910 resultados para Multiple reflection method


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, a novel method for power quality signal decomposition is proposed based on Independent Component Analysis (ICA). This method aims to decompose the power system signal (voltage or current) into components that can provide more specific information about the different disturbances which are occurring simultaneously during a multiple disturbance situation. The ICA is originally a multichannel technique. However, the method proposes its use to blindly separate out disturbances existing in a single measured signal (single channel). Therefore, a preprocessing step for the ICA is proposed using a filter bank. The proposed method was applied to synthetic data, simulated data, as well as actual power system signals, showing a very good performance. A comparison with the decomposition provided by the Discrete Wavelet Transform shows that the proposed method presented better decoupling for the analyzed data. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To describe a new computerized method for the analysis of lid contour based on the measurement of multiple radial midpupil lid distances. Design: Evaluation of diagnostic technology. Participants and Controls: Monocular palpebral fissure images of 35 patients with Graves' upper eyelid retraction and of 30 normal subjects. Methods: Custom software was used to measure the conventional midpupil upper lid distance (MPLD) and 12 oblique MPLDs on each 15 degrees across the temporal (105 degrees, 120 degrees, 135 degrees, 150 degrees, 165 degrees, and 180 degrees) and nasal (75 degrees, 60 degrees, 45 degrees, 30 degrees, 15 degrees, and 0 degrees) sectors of the lid fissure. Main Outcome Measures: Mean, standard deviation, 5th and 95th percentiles of the oblique MPLDs obtained for patients and controls. Temporal/nasal MPLD ratios of the same angles with respect to the midline. Results: The MPLDs increased from the vertical midline in both nasal and temporal sectors of the fissure. In the control group the differences between the mean central MPLD (90 degrees) and those up to 30 degrees in the nasal (75 degrees and 60 degrees) and temporal sectors (105 degrees and 120 degrees) were not significant. For greater eccentricities, all temporal and nasal mean MPLDs increased significantly. When the MPLDs of the same angles were compared between groups, the mean values of the Graves' patients differed from control at all angles (F = 4192; P<0.0001). The greatest temporal/nasal asymmetry occurred 60 degrees from the vertical midline. Conclusions: The measurement of radial MPLD is a simple and effective way to characterize lid contour abnormalities. In patients with Graves' upper eyelid retraction, the method demonstrated that the maximum amplitude of the lateral lid flare sign occurred at 60 degrees from the vertical midline. Financial Disclosure(s): The authors have no proprietary or commercial interest in any of the materials discussed in this article. Ophthalmology 2012; 119: 625-628 (C) 2012 by the American Academy of Ophthalmology.

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study develops an automated analysis tool by combining total internal reflection fluorescence microscopy (TIRFM), an evanescent wave microscopic imaging technique to capture time-sequential images and the corresponding image processing Matlab code to identify movements of single individual particles. The developed code will enable us to examine two dimensional hindered tangential Brownian motion of nanoparticles with a sub-pixel resolution (nanoscale). The measured mean square displacements of nanoparticles are compared with theoretical predictions to estimate particle diameters and fluid viscosity using a nonlinear regression technique. These estimated values will be confirmed by the diameters and viscosities given by manufacturers to validate this analysis tool. Nano-particles used in these experiments are yellow-green polystyrene fluorescent nanospheres (200 nm, 500 nm and 1000 nm in diameter (nominal); 505 nm excitation and 515 nm emission wavelengths). Solutions used in this experiment are de-ionized (DI) water, 10% d-glucose and 10% glycerol. Mean square displacements obtained near the surface shows significant deviation from theoretical predictions which are attributed to DLVO forces in the region but it conforms to theoretical predictions after ~125 nm onwards. The proposed automation analysis tool will be powerfully employed in the bio-application fields needed for examination of single protein (DNA and/or vesicle) tracking, drug delivery, and cyto-toxicity unlike the traditional measurement techniques that require fixing the cells. Furthermore, this tool can be also usefully applied for the microfluidic areas of non-invasive thermometry, particle tracking velocimetry (PTV), and non-invasive viscometry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: It is yet unclear if there are differences between using electronic key feature problems (KFPs) or electronic case-based multiple choice questions (cbMCQ) for the assessment of clinical decision making. Summary of Work: Fifth year medical students were exposed to clerkships which ended with a summative exam. Assessment of knowledge per exam was done by 6-9 KFPs, 9-20 cbMCQ and 9-28 MC questions. Each KFP consisted of a case vignette and three key features (KF) using “long menu” as question format. We sought students’ perceptions of the KFPs and cbMCQs in focus groups (n of students=39). Furthermore statistical data of 11 exams (n of students=377) concerning the KFPs and (cb)MCQs were compared. Summary of Results: The analysis of the focus groups resulted in four themes reflecting students’ perceptions of KFPs and their comparison with (cb)MCQ: KFPs were perceived as (i) more realistic, (ii) more difficult, (iii) more motivating for the intense study of clinical reasoning than (cb)MCQ and (iv) showed an overall good acceptance when some preconditions are taken into account. The statistical analysis revealed that there was no difference in difficulty; however KFP showed a higher discrimination and reliability (G-coefficient) even when corrected for testing times. Correlation of the different exam parts was intermediate. Conclusions: Students perceived the KFPs as more motivating for the study of clinical reasoning. Statistically KFPs showed a higher discrimination and higher reliability than cbMCQs. Take-home messages: Including KFPs with long menu questions into summative clerkship exams seems to offer positive educational effects.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fragestellung/Einleitung: Es ist unklar inwiefern Unterschiede bestehen im Einsatz von Key Feature Problemen (KFP) mit Long Menu Fragen und fallbasierten Typ A Fragen (FTA) für die Überprüfung des klinischen Denkens (Clinical Reasoning) in der klinischen Ausbildung von Medizinstudierenden. Methoden: Medizinstudierende des fünften Studienjahres nahmen an ihrer klinischen Pädiatrie-Rotation teil, die mit einer summativen Prüfung endete. Die Überprüfung des Wissen wurde pro Prüfung elektronisch mit 6-9 KFP [1], [3], 9-20 FTA und 9-28 nichtfallbasierten Multiple Choice Fragen (NFTA) durchgeführt. Jedes KFP bestand aus einer Fallvignette und drei Key Features und nutzen ein sog. Long Menu [4] als Antwortformat. Wir untersuchten die Perzeption der KFP und FTA in Focus Gruppen [2] (n of students=39). Weiterhin wurden die statistischen Kennwerte der KFP und FTA von 11 Prüfungen (n of students=377) verglichen. Ergebnisse: Die Analyse der Fokusgruppen resultierte in vier Themen, die die Perzeption der KFP und deren Vergleich mit FTA darstellten: KFP wurden als 1. realistischer, 2. schwerer, und 3. motivierender für das intensive Selbststudium des klinischen Denkens als FTA aufgenommen und zeigten 4. insgesamt eine gute Akzeptanz sofern gewisse Voraussetzungen berücksichtigt werden. Die statistische Auswertung zeigte keinen Unterschied im Schwierigkeitsgrad; jedoch zeigten die KFP eine höhere Diskrimination und Reliabilität (G-coefficient) selbst wenn für die Prüfungszeit korrigiert wurde. Die Korrelation der verschiedenen Prüfungsteile war mittel. Diskussion/Schlussfolgerung: Die Studierenden erfuhren die KFP als motivierenden für das Selbststudium des klinischen Denkens. Statistisch zeigten die KFP eine grössere Diskrimination und höhere Relibilität als die FTA. Der Einbezug von KFP mit Long Menu in Prüfungen des klinischen Studienabschnitts erscheint vielversprechend und einen „educational effect“ zu haben.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Classical imaging optics has been developed over centuries in many areas, such as its paraxial imaging theory and practical design methods like multi-parametric optimization techniques. Although these imaging optical design methods can provide elegant solutions to many traditional optical problems, there are more and more new design problems, like solar concentrator, illumination system, ultra-compact camera, etc., that require maximum energy transfer efficiency, or ultra-compact optical structure. These problems do not have simple solutions from classical imaging design methods, because not only paraxial rays, but also non-paraxial rays should be well considered in the design process. Non-imaging optics is a newly developed optical discipline, which does not aim to form images, but to maximize energy transfer efficiency. One important concept developed from non-imaging optics is the “edge-ray principle”, which states that the energy flow contained in a bundle of rays will be transferred to the target, if all its edge rays are transferred to the target. Based on that concept, many CPC solar concentrators have been developed with efficiency close to the thermodynamic limit. When more than one bundle of edge-rays needs to be considered in the design, one way to obtain solutions is to use SMS method. SMS stands for Simultaneous Multiple Surface, which means several optical surfaces are constructed simultaneously. The SMS method was developed as a design method in Non-imaging optics during the 90s. The method can be considered as an extension to the Cartesian Oval calculation. In the traditional Cartesian Oval calculation, one optical surface is built to transform an input wave-front to an out-put wave-front. The SMS method however, is dedicated to solve more than 1 wave-fronts transformation problem. In the beginning, only 2 input wave-fronts and 2 output wave-fronts transformation problem was considered in the SMS design process for rotational optical systems or free-form optical systems. Usually “SMS 2D” method stands for the SMS procedure developed for rotational optical system, and “SMS 3D” method for the procedure for free-form optical system. Although the SMS method was originally employed in non-imaging optical system designs, it has been found during this thesis that with the improved capability to design more surfaces and control more input and output wave-fronts, the SMS method can also be applied to imaging system designs and possesses great advantage over traditional design methods. In this thesis, one of the main goals to achieve is to further develop the existing SMS-2D method to design with more surfaces and improve the stability of the SMS-2D and SMS-3D algorithms, so that further optimization process can be combined with SMS algorithms. The benefits of SMS plus optimization strategy over traditional optimization strategy will be explained in details for both rotational and free-form imaging optical system designs. Another main goal is to develop novel design concepts and methods suitable for challenging non-imaging applications, e.g. solar concentrator and solar tracker. This thesis comprises 9 chapters and can be grouped into two parts: the first part (chapter 2-5) contains research works in the imaging field, and the second part (chapter 6-8) contains works in the non-imaging field. In the first chapter, an introduction to basic imaging and non-imaging design concepts and theories is given. Chapter 2 presents a basic SMS-2D imaging design procedure using meridian rays. In this chapter, we will set the imaging design problem from the SMS point of view, and try to solve the problem numerically. The stability of this SMS-2D design procedure will also be discussed. The design concepts and procedures developed in this chapter lay the path for further improvement. Chapter 3 presents two improved SMS 3 surfaces’ design procedures using meridian rays (SMS-3M) and skew rays (SMS-1M2S) respectively. The major improvement has been made to the central segments selections, so that the whole SMS procedures become more stable compared to procedures described in Chapter 2. Since these two algorithms represent two types of phase space sampling, their image forming capabilities are compared in a simple objective design. Chapter 4 deals with an ultra-compact SWIR camera design with the SMS-3M method. The difficulties in this wide band camera design is how to maintain high image quality meanwhile reduce the overall system length. This interesting camera design provides a playground for the classical design method and SMS design methods. We will show designs and optical performance from both classical design method and the SMS design method. Tolerance study is also given as the end of the chapter. Chapter 5 develops a two-stage SMS-3D based optimization strategy for a 2 freeform mirrors imaging system. In the first optimization phase, the SMS-3D method is integrated into the optimization process to construct the two mirrors in an accurate way, drastically reducing the unknown parameters to only few system configuration parameters. In the second optimization phase, previous optimized mirrors are parameterized into Qbfs type polynomials and set up in code V. Code V optimization results demonstrates the effectiveness of this design strategy in this 2-mirror system design. Chapter 6 shows an etendue-squeezing condenser optics, which were prepared for the 2010 IODC illumination contest. This interesting design employs many non-imaging techniques such as the SMS method, etendue-squeezing tessellation, and groove surface design. This device has theoretical efficiency limit as high as 91.9%. Chapter 7 presents a freeform mirror-type solar concentrator with uniform irradiance on the solar cell. Traditional parabolic mirror concentrator has many drawbacks like hot-pot irradiance on the center of the cell, insufficient use of active cell area due to its rotational irradiance pattern and small acceptance angle. In order to conquer these limitations, a novel irradiance homogenization concept is developed, which lead to a free-form mirror design. Simulation results show that the free-form mirror reflector has rectangular irradiance pattern, uniform irradiance distribution and large acceptance angle, which confirm the viability of the design concept. Chapter 8 presents a novel beam-steering array optics design strategy. The goal of the design is to track large angle parallel rays by only moving optical arrays laterally, and convert it to small angle parallel output rays. The design concept is developed as an extended SMS method. Potential applications of this beam-steering device are: skylights to provide steerable natural illumination, building integrated CPV systems, and steerable LED illumination. Conclusion and future lines of work are given in Chapter 9. Resumen La óptica de formación de imagen clásica se ha ido desarrollando durante siglos, dando lugar tanto a la teoría de óptica paraxial y los métodos de diseño prácticos como a técnicas de optimización multiparamétricas. Aunque estos métodos de diseño óptico para formación de imagen puede aportar soluciones elegantes a muchos problemas convencionales, siguen apareciendo nuevos problemas de diseño óptico, concentradores solares, sistemas de iluminación, cámaras ultracompactas, etc. que requieren máxima transferencia de energía o dimensiones ultracompactas. Este tipo de problemas no se pueden resolver fácilmente con métodos clásicos de diseño porque durante el proceso de diseño no solamente se deben considerar los rayos paraxiales sino también los rayos no paraxiales. La óptica anidólica o no formadora de imagen es una disciplina que ha evolucionado en gran medida recientemente. Su objetivo no es formar imagen, es maximazar la eficiencia de transferencia de energía. Un concepto importante de la óptica anidólica son los “rayos marginales”, que se pueden utilizar para el diseño de sistemas ya que si todos los rayos marginales llegan a nuestra área del receptor, todos los rayos interiores también llegarán al receptor. Haciendo uso de este principio, se han diseñado muchos concentradores solares que funcionan cerca del límite teórico que marca la termodinámica. Cuando consideramos más de un haz de rayos marginales en nuestro diseño, una posible solución es usar el método SMS (Simultaneous Multiple Surface), el cuál diseña simultáneamente varias superficies ópticas. El SMS nació como un método de diseño para óptica anidólica durante los años 90. El método puede ser considerado como una extensión del cálculo del óvalo cartesiano. En el método del óvalo cartesiano convencional, se calcula una superficie para transformar un frente de onda entrante a otro frente de onda saliente. El método SMS permite transformar varios frentes de onda de entrada en frentes de onda de salida. Inicialmente, sólo era posible transformar dos frentes de onda con dos superficies con simetría de rotación y sin simetría de rotación, pero esta limitación ha sido superada recientemente. Nos referimos a “SMS 2D” como el método orientado a construir superficies con simetría de rotación y llamamos “SMS 3D” al método para construir superficies sin simetría de rotación o free-form. Aunque el método originalmente fue aplicado en el diseño de sistemas anidólicos, se ha observado que gracias a su capacidad para diseñar más superficies y controlar más frentes de onda de entrada y de salida, el SMS también es posible aplicarlo a sistemas de formación de imagen proporcionando una gran ventaja sobre los métodos de diseño tradicionales. Uno de los principales objetivos de la presente tesis es extender el método SMS-2D para permitir el diseño de sistemas con mayor número de superficies y mejorar la estabilidad de los algoritmos del SMS-2D y SMS-3D, haciendo posible combinar la optimización con los algoritmos. Los beneficios de combinar SMS y optimización comparado con el proceso de optimización tradicional se explican en detalle para sistemas con simetría de rotación y sin simetría de rotación. Otro objetivo importante de la tesis es el desarrollo de nuevos conceptos de diseño y nuevos métodos en el área de la concentración solar fotovoltaica. La tesis está estructurada en 9 capítulos que están agrupados en dos partes: la primera de ellas (capítulos 2-5) se centra en la óptica formadora de imagen mientras que en la segunda parte (capítulos 6-8) se presenta el trabajo del área de la óptica anidólica. El primer capítulo consta de una breve introducción de los conceptos básicos de la óptica anidólica y la óptica en formación de imagen. El capítulo 2 describe un proceso de diseño SMS-2D sencillo basado en los rayos meridianos. En este capítulo se presenta el problema de diseñar un sistema formador de imagen desde el punto de vista del SMS y se intenta obtener una solución de manera numérica. La estabilidad de este proceso se analiza con detalle. Los conceptos de diseño y los algoritmos desarrollados en este capítulo sientan la base sobre la cual se realizarán mejoras. El capítulo 3 presenta dos procedimientos para el diseño de un sistema con 3 superficies SMS, el primero basado en rayos meridianos (SMS-3M) y el segundo basado en rayos oblicuos (SMS-1M2S). La mejora más destacable recae en la selección de los segmentos centrales, que hacen más estable todo el proceso de diseño comparado con el presentado en el capítulo 2. Estos dos algoritmos representan dos tipos de muestreo del espacio de fases, su capacidad para formar imagen se compara diseñando un objetivo simple con cada uno de ellos. En el capítulo 4 se presenta un diseño ultra-compacto de una cámara SWIR diseñada usando el método SMS-3M. La dificultad del diseño de esta cámara de espectro ancho radica en mantener una alta calidad de imagen y al mismo tiempo reducir drásticamente sus dimensiones. Esta cámara es muy interesante para comparar el método de diseño clásico y el método de SMS. En este capítulo se presentan ambos diseños y se analizan sus características ópticas. En el capítulo 5 se describe la estrategia de optimización basada en el método SMS-3D. El método SMS-3D calcula las superficies ópticas de manera precisa, dejando sólo unos pocos parámetros libres para decidir la configuración del sistema. Modificando el valor de estos parámetros se genera cada vez mediante SMS-3D un sistema completo diferente. La optimización se lleva a cabo variando los mencionados parámetros y analizando el sistema generado. Los resultados muestran que esta estrategia de diseño es muy eficaz y eficiente para un sistema formado por dos espejos. En el capítulo 6 se describe un sistema de compresión de la Etendue, que fue presentado en el concurso de iluminación del IODC en 2010. Este interesante diseño hace uso de técnicas propias de la óptica anidólica, como el método SMS, el teselado de las lentes y el diseño mediante grooves. Este dispositivo tiene un límite teórica en la eficiencia del 91.9%. El capítulo 7 presenta un concentrador solar basado en un espejo free-form con irradiancia uniforme sobre la célula. Los concentradores parabólicos tienen numerosas desventajas como los puntos calientes en la zona central de la célula, uso no eficiente del área de la célula al ser ésta cuadrada y además tienen ángulos de aceptancia de reducido. Para poder superar estas limitaciones se propone un novedoso concepto de homogeneización de la irrandancia que se materializa en un diseño con espejo free-form. El análisis mediante simulación demuestra que la irradiancia es homogénea en una región rectangular y con mayor ángulo de aceptancia, lo que confirma la viabilidad del concepto de diseño. En el capítulo 8 se presenta un novedoso concepto para el diseño de sistemas afocales dinámicos. El objetivo del diseño es realizar un sistema cuyo haz de rayos de entrada pueda llegar con ángulos entre ±45º mientras que el haz de rayos a la salida sea siempre perpendicular al sistema, variando únicamente la posición de los elementos ópticos lateralmente. Las aplicaciones potenciales de este dispositivo son varias: tragaluces que proporcionan iluminación natural, sistemas de concentración fotovoltaica integrados en los edificios o iluminación direccionable con LEDs. Finalmente, el último capítulo contiene las conclusiones y las líneas de investigación futura.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this work, we demonstrate how it is possible to sharply image multiple object points. The Simultaneous Multiple Surface (SMS) design method has usually been presented as a method to couple N wave-front pairs with N surfaces, but recent findings show that when using N surfaces, we can obtain M image points when Nmethod, from its basics, to imaging two object points through one surface, the transition from two to three objet points obtained by increasing the parallelism, and getting to the designs of six surfaces imaging up to eight object points. These designs are limited with the condition that the surfaces cannot be placed at the aperture stop. In the process of maximizing the object points to sharp image, we try to exhaust the degrees of freedom of aspherics and free-forms. We conjecture that maximal SMS designs are very close to a good solution, hence using them as a starting point for the optimization will lead us faster to a final optical system. We suggest here different optimization strategies which combined with the SMS method are proven to give the best solution. Through the example of imaging with the high aspect ratio, we compare the results obtained optimizing the rotational lens and using a combination of SMS method and optimization, showing that the second approach is giving significantly smaller value of overall RMS spot diameter.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The McCabe-Thiele method is a classical approximate graphical method for the conceptual design of binary distillation columns which is still widely used, mainly for didactical purposes, though it is also valuable for quick preliminary calculations. Nevertheless, no complete description of the method has been found and situations such as different thermal feed conditions, multiple feeds, possibilities to extract by-products or to add or remove heat, are not always considered. In the present work we provide a systematic analysis of such situations by developing the generalized equations for: a) the operating lines (OL) of each sector, and b) the changeover line that provides the connection between two consecutive trays of the corresponding sectors separated by a lateral stream of feed, product, or a heat removal or addition.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Although the aim of conservation planning is the persistence of biodiversity, current methods trade-off ecological realism at a species level in favour of including multiple species and landscape features. For conservation planning to be relevant, the impact of landscape configuration on population processes and the viability of species needs to be considered. We present a novel method for selecting reserve systems that maximize persistence across multiple species, subject to a conservation budget. We use a spatially explicit metapopulation model to estimate extinction risk, a function of the ecology of the species and the amount, quality and configuration of habitat. We compare our new method with more traditional, area-based reserve selection methods, using a ten-species case study, and find that the expected loss of species is reduced 20-fold. Unlike previous methods, we avoid designating arbitrary weightings between reserve size and configuration; rather, our method is based on population processes and is grounded in ecological theory.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Quantum dots (Qdots) are fluorescent nanoparticles that have great potential as detection agents in biological applications. Their optical properties, including photostability and narrow, symmetrical emission bands with large Stokes shifts, and the potential for multiplexing of many different colours, give them significant advantages over traditionally used fluorescent dyes. Here, we report the straightforward generation of stable, covalent quantum dot-protein A/G bioconjugates that will be able to bind to almost any IgG antibody, and therefore can be used in many applications. An additional advantage is that the requirement for a secondary antibody is removed, simplifying experimental design. To demonstrate their use, we show their application in multiplexed western blotting. The sensitivity of Qdot conjugates is found to be superior to fluorescent dyes, and comparable to, or potentially better than, enhanced chemiluminescence. We show a true biological validation using a four-colour multiplexed western blot against a complex cell lysate background, and have significantly improved previously reported non-specific binding of the Qdots to cellular proteins.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper a new method which is a generalization of the Ehrlich-Kjurkchiev method is developed. The method allows to find simultaneously all roots of the algebraic equation in the case when the roots are supposed to be multiple with known multiplicities. The offered generalization does not demand calculation of derivatives of order higher than first simultaneously keeping quaternary rate of convergence which makes this method suitable for application from practical point of view.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new 3D implementation of a hybrid model based on the analogy with two-phase hydrodynamics has been developed for the simulation of liquids at microscale. The idea of the method is to smoothly combine the atomistic description in the molecular dynamics zone with the Landau-Lifshitz fluctuating hydrodynamics representation in the rest of the system in the framework of macroscopic conservation laws through the use of a single "zoom-in" user-defined function s that has the meaning of a partial concentration in the two-phase analogy model. In comparison with our previous works, the implementation has been extended to full 3D simulations for a range of atomistic models in GROMACS from argon to water in equilibrium conditions with a constant or a spatially variable function s. Preliminary results of simulating the diffusion of a small peptide in water are also reported.