973 resultados para Modified surfaces
Resumo:
To evaluate the rate and degree of osseointegration at chemically modified moderately rough, hydrophilic (SLActive) and moderately rough, hydrophobic (SLA) implant surfaces during early phases of healing in a human model.
Resumo:
A minimal marginal bone loss around implants during early healing has been considered acceptable. However, the preservation of the marginal bone is related to soft tissue stability and esthetics. Implant designs and surfaces were evaluated to determine their impact on the behavior of the crestal bone. The purpose of this study is to evaluate histologic marginal bone level changes around early loaded, chemically modified, sandblasted acid-etched-surfaced implants with a machined collar (MC) or no MC (NMC).
Resumo:
The Advanced Very High Resolution Radiometer (AVHRR) carried on board the National Oceanic and Atmospheric Administration (NOAA) and the Meteorological Operational Satellite (MetOp) polar orbiting satellites is the only instrument offering more than 25 years of satellite data to analyse aerosols on a daily basis. The present study assessed a modified AVHRR aerosol optical depth τa retrieval over land for Europe. The algorithm might also be applied to other parts of the world with similar surface characteristics like Europe, only the aerosol properties would have to be adapted to a new region. The initial approach used a relationship between Sun photometer measurements from the Aerosol Robotic Network (AERONET) and the satellite data to post-process the retrieved τa. Herein a quasi-stand-alone procedure, which is more suitable for the pre-AERONET era, is presented. In addition, the estimation of surface reflectance, the aerosol model, and other processing steps have been adapted. The method's cross-platform applicability was tested by validating τa from NOAA-17 and NOAA-18 AVHRR at 15 AERONET sites in Central Europe (40.5° N–50° N, 0° E–17° E) from August 2005 to December 2007. Furthermore, the accuracy of the AVHRR retrieval was related to products from two newer instruments, the Medium Resolution Imaging Spectrometer (MERIS) on board the Environmental Satellite (ENVISAT) and the Moderate Resolution Imaging Spectroradiometer (MODIS) on board Aqua/Terra. Considering the linear correlation coefficient R, the AVHRR results were similar to those of MERIS with even lower root mean square error RMSE. Not surprisingly, MODIS, with its high spectral coverage, gave the highest R and lowest RMSE. Regarding monthly averaged τa, the results were ambiguous. Focusing on small-scale structures, R was reduced for all sensors, whereas the RMSE solely for MERIS substantially increased. Regarding larger areas like Central Europe, the error statistics were similar to the individual match-ups. This was mainly explained with sampling issues. With the successful validation of AVHRR we are now able to concentrate on our large data archive dating back to 1985. This is a unique opportunity for both climate and air pollution studies over land surfaces.
Resumo:
Enhancing osseointegration through surface immobilization of multiple short peptide sequences that mimic extracellular matrix (ECM) proteins, such as arginine-glycine-aspartic acid (RGD) and lysine-arginine-serine-arginine (KRSR), has not yet been extensively explored. Additionally, the effect of biofunctionalizing chemically modified sandblasted and acid-etched surfaces (modSLA) is unknown. The present study evaluated modSLA implant surfaces modified with RGD and KRSR for potentially enhanced effects on bone apposition and interfacial shear strength during early stages of bone regeneration. Two sets of experimental implants were placed in the maxillae of eight miniature pigs, known for their rapid wound healing kinetics: bone chamber implants creating two circular bone defects for histomorphometric analysis on one side and standard thread configuration implants for removal torque testing on the other side. Three different biofunctionalized modSLA surfaces using poly-L-lysine-graft-poly(ethylene glycol) (PLL-g-PEG) as a carrier minimizing nonspecific protein adsorption [(i) 20 pmol cm⁻² KRSR alone (KRSR); or in combination with RGD in two different concentrations; (ii) 0.05 pmol cm⁻² RGD (KRSR/RGD-1); (iii) 1.26 pmol cm⁻² RGD (KRSR/RGD-2)] were compared with (iv) control modSLA. Animals were sacrificed at 2 weeks. Removal torque values (701.48-780.28 N mm), bone-to-implant contact (BIC) (35.22%-41.49%), and new bone fill (28.58%-30.62%) demonstrated no significant differences among treatments. It may be concluded that biofunctionalizing modSLA surfaces with KRSR and RGD derivatives of PLL-g-PEG polymer does not increase BIC, bone fill, or interfacial shear strength.
Resumo:
Microrough titanium (Ti) surfaces of dental implants have demonstrated more rapid and greater bone apposition when compared with machined Ti surfaces. However, further enhancement of osteoblastic activity and bone apposition by bio-functionalizing the implant surface with a monomolecular adsorbed layer of a co-polymer - i.e., poly(L-lysine)-graft-poly(ethylene glycol) (PLL-g-PEG) and its derivatives (PLL-g-PEG/PEG-peptide) - has never been investigated. The aim of the present study was to examine early bone apposition to a modified sandblasted and acid-etched (SLA) surface coated with an Arg-Gly-Asp (RGD)-peptide-modified polymer (PLL-g-PEG/PEG-RGD) in the maxillae of miniature pigs, and to compare it with the standard SLA surface. Test and control implants had the same microrough topography (SLA), but differed in their surface chemistry (polymer coatings). The following surfaces were examined histomorphometrically: (i) control - SLA without coating; (ii) (PLL-g-PEG); (iii) (PLL-g-PEG/PEG-RDG) (RDG, Arg-Asp-Gly); and (iv) (PLL-g-PEG/PEG-RGD). At 2 weeks, RGD-coated implants demonstrated significantly higher percentages of bone-to-implant contact as compared with controls (61.68% vs. 43.62%; P < 0.001). It can be concluded that the (PLL-g-PEG/PEG-RGD) coatings may promote enhanced bone apposition during the early stages of bone regeneration.
Resumo:
The functional capacity of osseointegrated dental implants to bear load is largely dependent on the quality of the interface between the bone and implant. Sandblasted and acid-etched (SLA) surfaces have been previously shown to enhance bone apposition. In this study, the SLA has been compared with a chemically modified SLA (modSLA) surface. The increased wettability of the modSLA surface in a protein solution was verified by dynamic contact angle analysis. Using a well-established animal model with a split-mouth experimental design, implant removal torque testing was performed to determine the biomechanical properties of the bone-implant interface. All implants had an identical cylindrical shape with a standard thread configuration. Removal torque testing was performed after 2, 4, and 8 weeks of bone healing (n = 9 animals per healing period, three implants per surface type per animal) to evaluate the interfacial shear strength of each surface type. Results showed that the modSLA surface was more effective in enhancing the interfacial shear strength of implants in comparison with the conventional SLA surface during early stages of bone healing. Removal torque values of the modSLA-surfaced implants were 8-21% higher than those of the SLA implants (p = 0.003). The mean removal torque values for the modSLA implants were 1.485 N m at 2 weeks, 1.709 N m at 4 weeks, and 1.345 N m at 8 weeks; and correspondingly, 1.231 N m, 1.585 N m, and 1.143 N m for the SLA implants. The bone-implant interfacial stiffness calculated from the torque-rotation curve was on average 9-14% higher for the modSLA implants when compared with the SLA implants (p = 0.038). It can be concluded that the modSLA surface achieves a better bone anchorage during early stages of bone healing than the SLA surface; chemical modification of the standard SLA surface likely enhances bone apposition and this has a beneficial effect on the interfacial shear strength.
Resumo:
In the past, several modifications of specific surface properties such as topography, structure, chemistry, surface charge, and wettability have been investigated to predictably improve the osseointegration of titanium implants. The aim of the present review was to evaluate, based on the currently available evidence, the impact of hydrophilic surface modifications of titanium for dental implants. A surface treatment was performed to produce hydroxylated/hydrated titanium surfaces with identical microstructure to either acid-etched, or sand-blasted, large grit and acid-etched substrates, but with hydrophilic character. Preliminary in vitro studies have indicated that the specific properties noted for hydrophilic titanium surfaces have a significant influence on cell differentiation and growth factor production. Animal experiments have pointed out that hydrophilic surfaces improve early stages of soft tissue and hard tissue integration of either nonsubmerged or submerged titanium implants. This data was also corroborated by the results from preliminary clinical studies. In conclusion, the present review has pointed to a potential of hydrophilic surface modifications to support tissue integration of titanium dental implants.
Resumo:
PURPOSE: The aim of this study was to evaluate bone apposition to a modified sandblasted and acid-etched (SLA) implant surface (modSLA) in the canine mandible as compared with the standard SLA surface. MATERIAL AND METHODS: In this experimental study, all mandibular premolars and first molars were extracted bilaterally in five foxhounds. After a healing period of 6 months, each side of the mandible received six randomly assigned dental implants alternating between the standard SLA and modSLA surface. The dogs were sacrificed at 2 weeks (n=2) or 4 weeks (n=3) after implant placement. Histologic and histomorphometric analyses were then performed for each implant. RESULTS: The microscopic healing patterns at weeks 2 and 4 for the two implant types with the standard SLA and modSLA surfaces showed similar qualitative findings. New bone tissue had already established direct contact with implant surfaces after 2 weeks of healing. The mean percentage of newly formed bone in contact with the implant (BIC) was significantly greater for modSLA (28.2+/-7.9%) than for SLA (22.2+/-7.3%) (P<0.05). This difference was no longer evident after 4 weeks. An increase in BIC for both implant surface types occurred from weeks 2 to 4. This increase was statistically significant when compared with SLA at 2 weeks (P<0.05), but not when compared with modSLA at 2 weeks. CONCLUSION: The data from the present study demonstrate significantly more bone apposition for the modSLA surface than the standard SLA surface after 2 weeks of healing. This increased bone apposition may allow a further reduction of the healing period following implant placement for patients undergoing early loading procedures.
Resumo:
Three cycles of erosion have modified the Boulder batholith. The earliest cycle produced a peneplaination that has been largely obliterated by a partially completed intermediate cycle, and the recent cycle now in progress.
Resumo:
INTRODUCTION Data concerning outcome after management of acetabular fractures by anterior approaches with focus on age and fractures associated with roof impaction, central dislocation and/or quadrilateral plate displacement are rare. METHODS Between October 2005 and April 2009 a series of 59 patients (mean age 57 years, range 13-91) with fractures involving the anterior column was treated using the modified Stoppa approach alone or for reduction of displaced iliac wing or low anterior column fractures in combination with the 1st window of the ilioinguinal approach or the modified Smith-Petersen approach, respectively. Surgical data, accuracy of reduction, clinical and radiographic outcome at mid-term and the need for endoprosthetic replacement in the postoperative course (defined as failure) were assessed; uni- and multivariate regression analysis were performed to identify independent predictive factors (e.g. age, nonanatomical reduction, acetabular roof impaction, central dislocation, quadrilateral plate displacement) for a failure. Outcome was assessed for all patients in general and in accordance to age in particular; patients were subdivided into two groups according to their age (group "<60yrs", group "≥60yrs"). RESULTS Forty-three of 59 patients (mean age 54yrs, 13-89) were available for evaluation. Of these, anatomic reduction was achieved in 72% of cases. Nonanatomical reduction was identified as being the only multivariate predictor for subsequent total hip replacement (Adjusted Hazard Ratio 23.5; p<0.01). A statistically significant higher rate of nonanatomical reduction was observed in the presence of acetabular roof impaction (p=0.01). In 16% of all patients, total hip replacement was performed and in 69% of patients with preserved hips the clinical results were excellent or good at a mean follow up of 35±10 months (range: 24-55). No statistical significant differences were observed between both groups. CONCLUSION Nonanatomical reconstruction of the articular surfaces is at risk for failure of joint-preserving management of acetabular fractures through an isolated or combined modified Stoppa approach resulting in total joint replacement at mid-term. In the elderly, joint-preserving surgery is worth considering as promising clinical and radiographic results might be obtained at mid-term.
Resumo:
OBJECTIVES To histologically and immunologically assess experimental peri-implant mucositis at surface enhanced modified (mod) hydrophilic titanium implants. MATERIALS AND METHODS In a split-mouth design (n = 6 foxhounds), four different implants were inserted on each side of the maxilla: three titanium-zirconium alloy implants (TiZr) with either modSLA (sand-blasted, acid etched and chemically mod), modMA (machined, acid etched and chemically mod), or M (machined) surfaces in the transmucosal portion, and one titanium implant with a machined transmucosal portion (TiM). Experimental mucositis was induced at one randomly assigned side (NPC), whereas the contra-lateral maxillary side received mechanical plaque removal three times per week (PC). At 16 weeks, tissue biopsies were processed for histological (primary outcome: apical extension of the inflammatory cell infiltrate measured from the mucosal margin - PM-aICT) and immunohistochemical (CD68 antigen reactivity) analyses. Peri-implant sulcus fluid was analysed for interleukin (IL)-1β, IL-8, matrix metalloproteinase (MMP)-8 and myeloperoxidase (MPO). RESULTS Mean PM-aICT values varied between 1.86 (TiZrmodSLA) and 3.40 mm (TiM) in the UPC group, and between 0.88 (TiZrmodSLA) and 2.08 mm (TiZrM) in the PC group. Mean CD68, IL-1β, IL-8, MMP-8 and MPO values were equally distributed between mod- and control implants in both NPC and PC groups. CONCLUSIONS The progression of experimental mucositis was comparable at all implant surfaces investigated.
Resumo:
Free transition metal ions oxidize lipids and lipoproteins in vitro; however, recent evidence suggests that free metal ion-independent mechanisms are more likely in vivo. We have shown previously that human ceruloplasmin (Cp), a serum protein containing seven Cu atoms, induces low density lipoprotein oxidation in vitro and that the activity depends on the presence of a single, chelatable Cu atom. We here use biochemical and molecular approaches to determine the site responsible for Cp prooxidant activity. Experiments with the His-specific reagent diethylpyrocarbonate (DEPC) showed that one or more His residues was specifically required. Quantitative [14C]DEPC binding studies indicated the importance of a single His residue because only one was exposed upon removal of the prooxidant Cu. Plasmin digestion of [14C]DEPC-treated Cp (and N-terminal sequence analysis of the fragments) showed that the critical His was in a 17-kDa region containing four His residues in the second major sequence homology domain of Cp. A full length human Cp cDNA was modified by site-directed mutagenesis to give His-to-Ala substitutions at each of the four positions and was transfected into COS-7 cells, and low density lipoprotein oxidation was measured. The prooxidant site was localized to a region containing His426 because CpH426A almost completely lacked prooxidant activity whereas the other mutants expressed normal activity. These observations support the hypothesis that Cu bound at specific sites on protein surfaces can cause oxidative damage to macromolecules in their environment. Cp may serve as a model protein for understanding mechanisms of oxidant damage by copper-containing (or -binding) proteins such as Cu, Zn superoxide dismutase, and amyloid precursor protein.
Resumo:
Poly(4-vinyl-N-alkylpyridinium bromide) was covalently attached to glass slides to create a surface that kills airborne bacteria on contact. The antibacterial properties were assessed by spraying aqueous suspensions of bacterial cells on the surface, followed by air drying and counting the number of cells remaining viable (i.e., capable of growing colonies). Amino glass slides were acylated with acryloyl chloride, copolymerized with 4-vinylpyridine, and N-alkylated with different alkyl bromides (from propyl to hexadecyl). The resultant surfaces, depending on the alkyl group, were able to kill up to 94 ± 4% of Staphylococcus aureus cells sprayed on them. A surface alternatively created by attaching poly(4-vinylpyridine) to a glass slide and alkylating it with hexyl bromide killed 94 ± 3% of the deposited S. aureus cells. On surfaces modified with N-hexylated poly(4-vinylpyridine), the numbers of viable cells of another Gram-positive bacterium, Staphylococcus epidermidis, as well as of the Gram-negative bacteria Pseudomonas aeruginosa and Escherichia coli, dropped more than 100-fold compared with the original amino glass. In contrast, the number of viable bacterial cells did not decline significantly after spraying on such common materials as ceramics, plastics, metals, and wood.
Resumo:
The adsorption of nitric oxide (NO) on a Pt (111) surface modified with irreversible adsorbed bismuth adatoms is reported. While the voltammetric results reveal a close interaction between the two co-adsorbed compounds. In-situ infrared spectroscopy and scanning tunnelling microscopy indicate the formation of segregated adlayers. Formation of compressed Bi adlayers with modified redox properties is proposed to reconcile both results. This agrees with the observation of Bi islands in the STM images when NO is coadsorbed, not observed in the absence of NO.
Resumo:
BACKGROUND As an alternative to the modified Stoppa approach, the Pararectus approach is used clinically for treatment of acetabular fractures involving the anterior column. The current study assessed the surgical exposure and the options for instrumentation using both of these approaches. METHODS Surgical dissections were conducted on five human cadavers (all male, mean age 88 years (82-97)) using the modified Stoppa and the Pararectus approach, with the same skin incision length (10cm). Distal boundaries of the exposed bony surfaces were marked using a chisel. After removal of all soft-tissues, distances from the boundaries in the false and true pelvis were measured with reference to the pelvic brim. The exposed bone was coloured and calibrated digital images of each inner hemipelvis were taken. The amount of exposed surface using both approaches was assessed and represented as a percentage of the total bony surface of each hemipelvis. For instrumentation, a suprapectineal quadrilateral buttress plate was used. Screw lengths were documented, and three-dimensional CT reconstructions were performed to assess screw trajectories qualitatively. Wilcoxon's signed rank test for paired groups was used (level of significance: p<0.05). RESULTS After utilization of the Pararectus approach, the distances from the farthest boundaries of exposed bone towards the pelvic brim were significantly higher in the false but not the true pelvis, compared to the modified Stoppa approach. The percentage (mean±SD) of exposed bone accessible after utilizing the Pararectus approach was 42±8%, compared to 29±6% using the modified Stoppa (p=0.011). In cadavers exposed by the Pararectus approach, screws placed for posterior fixation and as a posterior column screw were longer by factor 1.8 and 2.1, respectively (p<0.05), and screws could be placed more posteromedial towards the posterior inferior iliac spine or in line with the posterior column directed towards the ischial tuberosity. CONCLUSION Compared to the modified Stoppa, the Pararectus approach facilitates a greater surgical access in the false pelvis, provides versatility for fracture fixation in the posterior pelvic ring and allows for the option to extend the approach without a new incision.