedic resident independent of the surgeon. All patients had pre- and postoperative long standing radiographs. The IKSS and the WOMAC were utilized to determine the clinical outcome. Patient's degree of satisfaction was assessed on a visual analogous scale (VAS). Results: 32 of the 37 navigated TKAs (86,5%) showed a postoperative mechanical axis within the limits of 3 degrees of valgus or varus deviation compared to only 24 (66%) of the 36 standard TKAs. This difference was significant (p = 0.045). The mean absolute deviation from neutral axis was 3.00° (range -5° to +9°, SD: 1.75) in group A in comparison to 1.54° (range -5° to +4°, SD: 1.41) in group B with a highly significant difference (p = 0.000). Furthermore, both groups showed a significant postoperative improvement of their mean IKSS-values (group A: 89 preoperative to 169 postoperative, group B 88 to 176) without a significant difference between the two groups. Neither the WOMAC nor the patient's degree of satisfaction - as assessed by VAS - showed significant differences. Operation time was significantly higher in group B (mean 119.9 min.) than in group A (mean 99.6 min., p <0.000). Conclusion: Our study showed consistent significant improvement of postoperative frontal alignment in TKA by computer assisted navigation (CAS) compared to standard methods, even in the hands of a surgeon well experienced in standard TKA implantation. However, the follow-up time of this study was not long enough to judge differences in clinical outcome. Thus, the relevance of computer navigation for clinical outcome and survival of TKA remains to be proved in long term studies to justify the longer operation time. References 1 Stulberg SD. Clin Orth Rel Res. 2003;(416):177-84. 2 Chauhan SK. JBJS Br. 2004;86(3):372-7. 3 Bäthis H, et al. Orthopäde. 2006;35(10):1056-65.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report a case of acute fracture of both sesamoids of the great toe in an athlete. The fractures healed uneventfully after non-surgical treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone-mounted robotic guidance for pedicle screw placement has been recently introduced, aiming at increasing accuracy. The aim of this prospective study was to compare this novel approach with the conventional fluoroscopy assisted freehand technique (not the two- or three-dimensional fluoroscopy-based navigation). Two groups were compared: 11 patients, constituting the robotical group, were instrumented with 64 pedicle screws; 23 other patients, constituting the fluoroscopic group, were also instrumented with 64 pedicle screws. Screw position was assessed by two independent observers on postoperative CT-scans using the Rampersaud A to D classification. No neurological complications were noted. Grade A (totally within pedicle margins) accounted for 79% of the screws in the robotically assisted and for 83% of the screws in the fluoroscopic group respectively (p = 0.8). Grade C and D screws, considered as misplacements, accounted for 4.7% of all robotically inserted screws and 7.8% of the fluoroscopically inserted screws (p = 0.71). The current study did not allow to state that robotically assisted screw placement supersedes the conventional fluoroscopy assisted technique, although the literature is more optimistic about the former.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To identify predictors of nonresponse to a self-report study of patients with orthopedic trauma hospitalized for vocational rehabilitation between November 15, 2003, and December 31, 2005. The role of biopsychosocial complexity, assessed using the INTERMED, was of particular interest. DESIGN: Cohort study. Questionnaires with quality of life, sociodemographic, and job-related questions were given to patients at hospitalization and 1 year after discharge. Sociodemographic data, biopsychosocial complexity, and presence of comorbidity were available at hospitalization (baseline) for all eligible patients. Logistic regression models were used to test a number of baseline variables as potential predictors of nonresponse to the questionnaires at each of the 2 time points. SETTING: Rehabilitation clinic. PARTICIPANTS: Patients (N=990) hospitalized for vocational rehabilitation over a period of 2 years. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURE: Nonresponse to the questionnaires was the binary dependent variable. RESULTS: Patients with high biopsychosocial complexity, foreign native language, or low educational level were less likely to respond at both time points. Younger patients were less likely to respond at 1 year. Those living in a stable partnership were less likely than singles to respond at hospitalization. Sex, psychiatric, and somatic comorbidity and alcoholism were never associated with nonresponse. CONCLUSIONS: We stress the importance of assessing biopsychosocial complexity to predict nonresponse. Furthermore, the factors we found to be predictive of nonresponse are also known to influence treatment outcome and vocational rehabilitation. Therefore, it is important to increase the response rate of the groups of concern in order to reduce selection bias in epidemiologic investigations.