774 resultados para Observers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

If the Internet could be used as a method of transmitting ultrasound images taken in the field quickly and effectively, it would bring tertiary consultation to even extremely remote centres. The aim of the study was to evaluate the maximum degree of compression of fetal ultrasound video-recordings that would not compromise signal quality. A digital fetal ultrasound videorecording of 90 s was produced, resulting in a file size of 512 MByte. The file was compressed to 2, 5 and 10 MByte. The recordings were viewed by a panel of four experienced observers who were blinded to the compression ratio used. Using a simple seven-point scoring system, the observers rated the quality of the clip on 17 items. The maximum compression ratio that was considered clinically acceptable was found to be 1:50-1:100. This produced final file sizes of 5-10 MByte, corresponding to a screen size of 320 x 240 pixels, running at 15 frames/s. This study expands the possibilities for providing tertiary perinatal services to the wider community.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To describe the associations between hand osteoarthritis (OA), pain and disability in males and females and to further validate the Australian/Canadian CA hand index (AUSCAN LK3.0). Design: Cross-sectional study of 522 subjects from 101 Tasmanian families (males N=174, females N=348). Hand OA was assessed by two observers using the Altman atlas for joint space narrowing and osteophytes at distal interphalangeal and first carpometacarpal joints as well as a score for Heberden's nodes based on hand photography. Hand pain and function were assessed by the AUSCAN LK3.0 and grip strength by dynamometry in both hands on two occasions. Results: The prevalence of hand CA was high in this sample at 44-71% (depending on site). Pain and dysfunction increased with age while grip strength decreased (all P <0.001). All three measures were markedly worse in women, even after taking the severity of arthritis into account. Hand CA explained 5.7-10% of the variation in function, grip strength and pain scores, even after adjustment for age and sex. Further adjustment suggested that the osteoarthritic associations with function and grip strength were largely mediated by pain. Severity of disease was more strongly associated with these scores than presence or absence. Lastly, the AUSCAN LK3.0 showed a comparable association to grip strength with structural damage providing further evidence of index validity. Conclusions: Hand CA at these two sites makes substantial contributions to hand function, strength and pain. The associations with function and strength measures appear mediated by pain. Gender differences in all three measures persist after adjustment for variation in age and CA severity indicating that factors apart from radiographic disease are responsible. (C) 2001 OsteoArthritis Research Society International.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We compared the quality of realtime fetal ultrasound images transmitted using ISDN and IP networks. Four experienced obstetric ultrasound specialists viewed standard recordings in a randomized trial and rated the appearance of 30 fetal anatomical landmarks, each on a seven-point scale. A total of 12 evaluations were performed for various combinations of bandwidths (128, 384 or 768 kbit/s) and networks (ISDN or IF). The intraobserver coefficient of variation was 2.9%, 5.0%, 12.7% and 14.7% for the four observers. The mean overall ratings by each of the four observers were 4.6, 4.8, 5.0 and 5.3, respectively (a rating of 4 indicated satisfactory visualization and 7 indicated as good as the original recording). Analysis of variance showed that there were no significant interobserver variations nor significant differences in the mean scores for the different types of videoconferencing machines used. The most significant variable affecting the mean score was the bandwidth used. For ISDN, the mean score was 3.7 at 128 kbit/s, which was significantly worse than the mean score of 4.9 at 384 kbit/s, which was in turn significantly worse than the mean score of 5.9 at 768 kbit/s. The mean score for transmission using IP was about 0.5 points lower than that using ISDN across all the different bandwidths, but the differences were not significant. It appears that IP transmission in a private (non-shared) network is an acceptable alternative to ISDN for fetal tele-ultrasound and one deserving further study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dugong abundances in Moreton Bay (south-east Queensland) were estimated during six bi- monthly aerial surveys throughout 1995. Sampling intensity ranged between 20 and 80% for different sampling zones within the Bay, with a mean intensity of 40.5%. Population estimates for dugongs were corrected for perception bias ( the proportion of animals visible in the transect that were missed by observers), and standardised for availability bias ( the proportion of animals that were invisible due to water turbidity) with survey and species-specific correction factors. Population estimates for dugongs in Moreton Bay ranged from 503 +/- 64 (s.e.) in July to 1019 +/- 166 in January. The highest uncorrected count was 857 dugongs in December. This is greater than previous population estimates, suggesting that either previous surveys have underestimated abundance and/or that this population may have increased through recruitment, immigration, or a combination of both. The high degree of variation in population estimates between surveys may be due to temporal differences in distribution and herding behaviour. In winter, dugongs were found in smaller herds and were dispersed over a wider area than in summer. The Eastern Banks region of the bay supported 80 - 98% of the dugong population at any one time. Within this region, there were several dugong 'hot spots' that were visited repeatedly by large herds. These 'hot spots' contained seagrass communities that were dominated by species that dugongs prefer to eat. The waters of Rous Channel, South Passage and nearby oceanic waters are also frequently inhabited by dugongs in the winter months. Dugongs in other parts of Moreton Bay were at much lower densities than on the Eastern Banks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Distance sampling using line transects has not been previously used or tested for estimating koala abundance. In July 2001, a pilot survey was conducted to compare the use of line transects with strip transects for estimating koala abundance. Both methods provided a similar estimate of density. On the basis of the results of the pilot survey, the distribution and abundance of koalas in the Pine Rivers Shire, south-east Queensland, was determined using line-transect sampling. In total, 134 lines (length 64 km) were used to sample bushland areas. Eighty-two independent koalas were sighted. Analysis of the frequency distribution of sighting distances using the software program DISTANCE enabled a global detection function to be estimated for survey sites in bushland areas across the Shire. Abundance in urban parts of the Shire was estimated from densities obtained from total counts at eight urban sites that ranged from 26 to 51 ha in size. Koala abundance in the Pine Rivers Shire was estimated at 4584 (95% confidence interval, 4040-5247). Line-transect sampling is a useful method for estimating koala abundance provided experienced koala observers are used when conducting surveys.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Birth has been observed in a number of marsupial species and, in the studies to date, the newborn have crawled up to or across to the pouch. The method of birth in the quoll, a dasyurid, differs greatly from that observed in other marsupials. Births were recorded at normal speed using hand-held digital video cameras. Birth was heralded by a release of about 1 mL of watery fluid from the urogenital sinus followed by gelatinous material contained in either one or two tubes emanating from the sinus. The newborn, still encased in their placental membranes, were in the gelatinous material within a column. To exit this column, they had to grasp a hair and wriggle about 1 cm across to the pouch. In the pouch the newborn young had to compete for a teat. Although the quolls possessed 8 teats, the number of young in the pouch immediately after birth was 17, 16, 6, 16, 13 and 11 for each of the 6 quolls filmed. While birth has been described previously in another two dasyurids, the observers did not describe birth as reported here for the quoll. Nevertheless the movement of the newborn from the sinus to the pouch is so quick that this could have previously been missed. Filming birth from beneath and from the side allowed for a greater understanding of the birth process. Further studies are required to determine whether this use of a gelatinous material is part of the birth process in all dasyurids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper traces fluctuating attitudes to Islam and its Prophet, particularly in the eighteenth and nineteenth. Western perceptions, as revealed by writers of the period, encyclopaedias, biographies and commentaries, were sometimes sympathetic, sometimes dismissive; sometimes celebrating Islam's piousness; sometimes accusing it of fraud. Sometimes Islam is seen as benign; sometimes its violence is seen as endemic. Often the cultural biases of western observers are obvious: the west is progressive and historically dominant, the east (and its cultural accoutrements) is degenerate and over-zealous. But we ought not judge religions or cultures by their worst manifestations alone. Oriental societies were never just Islamic or traditional. They comprise not only those who perpetuate oppressive practices towards women but also modernizers who seek change.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three studies support the vicarious dissonance hypothesis that individuals change their attitudes when witnessing members of important groups engage in inconsistent behavior. Study 1, in which participants observed an actor in an induced-compliance paradigm, documented that students who identified with their college supported an issue more after hearing an ingroup member make a counterattitudinal speech in favor of that issue. In Study 2, vicarious dissonance occurred even when participants did not hear a speech, and attitude change was highest when the speaker was known to disagree with the issue. Study 3 showed that speaker choice and aversive consequences moderated vicarious dissonance, and demonstrated that vicarious discomfort-the discomfort observers imagine feeling if in an actor's place-was attenuated after participants expressed their revised attitudes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In 2001, China finally joined the WTO. The accession of China was looked forward to by many WTO members and China itself. However, observers had some fears that the Chinese accession would prove to be a Trojan horse, disrupting the working of the WTO. This paper looks into the Chinese accession and its involvement in the WTO Dispute Settlement and argues that these fears seem so far to be unfounded.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Ultrassonografia Cardiovascular.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – Na avaliação diagnóstica em mamografia, o desempenho do radiologista pode estar sujeito a erros de diagnóstico. Objetivo – Descrever a importância da perceção visual na análise da mamografia, identificando os principais fatores que contribuem para a perceção visual do radiologista e que condicionam a acuidade diagnóstica. Metodologia – Estudo descritivo baseado numa revisão sistemática de literatura através da PubMed e da Science Direct. Foram incluídos 42 artigos que respeitavam, pelo menos, um dos critérios de inclusão no estudo. Para a seleção das referências foi utilizada a metodologia PRISMA, constituída por 4 fases: identificação, seleção preliminar, elegibilidade e estudos incluídos. Resultados – Na avaliação diagnóstica em mamografia, a perceção visual está intimamente relacionada com: 1) diferentes parâmetros visuais e da motilidade ocular (acuidade visual, sensibilidade ao contraste e à luminância e movimentos oculares); 2) com condições de visualização de uma imagem (iluminância da sala e luminância do monitor); e 3) fadiga ocular provocada pela observação diária consecutiva de imagens. Conclusões – A perceção visual pode ser influenciada por 3 categorias de erros observados: erros de pesquisa (lesões não são fixadas pela fóvea), erros de reconhecimento (lesões fixadas, mas não durante o tempo suficiente) e erros de decisão (lesões fixadas, mas não identificadas como suspeitas). Os estudos analisados sobre perceção visual, atenção visual e estratégia visual, bem como os estudos sobre condições de visualização não caracterizam a função visual dos observadores. Para uma avaliação correta da perceção visual em mamografia deverão ser efetuados estudos que correlacionem a função visual com a qualidade diagnóstica. ABSTRACT - Introduction – Diagnostic evaluation in mammography could be influenced by the radiologist performance that could be under diagnostic errors. Aims – To describe the importance of radiologist visual perception in mammographic diagnostic evaluation and to identify the main factors that contribute to diagnostic accuracy. Methods – In this systematic review 42 references were included based on inclusion criteria (PubMed and Science Direct). PRISMA method was used to select the references following 4 steps: identification, screening, eligibility and included references. Results – Visual perception in mammography diagnostic evaluation is related with: 1) visual parameters and ocular motility (visual acuity, contrast sensitivity and luminance and ocular movements); 2) image visualization environment (room iluminance and monitor luminance); and 3) eyestrain caused by image daily consecutive observation. Conclusions – Visual perception can be influenced by three errors categories: search errors (lesions are never looked at with high-resolution foveal vision), recognition errors (lesions are looked at, but not long enough to detect or recognize) and decision errors (lesions are looked at for long periods of time but are still missed). The reviewed studies concerning visual perception, visual attention, visual strategies and image visualization environment do not describe observer’s visual function. An accurate evaluation of visual perception in mammography must include visual function analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electricity markets are complex environments, involving numerous entities trying to obtain the best advantages and profits while limited by power-network characteristics and constraints.1 The restructuring and consequent deregulation of electricity markets introduced a new economic dimension to the power industry. Some observers have criticized the restructuring process, however, because it has failed to improve market efficiency and has complicated the assurance of reliability and fairness of operations. To study and understand this type of market, we developed the Multiagent Simulator of Competitive Electricity Markets (MASCEM) platform based on multiagent simulation. The MASCEM multiagent model includes players with strategies for bid definition, acting in forward, day-ahead, and balancing markets and considering both simple and complex bids. Our goal with MASCEM was to simulate as many market models and player types as possible. This approach makes MASCEM both a short- and mediumterm simulation as well as a tool to support long-term decisions, such as those taken by regulators. This article proposes a new methodology integrated in MASCEM for bid definition in electricity markets. This methodology uses reinforcement learning algorithms to let players perceive changes in the environment, thus helping them react to the dynamic environment and adapt their bids accordingly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Objetivos – Determinar a sensibilidade e especificidade das ponderações Difusão (DWI) e T2 Fluid-Attenuated Inversion Recovery (FLAIR) na avaliação de lesões da substância branca (SB) e verificar em que medida se complementam, por forma a criar um conjunto de boas práticas na RM cranioencefálica de rotina. Metodologia – Recorrendo-se a uma metodologia quantitativa, efetuou-se uma análise retrospetiva da qual foram selecionados 30 pacientes, 10 sem patologia e 20 com patologia (2 com EM, 7 com Leucoencefalopatia, 6 com doença microangiopática e 5 com patologia da substância branca indefinida). Obteve-se uma amostra de 60 imagens, nomeadamente: 30 imagens ponderadas em DWI e 30 em T2 FLAIR. Recorrendo ao programa Viewdex®, três observadores avaliaram um conjunto de imagens segundo sete critérios: visibilidade, deteção, homogeneidade, localização, margens e dimensões da lesão e capacidade de diagnóstico. Com os resultados obtidos recorreu-se ao cálculo de sensibilidade e especificidade pelas Curvas ROC, bem como à análise estatística, nomeadamente, Teste-T, Índice de Concordância Kappa e coeficiente de correlação de Pearson entre as variáveis em estudo. Resultados – Os resultados de sensibilidade e de especificidade obtidos para a ponderação T2 FLAIR foram superiores (0,915 e 0,038, respetivamente) aos da ponderação DWI (0,08 e 0,100, respetivamente). Não se verificaram variâncias populacionais significativas. Obteve-se uma elevada correlação linear entre as variáveis com um valor r situado entre 0,8 e 0,99. Verificou-se também uma variabilidade considerável entre os observadores. Conclusões – Dados os baixos valores de sensibilidade e especificidade obtidos para a DWI, sugere-se que esta deva ser incluída no protocolo de rotina de crânio como auxiliar no diagnóstico diferencial com outras patologias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method to control the speed or the torque of a permanent-magnet direct current motor is presented. The rotor speed and the external torque estimation are simultaneously provided by appropriate observers. The sensorless control scheme is based on current measurement and switching states of power devices. The observer’s performances are dependent on the accurate machine parameters knowledge. Sliding mode control approach was adopted for drive control, providing the suitable switching states to the chopper power devices. Despite the predictable chattering, a convenient first order switching function was considered enough to define the sliding surface and to correspond with the desired control specifications and drive performance. The experimental implementation was supported on a single dsPIC and the controller includes a logic overcurrent protection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.