966 resultados para Microscope confocal à balayage laser


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Biociências e Biotecnologia Aplicadas à Farmácia - FCFAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Ciências Odontológicas - FOAR

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the rate of visual field and optic disc change in patients with distinct patterns of glaucomatous optic disc damage. Design: Prospective longitudinal study. Participants: A total of 131 patients with open-angle glaucoma with focal (n = 45), diffuse (n = 42), and sclerotic (n = 44) optic disc damage. Methods: Patients were examined every 4 months with standard automated perimetry (SAP, SITA Standard, 24-2 test, Humphrey Field Analyzer, Carl Zeiss Meditec, Dublin, CA) and confocal scanning laser tomography (CSLT, Heidelberg Retina Tomograph, Heidelberg Engineering GmbH, Heidelberg, Germany) for a period of 4 years. During this time, patients were treated according to a predefined protocol to achieve a target intraocular pressure (IOP). Rates of change were estimated by robust linear regression of visual field mean deviation (MD) and global optic disc neuroretinal rim area with follow-up time. Main Outcome Measures: Rates of change in MD and rim area. Results: Rates of visual field change in patients with focal optic disc damage (mean -0.34, standard deviation [SD] 0.69 dB/year) were faster than in patients with sclerotic (mean - 0.14, SD 0.77 dB/year) and diffuse (mean + 0.01, SD 0.37 dB/year) optic disc damage (P = 0.003, Kruskal-Wallis). Rates of optic disc change in patients with focal optic disc damage (mean - 11.70, SD 25.5 x 10(-3) mm(2)/year) were faster than in patients with diffuse (mean -9.16, SD 14.9 x 10(-3) mm(2)/year) and sclerotic (mean -0.45, SD 20.6 x 10(-3) mm(2)/year) optic disc damage, although the differences were not statistically significant (P = 0.11). Absolute IOP reduction from untreated levels was similar among the groups (P = 0.59). Conclusions: Patients with focal optic disc damage had faster rates of visual field change and a tendency toward faster rates of optic disc deterioration when compared with patients with diffuse and sclerotic optic disc damage, despite similar IOP reductions during follow-up. Financial Disclosure(s): Proprietary or commercial disclosure may be found after the references. Ophthalmology 2012; 119: 294-303 (C) 2012 by the American Academy of Ophthalmology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Many epidemiologic studies suggest a number of risk factors that may be associated with progression of age-related maculopathy (ARM). In this study, the authors investigate ethnic differences in macular pigment density (MPD) and macular pigment (MP) distribution. METHODS: Inclusion criteria were healthy subjects, aged 35 to 49 years, visual acuity >or=20/20, race ethnicity white non-Hispanic (WNH) or African. All subjects underwent the following examinations: best-corrected ETDRS visual acuity (VA), measurements of MPD, and spatial distribution of MP with a modified confocal scanning laser ophthalmoscope according to a standard protocol. MPD maps were calculated from autofluorescence images recorded at 488 nm and 514 nm. Central macular pigment density (MPDc) was quantified from MPD maps within 0.5 degrees around the center of the fovea. RESULTS: In total, 118 healthy subjects (61 women, 57 men) aged 35 to 49 years (mean, 42.5 +/- 3.6 years) were recruited for the study. Sixty-seven healthy subjects were WNH and 51 were African. Visual acuity ranged from 20/20 to 20/16 in the study eye. Significant differences were found among MPDc between the group of WNH (MPDc, 0.36 +/- 0.13 density units [DU]; P < 0.0001) and African subjects (MPDc, 0.59 +/- 0.14 DU). A parafoveal ring was significantly more frequent in African subjects than in WNH subjects (86% [African] vs. 68% [WNH]; P < 0.0001). CONCLUSIONS: This study demonstrates that ethnicity plays a role in MPD values and in MP distribution. The association of different distribution patterns and their relevance as possible prognostic factors for diseases leading to oxidative retinal damage requires further studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Digital imaging methods are a centrepiece for diagnosis and management of macular disease. A recently developed imaging device is composed of simultaneous confocal scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). By means of clinical samples the benefit of this technique concerning diagnostic and therapeutic follow-up will be assessed. METHODS: The combined OCT-SLO-System (Ophthalmic Technologies Inc., Toronto, Canada) allows for confocal en-face fundus imaging and high resolution OCT scanning at the same time. OCT images are obtained from transversal line scans. One light source and the identical scanning rate yield a pixel-to-pixel correspondence of images. Three-dimensional thickness maps are derived from C-scan stacking. RESULTS: We followed-up patients with cystoid macular edema, pigment epithelium detachment, macular hole, venous branch occlusion, and vitreoretinal tractions during their course of therapy. The new imaging method illustrates the reduction of cystoid volume, e.g. after intravitreal injections of either angiostatic drugs or steroids. C-scans are used for appreciation of lesion diameters, visualisation of pathologies involving the vitreoretinal interface, and quantification of retinal thickness change. CONCLUSION: The combined OCT-SLO system creates both topographic and tomographic images of the retina. New therapeutic options can be followed-up closely by observing changes in lesion thickness and cyst volumes. For clinical use further studies are needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hoy en día las técnicas de adquisición de imágenes tridimensionales son comunes en diversas áreas, pero cabe destacar la relevancia que han adquirido en el ámbito de la imagen biomédica, dentro del cual encontramos una amplia gama de técnicas como la microscopía confocal, microscopía de dos fotones, microscopía de fluorescencia mediante lámina de luz, resonancia magnética nuclear, tomografía por emisión de positrones, tomografía de coherencia óptica, ecografía 3D y un largo etcétera. Un denominador común de todas esas aplicaciones es la constante necesidad por aumentar la resolución y la calidad de las imágenes adquiridas. En algunas de dichas técnicas de imagen tridimensional se da una interesante situación: aunque que cada volumen adquirido no contiene información suficiente para representar el objeto bajo estudio dentro de los parámetros de calidad requeridos por algunas aplicaciones finales, el esquema de adquisición permite la obtención de varios volúmenes que representan diferentes vistas de dicho objeto, de tal forma que cada una de las vistas proporciona información complementaria acerca del mismo. En este tipo de situación es posible, mediante la combinación de varias de esas vistas, obtener una mejor comprensión del objeto que a partir de cada una de ellas por separado. En el contexto de esta Tesis Doctoral se ha propuesto, desarrollado y validado una nueva metodología de proceso de imágenes basada en la transformada wavelet disc¬reta para la combinación, o fusión, de varias vistas con información complementaria de un mismo objeto. El método de fusión propuesto aprovecha la capacidad de descom¬posición en escalas y orientaciones de la transformada wavelet discreta para integrar en un solo volumen toda la información distribuida entre el conjunto de vistas adquiridas. El trabajo se centra en dos modalidades diferentes de imagen biomédica que per¬miten obtener tales adquisiciones multi-vista. La primera es una variante de la micro¬scopía de fluorescencia, la microscopía de fluorescencia mediante lámina de luz, que se utiliza para el estudio del desarrollo temprano de embriones vivos en diferentes modelos animales, como el pez cebra o el erizo de mar. La segunda modalidad es la resonancia magnética nuclear con realce tardío, que constituye una valiosa herramienta para evaluar la viabilidad del tejido miocárdico en pacientes con diversas miocardiopatías. Como parte de este trabajo, el método propuesto ha sido aplicado y validado en am¬bas modalidades de imagen. En el caso de la aplicación a microscopía de fluorescencia, los resultados de la fusión muestran un mejor contraste y nivel de detalle en comparación con cualquiera de las vistas individuales y el método no requiere de conocimiento previo acerca la función de dispersión puntual del sistema de imagen. Además, los resultados se han comparado con otros métodos existentes. Con respecto a la aplicación a imagen de resonancia magnética con realce tardío, los volúmenes fusionados resultantes pre-sentan una mejora cuantitativa en la nitidez de las estructuras relevantes y permiten una interpretación más sencilla y completa de la compleja estructura tridimensional del tejido miocárdico en pacientes con cardiopatía isquémica. Para ambas aplicaciones los resultados de esta tesis se encuentran actualmente en uso en los centros clínicos y de investigación con los que el autor ha colaborado durante este trabajo. Además se ha puesto a libre disposición de la comunidad científica la implementación del método de fusión propuesto. Por último, se ha tramitado también una solicitud de patente internacional que cubre el método de visualización desarrollado para la aplicación de Resonancia Magnética Nuclear. Abstract Nowadays three dimensional imaging techniques are common in several fields, but es-pecially in biomedical imaging, where we can find a wide range of techniques including: Laser Scanning Confocal Microscopy, Laser Scanning Two Photon Microscopy, Light Sheet Fluorescence Microscopy, Magnetic Resonance Imaging, Positron Emission To-mography, Optical Coherence Tomography, 3D Ultrasound Imaging, etc. A common denominator of all those applications being the constant need for further increasing resolution and quality of the acquired images. Interestingly, in some of the mentioned three-dimensional imaging techniques a remarkable situation arises: while a single volume does not contain enough information to represent the object being imaged within the quality parameters required by the final application, the acquisition scheme allows recording several volumes which represent different views of a given object, with each of the views providing complementary information. In this kind of situation one can get a better understanding of the object by combining several views instead of looking at each of them separately. Within such context, in this PhD Thesis we propose, develop and test new image processing methodologies based on the discrete wavelet transform for the combination, or fusion, of several views containing complementary information of a given object. The proposed fusion method exploits the scale and orientation decomposition capabil¬ities of the discrete wavelet transform to integrate in a single volume all the available information distributed among the set of acquired views. The work focuses in two different biomedical imaging modalities which provide such multi-view datasets. The first one is a particular fluorescence microscopy technique, Light-Sheet Fluorescence Microscopy, used for imaging and gaining understanding of the early development of live embryos from different animal models (like zebrafish or sea urchin). The second is Delayed Enhancement Magnetic Resonance Imaging, which is a valuable tool for assessing the viability of myocardial tissue on patients suffering from different cardiomyopathies. As part of this work, the proposed method was implemented and then validated on both imaging modalities. For the fluorescence microscopy application, the fusion results show improved contrast and detail discrimination when compared to any of the individual views and the method does not rely on prior knowledge of the system’s point spread function (PSF). Moreover, the results have shown improved performance with respect to previous PSF independent methods. With respect to its application to Delayed Enhancement Magnetic Resonance Imaging, the resulting fused volumes show a quantitative sharpness improvement and enable an easier and more complete interpretation of complex three-dimensional scar and heterogeneous tissue information in ischemic cardiomyopathy patients. In both applications, the results of this thesis are currently in use in the clinical and research centers with which the author collaborated during his work. An imple¬mentation of the fusion method has also been made freely available to the scientific community. Finally, an international patent application has been filed covering the visualization method developed for the Magnetic Resonance Imaging application.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo do estudo foi avaliar a influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de dois cimentos de ionômero de vidro (CIV) de alta viscosidade. Vinte terceiros molares foram alocados em 6 grupos experimentais, de acordo com a profundidade da dentina - proximal, oclusal superficial ou oclusal profunda, e os CIVs - Fuji IX (GC Corp.) e Ketac(TM) Molar Easy Mix (3M/ESPE). Inicialmente os dentes foram cortados a fim de se obter fatias de aproximadamente 1 mm de espessura de dentina proximal, oclusal superficial e profunda. Em seguida, foi realizado uma análise topográfica das secções das diferentes superfícies e profundidades em microscopia confocal a laser (100X) para obtenção das médias da densidade tubular em cada profundidade. Cânulas de polietileno foram então posicionadas sobre as secções de dentina pré-tratadas e preenchidas pelos CIVs. Os espécimes foram armazenados em água destilada por 24 h e 12 meses a 37°C, em seguida foram submetidos ao ensaio de microcisalhamento (0,5 mm/min). Após o ensaio, foi realizada a análise do padrão de fratura em estereomicroscópio (400X). Os dados obtidos foram submetidos à Análise de Variância para dados repetidos, seguido do teste de Tukey (?=5%). Verificamos que a densidade dos túbulos dentinários, em diferentes profundidades de molares permanentes, é inversamente proporcional a resistência de união de cimentos de ionômero de vidro de alta viscosidade. Foi ainda observado em todos os grupos que a resistência de união após 24 horas é maior do que em 12 meses, indicando degradação da interface adesiva ao longo do tempo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

La reconstruction en deux étapes par expanseur et implant est la technique la plus répandue pour la reconstruction mammmaire post mastectomie. La formation d’une capsule périprothétique est une réponse physiologique universelle à tout corps étranger présent dans le corps humain; par contre, la formation d’une capsule pathologique mène souvent à des complications et par conséquent à des résultats esthétiques sous-optimaux. Le microscope électronique à balayage (MEB) est un outil puissant qui permet d’effectuer une évaluation sans pareille de la topographie ultrastructurelle de spécimens. Le premier objectif de cette thèse est de comparer le MEB conventionnel (Hi-Vac) à une technologie plus récente, soit le MEB environnemental (ESEM), afin de déterminer si cette dernière mène à une évaluation supérieure des tissus capsulaires du sein. Le deuxième objectif est d‘appliquer la modalité de MEB supérieure et d’étudier les modifications ultrastructurelles des capsules périprothétiques chez les femmes subissant différents protocoles d’expansion de tissus dans le contexte de reconstruction mammaire prothétique. Deux études prospectives ont été réalisées afin de répondre à nos objectifs de recherche. Dix patientes ont été incluses dans la première, et 48 dans la seconde. La modalité Hi-Vac s’est avérée supérieure pour l’analyse compréhensive de tissus capsulaires mammaires. En employant le mode Hi-Vac dans notre protocole de recherche établi, un relief 3-D plus prononcé à été observé autour des expanseurs BIOCELL® dans le groupe d’approche d’intervention retardée (6 semaines). Des changements significatifs n’ont pas été observés au niveau des capsules SILTEX® dans les groupes d’approche d’intervention précoce (2 semaines) ni retardée.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A soil suspension was used as a source to initiate the development of microbial communities in flow cells irrigated with 2,4-dichlorophenoxyacetic acid (2,4-D) (25 mu g ml(-1)). Culturable bacterial members of the community were identified by 16S rRNA gene sequencing and found to be members of the genera Pseudomonas, Burkholderia, Collimonas and Rhodococcus. A 2,4-D degrading donor strain, Pseudomonas putida SM 1443 (pJP4::gfp), was inoculated into flow cell chambers containing 2-day old biofilm communities. Transfer of pJP4::gfp from the donor to the bacterial community was detectable as GFP fluorescing cells and images were captured using confocal scanning laser microscopy (GFP fluorescence was repressed in the donor due to the presence of a chromosomally located lacl(q) repressor gene). Approximately 5-10 transconjugant microcolonies, 20-40 mu m in diameter, could be seen to develop in each chamber. A 2,4-D degrading transconjugant strain was isolated from the flow cell system belonging to the genus Burkholderia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Loss of optic nerve head (ONH) axons in primary open angle glaucoma (POAG) has been attributed to both mechanical and vascular factors. Confocal scanning laser ophthalmoscopy (cSLO) provides a promising tool for the topographic follow-up of the ONH in glaucoma, while scanning laser Doppler flowmetry (SLDF) facilitates the rapid non-invasive assessment of retinal capillary blood flow. The purposes of these investigations were to optimise the techniques and explore their potential to classify and monitor disease. Preliminary investigations explored the reproducibility and validity of cSLO and SLDF and showed that: For cSLO: In a model eye, measurements are accurate over a range of axial lengths. For best reproducibility, seven images per visit are required, with a contour line located on Elschnig's scleral ring and transferred automatically between images. For SLDF: Three perfusion images are required for optimum reproducibility. Physiological changes induced by gas perturbation can be measured. Cross-sectional comparison of groups of normal subjects and early POAG patients showed that: cSLO parameters differentiate the early POAG group. Blood volume measured by SLDF showed group differences in superior nasal retina only. Longitudinal investigation of ONH topography, haemodynamic and visual field indices in normal subjects and POAG patients showed that: cSLO detects topographical change over time more frequently in the POAG group. Important parameters include: C:D area ratio, cup and rim area, mean depth in contour, volumes above and below reference and surface. Factor analysis identified "cup" and "rim" factors that can be used to detect change over time in individual patients. Blood flow changes were most apparent in the inferior nasal peripapillary retina of the POAG group. Perimetry is of clinical value for the identification of glaucoma but is less sensitive than cSLO for monitoring glaucomatous change.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this work is to measure the stress inside a hard micro object under extreme compression. To measure the internal stress, we compressed ruby spheres (a-Al2O3: Cr3+, 150 µm diameter) between two sapphire plates. Ruby fluorescence spectrum shifts to longer wavelengths under compression and can be related to the internal stress by a conversion coefficient. A confocal laser scanning microscope was used to excite and collect fluorescence at desired local spots inside the ruby sphere with spatial resolution of about 1 µm3. Under static external loads, the stress distribution within the center plane of the ruby sphere was measured directly for the first time. The result agreed to Hertz’s law. The stress across the contact area showed a hemispherical profile. The measured contact radius was in accord with the calculation by Hertz’s equation. Stress-load curves showed spike-like decrease after entering non-elastic phase, indicating the formation and coalescence of microcracks, which led to relaxing of stress. In the vicinity of the contact area luminescence spectra with multiple peaks were observed. This indicated the presence of domains of different stress, which were mechanically decoupled. Repeated loading cycles were applied to study the fatigue of ruby at the contact region. Progressive fatigue was observed when the load exceeded 1 N. As long as the load did not exceed 2 N stress-load curves were still continuous and could be described by Hertz’s law with a reduced Young’s modulus. Once the load exceeded 2 N, periodical spike-like decreases of the stress could be observed, implying a “memory effect” under repeated loading cycles. Vibration loading with higher frequencies was applied by a piezo. Redistributions of intensity on the fluorescence spectra were observed and it was attributed to the repopulation of the micro domains of different elasticity. Two stages of under vibration loading were suggested. In the first stage continuous damage carried on until certain limit, by which the second stage, e.g. breakage, followed in a discontinuous manner.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

This study focuses on the use of hemotoxylin-eosin staining plus fluorescence microscopy for the investigation of elastic fibers in some elastic cartilages. We have observed that elastic fibers are consistently imaged by the proposed procedure and the resolution attained is similar to that obtained with the classical Weigert's fuchsin-resorcin. The results also demonstrate that elastin autofluorescence gives little or no contribution to the final fluorescence and that the use of the confocal laser scanning microscope adds to the resolution, permits the use of thicker sections and reveals of minute structural features. We conclude that this is a relevant tool in elastin research.