986 resultados para Maintenance Energy
Resumo:
The castor bean crop (Ricinus communis L.) has acquired prestige due to industries interest in the oil quality and recently for new sources of energy demand. The experiment that served as basis for the data used in this study was conducted at the Lageado Experimental Farm, in Botucatu - SP, 2008. This study aimed to avaluate the crop viability through energy balance and energy efficiency since the implantation until biodiesel production using parameters of consumption in operational management for installation and maintenance of culture harvest and oil production. The soil management operations, sow and harvest consumed the total of 266.20 MJ ha(-1), gathering with the fertilizers, pesticides, fuels, lubricants, labor, seed and industrial processing totaled 56,808 MJ ha(-1) of energy inputs. The energy production was 72,814.00 MJ ha(-1). The industry still lacks studies thal would contribution data collection and more specific energy coefficients. The castor beans cultivation was considered efficient allowing again of 15983.44 MJ ha(-1) equivalent to about 415 liters of diesel oil.
Resumo:
Three trials were carried out to determine energy metabolized (EM) requirement model for starting and growing pullets from different strains, at five ambient temperatures and different percentage feather coverage. In Trial I, metabolizable energy requirements for maintenance (MEm) and efficiency of energy utilization were estimated using 64 birds of two different strains, Hy-Line W36 (HLW36) and Hy-Line Semi-heavy (HLSH), from 9 to 13 weeks of age. The effects of ambient temperature (12, 18, 24, 30 and 36ºC) and percentage feather coverage (0, 50 and 100%) on MEm were assessed in the second trial, using 48 birds per temperature per strain (HLSH and HLW36) from 9 to 13 weeks of age. Trial III evaluated ME requirements for weight gain (MEg) using 1,200 birds from two light strains (HLW36 and Hisex Light, HL) and two semi-heavy strains (HLSH and Hisex Semi-heavy, HSH) reared until 18 weeks of age. According to the prediction models, MEm changed as a function of temperature and feather coverage, whereas MEg changed as a function of age and bird strain. Thus, two models were developed for birds aged 1 to 6 weeks, one model for the light strain and one for the semi-heavy strain. Energy requirements (ER) were different among strains from 7 to 12 weeks, and therefore 4 models were elaborated. From 13 to 18 weeks, one single model was produced for semi-heavy birds, since ER between semi-heavy strains were not different, whereas two different models were elaborated for the light layers. MEg of light birds was higher than MEg of semi-heavy birds, independent of age.
Resumo:
In order to determine the net energy, protein and macrominerals requirements of 70 to 120 day old, 52 female White New Zealand rabbits, weighing 1900g +/- 40g were used. At the beginning of the experimental period, 14 of the 52 young does were slaughtered and the 38 remaining animals were kept under two dietary management: ad libitum and restricted feeding. Slaughters were performed to determine each nutrient body content. The weight gain nutrient requirements depicted by the quantities of each nutrient stored into the body were obtained by applying the regression equation, which estimate the empty body nutrient content logarithm as a function of the empty body weight logarithm, as described by ARC (1980). By determining the heat production logarithm at the zero level of metabolizable energy intake, the maintenance net energy requirement was estimated to be 45.31 Kcal/day/Kg(0.75) the mean net energy. protein, calcium, phosphorous, sodium, magnesium and potassium requirements for each gram of weight gain per day were estimated to be, 2.51 Kcal, 0.21g, 0.02g, 0.005g, 0.001g, 0.0004g and 0.002g, respectively.
Resumo:
The objective of this study was to determine models for ME requirements for broiler breeder pullets using the factorial method. The influence of the temperature on maintenance ME requirements was determined by experiments conducted in three environmental rooms with temperature kept constant at 15, 22, and 30°C, using the comparative slaughter technique. The energy requirements for weight gain were determined based on the body energy content and efficiency of energy utilization for weight gain. Two ME requirement models for each age were developed using the coefficients for maintenance and weight gain. The models for 3 to 8 wk were ME = W 0.75 (186.52 - 1.94T) + 2.47WG, and ME = W 0.75 (174 - 1.88T) + 2.83WG; for 9 to 14 wk, ME = W 0.75 (186.52 - 1.94T) + 2.69WG, and ME = W 0.75 (174 - 1.88T) + 2.50WG; and 15 to 20 wk, ME = W 0.75 (186.52 - 1.94T) + 2.76WG, and ME = W 0.75 (174 - 1.88T) + 3.24WG. In these equations, W is BW (kg), T is temperature (°C), and WG is daily weight gain (g). These models were compared to the breeder's recommendations in a feeding trial from 5 to 20 wk of age. Models 1 and 2 provided energy intakes that promoted BW smaller than the breeder's recommendation. However, all breeder pullets had weights above the standard recommendation. Model 2 gave the smallest ME intake and BW close to the standard recommendation and provided the best prediction of ME requirements.
Resumo:
Incluye Bibliografía
Resumo:
The cost of maintenance makes up a large part of total energy costs in ruminants. Metabolizable energy (ME) requirement for maintenance (MEm) is the daily ME intake that exactly balances heat energy (HE). The net energy requirement for maintenance (NEm) is estimated subtracting MEm from the HE produced by the processing of the diet. Men cannot be directly measured experimentally and is estimated by measuring basal metabolism in fasted animals or by regression measuring the recovered energy in fed animals. MEm and NEm usually, but not always, are expressed in terms of BW0.75. However, this scaling factor is substantially empirical and its exponent is often inadequate, especially for growing animals. MEm estimated by different feeding systems (AFRC, CNCPS, CSIRO, INRA, NRC) were compared by using dairy cattle data. The comparison showed that these systems differ in the approaches used to estimate MEm and for its quantification. The CSIRO system estimated the highest MEm, mostly because it includes a correction factor to increase ME as the feeding level increases. Relative to CSIRO estimates, those of NRC, INRA, CNCPS, and AFRC were on average 0.92, 0.86, 0.84, and 0.78, respectively. MEm is affected by the previous nutritional history of the animals. This phenomenon is best predicted by dynamic models, of which several have been published in the last decades. They are based either on energy flows or on nutrient flows. Some of the different approaches used were described and discussed.
Resumo:
The present study suggests the use of high energy ball milling to mix (to dope) the phase MgB2 with the AlB2 crystalline structure compound, ZrB2, with the same C32 hexagonal structure than MgB 2, in different concentrations, enabling the maintenance of the crystalline phase structures practically unaffected and the efficient mixture with the dopant. The high energy ball milling was performed with different ball-to-powder ratios. The analysis of the transformation and formation of phases was accomplished by X-ray diffractometry (XRD), using the Rietveld method, and scanning electron microscopy. As the high energy ball milling reduced the crystallinity of the milled compounds, also reducing the size of the particles, the XRD analysis were influenced, and they could be used as comparative and control method of the milling. Aiming the recovery of crystallinity, homogenization and final phase formation, heat treatments were performed, enabling that crystalline phases, changed during milling, could be obtained again in the final product. © (2010) Trans Tech Publications.
Specialist tool for monitoring the measurement degradation process of induction active energy meters
Resumo:
This paper presents a methodology and a specialist tool for failure probability analysis of induction type watt-hour meters, considering the main variables related to their measurement degradation processes. The database of the metering park of a distribution company, named Elektro Electricity and Services Co., was used for determining the most relevant variables and to feed the data in the software. The modeling developed to calculate the watt-hour meters probability of failure was implemented in a tool through a user friendly platform, written in Delphi language. Among the main features of this tool are: analysis of probability of failure by risk range; geographical localization of the meters in the metering park, and automatic sampling of induction type watt-hour meters, based on a risk classification expert system, in order to obtain information to aid the management of these meters. The main goals of the specialist tool are following and managing the measurement degradation, maintenance and replacement processes for induction watt-hour meters. © 2011 IEEE.
Resumo:
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE.
Resumo:
The traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc-flash hazard is a particularly new phenomenon, and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be simply increased by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as nonstandard practices and installations are also partly responsible. The aim of this article is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc-flash interruption performance of various manufacturers. The purpose of this article is to obtain a more objective indication of the influence of different fuse link manufacturers on arc-flash incident energy. © 1975-2012 IEEE.
Resumo:
Models of daily energy requirement can help to establish better and more profitable feeding programs for poultry. Studies have been conducted at UNESP-Jaboticabal-Brazil with the aim of studying energy utilization in broiler breeders, laying hens, and broilers, and to establish metabolisable energy requirement models. The factorial approach was used to partition the energy requirements into maintenance, growth, and production components. The resulting models consider body weight, weight gain, egg production, and environmental temperature for the determination of the energy requirements of poultry. These models were evaluated in performance trials and provided good estimates. Therefore, they can be used to establish nutritional programs. The aim of this chapter is to describe the development of these models and to outline the results of our studies at UNESP.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Zootecnia - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)