939 resultados para Local anesthetics, Lipid membrane


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The highly hydrophobic fluorophore Laurdan (6-dodecanoyl-2-(dimethylaminonaphthalene)) has been widely used as a fluorescent probe to monitor lipid membranes. Actually, it monitors the structure and polarity of the bilayer surface, where its fluorescent moiety is supposed to reside. The present paper discusses the high sensitivity of Laurdan fluorescence through the decomposition of its emission spectrum into two Gaussian bands, which correspond to emissions from two different excited states, one more solvent relaxed than the other. It will be shown that the analysis of the area fraction of each band is more sensitive to bilayer structural changes than the largely used parameter called Generalized Polarization, possibly because the latter does not completely separate the fluorescence emission from the two different excited states of Laurdan. Moreover, it will be shown that this decomposition should be done with the spectrum as a function of energy, and not wavelength. Due to the presence of the two emission bands in Laurdan spectrum, fluorescence anisotropy should be measured around 480 nm, to be able to monitor the fluorescence emission from one excited state only, the solvent relaxed state. Laurdan will be used to monitor the complex structure of the anionic phospholipid DMPG (dimyristoyl phosphatidylglycerol) at different ionic strengths, and the alterations caused on gel and fluid membranes due to the interaction of cationic peptides and cholesterol. Analyzing both the emission spectrum decomposition and anisotropy it was possible to distinguish between effects on the packing and on the hydration of the lipid membrane surface. It could be clearly detected that a more potent analog of the melanotropic hormone alpha-MSH (Ac-Ser(1)-Tyr(2)-Ser(3)-Met(4)-Glu(5)-His(6)-Phe(7)-Arg(8)-Trp(9)-Gly(10)-Lys(11)-Pro(12)-Val(13)-NH(2)) was more effective in rigidifying the bilayer surface of fluid membranes than the hormone, though the hormone significantly decreases the bilayer surface hydration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A dor crônica é um desafio para a Medicina atual. Novos métodos e medicamentos têm sido propostos com o intuito de controlar os sintomas álgicos. A via de administração subaracnóidea tem se mostrado como uma alternativa viável e segura, embora necessite continuamente ser objeto de estudo de muitos pesquisadores. O objetivo deste trabalho é fazer uma revisão dos medicamentos disponíveis no arsenal terapêutico já consagrados pelo uso e os que se mostram promissores na atualidade para a prática clínica diária. CONTEÚDO: Nesta revisão são avaliados vários fármacos que apresentam ação analgésica quando utilizada via neuroeixo. Opióides, anestésicos locais, agonistas alfa2-adrenérgicos, antagonistas dos aminoácidos excitatórios e inibitórios, acetilcolina, inibidores da acetilcolinesterase, bloqueadores dos canais de cálcio, adenosina, serotonina, antidepressivos tricíclicos e inibidores da síntese de prostaglandinas são analisados no que concerne aos seus efeitos farmacológicos, incluindo os indesejáveis. CONCLUSÕES: Muitos avanços foram registrados no controle dos sintomas álgicos após a utilização das substâncias citadas por via raquidiana, onde certamente algumas serão aproveitadas e enriquecerão o arsenal terapêutico e outras relegadas temporária ou definitivamente. Entretanto, ainda serão necessários muitos estudos clínicos e experimentais para que estes conhecimentos possam ser incorporados e utilizados com segurança pelos profissionais que lidam com o tratamento da dor crônica.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: A peridural (AP) e a técnica de duplo bloqueio (DB) são utilizadas em analgesia para o trabalho de parto. Este estudo comparou os efeitos na mãe e no feto de ambas as técnicas em analgesia e anestesia para o parto. MÉTODOS: Quarenta parturientes ASA I e II receberam por via peridural 15 ml de ropivacaína a 0,125% (grupo AP) e 5 µg de sufentanil com 2,5 mg bupivacaína por via subaracnóidea (grupo DB). Foram avaliados: intensidade de dor, altura do bloqueio sensitivo, tempo de latência, bloqueio motor, duração da analgesia de parto, tempo para a resolução do parto, hipotensão materna e presença de prurido. Os recém-nascidos foram avaliados pelo índice de Apgar e escore da capacidade adaptativa e neurológica (ECAN), método de Amiel-Tison. RESULTADOS: Não houve diferenças significativas entre os grupos na intensidade da dor, no tempo de latência, no nível do bloqueio sensitivo e no índice de Apgar. O bloqueio motor, a duração da analgesia e o tempo para resolução do parto foram maiores no grupo DB, do qual sete parturientes apresentaram prurido leve. ECAN foi maior no grupo AP após meia hora, duas horas e 24 horas. Noventa e cinco por cento dos recém-nascidos do grupo AP e 60% do grupo DB foram considerados neurologicamente vigorosos ao exame de 24 horas. CONCLUSÃO: As duas técnicas mostraram-se eficazes para analgesia do trabalho de parto. As parturientes do grupo DB apresentaram prurido e trabalho de parto mais prolongado. Recém-nascidos de mães que receberam analgesia de parto via peridural apresentaram melhor ECAN.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A raquianestesia unilateral pode apresentar vantagens em pacientes ambulatoriais. O objetivo deste trabalho foi comparar a raquianestesia unilateral com o bloqueio combinado femoral-isquiático em cirurgias ortopédicas unilaterais e ambulatoriais. MÉTODO: Sessenta pacientes foram aleatoriamente separados em dois grupos para receber 6 mg de bupivacaína hiperbárica ou hipobárica (grupo RQ) em decúbito lateral esquerdo ou 800 mg de lidocaína 1,6% com epinefrina nos nervos femoral e isquiático (grupo CFI) em decúbito dorsal. O bloqueio dos nervos foi realizado com agulha de 150 mm conectada a um neuroestimulador e inserida no ponto médio entre as duas abordagens clássicas, sendo injetados 15 mL no nervo femoral e 35 mL no nervo isquiático. Avaliados o tempo para realização dos bloqueios e sua duração. Vinte minutos após, os pacientes foram avaliados em relação aos bloqueios sensitivo e motor. RESULTADOS: O tempo para a realização da raquianestesia foi significativamente menor do que o bloqueio combinado femoral-isquiático. O bloqueio unilateral foi obtido em 90% dos pacientes no grupo RQ e 100% no grupo CFI. O tempo para recuperação do bloqueio sensitivo e motor foi significativamente maior no grupo CFI. Não houve bradicardia ou hipotensão. CONCLUSÕES: Este estudo conclui que é tecnicamente fácil realizar bloqueio anterior combinado femoral-isquiático e pode ser uma alternativa para o bloqueio unilateral do membro inferior. A raquianestesia unilateral com baixas doses de bupivacaína resultou em menor tempo para realização, menor número de tentativas e recuperação mais precoce do bloqueio combinado femoral-isquiático, porém com mesma efetividade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To assess cardiopulmonary and analgesic effects after administration of ropivacaine into the caudal epidural space of cattle.Study design Prospective, single-dose trial.Animals Eight healthy mixed breed cows aged 8 +/- 5 years and weighing 507 +/- 112 kg.Methods Caudal epidural anesthesia was produced in cows with 0.75% ropivacaine (0.11 mg kg(-1)). Onset time, duration and cranial spread of analgesia were recorded. Heart rate (HR), respiratory rate (f(R)), rectal temperature (RT), and mean arterial blood pressure (MAP) were measured prior to epidural administration (T-0) and at 15, 30, 60, 120, 180 and 240 minutes after epidural administration (T-15, T-30, T-60, T-120, T-180 and T-240). Arterial blood acid-base balance (pH, standard bicarbonate and base excess), gas tension (PaO2, PaCO2, SaO(2)) and electrolytes (Na+, K+, iCa(2+), Cl-) were recorded at T-0, T-30, T-60, T-120, T-180 and T-240. Ataxia was evaluated at T-0, T-30, T-60, T-120, T-180 and T-240 and at 1 hour intervals thereafter until analgesia was no longer present in each animal.Results Epidurally administered ropivacaine induced variable analgesia extending bilaterally from the coccyx to S3. Time to onset of analgesia and mean duration in the perineal area were 15 +/- 4 and 359 +/- 90 minutes, respectively. Respiratory rate and RT increased from T-120 to T-240 when compared to the value at T-0. Ionized calcium and chloride concentrations increased at T-180 and T-240 when compared to T-0. The other variables were not significantly different from baseline values (p > 0.05). Four animals were mildly ataxic.Conclusion and clinical relevance Ropivacaine (0.75%, 0.11 mg kg(-1)) can be administered by caudal epidural injection to produce prolonged bilateral perineal analgesia with minimal ataxia and cardiopulmonary changes in standing cattle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction. Premature ejaculation is one of the most common male sexual dysfunctions. Current pharmacological treatments involve reduction in penile sensitivity by local anesthetics or increase of ejaculatory threshold by selective serotonin reuptake inhibitors. a1-Adrenoceptors (a1-ARs) and L-type calcium channels are expressed in the smooth muscles of the male reproductive tract, and their activations play an important role in the physiological events involved in the seminal emission phase of ejaculation.Aim. To evaluate if the inhibition of the contractility of the vas deferens and seminal vesicle by alpha(1)-AR antagonism or the L-type calcium channel blockade can delay ejaculation.Methods. The effects of the alpha(1)-AR antagonist tamsulosin and of the L-type calcium channel blockers, nifedipine and (S)-(+)-niguldipine, on contractions induced by norepinephrine in the rat vas deferens and seminal vesicles in vitro and on the ejaculation latency of male rats in behavioral mating tests were evaluated.Main Outcome Measure. Tension development of vas deferens and seminal vesicles in response to norepinephrine in vitro and behavioral mating parameters were quantified.Results. Tension development of vas deferens and seminal vesicle to alpha(1)-AR activation was significantly inhibited by tamsulosin, nifedipine, and (S)-(+)-niguldipine. Tamsulosin displayed insurmountable antagonism of contractions induced by norepinephrine in the rat vas deferens and seminal vesicle. Ejaculation latency of male rats was not modified by tamsulosin, nifedipine, or (S)-(+)-niguldipine; however, both the number and weight of the seminal plugs recovered from female rats mated with male rats treated with tamsulosin were significantly reduced.Conclusion. Seminal emission impairment by inhibition of vas deferens or seminal vesicle contractility by L-type calcium channel blockade or alpha(1)-AR antagonism is not able to delay the ejaculation. de Almeida Kiguti LR and Pupo AS. Investigation of the effects of alpha(1)-adrenoceptor antagonism and L-type calcium channel blockade on ejaculation and vas deferens and seminal vesicle contractility in vitro. J Sex Med 2012; 9: 159-168.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: O objetivo desde artigo foi relatar um caso clínico de fechamento de fístula buco-sinusal tardia utilizando rotação de enxerto de tecido adiposo pediculado do corpo adiposo da bochecha. DESCRIÇÃO do CASO: Paciente do sexo masculino, 66 anos, leucoderma, em boas condições de saúde geral, foi encaminhado para fechamento de extensa comunicação buco-sinusal. Ao exame clínico, observou-se uma fístula de aproximadamente 10 mm de diâmetro comunicando a cavidade oral com o seio maxilar. A cirurgia foi realizada em nível ambulatorial, sob anestesia local, para fechar a fístula buco-sinusal com um enxerto de tecido adiposo pediculado do corpo adiposo da bochecha. A reparação da ferida e o fechamento do defeito foram observados no pós-operatório de 30 dias, com completa epitelização. CONCLUSÃO: O enxerto pediculado de tecido do corpo adiposo da bochecha mostrou-se uma alternativa simples, eficaz e segura no fechamento mediato da fístula buco-sinusal apresentada neste caso clínico.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the influence of intrapulpal pressure and dentin depth on bond strengths of an etch-and-rinse and a self-etching bonding agent to dentin in vitro and in vivo. Twenty-four pairs of premolars were randomly divided into four groups (n = 6) according to the dentin bonding agent, Single Bond and Clearfil SE Bond, and intrapulpal pressure, null or positive. Each tooth of the pair was further designated to be treated in vivo or in vitro. The intrapulpal pressure was controlled in vivo by the delivery of local anesthetics containing or not a vasoconstrictor, while in vitro, it was achieved by keeping the teeth under hydrostatic pressure. Class I cavities were prepared and the dentin bonding agents were applied followed by incremental resin restoration. For the teeth treated in vitro, the same restorative procedures were performed after a 6 month-storage period. Beams with I mm 2 cross-sectional area were prepared and, microtensile tested. Clearfil SE Bond was not influenced by any of the variables of the study, while bond strengths produced in vitro were significatly higher for Single Bond. Overall, lower bond strengths were produced in deep dentin, which reached statistical significance when Single Bond was applied under physiological or simulated intrapulpal pressure. In conclusion, in vitro bonding may overestimate the immediate adhesive performance of more technique-sensitive dentin bonding systems. The impact of intrapulpal pressure on bond strength seems to be more adhesive dependent than dentin morphological characteristics related to depth. (C) 2007 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objectives. The study investigated possible neurotoxic effects of increasing concentrations and doses of bupivacaine administered into the subarachnoid space in dogs. Methods. Fifty animals were allocated to five experimental groups: G1, control; G2, 5 mg 0.5 bupivacaine in 10% glucose solution; G3, 10 mg of 1% bupivacaine in 10% glucose solution; G4, 20 mg 2% bupivacaine in 10% glucose solution, and G5, 20 mg 2% bupivacaine in water. After 72 hours of observation, the animals were killed and the spinal cords removed for histologic examination by light microscopy. Results. None of the animals showed any neurologic clinical disturbance following recovery from spinal anesthesia. One case of necrosis of nerve tissue was observed in G3 and four in G4. Conclusions. Increasing concentrations and doses of hyperbaric bupivacaine solutions increased the incidence of nerve tissue damage, which did not occur with hypobaric solutions. These results should contribute to the further understanding of neurologic complications following spinal anesthesia when large doses of local anesthetics in hyperbaric solutions are used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Local anesthetics are able to induce pain relief since they bind to the sodium channel of excitable membranes, blocking the influx of sodium ions and the propagation of the nervous impulse. Benzocaine (BZC) is a local anesthetic that presents limited application in topical formulations due to its low water-solubility. This study aimed to develop polymeric nanocapsules as a drug delivery system for the local anesthetic benzocaine (BZC). To do so, BZC loaded poly(D,L-lactide-co-glycolide) (PLGA) nanocapsules were prepared using the nanoprecipitation method and were characterized. The factorial experimental design was used to study the influence of four different independent variables oil response to nanocapsules drug loading. The physical characteristics of PLGA nanocapsules were evaluated by analyzing the particle size, the polydispersion index and the zeta potential, using a particle size analyzer. The results of the optimized formulation showed a size distribution with a polydispersity index of 0.12. an average diameter of 123 nm, zeta potential of -33.6 mV and a drug loading of more than 69%. The release profiles showed a significant difference in the release behavior for the pure drug in solution when compared with that containing benzocaine loaded PLGA nanocapsules. Thus, the prepared nonocapsules described here may be of clinical importance in both the processes of stabilization and delivery of benzocaine for pain treatment. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To compare the effect of intraperitoneal (IP) or incisional (INC) bupivacaine on pain and the analgesic requirement after ovariohysterectomy in dogs.Study design Prospective, randomized clinical study.Animals Thirty female dogs undergoing ovariohysterectomy (OHE).Methods Dogs admitted for elective OHE were anesthetized with acepromazine, butorphanol, thiopental and halothane. Animals were randomly assigned to one of three groups (n = 10 per group). The treatments consisted of preincisional infiltration with saline solution (NaCl 0.9%) or bupivacaine with epinephrine and/or IP administration of the same solutions, as follows: INC and IP 0.9% NaCl (control group); INC 0.9% NaCl and IP bupivacaine (5 mg kg(-1), IP group); INC bupivacaine (1 mg kg(-1)) and IP 0.9% NaCl (INC group). Postoperative pain was evaluated by a blinded observer for 24 hours after extubation by means of a visual analog scale (VAS) and a numeric rating scale (NRS). Rescue analgesia (morphine, 0.5 mg kg(-1), IM) was administered if the VAS was > 5/10 or the NRS > 10/29.Results At 1 hour after anesthesia, VAS pain scores were [medians (interquartile range)]: 6.4 (3.1-7.9), 0.3 (0.0-2.6) and 0.0 (0.0-7.0) in control, IP and INC groups, respectively. VAS pain scores were lower in the IP compared to the control group. Over the first 24 hours, rescue analgesia was administered to 7/10, 5/10 and 3/10 dogs of the control, INC and IP groups, respectively. Total number of dogs given rescue analgesia over the first 24 hours did not differ significantly among groups.Conclusions and clinical relevance Intraperitoneal bupivacaine resulted in lower pain scores during the first hour of the postoperative period and there was a trend towards a decreased need for rescue analgesia after OHE in dogs.