147 resultados para Mastigação
Resumo:
The experiment was conducted to evaluate the ingestive behavior of feedlot lambs fed with an exclusive diet of concentrate with different percentages of protein (14, 16, 18, and 20%). A total of twenty four Santa Inês crossbred lambs, not castrated, with approximately 180 days of age, average live weight of 25kg, confined, in a completely randomized design, with four treatments and six repetitions. The time spent on feeding decreased linearly in 0.20 hours/day for each 1% increasing in protein percentage in the diet, the idleness increased linearly in 0.25 hours/day, and the total chewing decreased linearly in 0.25 hours/day. The increase in the protein percentage in the diet increased the feed efficiency linearly (kg DM and NDF/hour) in 0.038 and 0.005kg/hour, respectively, for DM and NDF fractions. However, the intake of dry matter (DM) and neutral detergent fiber (NDF), the rumination efficiency (kg DM and NDF/hour), as well as the period (nº /day) and the time (min) spent on feeding, ruminating and idling were not influenced by different protein percentages in the diet.
Resumo:
Pós-graduação em Odontologia - FOAR
Resumo:
Pós-graduação em Reabilitação Oral - FOAR
Resumo:
Although one cannot prevent the birth of human beings with cleft palate lesions one can adopt attitudes and various procedures entirely viable to rehabilitate and recuperate these persons through a team work composed of the facilities of a hospital, physician, dentist, psychotherapist, epeech pathologist, pedagogue and a social worker. In order to reduce the suffering of these patients we took up this work to prove that even if not in an ideal manner nevertheleses in an acceptable one we can reintegrate these persons to their families, friends and social milieu, offering them more security in their social, psychic and human relationships. We have made a review of the literature during the last three decades where we found many possibilities of prosthetic recuperations which concerns esthetics, mastication and maxillomandibular relationships beyond allowing these pacients conditions to perform satisfactory the functions of deglution and speech. We have selected and executed 5 clinical cases out of 15 pacients formely choosen looking to different prosthetic plannings. We have also shown the major contribution that the osseous integrated implants can offer to the rehabilitation and recuperation of pacients whith congenitall labio palatal lesions. To simplify the understanding we tried to discuss the most varied types of prosthesis in well defined subjects having a separate approach for each of them and we still showed that the specificity of each case leads to a specific type of rehabilitation founded om esthetics, occlusion, osseous suport, edentulous space, and above all based in the common sense and Professional integrity
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Novos compósitos têm surgido no mercado especificamente destinados à confecção de restaurações estéticas posteriores. Entretanto, embora tais materiais apresentem resultados iniciais animadores, há a necessidade de comprovações adicionais para que possam ser utilizados com segurança. Resinas compostas posteriores são submetidas a estresses complexos de compressão e abrasão durante a mastigação e a aplicação de selantes superficiais tem sido relatada como forma de aumentar a resistência ao desgaste destes materiais. O presente trabalho teve como propósito avaliar a dureza e a resistência à compressão das resinas compostas Alert (Jeneric/Pentron), Ariston (Vivadent), Definite (Degussa), P60 (3M), Solitarie (Kulzer), Surefil (Dentsply) e Z100 (3M) após 90 dias de imersão em água destilada, recobertas com selante Protect It (Jeneric/Pentron) e submetidas à ciclagem mecânica (10.000 ciclos, 600N, 5Hz). Os ensaios de dureza (n=8) foram realizados em aparelho Wolpert, com diamante Vickers e peso de 50gf aplicado por 30 segundos, antes e após períodos de imersão de 30, 60 e 90 dias. Os ensaios de resistência à compressão (n=8) foram realizados somente após 90 dias, em corpos-de-prova cilíndricos medindo 8mm de altura por 4mm de diâmetro. Apenas os espécimes destinados à compressão foram ciclados mecanicamente. Os ensaios foram realizados em máquina MTS 810, equipada com célula de carga de 10kN (ciclagem) e 100kN (compressão) e velocidade de 0,5mm/min. Após análise de variância (p<0,05), os resultados mostraram, previamente à imersão, maiores valores de dureza para os materiais Z100 (74,253VHN) e Ariston (71,308VHN). A seguir, com valor semelhante à resina Ariston, mas inferior à resina Z100, apresentou-se o material Surefil (69,969VHN)...(Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
Legg-Calvé-Perthes disease is a non-inflammatory aseptic necrosis of the head of the femur that is found in both young animals and humans before the gap in the femur head closes. In the fields of both human and veterinary medicine the cause of this condition is not known for certain. Various factors have been put forward in the literature as being responsible for the incidence of this condition such as: abnormalities in coagulation, changes in blood flow in the arteries, a septic obstruction in the draining of the epiphysis or the upper parts of the femur, trauma, growth cycle, hyperactivity in a child, genetic influences and dietary factors. Case histories in dogs show that the first stages of the condition progress slowly but that limping or putting weight on the limb worsens at 6 to 8 weeks. Some owners talk about a sharp onset in clinical lameness. Other clinical symptoms may include irritability, loss of appetite and knawing at the hair surrounding the affected hip. In the course of physical examination manipulating the hip joint will cause pain to the animal. The advanced stages of the disease may result in restricted amplitude of movement, muscular atrophy and fracturing. In humans the clinical signs are similar, although progression of the disease is slower so that it can be diagnosed at an earlier stage. In veterinary medicine the diagnosis is, in the main, based on case history, clinical symptoms, physical examination and certain related procedures such as radiography. The various diagnoses include physical trauma and dislocation of the medial patella. In human medicine many people have been correctly diagnosed. Whatsmore, there is a range of related procedures that are virtually not available to veterinary medicine such as magnetic nuclear resonance, that show up necroses with great clarity before radiography and cintilography do, and is considered... (Complete abstract click electronic access below)
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Schwartz-Jampel syndrome (SJS) is a rare recessive disorder characterized mainly by myotonia. As the clinical signs and symptoms are manifested in the oromaxillofacial region, paediatric dentists may be first choice of parents that seek information and assistance to their children. A female patient diagnosed with SJS was brought to our clinic for dental treatment with main complain of difficulty on oral hygiene and mastication due to tooth crowding. The treatment included preventive measures, extraction of a supernumerary tooth and the maxillary primary second molars. Furthermore, the patient was referred to orthodontic treatment for correction of tooth crowding. When dealing with children with confirmed diagnosis of SSJ, paediatric dentists should be understand the need of planning the dental treatment considering the characteristics and possible complications associated with the syndrome in order to reduce the risks to patients, especially when surgical procedures are necessary.
Resumo:
O tratamento ortodôntico de pacientes periodontalmente comprometidos requer abordagem interdisciplinar que envolva diferentes especialidades odontológicas para que sejam obtidos resultados estéticos e funcionais satisfatórios. Normalmente, pacientes adultos com problemas periodontais apresentam migração dentária, erupção patológica e diastemas. Essas alterações de posição, geralmente, são o resultado da falta de equilíbrio entre o suporte periodontal e as forças oclusais que estão atuando nos dentes durante a mastigação e movimentos funcionais.
Resumo:
The objective of this study was to evaluate the impact of replacing conventional mandibular complete dentures by complete fixed dentures on the oral health-related quality of life and kinesiographic parameters of maxillary edentulous patients. Material and Methods: edentulous patients (n = 16) received one set of new complete dentures and after the intraoral adjustments and adaptation period (30 days), the Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (Ohip-Edent) was used to evaluate the oral health-related quality of life (OHQOL) of the participants. Additionally, the kinesiograph instrument K6-I (Myotronics Research Inc., Seattle, WA) was used to record opening and closure range of movement, mandibular movement, and the pattern of maxillary complete denture movement on chewing. Afterwards, the patients had their mandibular complete dentures replaced by a complete fixed denture and the same evaluation protocol was performed after 3 and 6 months. Ohip-Edent responses were analyzed using Wilcoxon's test for repeated measures (α = .05) and Kinesiographic data using the Student´s t test (α = .05). Results: The Ohip-Edent showed an improvement of general oral health-related quality of life after 3 and 6 months of the treatment with complete fixed dentures. Kinesiographic recordings revealed a significant increase on maximum mandibular movements of vertical opening and no differences for the movement of the maxillary complete denture on chewing after treatment with complete fixed dentures was observed. Conclusion: the installation of complete fixed dentures improved the OHQOL and changed mandibular movements, with increases in vertical amplitude of maximal opening.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)