947 resultados para Metais - Fadiga


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study of a promising alternative for the treatment of produced water from the oil industry envisaging its reuse was the focus of this work. Millions of liters of water are generated per day, containing heavy metals in low concentrations (< 0,15 mg/L for Pb, <0,04 mg/L for Cd, <0,04 mg/L for Ni). The technology applied to extract these metals from aqueous phase was the solvent extraction and the extratants used were vegetable oils originated from coconut oil. They can be used in natural form or as derivatives, known as MAC - Mixture of Carboxílics Acids. The determination of the heavy metal con¬centrations in a complex matrix was made by using the atomic absorption spectrometry technique (AAS). On the bench tests using synthetics aqueous solutions containing metals, vegetable oils showed no power to extract the metals studied. The extractant MAC was selective for the Pb> Cd> Ni, in the concentration of 8% in the same organic phase. In this condition, the lower efficiency of extraction obtained was 92% for the Pb, 69% for the Cd, in the range of pH ranging from 6 to 8. An experimental planning was conducted for continuous tests. The device used was called MDIF Misturador-Decantador à Inversão de Fases and the aqueous phase was produced water from Pólo Indutrial de Guamaré/RN . No correlation between the studied variables (concentration of metal, concentration of extratant and agitation in the mixing chamer) could be obtained, because of possible factors which occurred as: variation in the composition of the studied sample, phenomena of precipitation and complexation of metals in the reservoir of feed, solubility of extratant

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accelerated growth of urban regions have produced relevant effects on water resources. Urban regions need an adequate institutional structure that can be able to face environmental demands and the adverse effects of land use on water resources. This study aims at analysing land use effects on heavy metals concentration in sediments and water, as well as making a comparative analysis involving water physical-chemical parameters. Applied methodology included both in loco water parameters measurement and water and bed sediment sampling at 8 sections along the fluvial system. Sample analysis was performed in laboratory in order to measure heavy metal concentrations. It was measured metal concentrations of Al, Cu, Pb, Cd, Fe, Ni and Zn. Once the samples were subjected to acid digestion (method 3050B), concentration values were measured by using atomic absorption spectrometry by flame (ICP-FLAA). The analysis results were compared with normative reference, these standards is intended to assess the risks of toxic substances in sediment and water management programs. The normative reference used in this work were: a) Ontario Ministry of the Environment and Energy (OMEE, 1993) b) Normative Netherlands (VROM, 2000); c) Normative Canadian (CCME, 1999); d) United States Environmental Protection Agency (USEPA, 1977), e) CONAMA Resolution No. 344/2004; f) CONAMA Resolution No. 357/2005. The high concentrations of iron (38,750 mg.g-1), Lead (1100 mg.g-1), Nickel (100 μg.g-1) and zinc (180 μg.g-1) detected sediments confirm the state of degradation of the aquatic system. Iron concentrations (1.08 mg.L-1), Aluminum (0.6 mg.L-1) and phosphorus (0.05 mg.L-1) present in the water are outside the established standards for human consumption

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Embora a análise no domínio da freqüência do sinal eletromiográfico (EMG) seja empregada na caracterização do processo de fadiga muscular localizada, sua aplicação, especificamente a da freqüência mediana (Fmed), é pouco explorada no âmbito esportivo. O objetivo do presente estudo foi verificar a viabilidade da aplicação do sinal EMG, através de sua análise no domínio da freqüência, como parâmetro para determinação e diferenciação no comportamento da fadiga muscular localizada. Dois grupos de sujeitos, um caracterizado como atletas (n =12) e outro como sedentários (n =12), foram submetidos a análises baseadas em procedimentos executados em três diferentes situações experimentais, todos envolvendo a modalidade de exercício isométrico: i) teste máximo para determinação da contração isométrica voluntária máxima (CIVM); ii) teste de fadiga, sustentado por 35 seg. a 80% da CIVM; iii) teste de recuperação, sustentado por 10 seg. a 80% da CIVM; neste ultimo foi monitorado o comportamento da Fmed nos três primeiros (Fmedi) e três últimos segundos (Fmedf) do sinal EMG no músculo tibial anterior durante o teste de fadiga. Durante os 10 segundos do teste de recuperação foi calculada a Fmed referente a todo o período (Fmedr). parâmetro utilizado no cálculo do índice de recuperação muscular (IRM). Os resultados apontam que a Fmedf apresentou valor menor em relação à Fmedi em ambos os grupos (p < 0,05). Quando comparado com o grupo de sedentários, o grupo de atletas apresentou valores maiores de Fmedi e Fmedf (p < 0,05). O valor médio e desvio-padrão do IRM para o grupo de atletas foram de 62,1% ± 28,7 e, para o grupo de sedentários, de 55,2% ± 27,8 (p > 0,05). Dessa forma, os resultados apresentados neste estudo permitem inferir a viabilidade na aplicação de parâmetros no domínio da freqüência do sinal EMG para a determinação e diferenciação do comportamento da fadiga muscular localizada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze the reproducibility of the electromyography signal's parameters (EMG) in the frequency domain used in the characterization of localized muscle fatigue. Fifteen male subjects underwent a fatigue test based on isometric knee extension, being held at three different times at intervals of seven days. To assess the reproducibility of data between the tests we calculated the correlation coefficient (ICC) for the median frequency (MF) in total exercise time (MFT), MF obtained for every 10% of exercise time (MF10%) and the powers of the frequency bands obtained by dividing the power spectrum at windows of 20 Hz. The results showed: (1) excellent reproducibility for MFT, (2) good reproducibility for MF10%, and (3) greater variation in the signal EMG bands from 20 to 120 Hz, especially at the bands of 20-40 Hz and 40-60 Hz, which showed greater sensitivity to the process of muscle fatigue. We conclude that the MF is a variable that shows good reproducibility and that the fragmented analysis of the power spectrum, by means of frequency bands, showed that significant variations occur in the EMG signal during the installation of the fatigue process, having potential to become a new method for the characterization of localized muscle fatigue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Muscle fatigue is a phenomenon that promotes physiological and biomechanical disorders and their changes in healthy subjects have been widely studied and have significant importance for care in preventing injuries, but we do not have many information about its effects in patients after ACL reconstruction. Thus, this study is to analyze the effects of fatigue on neuromuscular behavior of quadriceps after ACL reconstruction. To reach this objective, participants were forty men, twenty healthy (26,90 ± 6,29 years) and twenty after ACL reconstruction (29,75 ± 7,01 years) with a graft of semitendinosus and gracilis tendons, between four to six months after surgery. At first, there was an assessment of joint position sense (JPS) at the isokinetic dynamometer at a speed of 5°/s and target angle of 45° to analyze the absolute error of JPS. Next, we applied the a muscle fatigue protocol, running 100 repetitions of isokinetic knee flexion-extension at 90°/s. Concurrently with this protocol, there was the assessment of muscle performance, as the peak torque (PT) and fatigue index, and electromyographic activity (RMS and median frequency). Finally, we repeated the assessment of JPS. The statistical analysis showed that patients after ACL reconstruction have, even under normal conditions, the amended JPS compared with healthy subjects and that after fatigue, both have disturbances in the JPS, but this alteration is significantly exacerbated in patients after ACL reconstruction. About muscle performance, we could notice that these patients have a lower PT, although there are no differences between the dynamometric and EMG fatigue index. These findings show the necessity about the cares of pacients with ACL reconstruction in respect of the risks of articulate instability and overload in ligamentar graft

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the effect of different resting periods, after induced muscle fatigue, in the quadriceps femoris neuromuscular performance, in healthy subjects. Methods: Sixty-four volunteers, of both genders, with an average of 21,8 ± 1,7 years and mean body mass index of 24,2 ± 3,7 Kg/m2 were randomly assigned into 4 groups: control group (was not induced fatigue); Experimental Group 1 (Exp. 1 1 minute of rest after fatigue); Experimental Group 3 (Exp. 3 3 minutes of rest after fatigue) and Experimental Group 5 (Exp. 5 5 minutes of rest after fatigue). The subjects were evaluated to the knee´s joint position sense (JPS), followed by 5 flexion-extension knee concentric isokinetic contractions at 60°/s, with concomitant recording of median frequency (Fmed) of rectus femoris (RF), vastus lateralis (VL) and vastus medialis (VM). Then they underwent a muscle fatigue protocol (30 flexion-extension knee concentric contractions at 60°/s) and were reevaluated on the isokinetic performance, Fmed and JPS. Blood lactate levels were measured before initial assessment, immediately after the fatigue protocol and 5 minutes after the end of the rest period. Results: The adoption of 3 minutes of rest was sufficient to restore the initial conditions for the peak torque normalized by body weight and the VL and VM Fmed. The joint position sense returned to its initial values with 1 minute rest. The lactate concentration remained high regardless of the adopted rest period. Conclusion: The use of 3-minute rest period is sufficient for the reestablishment of the neuromuscular parameters to the pre fatigue values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to investigate the immediate effects of laser therapy on neuromuscular performance in healthy subjects after a muscle fatigue. This is a clinical trial, controlled, randomized, blinded, attended by 80 volunteers of both genders, healthy, with ages between 18 to 28 years. Initially the volunteers performed an initial evaluation (EV1) using electromyography in the biceps muscle, associated with assessment in isokinetic dynamometry with 5 concentric contractions (60 °/s) for elbow flexion. The subjects were randomly allocated into 4 groups: G1 (control, n = 20), G2 (placebo, n = 20), G3 (pre-fatigue laser, n = 20), and G4 (post fatigue laser, n = 20). The muscular fatigue protocol had 30 concentric isokinetic contractions (120 °/s). We used a 808 nm laser, power of 100 mW, applied at the belly of the biceps muscle. After the speeches the volunteers performed a final evaluation (EV2). Test was applied to two-way ANOVA with post hoc Turkey, with a significance level of 5%. There was no significant difference in electromyographic evaluation. In dynamometric evaluation showed a drop in peak torque, peak torque normalized to body weight (p <0.001) and average power (p <0, 05) between the initial and final evaluations in control. Among the groups there was a significant difference between the control and the other groups in relation to peak torque (p <0.05), peak torque to body weight (p <0.001) and average power (p <0.05). Therefore, the low intensity laser therapy does not alter the immediate neuromuscular performance after fatigue

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The term fatigability concerns the degree of fatigue associated with performing an activity of any type (physical, mental, emotional and / or social). Recently scales for assessing fatigue in the English language were created, however, gaps exist regarding the validity of these scales in relation to oxygen consumption and levels of perceived fatigue. Objective: To investigate the validity of perceived fatigability scale in older women frail and non-frail by the expired gases kinetics. Methods: This is a study of type validation, where were evaluated 48 elderly. The evaluation was conducted at two different sessions. In the first, data were collected demographic partners, as well as assessment of cognitive function, physical health, and the phenotype of frailty. The second was composed by the test 6-minute walk (6MWT) associated the expired gases kinects and assessment of perceived fatigability. Statistical analysis was performed a descriptive analysis and then we used the Pearson correlation test to evaluate the relationship between the measure of perceived fatigue and variables oxygen consumption (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (RER)before and after 6MWT. We used a linear regression model initially considering the following explanatory variable: age, Body Mass Index (BMI), presence of frailty, comorbidities, level of physical activity, distance covered in the 6MWT , the energy cost of walking and severity of fatigability on performance. Results: The final sample consisted of 44 elderly women, 4 elderly were excluded because they didn t complete all phases of this study. The mean age obtained was 75 years (± 7.2 years). There was no significant correlation between fatigability measures and the values of VO2 ( r = .09 , p = .56 ) , VCO2 ( r = .173 , p = .26 ) , RER ( r = - .121 , p = .43 ). The final linear regression model showed that the energy cost of walking, the usual level of physical activity and the performance severity of fatigability explained 83.5 % (R2 = 0.835, p < 0.01) of the variation in the perceived fatigability. Conclusion: Our findings indicate a relationship between greater severity of fatigability and lower levels of physical activity and increased energy cost in walking, suggesting that the fatigability analyses using a simple numeric scale is valid and viable for assessment of fatigue in older women

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As más condições laborais e a forma de organização do trabalho dentro do sistema capitalista frequentemente têm se mostrado nocivas para o trabalhador. Além disso, a chamada síndrome da fadiga crônica é um dos males que acomete a classe trabalhadora. Por meio de revisão teórica buscou-se caracterizar a síndrome, suas possíveis causas e consequências e o papel do psicólogo nas organizações. A fadiga pode ser compreendida como um esgotamento físico e mental, culminando em consequências para a saúde do trabalhador. Excesso de trabalho, pressão por produção, turnos alternados, riscos físicos e falta de autonomia são alguns fatores apontados como prováveis desencadeadores da síndrome, e as consequências encontradas vão desde baixo rendimento e maior risco de acidentes de trabalho até dificuldade para relaxar em momentos de lazer. É papel do psicólogo do trabalho e organizacional realizar ações remediadoras e preventivas que impeçam ou dificultem o aparecimento da fadiga no trabalho.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ligas de alumínio são extensamente usadas em partes aeronáuticas devido às boas propriedades mecânicas e baixa densidade. Estas partes devem ser unidas para formar conjuntos maiores. Uma junta estrutural é definida como um segmento de estrutura que provê um meio de transferir carga de um elemento estrutural para outro. A maioria das juntas aeronáuticas é mecanicamente fixada com múltiplos prendedores (parafusos ou rebites). Estas juntas apresentam uma alta concentração de tensões ao redor do prendedor, porque a transferência de carga entre elementos da junta acontece em uma fração da área disponível. Por outro lado, as cargas aplicadas em juntas adesivas são distribuídas sobre toda a área colada e reduz os pontos de concentração de tensão. Juntas são a fonte mais comum de falhas estruturais em aeronaves e quase todos os reparos envolvem juntas. Portanto, é importante entender todos os aspectos de projeto e análise de juntas. O objetivo deste trabalho é comparar estaticamente juntas estruturais de ligas de Al2024-T3 em três condições: juntas mecanicamente rebitadas, juntas coladas e uma configuração híbrida rebitada e colada. Foi usada a norma NASM 1312-4 para confecção dos corpos-de-prova. Além disso, foram conduzidos testes de fadiga, sob amplitude de carregamento constante e razão de tensão igual a 0,1 para avaliar a eficiência dos elementos estruturais durante sua vida em serviço. Os resultados mostraram que a configuração híbrida apresenta maior resistência estática e uma vida em fadiga superior à configuração colada.