973 resultados para Measurement Device


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Exhaled breath temperature (EBT) reflects airways (both eosinophilic and neutrophilic) inflammation in asthma and thus may aid the management of children with asthma that are treated with anti-inflammatory drugs. A new EBT monitor has become available that is cheap and easy to use and may be a suitable monitoring device for airways inflammation. Little is known about how EBT relates to asthma treatment decisions, disease control, lung function, or other non-invasive measures of airways inflammation, such as exhaled nitric oxide (ENO).

OBJECTIVE: To determine the relationships between EBT and asthma treatment decision, current control, pulmonary function, and ENO.

METHODS: Cross-sectional prospective study on 159 children aged 5-16 years attending a pediatric respiratory clinic. EBT was compared with the clinician's decision regarding treatment (decrease, no change, increase), asthma control assessment (controlled, partial, uncontrolled), level of current treatment (according to British Thoracic Society guideline, BTS step), ENO, and spirometry.

RESULTS: EBT measurement was feasible in the majority of children (25 of 159 could not perform the test) and correlated weakly with age (R = 0.33, P = <0.01). EBT did not differ significantly between the three clinician decision groups (P = 0.42), the three asthma control assessment groups (P = 0.9), or the current asthma treatment BTS step (P = 0.57).

CONCLUSIONS & CLINICAL IMPLICATIONS: EBT measurement was not related to measures of asthma control determined at the clinic. The routine intermittent monitoring of EBT in children prescribed inhaled corticosteroids who attend asthma clinics cannot be recommended for adjusting anti-inflammatory asthma therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Neutrophil elastase (NE) is a serine protease implicated in the pathogenesis of several respiratory diseases including cystic fibrosis (CF). The presence of free NE in BAL is a predictor of subsequent bronchiectasis in children with CF (Sly et al, 2013, NEJM 368: 1963-1970). Furthermore, children with higher levels of sputum NE activity (NEa) tend to experience a more rapid decline in FEV1 over time even after adjusting for age, gender and baseline FEV1 (Sagel et al, 2012, AJRCCM 186: 857-865). Its detection and quantification in biological samples is however confounded by a lack of robust methodologies. Standard assays using chromogenic or fluorogenic substrates are not specific when added to complex samples containing multiple proteolytic and hydrolytic enzymes. ELISA systems measure total protein levels which can be a mixture of latent, active and protease-inhibitor complexes. We have therefore developed a novel assay (ProteaseTag™ Active NE Immunoassay), which couples an activity dependent NE-Tag with a specific antibody step, resulting in an assay which is both selective and specific for NEa. Aims: To clinically validate ProteaseTag™ Active NE for the detection of free NEa in BAL from children with CF. Methods: A total of 95 paediatric BAL samples [CF (n=76; 44M, 32F) non-CF (n=19; 12M, 7F)] collected through the Study of Host Immunity and Early Lung Disease in CF (SHIELD CF) were analysed for NEa using ProteaseTag™ Active NE (ProAxsis Ltd) and a fluorogenic substrate-based assay utilising Suc-AAPV-AMC (Sigma). IL-8 was measured by ELISA (R&D Systems). Results were analysed to show comparisons in free NEa between CF and non-CF samples alongside correlations with a range of clinical parameters. Results: NEa measured by ProteaseTag™ Active NE correlated significantly with age (r=0.3, p=0.01) and highly significantly with both IL-8 (r=0.4, p=<0.0001) and the absolute neutrophil count (ANC) (r=0.4, p=<0.0001). These correlations were not observed when NEa was measured by the substrate assay even though a significant correlation was found between the two assays (r=0.8, p<0.0001). A trend towards significance was found between NEa in the CF and non-CF groups when measured by ProteaseTag™ Active NE (p=0.07). Highly significant differences were found with the other inflammatory parameters between the 2 groups (IL-8: p=0.0002 and ANC: p=0.006). Conclusion: NEa as a primary efficacy endpoint in clinical trials or as a marker of inflammation within the clinic has been hampered by the lack of a robust and simple to use assay. ProteaseTag™ Active NE has been shown to be a specific and superior tool in the measurement of NEa in paediatric CF BAL samples (supporting data from previous studies using adult CF expectorated samples). The technology is currently being transferred to a lateral flow device for use at Point of Care. Acknowledgements: This work was supported by the National Children’s Research Centre, Dublin (SHIELD CF) and grants from the Medical Research Council and Cystic Fibrosis Foundation Therapeutics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Affiliation: Pierre Dagenais : Hôpital Maisonneuve-Rosemont, Faculté de médecine, Université de Montréal

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ultrasonic is a good tool to investigate the elastic properties of crystals. It enables one to determine all the elastic constants, Poisson’s ratios, volume compressibility and bulk modulus of crystals from velocity measurements. It also enables one to demonstrate the anisotropy of elastic properties by plotting sections of the surfaces of phase velocity, slowness, group velocity, Young’s modulus and linear compressibility along the a-b, b-c and a-c planes. They also help one to understand more about phonon amplification and help to interpret various phenomena associated with ultrasonic wave propagation, thermal conductivity, phonon transport etc. Study of nonlinear optical crystals is very important from an application point of view. Hundreds of new NLO materials are synthesized to meet the requirements for various applications. Inorganic, organic and organometallic or semiorganic classes of compounds have been studied for several reasons. Semiorganic compounds have some advantages over their inorganic and inorganic counterparts with regard to their mechanical properties. High damage resistance, high melting point, good transparency and non-hygroscopy are some of the basic requirements for a material to be suitable for device fabrication. New NLO materials are being synthesized and investigation of the mechanical and elastic properties of these crystals is very important to test the suitability of these materials for technological applications

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At present, a fraction of 0.1 - 0.2% of the patients undergoing surgery become aware during the process. The situation is referred to as anesthesia awareness and is obviously very traumatic for the person experiencing it. The reason for its occurrence is mostly an insufficient dosage of the narcotic Propofol combined with the incapability of the technology monitoring the depth of the patient’s anesthetic state to notice the patient becoming aware. A solution can be a highly sensitive and selective real time monitoring device for Propofol based on optical absorption spectroscopy. Its working principle has been postulated by Prof. Dr. habil. H. Hillmer and formulated in DE10 2004 037 519 B4, filed on Aug 30th, 2004. It consists of the exploitation of Intra Cavity Absorption effects in a two mode laser system. In this Dissertation, a two mode external cavity semiconductor laser, which has been developed previously to this work is enhanced and optimized to a functional sensor. Enhancements include the implementation of variable couplers into the system and the implementation of a collimator arrangement into which samples can be introduced. A sample holder and cells are developed and characterized with a focus on compatibility with the measurement approach. Further optimization concerns the overall performance of the system: scattering sources are reduced by re-splicing all fiber-to-fiber connections, parasitic cavities are eliminated by suppressing the Fresnel reflexes of all one fiber ends by means of optical isolators and wavelength stability of the system is improved by the implementation of thermal insulation to the Fiber Bragg Gratings (FBG). The final laser sensor is characterized in detail thermally and optically. Two separate modes are obtained at 1542.0 and 1542.5 nm, tunable in a range of 1nm each. Mode Full Width at Half Maximum (FWHM) is 0.06nm and Signal to Noise Ratio (SNR) is as high as 55 dB. Independent of tuning the two modes of the system can always be equalized in intensity, which is important as the delicacy of the intensity equilibrium is one of the main sensitivity enhancing effects formulated in DE10 2004 037 519 B4. For the proof of concept (POC) measurements the target substance Propofol is diluted in the solvents Acetone and DiChloroMethane (DCM), which have been investigated for compatibility with Propofol beforehand. Eight measurement series (two solvents, two cell lengths and two different mode spacings) are taken, which draw a uniform picture: mode intensity ratio responds linearly to an increase of Propofol in all cases. The slope of the linear response indicates the sensitivity of the system. The eight series are split up into two groups: measurements taken in long cells and measurements taken in short cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This is mainly a discussant paper on measurement criteria upon sector’s investment and capitalservices and the way these composition and measurement issues come to have an impact ongrowth figures for some major sectors of the Colombian economy. The main focus is on distinctionmatters regarding the measurement of capital stock and capital services in the productionprocess. The availability of appropriate data, widely discussed throughout the document, impliesthat major affirmations are more hypothetic than indicative or descriptive in style. Moststatements are established as a motivation device for studies on sector’s activities with a focus onconsistency with aggregate figures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A flood warning system incorporates telemetered rainfall and flow/water level data measured at various locations in the catchment area. Real-time accurate data collection is required for this use, and sensor networks improve the system capabilities. However, existing sensor nodes struggle to satisfy the hydrological requirements in terms of autonomy, sensor hardware compatibility, reliability and long-range communication. We describe the design and development of a real-time measurement system for flood monitoring, and its deployment in a flash-flood prone 650 km2 semiarid watershed in Southern Spain. A developed low-power and long-range communication device, so-called DatalogV1, provides automatic data gathering and reliable transmission. DatalogV1 incorporates self-monitoring for adapting measurement schedules for consumption management and to capture events of interest. Two tests are used to assess the success of the development. The results show an autonomous and robust monitoring system for long-term collection of water level data in many sparse locations during flood events.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article we assess the abilities of a new electromagnetic (EM) system, the CMD Mini-Explorer, for prospecting of archaeological features in Ireland and the UK. The Mini-Explorer is an EM probe which is primarily aimed at the environmental/geological prospecting market for the detection of pipes and geology. It has long been evident from the use of other EM devices that such an instrument might be suitable for shallow soil studies and applicable for archaeological prospecting. Of particular interest for the archaeological surveyor is the fact that the Mini-Explorer simultaneously obtains both quadrature (‘conductivity’) and in-phase (relative to ‘magnetic susceptibility’) data from three depth levels. As the maximum depth range is probably about 1.5 m, a comprehensive analysis of the subsoil within that range is possible. As with all EM devices the measurements require no contact with the ground, thereby negating the problem of high contact resistance that often besets earth resistance data during dry spells. The use of the CMD Mini-Explorer at a number of sites has demonstrated that it has the potential to detect a range of archaeological features and produces high-quality data that are comparable in quality to those obtained from standard earth resistance and magnetometer techniques. In theory the ability to measure two phenomena at three depths suggests that this type of instrument could reduce the number of poor outcomes that are the result of single measurement surveys. The high success rate reported here in the identification of buried archaeology using a multi-depth device that responds to the two most commonly mapped geophysical phenomena has implications for evaluation style surveys. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract: A new methodology was created to measure the energy consumption and related green house gas (GHG) emissions of a computer operating system (OS) across different device platforms. The methodology involved the direct power measurement of devices under different activity states. In order to include all aspects of an OS, the methodology included measurements in various OS modes, whilst uniquely, also incorporating measurements when running an array of defined software activities, so as to include OS application management features. The methodology was demonstrated on a laptop and phone that could each run multiple OSs, results confirmed that OS can significantly impact the energy consumption of devices. In particular, the new versions of the Microsoft Windows OS were tested and highlighted significant differences between the OS versions on the same hardware. The developed methodology could enable a greater awareness of energy consumption, during both the software development and software marketing processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In many epidemiological studies it is common to resort to regression models relating incidence of a disease and its risk factors. The main goal of this paper is to consider inference on such models with error-prone observations and variances of the measurement errors changing across observations. We suppose that the observations follow a bivariate normal distribution and the measurement errors are normally distributed. Aggregate data allow the estimation of the error variances. Maximum likelihood estimates are computed numerically via the EM algorithm. Consistent estimation of the asymptotic variance of the maximum likelihood estimators is also discussed. Test statistics are proposed for testing hypotheses of interest. Further, we implement a simple graphical device that enables an assessment of the model`s goodness of fit. Results of simulations concerning the properties of the test statistics are reported. The approach is illustrated with data from the WHO MONICA Project on cardiovascular disease. Copyright (C) 2008 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An angle measuring device using a high performance and very compact accelerometer provides a new and exciting method for producing highly compact and accurate angle measuring devices. Accelerometers are micro-machined and are able to measure acceleration to a very high accuracy. By using gravity as a reference these compact devices can also be used for measuring angles of rotation. The inherent problem with these devices is that their response characteristic changes with temperature which is detrimental to measurement accuracy. This paper describes an effective method to overcome this problem using a temperature sensor and intelligent software to compensate for this drift characteristic. In order to demonstrate the effectiveness of this work, experiments have been developed and conducted with the results and analysis provided at the end
of this paper for discussion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automated laparoscopic instrument capable of non-invasive measurement of tip/tissue interaction forces for direct application in robotic assisted minimally invasive surgery systems_ is introduced in this paper. It has the capability to measure normal grasping forces as well as lateral interaction forces without any sensor mounted on the tip jaws. Further to non-invasive actuation of the tip, the proposed instrument is also able to change the grasping direction during surgical operation. Modular design of the instrument allows conversion between surgical modalities (e.g., grasping, cutting, and dissecting). The main focus of this paper is on evaluation of the grasping force capability of the proposed instrument. The mathematical formulation of fenestrated insert is presented and its non-linear behaviour is studied. In order to measure the stiffness of soft tissues, a device was developed that is also described in this paper. Tissue characterisation experiments were conducted and results are presented and analysed here. The experimental results verify the capability of the proposed instrument in accurately measuring grasping forces and in characterising artificial tissue samples of varying stiffness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

 This paper further the investigation of Doppler radar feasibility in measuring the flow in and out due to inhalation and exhalation under different conditions of breathing activities. Three different experiment conditions were designed to investigate the feasibility and consistency of Doppler radar which includes the combination of the states of normal breathing, deep breathing and apnoea state were demonstrated. The obtained Doppler radar signals were correlated and compared with the gold standard medical device, spirometer, yielding a good correlations between both devices. We also demonstrated the calibration of the Doppler radar signal can be performed in a simple manner in order to have a good agreements with the spirometer readings. The measurement of the flow in and out during the breathing activities can be measured accurately under different dynamics of breathing as long as the calibration is performed correctly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pressure analgesiometric device was developed for unrestrained cats. Eleven cats were studied. Stimulation was via three rounded pins within a bracelet on the forearm. The pins were advanced by manual bladder inflation. Bladder pressure was measured using a strain gauge pressure transducer. The threshold was recorded at the behavioural end point. Thresholds were measured at 5 and 15 min intervals for 2-4 h, after removal/replacement of the cuff, for 120 min after SC butorphanol (0.4 mg/kg), and with mild skin inflammation at the testing site. Data were analysed using ANOVA. Pressure thresholds in untreated cats were around 150 mmHg. The minimum interval for testing was established as 15 min. Data were reproducible over 4 h and beyond 24 h. Thresholds in 5 cats increased (P < 0.05) above baseline for 45 min after butorphanol with a maximum increase of 270 +/- 182 mmHg at 10 min. Thresholds decreased with inflammation. The method appears suitable for feline analgesia investigations. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work aims to demonstrate an application of telemetry for monitoring process variables. The authors developed the prototype of a dedicated device capable of multiplexing, encoding and transmitting real-time data signals via amplitude-shift keying modulation to remotely located device(s). The prototype development is described in details, enabling the reproduction of the proposed telemetry system for a three-phase motor as well as for other devices. Furthermore, the proposed device has an easy implementation by using of accessible components and low cost, also presenting a tutorial and educational purpose. © 2011 IEEE.