870 resultados para Metal-ceramic joint. Mechanical metallization. Brazing. Zirconia and stainless steel


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this review is to illustrate how physical properties are important to food processing and quality. Three food products, flakes, porridge and bread, in addition to oat groats are used to show the influence of water and heat-treatments on the mechanical properties. The hydrothermal history of ingredients is shown to affect product quality. Water acts as a plasticiser and solvent in these foods, whilst heat modifies the conformation and interactions of macromolecular components. Structure as well as chemical composition is shown to govern texture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The compounds chlorothiazide and hydrochlorothiazide (crystalline form II) have been studied in their fully hydrogenous forms by powder neutron diffraction on the GEM diffractometer. The results of joint Rietveld refinement of the structures against multi-bank neutron and single-bank X-ray powder data are reported and show that accurate and precise structural information can be obtained from polycrystalline molecular organic materials by this route.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Obstacles considerably influence boundary layer processes. Their influences have been included in mesoscale models (MeM) for a long time. Methods used to parameterise obstacle effects in a MeM are summarised in this paper using results of the mesoscale model METRAS as examples. Besides the parameterisation of obstacle influences it is also possible to use a joint modelling approach to describe obstacle induced and mesoscale changes. Three different methods may be used for joint modelling approaches: The first method is a time-slice approach, where steady basic state profiles are used in an obstacle resolving microscale model (MiM, example model MITRAS) and diurnal cycles are derived by joining steady-state MITRAS results. The second joint modelling approach is one-way nesting, where the MeM results are used to initialise the MiM and to drive the boundary values of the MiM dependent on time. The third joint modelling approach is to apply multi-scale models or two-way nesting approaches, which include feedbacks from the MiM to the MeM. The advantages and disadvantages of the different approaches and remaining problems with joint Reynolds-averaged Navier–Stokes modelling approaches are summarised in the paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Much of the literature on the construction of mixed asset portfolios and the case for property as a risk diversifier rests on correlations measured over the whole of a given time series. Recent developments in finance, however, focuses on dependence in the tails of the distribution. Does property offer diversification from equity markets when it is most needed - when equity returns are poor. The paper uses an empirical copula approach to test tail dependence between property and equity for the UK and for a global portfolio. Results show strong tail dependence: in the UK, the dependence in the lower tail is stronger than in the upper tail, casting doubt on the defensive properties of real estate stocks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Os Nematoda e Protista podem ser transmitidos ao homem de diversas maneiras, mas pouca ênfase é dada para a transmissão mecânica por intermédio de formigas. Assim, esse trabalho procurou investigar a transmissão mecânica de ovos de Ascaris lumbricoides e cistos de Entamoeba coli pelos Formicidae. Através de experimentos com espécies mantidas em ninhos no laboratório (Tapinoma melanocephalum, Linepithema humile e Monomorium pharaonis) e com 17 espécies de formigas de uma área antropizada na região de Mogi as Cruzes (SP), foi possível constar que os ovos A. lumbricoides foram transportados por L. humile, tanto no campo (1 operária) como no laboratório (1 operária), por Camponotus rufipes (2), por Solenopsis saevissima (1) e por Acromyrmrex niger (1). em três operárias de C. rufipes foram encontrados cistos de E. coli. Apesar da baixa incidência de transporte, as três primeiras espécies pelo fato de viverem muito próximas ao ser humano, podem levar para dentro do ambiente domiciliar patógenos de Nematoda e Protista.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

47 end-stage TMJ patients with high occlusal plane angulation, treated with TMJ custom-fitted total joint prostheses and simultaneous maxillo-mandibular counter-clockwise rotation were evaluated for pain and dysfunction presurgery (T1) and at the longest follow-up (T2). Patients subjectively rated their facial pain/headache, TMJ pain, jaw function, diet and disability. Objective functional changes were determined by measuring maximum interincisal opening (MIO) and laterotrusive movements. Patients were divided according to the number of previous failed TMJ surgeries: Group 1 (0-1), Group 2 (2 or more). Significant subjective pain and dysfunction improvements (37-52%) were observed (<0.001). MIO increased 14% but lateral excursion decreased 60%. The groups presented similar absolute changes, but Group 2 showed more dysfunction at T1 and T2. For patients who did not receive fat grafts around the prostheses and had previous failure of proplast/teflon and or silastic TMJ implants, more than half required surgery for TMJ debridement and removal of foreign body giant cell reaction and heterotopic bone formation. End-stage TMJ patients can be treated in one operation with TMJ custom-made total joint prostheses and maxillo-mandibular counter-clockwise rotation, for correction of dentofacial deformity and improvement in pain and TMJ dysfunction; Group 1 patients had better results than Group 2 patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. To determine the influence of cement thickness and ceramic/cement bonding on stresses and failure of CAD/CAM crowns, using both multi-physics finite element analysis and monotonic testing.Methods. Axially symmetric FEA models were created for stress analysis of a stylized monolithic crown having resin cement thicknesses from 50 to 500 mu m under occlusal loading. Ceramic-cement interface was modeled as bonded or not-bonded (cement-dentin as bonded). Cement polymerization shrinkage was simulated as a thermal contraction. Loads necessary to reach stresses for radial cracking from the intaglio surface were calculated by FEA. Experimentally, feldspathic CAD/CAM crowns based on the FEA model were machined having different occlusal cementation spaces, etched and cemented to dentin analogs. Non-bonding of etched ceramic was achieved using a thin layer of poly(dimethylsiloxane). Crowns were loaded to failure at 5 N/s, with radial cracks detected acoustically.Results. Failure loads depended on the bonding condition and the cement thickness for both FEA and physical testing. Average fracture loads for bonded crowns were: 673.5 N at 50 mu m cement and 300.6 N at 500 mu m. FEA stresses due to polymerization shrinkage increased with the cement thickness overwhelming the protective effect of bonding, as was also seen experimentally. At 50 mu m cement thickness, bonded crowns withstood at least twice the load before failure than non-bonded crowns.Significance. Occlusal "fit" can have structural implications for CAD/CAM crowns; pre-cementation spaces around 50-100 mu m being recommended from this study. Bonding benefits were lost at thickness approaching 450-500 mu m due to polymerization shrinkage stresses. (C) 2012 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An improved on-site characterization of humic-rich hydrocolloids and their metal species in aquatic environments was the goal of the present approach. Both ligand exchange with extreme chelators ( diethylenetetraaminepentaacetic acid ( DTPA), ethylendiaminetetraacetic acid ( EDTA)) and metal exchange with strongly competitive cations (Cu(II)) were used on-site to characterize the conditional stability and availability of colloidal metal species in a humic-rich German bogwater lake ( Venner Moor, Munsterland). A mobile time-controlled tangential-flow ultrafiltration technique (cut-off: 1 kDa) was applied to differentiate operationally between colloidal metal species and free metal ions, respectively. DOC ( dissolved organic carbon) and metal determinations were carried out off-site using a home-built carbon analyzer and conventional ICP-OES ( inductively-coupled plasma-optical emission spectrometry), respectively. From the metal exchange equilibria obtained on-site the kinetic and thermodynamic stability of the original metal species ( Fe, Mn, Zn) could be characterized. Conditional exchange constants K ex obtained from aquatic metal species and competitive Cu(II) ions follow the order Mn > Zn >> Fe. Obviously, Mn and Zn bound to humic-rich hydrocolloids are very strongly competed by Cu( II) ions, in contrast to Fe which is scarcely exchangeable. The exchange of aquatic metal species (e.g. Fe) by DTPA/EDTA exhibited relatively slow kinetics but rather high metal availabilities, in contrast to their Cu(II) exchange.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thermal behaviour of polymetallic metal carbonyls containing Fe-Fe, Fe-Hg and Hg-Hg bonds and Lewis bases, such as [Fe-3(CO)(8)(L)(2)] (L = 1,10-phenantroline,2,2'-bipyridine), [Fe(CO)(4)(HgCl)(2)] and [Fe(CO)(4)(HgCl)(2)(L)(2)] (L = 1,10-phenantroline,2-quinolinethiol), have been investigated by thermal analysis (TG), Thermal studies give evidence that the thermal decomposition mechanisms and starting temperatures are strongly influenced by the Lewis bases. The thermal decompositions under synthetic air yielded, in all cases, the final solid product Fe2O3 which presence was confirmed by X-ray powder diffraction technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dental ceramics are presented within a simplifying framework allowing for facile understanding of their development, composition and indications. Engineering assessments of clinical function are dealt with and literature is reviewed on the clinical behaviour of all-ceramic systems. Practical aspects are presented regarding the choice and use of dental ceramics to maximize aesthetics and durability, emphasizing what we know and how we know it.