946 resultados para Monolithic HPLC


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the first hybrid mode-locking of a monolithic two-section multiple quantum well InGaN based laser diode. This device, with a length of 1.5 mm, has a 50-μm-long absorber section located at the back facet and generates a continuous stable 28.6 GHz pulse train with an average output power of 9.4 mW at an emission wavelength of 422 nm. Under hybrid mode-locking, the pulse width reduces to 4 ps, the peak power increases to 72 mW, and the microwave linewidth reduces by 13 dB to <500 kHz. We also observe the passive mode-locking with pulse width and peak power of 8 ps and 37 mW, respectively. © 1989-2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report 4ps and 8ps pulse generation from a two-section monolithic InGaN/GaN laser by hybrid and passive mode-locking, respectively. Pulse trains at a repetition rate of 28.6GHz and an emission wavelength of 422nm are generated. © 2013 The Optical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new amino silica monolithic column was developed for DNA extraction in a miniaturized format. The monolithic column was prepared in situ by polymerization of tetraethoxysilane (TEOS) and N-(beta-aminoethyl)-gamma-aminopropylmethyldimethoxysilane (AEAPMDMS). DNA was loaded in 50 mM tris(hydroxylmethyl)aminomethane-EDTA buffer at pH 7.0 and eluted with 300 mM potassium phosphate solution at pH 10.0. Under optimal condition, a 6.0-cm monolithic column provided a capacity of 56 ng DNA with an extraction efficiency of 71 +/- 5.2% (X +/- RSD). When the amino silica monolithic column was applied to extract genomic DNA from the whole blood of crucian carp, an extraction efficiency of 52 +/- 5.6% (X +/- SD) was obtained by three extractions. Since the chaotropic-based sample loading and organic solvent wash steps were avoided in this procedure, the purified DNA was suitable for downstream processes such as PCR. This amino silica monolithic column was demonstrated to allow rapid and efficient DNA purification in microscale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A technique enabling 10 Gbps data to be directly modulated onto a monolithic sub-THz dual laser transmitter is proposed. As a result of the laser chirp, the logical zeros of the resultant sub-THz signal have a different peak frequency from that of the logical ones. The signal extinction ratio is therefore enhanced by suppressing the logical zeros with a filter stage at the receiver. With the aid of the chirp-enhanced filtering, an improved extinction ratio can be achieved at moderate modulation current. Hence, 10 GHz modulation bandwidth of the transmitter is predicted without the need for external modulators. In this paper, we demonstrate the operational principle by generating an error-free (bit error rate less than 10-9) 100 Mbps Manchester encoded signal with a centre frequency of 12 GHz within the bandwidth of an envelope detector, whilst direct modulation of a 100 GHz signal at data rates of up to 10 Gbps is simulated by using a transmission line model. This work could be a key technique for enabling monolithic sub-THz transmitters to be readily used in high speed wireless links. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An integrated EOM VCSELs is shown to offer high linearity (92dB/Hz2/3 at 6GHz) and by extrapolation ~90dB/Hz2/3 up to 20GHz. Successful modulation with IEEE 802.11g signals is demonstrated at 6GHz with a 12dB dynamic range. © OSA/OFC/NFOEC 2011.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the first experimental demonstration of a monolithically integrated hybrid dilated 2×2 modular optical switch using Mach-Zehnder modulators as low-loss 1×2 switching elements and short semiconductor optical amplifiers to provide additional extinction and gain. An excellent 40 dB cross-talk/extinction ratio is recorded with data-modulated signal-to-noise ratios of up to 44 dB in a 0.1 nm bandwidth. A switching time of 3 ns is demonstrated. Bit error rate studies show extremely low subsystem penalties of less than 0.1 dB, and studies indicate that, by using this hybrid switch building block, an 8×8 port switch could be achieved with 14 dB input power dynamic range for subsystem penalties of less than 0.5 dB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A monolithic design is proposed for low-noise sub-THz signal generation by integrating a reflector onto a dual laser source. The reflectivity and the position of such a reflector can be adjusted to obtain constructive feedback from the reflector to both lasers, thus causing a Vernier feedback effect. As a result, 10-fold line narrowing, the narrowing being limited by the resolution of the simulation, is predicted using a transmission line model. Finally, a simple control scheme using an electrical feedback loop to adjust laser biases is proposed to maintain the line narrowing performance. This line narrowing technique, comprising a passive integrated reflector, could allow the development of a low-cost, compact and energy-efficient solution for high-purity sub-THz signal generation. © The Institution of Engineering and Technology 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The antibacterial drug furazolidone belonging to the group of nitrofuran antibacterial agents has been widely used as an antibacterial and antiprotozoal feed additive for poultry, cattle, and farmed fish in China. During application a large proportion of the administered drug may reach the environment directly or via feces. Although the use of furazolidone is prohibited in numerous countries, there are indications of its illegal use. It is known that furazolidone can be rapidly metabolized to 3-amino-2-oxazolidinone (AOZ) in the body of the target organism. In this study, a total of 21 fish feed samples, including 17 commercial fish feeds from local markets in China (representing 15 different formulations) and 4 fish feeds obtained from Germany and Turkey, respectively, are analyzed to determine whether the drug is still illegally used or commercially available feeds are contaminated by this drug. High-performance liquid chromatography (HPLC) and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) methods have been implemented to determine furazolidone and its metabolite AOZ in fish feeds containing animal protein, respectively. An efficient and convenient cleanup method for the determination of furazolidone in fish feeds is developed, and a simple cleanup method for the determination of AOZ is used. Method recoveries for samples used were determined as 87.7-98.3% for furazolidone at two spike levels of 2.0 and 5.0 ng g(-1) and as 95.6-102.8% for AOZ at spike levels of 0.4 and 0.8 ng g(-1). Limits of detections were 0.4 ng g(-1) for furazolidone and 0.05 ng g(-1) for AOZ. The established methods are therefore suitable for the determination of furazolidone and its metabolite AOZ in fish feeds at trace contamination levels. Using the established methods, all fish feed samples have been proved to be furazolidone negative; however, AOZ is tested in 16 of 17 fish feeds obtained from local markets in the Hubei province of China, with a positive rate as high as 94.1%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The control plane is implemented for the first time to allow scheduling and power leveling in a monolithic 8×8 space and wavelength selective cross-connect. 16 dynamic data connections are established within 16μs. © 2013 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FM mode-locking in monolithic semiconductor lasers is investigated for the first time, using a travelling-wave laser model. The effects of phase modulation depth and non-zero alpha factor on pulse quality and pulse-width are discussed. © 2004 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FM mode-locking in monolithic semiconductor lasers is investigated for the first time, using a travelling-wave laser model. The effects of phase modulation depth and non-zero alpha factor on pulse quality and pulse-width are discussed. © 2004 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantum-dot active material systems are proving to be an excellent choice for mode-locked laser applications. High-power, high repetition-rate picosecond and sub-picosecond pulse generation is now readily achievable with promising results for ultra-low jitter performance. © 2006 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RP-HPLC analysis for low molecular weight organic acids in soil solution has been optimized. An Atlantis (TM) C-18 column was used for the analyses. An optimal determination for eleven organic acids in soil solution was found at room temperature (25 degrees C) and 220 nm detection wavelength, with a mobile phase of 10 mM KH2PO4 -CH3OH (955, pH 2.7), a flow rate of 0.8 mL/min and 10 mu L sample size. The detection limits ranged 3.2-619 ng/mL, the coefficients of variation ranged 1.3-4.6%, and the recoveries ranged 95.6-106.3% for soil solution with standard addition on the optimal conditions proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the monolithic integration of a sampled-grating distributed Bragg reflector (SC-DBR) laser with a quantum-well electroabsorption modulator (QW-EAM) by combining ultra-low-pressure (55 mbar) selective-area-growth (SAG) metal-organic chemical vapour deposition (MOCVD) and quantum-well intermixing (QWI) for the first time. The QW-EAM and the gain section can be grown simultaneously by using SAG MOCVD technology. Meanwhile, the QWI technology offers an abrupt band-gap change between two functional sections, which reduces internal absorption loss. The experimental results show that the threshold current I-th = 62 mA, and output power reaches 3.6 mW. The wavelength tuning range covers 30 nm, and all the corresponding side mode suppression ratios are over 30 dB. The extinction ratios at available wavelength channels can reach more than 14 dB with bias of -5 V.