891 resultados para MICROEMULSION ELECTROKINETIC CHROMATOGRAPHY
Resumo:
Cattle grazing in arid rangelands of Australia suffer periodic extensive and serious poisoning by the plant species Pimelea trichostachya, P. simplex, and P. elongata. Pimelea poisoning (also known as St. George disease and Marree disease) has been attributed to the presence of the diterpenoid orthoester simplexin in these species. However, literature relating to previous studies is complicated by taxonomic revisions, and the presence of simplexin has not previously been verified in all currently recognized taxa capable of inducing pimelea poisoning syndrome, with no previous chemical studies of P. trichostachya (as currently classified) or P. simplex subsp. continua. We report here the isolation of simplexin from P. trichostachya and the development of a liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) method to measure simplexin concentrations in pimelea plant material. Simplexin was quantified by positive-ion atmospheric pressure chemical ionization (APCI) LC-MS/MS with selected reaction monitoring (SRM) of the m/z 533.3 > 253.3 transition. LC-MS/MS analysis of the four poisonous taxa P. trichostachya, P. elongata, P. simplex subsp. continua, and P. simplex subsp. simplex showed similar profiles with simplexin as the major diterpenoid ester component in all four taxa accompanied by varying amounts of related orthoesters. Similar analyses of P. decora, P. haematostachya, and P. microcephala also demonstrated the presence of simplexin in these species but at far lower concentrations, consistent with the limited reports of stock poisoning associated with these species. The less common, shrubby species P. penicillaris contained simplexin at up to 55 mg/kg dry weight and would be expected to cause poisoning if animals consumed sufficient plant material.
Resumo:
Abstract is not available.
Resumo:
Isopentenyl adenosine antibodies useful in the investigations of the "cytokinin" functions of isopentenyl adenosine were purified by affinity chromatography. Using different affinity columns, the antibodies were purified to near complete purity. Analyses of the purified proteins revealed the presence of isopentenyl adenosine binding proteins in normal rabbit serum, which presence supports a suggested role for isopentenyl adenosine and its related compounds in animal cell division in vivo.
Resumo:
A procedure has been developed for the isolation of very low density lipoproteins from hen's egg yolk plasma using DEAE-cellulose chromatography. This procedure is rapid and does not require ultracentrifugation and should, therefore, serve as a useful procedure for use in laboratories where this facility does not exist.
Resumo:
Fluorinated surfactant-based aqueous film-forming foams (AFFFs) are made up of per- and polyfluorinated alkyl substances (PFAS) and are used to extinguish fires involving highly flammable liquids. The use of perfluorooctanesulfonic acid (PFOS) and other perfluoroalkyl acids (PFAAs) in some AFFF formulations has been linked to substantial environmental contamination. Recent studies have identified a large number of novel and infrequently reported fluorinated surfactants in different AFFF formulations. In this study, a strategy based on a case-control approach using quadrupole time-of-flight tandem mass spectrometry (QTOF-MS/MS) and advanced statistical methods has been used to extract and identify known and unknown PFAS in human serum associated with AFFF-exposed firefighters. Two target sulfonic acids [PFOS and perfluorohexanesulfonic acid (PFHxS)], three non-target acids [perfluoropentanesulfonic acid (PFPeS), perfluoroheptanesulfonic acid (PFHpS), and perfluorononanesulfonic acid (PFNS)], and four unknown sulfonic acids (Cl-PFOS, ketone-PFOS, ether-PFHxS, and Cl-PFHxS) were exclusively or significantly more frequently detected at higher levels in firefighters compared to controls. The application of this strategy has allowed for identification of previously unreported fluorinated chemicals in a timely and cost-efficient way.
Resumo:
Comprehensive two-dimensional gas chromatography (GC×GC) offers enhanced separation efficiency, reliability in qualitative and quantitative analysis, capability to detect low quantities, and information on the whole sample and its components. These features are essential in the analysis of complex samples, in which the number of compounds may be large or the analytes of interest are present at trace level. This study involved the development of instrumentation, data analysis programs and methodologies for GC×GC and their application in studies on qualitative and quantitative aspects of GC×GC analysis. Environmental samples were used as model samples. Instrumental development comprised the construction of three versions of a semi-rotating cryogenic modulator in which modulation was based on two-step cryogenic trapping with continuously flowing carbon dioxide as coolant. Two-step trapping was achieved by rotating the nozzle spraying the carbon dioxide with a motor. The fastest rotation and highest modulation frequency were achieved with a permanent magnetic motor, and modulation was most accurate when the motor was controlled with a microcontroller containing a quartz crystal. Heated wire resistors were unnecessary for the desorption step when liquid carbon dioxide was used as coolant. With use of the modulators developed in this study, the narrowest peaks were 75 ms at base. Three data analysis programs were developed allowing basic, comparison and identification operations. Basic operations enabled the visualisation of two-dimensional plots and the determination of retention times, peak heights and volumes. The overlaying feature in the comparison program allowed easy comparison of 2D plots. An automated identification procedure based on mass spectra and retention parameters allowed the qualitative analysis of data obtained by GC×GC and time-of-flight mass spectrometry. In the methodological development, sample preparation (extraction and clean-up) and GC×GC methods were developed for the analysis of atmospheric aerosol and sediment samples. Dynamic sonication assisted extraction was well suited for atmospheric aerosols collected on a filter. A clean-up procedure utilising normal phase liquid chromatography with ultra violet detection worked well in the removal of aliphatic hydrocarbons from a sediment extract. GC×GC with flame ionisation detection or quadrupole mass spectrometry provided good reliability in the qualitative analysis of target analytes. However, GC×GC with time-of-flight mass spectrometry was needed in the analysis of unknowns. The automated identification procedure that was developed was efficient in the analysis of large data files, but manual search and analyst knowledge are invaluable as well. Quantitative analysis was examined in terms of calibration procedures and the effect of matrix compounds on GC×GC separation. In addition to calibration in GC×GC with summed peak areas or peak volumes, simplified area calibration based on normal GC signal can be used to quantify compounds in samples analysed by GC×GC so long as certain qualitative and quantitative prerequisites are met. In a study of the effect of matrix compounds on GC×GC separation, it was shown that quality of the separation of PAHs is not significantly disturbed by the amount of matrix and quantitativeness suffers only slightly in the presence of matrix and when the amount of target compounds is low. The benefits of GC×GC in the analysis of complex samples easily overcome some minor drawbacks of the technique. The developed instrumentation and methodologies performed well for environmental samples, but they could also be applied for other complex samples.
Resumo:
Abstract is not available.
Resumo:
Porous titanium dioxide synthesized with a bicontinuous surfactant template is a promising method that leads to a high active surface area electrode. The template used is based on a water/isooctane/dioctyl sodium sulfosuccinate salt together with lecithin. Several parameters were varied during the synthesis to understand and optimize channel formation mechanisms. The material is patterned in stacked conical channels, widening towards the centre of the grains. The active surface area increased by 116% when the concentration of alkoxide precursors was decreased and increased by 241% when the template formation temperature was decreased to 10C. Increasing the oil phase viscosity tends to widen the pore aperture, thus decreasing the overall active surface area. Changing the phase proportions alters the microemulsion integrity and disrupts channel formation.
Resumo:
In this paper, the effect of rhamnolipid biosurfactant on the electrokinetic and rheological behavior of nanozirconia particles is reported. The effect of pH, concentration of biosurfactant, and solids loading on ζ-potential and rheological behavior was investigated. ζ-potential measurements showed that adsorption of biosurfactant shifted the iso-electric point of zirconia with increasing biosurfactant concentration. The surface of zirconia became more electronegative in the presence of biosurfactant indicating a strong interaction. Maximum charge was obtained in the presence of about 230 ppm of biosurfactant. Rheological tests at pH 7 revealed that the zirconia suspension is viscous at high solids loading and addition of biosurfactant decreased the viscosity substantially especially at high solids loading (>50 wt%). Sedimentation tests confirmed that the biosurfactant is a good dispersant for zirconia particles at pH values of 7 and above.
Resumo:
α-Manganese dioxide is synthesized in a microemulsion medium by a redox reaction between KMnO4 and MnSO4 in presence of sodium dodecyl sulphate as a surface active agent. The morphology of MnO2 resembles nanopetals, which are spread parallel to the field. The material is further characterized by powder X-ray diffraction, energy dispersive analysis of X-ray, and Brunauer–Emmett–Teller surface area. Supercapacitance property of α-MnO2 nanopetals is studied by cyclic voltammetry and galvanostatic charge–discharge cycling. High values of specific capacitance are obtained.
Resumo:
A simple and rapid method for the separation of vitamins A1 and A2 and allied compounds by thin-layer chromatography using kieselgel has been described. The method, however, cannot bbe applied for quantitative estimation.