1000 resultados para Méthode de quantification
Resumo:
In this study, an attempt was made in order to measure and evaluate the eco-efficiency performance of a pultruded composite processing company. For this purpose the recommendations of World Business Council for Sustainable Development (WCSD) and the directives of ISO 14301 standard were followed and applied. The main general indicators of eco-efficiency, as well as the specific indicators, were defined and determined. With basis on indicators’ figures, the value profile, the environmental profile, and the pertinent ecoefficiency’s ratios were established and analyzed. In order to evaluate potential improvements on company eco-performance, new indicators values and eco-efficiency ratios were estimated taking into account the implementation of new proceedings and procedures, both in upstream and downstream of the production process, namely: a) Adoption of new heating system for pultrusion die in the manufacturing process, more effective and with minor heat losses; c) Recycling approach, with partial waste reuse of scrap material derived from manufacturing, cutting and assembly processes of GFRP profiles. These features lead to significant improvements on the sequent assessed eco-efficiency ratios of the present case study, yielding to a more sustainable product and manufacturing process of pultruded GFRP profiles.
Resumo:
This work describes the development of an electrochemical enzymatic biosensor for quantification of the pesticide formetanate hydrochloride (FMT). It is based on a gold electrode modified with electrodeposited gold nanoparticles and laccase. The principle behind its development relies on FMT's capacity to inhibit the laccase catalytic reaction that occurs in the presence of phenolic substrates. The optimum values for the relevant experimental variables such as gold nanoparticles electrochemical deposition (at − 0.2 V for 100 s), laccase immobilization (via glutaraldehyde cross-linking), laccase concentration (12.4 mg/mL), substrate selection and concentration (5.83×10−5 M of aminophenol), pH (5.0), buffer (Britton–Robinson), and square-wave voltammetric parameters were determined. The developed biosensor was successfully applied to FMT determination in mango and grapes. The attained limit of detection was 9.5×10−8 ± 9.5×10−10 M (0.02 ± 2.6×10−4 mg/kg on a fresh fruit weight basis). Recoveries for the five tested spiking levels ranged from 95.5 ± 2.9 (grapes) to 108.6 ± 2.5% (mango). The results indicated that the proposed device presents suitable characteristics in terms of sensitivity (20.58 ± 0.49 A/μM), linearity (9.43×10−7 to 1.13×10−5 M), accuracy, repeatability (RSD of 1.4%), reproducibility (RSD of 1.8%) and stability (19 days) for testing of compliance with established maximum residue limits of FMT in fruits and vegetables.
Resumo:
Dissertation presented to obtain the degree of Doctor of Philosophy in Electrical Engineering, speciality on Perceptional Systems, by the Universidade Nova de Lisboa, Faculty of Sciences and Technology
Resumo:
Among the determinant factors in the resistance and susceptibility of Biomphalaria to Schistosoma mansoni, hemocytes play an important role. Aiming at studying S. mansoni/Biomphalaria interactions related to hemocytes, the first step is certainly connected with the standardization of this cell population in uninfected Biomphalaria. In this way, quantification of this cell population in hemolymph, as well as its phagocitary capacity, have been determined for the first time. Furthermore, using susceptible and resistant strains of B. glabrata and B. tenagophila, the hemocytegram and phagocytary capacity of hemocytes after infection with S. mansoni were determined too. Resistant and susceptible strains of B.glabrata (BA and BH, respectively), as well as resistant and susceptible strains of B. tenagophila (Taim and CF, respectively) were infected with 10 miracidia of the LE and SJ strains of S. mansoni, respectively. These infected snails and respective uninfected controls were assessed in relation to the number of circulating hemocytes and alteration in the phagocytary capacity, by using Zymozan and MTT. Reading was taken by means of a spectrophotometer at 5 hours and 1,2,5,10,20 and 30 days after infection. The results showed a decrease in population of the circulating phagocytary cells, 5 hours after infection. One day post-infection, the circulating cells of the susceptible snails showed an increased metabolic activity, but the same event could not be observed in the resistant strains. In the subsequent observation periods, significant differences among the strains studied could not be observed until the end of the experiment
Resumo:
Dissertation for the Degree of Master in Technology and Food Safety – Food Quality
Resumo:
This work aims to evaluate the feasibility of using image-based cytometry (IBC) in the analysis of algal cell quantification and viability, using Pseudokirchneriella subcapitata as a cell model. Cell concentration was determined by IBC to be in a linear range between 1 × 105 and 8 × 106 cells mL−1. Algal viability was defined on the basis that the intact membrane of viable cells excludes the SYTOX Green (SG) probe. The disruption of membrane integrity represents irreversible damage and consequently results in cell death. Using IBC, we were able to successfully discriminate between live (SG-negative cells) and dead algal cells (heat-treated at 65 °C for 60 min; SG-positive cells). The observed viability of algal populations containing different proportions of killed cells was well correlated (R 2 = 0.994) with the theoretical viability. The validation of the use of this technology was carried out by exposing algal cells of P. subcapitata to a copper stress test for 96 h. IBC allowed us to follow the evolution of cell concentration and the viability of copper-exposed algal populations. This technology overcomes several main drawbacks usually associated with microscopy counting, such as labour-intensive experiments, tedious work and lack of the representativeness of the cell counting. In conclusion, IBC allowed a fast and automated determination of the total number of algal cells and allowed us to analyse viability. This technology can provide a useful tool for a wide variety of fields that utilise microalgae, such as the aquatic toxicology and biotechnology fields.
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Química e Bioquímica
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Mecânica
Resumo:
Dissertation for the Master Degree in Technology and Food Security
Resumo:
2015
Resumo:
INTRODUCTION: Occupational HIV infection among healthcare workers is an important issue in exposures involving blood and body fluids. There are few data in the literature regarding the potential and the duration of infectivity of HIV type 1 (HIV-1) in contaminated material under adverse conditions. METHODS: We quantified HIV-1 viral RNA in 25×8mm calibre hollow-bore needles, after punctures, in 25 HIV-1-infected patients selected during the sample collection. All of the patients selected were between the ages of 18 and 55. Five samples were collected from 16 patients: one sample for the immediate quantification of HIV-1 RNA in the plasma and blood samples from the interior of 4 needles to be analyzed at 0h, 6h, 24h, and 72h after collection. In nine patients, another test was carried out in the blood from one additional needle, in which HIV-1 RNA was assessed 168h after blood collection. The method used to assess HIV-1 RNA was nucleic acid sequence-based amplification. RESULTS: Up to 7 days after collection, HIV-1 RNA was detected in all of the needles. The viral RNA remained stable up to 168h, and there were no statistically significant differences among the needle samples. CONCLUSIONS: Although the infectivity of the viral material in the needles is unknown, the data indicate the need to re-evaluate the practices in cases of occupational accidents in which the source is not identified.
Resumo:
Introduction Molecular biology procedures to detect, genotype and quantify hepatitis C virus (HCV) RNA in clinical samples have been extensively described. Routine commercial methods for each specific purpose (detection, quantification and genotyping) are also available, all of which are typically based on polymerase chain reaction (PCR) targeting the HCV 5′ untranslated region (5′UTR). This study was performed to develop and validate a complete serial laboratory assay that combines real-time nested reverse transcription-polymerase chain reaction (RT-PCR) and restriction fragment length polymorphism (RFLP) techniques for the complete molecular analysis of HCV (detection, genotyping and viral load) in clinical samples. Methods Published HCV sequences were compared to select specific primers, probe and restriction enzyme sites. An original real-time nested RT-PCR-RFLP assay was then developed and validated to detect, genotype and quantify HCV in plasma samples. Results The real-time nested RT-PCR data were linear and reproducible for HCV analysis in clinical samples. High correlations (> 0.97) were observed between samples with different viral loads and the corresponding read cycle (Ct - Cycle threshold), and this part of the assay had a wide dynamic range of analysis. Additionally, HCV genotypes 1, 2 and 3 were successfully distinguished using the RFLP method. Conclusions A complete serial molecular assay was developed and validated for HCV detection, quantification and genotyping.