1000 resultados para NP EN ISO 22000:2005
Resumo:
Knowledge of the uncertainty of measurement of testing results is important when results have to be compared with limits and specifications. In the measurement of sound insulation following standards UNE EN ISO 140-4 the uncertainty of the final magnitude is mainly associated to the average sound pressure levels L1 and L2 measured. A parameter that allows us to quantify the spatial variation of the sound pressure level is the standard deviation of the pressure levels measured at different points of the room. In this work, for a wide number of measurements following standards UNE EN ISO 140-4 we analyzed qualitatively the behaviour of the standard deviation for L1 and L2. The study of sound fields in enclosed spaces is very difficult. There are a wide variety of rooms with different sound fields depending on factors as volume, geometry and materials. In general, we observe that the L1 and L2 standard deviations contain peaks and dips independent on characteristics of the rooms at single frequencies that could correspond to critical frequencies of walls, floors and windows or even to temporal alterations of the sound field. Also, in most measurements according to UNE EN ISO 140-4 a large similitude between L1 and L2 standard deviation is found. We believe that such result points to a coupled system between source and receiving rooms, mainly at low frequencies the shape of the L1 and L2 standard deviations is comparable to the velocity level standard deviation on a wall
Resumo:
En los ensayos de aislamiento acústico según normas UNE EN ISO 140-4 y 140-5 el valor de L2 es un promedio espacio-temporal de los niveles de presión sonora medidos en diferentes posiciones de la sala receptora. La desviación estándar de estos valores se puede considerar como una medida de la uniformidad del campo sonoro en el recinto. Se analiza este parámetro en función de la frecuencia y se propone un cálculo teórico del mismo como una incertidumbre combinada de la desviación estándar derivada de modelos teóricos centrados en la geometría del recinto y la desviación estándar asociada a la vibración de la pared separadora
Resumo:
Actualmente son una práctica común los procesos de normalización de métodos de ensayo y acreditación de laboratorios, ya que permiten una evaluación de los procedimientos llevados a cabo por profesionales de un sector tecnológico y además permiten asegurar unos mínimos de calidad en los resultados finales. En el caso de los laboratorios de acústica, para conseguir y mantener la acreditación de un laboratorio es necesario participar activamente en ejercicios de intercomparación, utilizados para asegurar la calidad de los métodos empleados. El inconveniente de estos ensayos es el gran coste que suponen para los laboratorios, siendo en ocasiones inasumible por estos teniendo que renunciar a la acreditación. Este Proyecto Fin de Grado se centrará en el desarrollo de un Laboratorio Virtual implementado mediante una herramienta software que servirá para realizar ejercicios de intercomparación no presenciales, ampliando de ese modo el concepto e-comparison y abriendo las bases a que en un futuro este tipo de ejercicios no presenciales puedan llegar a sustituir a los llevados a cabo actualmente. En el informe primero se hará una pequeña introducción, donde se expondrá la evolución y la importancia de los procedimientos de calidad acústica en la sociedad actual. A continuación se comentará las normativas internacionales en las que se soportará el proyecto, la norma ISO 145-5, así como los métodos matemáticos utilizados en su implementación, los métodos estadísticos de propagación de incertidumbres especificados por la JCGM (Joint Committee for Guides in Metrology). Después, se hablará sobre la estructura del proyecto, tanto del tipo de programación utilizada en su desarrollo como la metodología de cálculo utilizada para conseguir que todas las funcionalidades requeridas en este tipo de ensayo estén correctamente implementadas. Posteriormente se llevará a cabo una validación estadística basada en la comparación de unos datos generados por el programa, procesados utilizando la simulación de Montecarlo, y unos cálculos analíticos, que permita comprobar que el programa funciona tal y como se ha previsto en la fase de estudio teórico. También se realizará una prueba del programa, similar a la que efectuaría un técnico de laboratorio, en la que se evaluará la incertidumbre de la medida calculándola mediante el método tradicional, pudiendo comparar los datos obtenidos con los que deberían obtenerse. Por último, se comentarán las conclusiones obtenidas con el desarrollo y pruebas del Laboratorio Virtual, y se propondrán nuevas líneas de investigación futuras relacionadas con el concepto e-comparison y la implementación de mejoras al Laboratorio Virtual. ABSTRACT. Nowadays it is common practise to make procedures to normalise trials methods standards and laboratory accreditations, as they allow for the evaluation of the procedures made by professionals from a particular technological sector in addition to ensuring a minimum quality in the results. In order for an acoustics laboratory to achieve and maintain the accreditation it is necessary to actively participate in the intercomparison exercises, since these are used to assure the quality of the methods used by the technicians. Unfortunately, the high cost of these trials is unaffordable for many laboratories, which then have to renounce to having the accreditation. This Final Project is focused on the development of a Virtual Laboratory implemented by a software tool that it will be used for making non-attendance intercomparison trials, widening the concept of e-comparison and opening the possibility for using this type of non-attendance trials instead of the current ones. First, as a short introduction, I show the evolution and the importance today of acoustic quality procedures. Second, I will discuss the international standards, such as ISO 145-5, as well the mathematic and statistical methods of uncertainty propagation specified by the Joint Committee for Guides in Metrology, that are used in the Project. Third, I speak about the structure of the Project, as well as the programming language structure and the methodology used to get the different features needed in this acoustic trial. Later, a statistical validation will be carried out, based on comparison of data generated by the program, processed using a Montecarlo simulation, and analytical calculations to verify that the program works as planned in the theoretical study. There will also be a test of the program, similar to one that a laboratory technician would carry out, by which the uncertainty in the measurement will be compared to a traditional calculation method so as to compare the results. Finally, the conclusions obtained with the development and testing of the Virtual Laboratory will be discussed, new research paths related to e-comparison definition and the improvements for the Laboratory will be proposed.
Resumo:
El objetivo principal de este trabajo fin de máster es la obtención de los parámetros acústicos, que especifica la norma UNE-EN ISO 3382-1, con una fuente omnidireccional y con cada uno de los canales del sistema de refuerzo sonoro (Izquierdo, Central, Derecho, Surround Izquierdo y Surround Derecho) en una sala de cine, así como la comparación de los resultados. La sala estudiada es la sala 6 de Kinepolis, que está situada en Pozuelo de Alarcón (Madrid). Es una sala de gran tamaño (8800 m3) que cuenta con 706 butacas. Tras un estudio de la situación actual en la investigación de acústica de salas, se han realizado las mediciones de la respuesta al impulso con las distintas fuentes y con dos tipos de señal: Secuencias de Máxima Longitud (Maximum Length Sequence - MLS) y barridos sinusoidales. Además, se ha creado un modelo virtual de la sala con el software EASE (Enhanced Acoustic Simulator for Engineers). Los tiempos de reverberación son bastante bajos (aproximadamente 0,6 s en frecuencias medias) y los parámetros subjetivos indican gran definición y claridad. C80 es mayor a 10 dB para casi todas las bandas de frecuencia y D50 es superior a 0,8. Con los datos obtenidos de las mediciones y la simulación se ha realizado un estudio comparativo en el que se incluye información acerca de cómo varían los parámetros acústicos en función del tipo de fuente utilizada, la fiabilidad del modelo creado o la calidad acústica de la sala. Además, presenta la posibilidad de realizar la medición de algunos de los parámetros acústicos con los altavoces del sistema de refuerzo sonoro, teniendo en cuenta las mejoras de los parámetros subjetivos con los altavoces de pantalla. ABSTRACT. The main objective of this Master's Dissertation is to measured some acoustic parameters, which are specified in UNE-EN ISO 3382-1, with an omnidirectional source and each channel sound reinforcement system (Left, Center, right, Surround Left and Surround Right) in a movie theater, and the comparison of results. The analyzed room is Kinepolis' room 6, which is placed in Pozuelo de Alarcón (Madrid). It is a large room (8800 m3) which has 706 seats. After the state of the art in room acoustics research, room's impulse responses have been measured with two types of signal: Maximum Length Sequence (MLS) and Logarithmic Frequency Sine Sweep. In addition, a virtual model of the room has been created with EASE software (Enhanced Acoustic Simulator for Engineers). Reverberation times are quite low (about 0.6 s at mid frequencies) and subjective parameters indicate high definition and clarity. C80 is greater than 10 dB for almost all frequency bands and D50 is greater than 0.8. The data obtained from both the measurements and the simulation has been analyzed in order to include a comparative study with information about the acoustic parameters variation depending on the type of acoustic source, the reliability of the model created or the acoustic quality of the room. Furthermore, it presents the possibility of measuring some acoustical parameters with sound reinforcement system, taking into account improvements in subjective parameters when you are measuring with screen channels.
Resumo:
La reconfiguración del papel del estado que comienza en la década del 70 y se agudiza en la década del 90, con la retracción de los Welfare State o estados sociales, dan origen a la retracción de las políticas de carácter universal para dar lugar al surgimiento las políticas focalizadas, La agudización en las últimas décadas de una desigualdad de oportunidades y amplia proporción de población excluida, con el agravamiento de los indicadores de sociales, implicaron la necesidad de aplicar políticas sociales particulares, administradas desde diferentes espacios sociales, la educación no quedó excluida de esta situación, debiendo las escuelas y docentes hacerse cargo de la implementación de programas y/o proyectos compensatorios, que por sus características pueden ser clasificados en función de las acciones, beneficio y/o beneficiarios a los que van dirigido, nivel educativo de aplicación, fuente de financiamiento y responsables de la ejecución de los mismos. En el presente artículo se presenta una caracterización de los mismos en la provincia de Misiones Argentina en el periodo 2005-2008. En este artículo además se reproduce la graficación y sus correspondientes reflexiones, efectuada con la técnica del pictograma por docentes que dan cuenta de cómo la década del 90 implicó cambios significativos en las condiciones de trabajo, repercutiendo tanto en el rol como en las actividades sustantivas inherentes a la profesión
Resumo:
Dissertação de Mestrado em Gestão Integrada da Qualidade, Ambiente e Segurança
Resumo:
International audience
Resumo:
Tesis (Médico Veterinario). -- Universidad de La Salle. Facultad de Ciencias Agropecuarias. Programa de Medicina Veterinaria, 2014
Resumo:
Das Ziel der vorliegenden Bachelorarbeit war es, die Anwendbarkeit der DIN EN ISO 9001 Anforderungen auf Hochschulen als Dienstleistungsunternehmen zu überprüfen. Dafür wurde das Qualitätsmanagementsystem der Hochschule Anhalt untersucht und bezüglich einer Zertifizierung kontrolliert. Zunächst erfolgte eine Recherche der theoretischen Grundlagen eines Dienstleistungsunternehmens. Hierbei wurden als erstes Begriffe und Rahmenbedingungen definiert und erklärt. Weiter wurden Dienstleistungsmerkmale einer Hochschule identifiziert. Anschließend wurde das Qualitätsmanagement an Hochschulen behandelt. Nach der grundlegenden Erläuterung verschiedener Ansätze von Qualitätsmanagementsystemen, Begriffsdefinitionen, dem Hervorheben von Zielen und positiven Effekten sowie Grundlagen und Erfolgsfaktoren, wurde speziell das Qualitätsmanagement nach DIN EN ISO 9001 betrachtet. Das Hauptaugenmerk in diesem Teil der Arbeit gilt der historischen Entwicklung und dem Darlegen der Grundsätze. Der letzte Teil beschäftigt sich mit dem Qualitätsmanagementsystem der Hochschule Anhalt und den Maßnahmen zur Erfüllung der Anforderungen der DIN EN ISO 9001. In einem abschließenden Fazit wird die Arbeit nochmal einmal kurz zusammengefasst, Verbesserungsvorschläge und ein Ausblick auf zukünftige Herausforderungen gegeben.
Resumo:
La Tesi nasce a seguito della richiesta da parte di un’Azienda Socia del Consorzio Esperienza Energia di un servizio di supporto per l’ottimizzazione del proprio Sistema di Gestione dell’Energia (SGE/EnMS) ed in particolare per l’implementazione di metodologie di budgeting più efficienti rispetto a quelle attualmente utilizzate. Questo lavoro di Tesi si è sviluppato in due parti: Nella prima parte viene descritto, a livello generale, che cosa si intende per Sistema di Gestione dell’Energia o Energy Management System e quali sono i vantaggi nell’implementazione di tale sistema in una realtà industriale. Successivamente, viene presentata la norma “UNI CEI EN ISO 50001: Sistemi di Gestione dell’Energia – Requisiti e linee guida per l’uso” attraverso una breve introduzione su quelli che sono i requisiti e gli obiettivi descritti nella norma. Nella seconda parte viene descritta l’implementazione pratica di un SGE presso un’Azienda Socia di CEE, partendo dalla raccolta sia dei dati di consumo a livello globale (LIVELLO A) che a livello di Edificio (LIVELLO B), sia dall'individuazione dei principali Energy Drivers (parametri) che veicolano i consumi. Attraverso questi dati è stato creato un Modello di calcolo per la definizione dei consumi di Riferimento (Energy Baseline); tale Baseline traccia i dati di prestazione energetica da cui si parte per andare a costruire per l’azienda i principali Indicatori Energetici (EnPI, Energy Performance Indicators). Il modello energetico così costruito è stato quindi tarato sui consumi energetici misurati al fine di fornire all'Azienda un algoritmo di stima dei propri consumi energetici futuri, sia mensili che annuali. Il processo di taratura ha dimostrato come il modello energetico dell’azienda che è stato costruito in questa Tesi sia da ritenersi uno strumento affidabile per la previsione dei consumi energetici futuri ipotizzando un certo livello di produzione industriale nel corso dell’anno oggetto di simulazione.
Resumo:
Il dibattito sulla questione ambientale, ormai in continua crescita da decenni, sta conducendo ad un incremento di interesse da parte della società in merito allo sviluppo sostenibile, il quale riguarda, in modo interconnesso, l’ambito ambientale, economico e sociale. Nascono in questa ottica le certificazioni ambientali, attestati nei quali viene certificato l’impegno di un’organizzazione per la tutela dell’ambiente. L’azienda, che su base volontaria decide di ottenere la certificazione, è obbligata a dotarsi di un Sistema di Gestione Ambientale, il quale deve essere verificato da parte di un ente accreditato. La norma ISO14001 in particolare stabilisce i criteri da rispettare per l'attuazione di un efficace Sistema di Gestione Ambientale. Il presente lavoro di tesi è stato sviluppato durante un tirocinio svolto presso un’azienda operante nel settore delle bonifiche del suolo, sottosuolo ed acque sotterranee, con sede a Bologna. Lo scopo di questo elaborato è quello di applicare i requisiti della norma UNI EN ISO14001 nell’ambito di tale attività di bonifica per il controllo degli impatti ambientali. In particolare, la prima parte del tirocinio è stata dedicata all’aggiornamento ed all’ottimizzazione del Sistema di Gestione Ambientale implementato dalla società per il calcolo degli impatti ambientali delle attività aziendali, in particolare di caratterizzazione e bonifica ambientale. Successivamente l’attenzione è stata posta ad un caso di studio attualmente gestito dalla società per valutare possibili miglioramenti, dal punto di vista ambientale, degli impatti generati dalle attività di bonifica applicate al sito. Lo strumento utilizzato per questa analisi è l’applicativo “Spreadsheets for Environmental Footprint Analysis” (SEFA), sviluppato da US EPA nel 2012.