998 resultados para Java Advanced Imaging


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capability of a device called the Spherical Geodesic Waveguide (SGW) to produce images with details below the classic Abbe diffraction limit (super-resolution) is analyzed here. The SGW is an optical system equivalent (by means of Transformation Optics) to the Maxwell Fish Eye (MFE) refractive index distribution. Recently, it has been claimed that the necessary condition to get super-resolution in the MFE and the SGW is the use of a Perfect Point Drain (PPD). The PPD is a punctual receptor placed in the focal point that absorbs the incident wave, without reflection or scattering. A microwave circuit comprising three elements, the SGW, the source and the drain (two coaxial lines loaded with specific impedances) is designed and simulated in COMSOL. The super-resolution properties have been analyzed for different position of the source and drain and for two different load impedances: the PPD and the characteristic line impedance. The results show that in both cases super-resolution occurs only for discrete number of frequencies. Out of these frequencies, the SGW does not show SR in the analysis carried out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La concentración fotovoltaica (CPV) es una de las formas más prometedoras de reducir el coste de la energía proveniente del sol. Esto es posible gracias a células solares de alta eficiencia y a una significativa reducción del tamaño de la misma, que está fabricada con costosos materiales semiconductores. Ambos aspectos están íntimamente ligados ya que las altas eficiencias solamente son posibles con materiales y tecnologías de célula caros, lo que forzosamente conlleva una reducción del tamaño de la célula si se quiere lograr un sistema rentable. La reducción en el tamaño de las células requiere que la luz proveniente del sol ha de ser redirigida (es decir, concentrada) hacia la posición de la célula. Esto se logra colocando un concentrador óptico encima de la célula. Estos concentradores para CPV están formados por diferentes elementos ópticos fabricados en materiales baratos, con el fin de reducir los costes de producción. El marco óptimo para el diseño de concentradores es la óptica anidólica u óptica nonimaging. La óptica nonimaging fue desarrollada por primera vez en la década de los años sesenta y ha ido evolucionando significativamente desde entonces. El objetivo de los diseños nonimaging es la transferencia eficiente de energía entre la fuente y el receptor (sol y célula respectivamente, en el caso de la CPV), sin tener en cuenta la formación de imagen. Los sistemas nonimaging suelen ser simples, están compuestos de un menor número de superficies que los sistemas formadores de imagen y son más tolerantes a errores de fabricación. Esto hace de los sistemas nonimaging una herramienta fundamental, no sólo en el diseño de concentradores fotovoltaicos, sino también en el diseño de otras aplicaciones como iluminación, proyección y comunicaciones inalámbricas ópticas. Los concentradores ópticos nonimaging son adecuados para aplicaciones CPV porque el objetivo no es la reproducción de una imagen exacta del sol (como sería el caso de las ópticas formadoras de imagen), sino simplemente la colección de su energía sobre la célula solar. Los concentradores para CPV pueden presentar muy diferentes arquitecturas y elementos ópticos, dando lugar a una gran variedad de posibles diseños. El primer elemento óptico que es atravesado por la luz del sol se llama Elemento Óptico Primario (POE en su nomenclatura anglosajona) y es el elemento más determinante a la hora de definir la forma y las propiedades del concentrador. El POE puede ser refractivo (lente) o reflexivo (espejo). Esta tesis se centra en los sistemas CPV que presentan lentes de Fresnel como POE, que son lentes refractivas delgadas y de bajo coste de producción que son capaces de concentrar la luz solar. El capítulo 1 expone una breve introducción a la óptica geométrica y no formadora de imagen (nonimaging), explicando sus fundamentos y conceptos básicos. Tras ello, la integración Köhler es presentada en detalle, explicando sus principios, válidos tanto para aplicaciones CPV como para iluminación. Una introducción a los conceptos fundamentales de CPV también ha sido incluida en este capítulo, donde se analizan las propiedades de las células solares multiunión y de los concentradores ópticos empleados en los sistemas CPV. El capítulo se cierra con una descripción de las tecnologías existentes empleadas para la fabricación de elementos ópticos que componen los concentradores. El capítulo 2 se centra principalmente en el diseño y desarrollo de los tres concentradores ópticos avanzados Fresnel Köhler que se presentan en esta tesis: Fresnel-Köhler (FK), Fresnel-Köhler curvo (DFK) y Fresnel-Köhler con cavidad (CFK). Todos ellos llevan a cabo integración Köhler y presentan una lente de Fresnel como su elemento óptico primario. Cada uno de estos concentradores CPV presenta sus propias propiedades y su propio procedimiento de diseño. Además, presentan todas las características que todo concentrador ha de tener: elevado factor de concentración, alta tolerancia de fabricación, alta eficiencia óptica, irradiancia uniforme sobre la superficie de la célula y bajo coste de producción. Los concentradores FK y DFK presentan una configuración de cuatro sectores para lograr la integración Köhler. Esto quiere decir que POE y SOE se dividen en cuatro sectores simétricos cada uno, y cada sector del POE trabaja conjuntamente con su correspondiente sector de SOE. La principal diferencia entre los dos concentradores es que el POE del FK es una lente de Fresnel plana, mientras que una lente curva de Fresnel es empleada como POE del DFK. El concentrador CFK incluye una cavidad de confinamiento externo integrada, que es un elemento óptico capaz de recuperar los rayos reflejados por la superficie de la célula con el fin de ser reabsorbidos por la misma. Por tanto, se aumenta la absorción de la luz, lo que implica un aumento en la eficiencia del módulo. Además, este capítulo también explica un método de diseño alternativo para los elementos faceteados, especialmente adecuado para las lentes curvas como el POE del DFK. El capítulo 3 se centra en la caracterización y medidas experimentales de los concentradores ópticos presentados en el capítulo 2, y describe sus procedimientos. Estos procedimientos son en general aplicables a cualquier concentrador basado en una lente de Fresnel, e incluyen tres tipos principales de medidas experimentales: eficiencia eléctrica, ángulo de aceptancia y uniformidad de la irradiancia en el plano de la célula. Los resultados que se muestran a lo largo de este capítulo validarán a través de medidas a sol real las características avanzadas que presentan los concentradores Köhler, y que se demuestran en el capítulo 2 mediante simulaciones de rayos. Cada concentrador (FK, DFK y CFK) está diseñado y optimizado teniendo en cuenta condiciones de operación realistas. Su rendimiento se modela de forma exhaustiva mediante el trazado de rayos en combinación con modelos distribuidos para la célula. La tolerancia es un asunto crítico de cara al proceso de fabricación, y ha de ser máxima para obtener sistemas de producción en masa rentables. Concentradores con tolerancias limitadas generan bajadas significativas de eficiencia a nivel de array, causadas por el desajuste de corrientes entre los diferentes módulos (principalmente debido a errores de alineación en la fabricación). En este sentido, la sección 3.5 presenta dos métodos matemáticos que estiman estas pérdidas por desajuste a nivel de array mediante un análisis de sus curvas I-V, y por tanto siendo innecesarias las medidas a nivel de mono-módulo. El capítulo 3 también describe la caracterización indoor de los elementos ópticos que componen los concentradores, es decir, de las lentes de Fresnel que actúan como POE y de los secundarios free-form. El objetivo de esta caracterización es el de evaluar los adecuados perfiles de las superficies y las transmisiones ópticas de los diferentes elementos analizados, y así hacer que el rendimiento del módulo sea el esperado. Esta tesis la cierra el capítulo 4, en el que la integración Köhler se presenta como una buena alternativa para obtener distribuciones uniformes en aplicaciones de iluminación de estado sólido (iluminación con LED), siendo particularmente eficaz cuando se requiere adicionalmente una buena mezcla de colores. En este capítulo esto se muestra a través del ejemplo particular de un concentrador DFK, el cual se ha utilizado para aplicaciones CPV en los capítulos anteriores. Otra alternativa para lograr mezclas cromáticas apropiadas está basada en un método ya conocido (deflexiones anómalas), y también se ha utilizado aquí para diseñar una lente TIR aplanética delgada. Esta lente cumple la conservación de étendue, asegurando así que no hay bloqueo ni dilución de luz simultáneamente. Ambos enfoques presentan claras ventajas sobre las técnicas clásicas empleadas en iluminación para obtener distribuciones de iluminación uniforme: difusores y mezcla caleidoscópica mediante guías de luz. ABSTRACT Concentrating Photovoltaics (CPV) is one of the most promising ways of reducing the cost of energy collected from the sun. This is possible thanks to both, very high-efficiency solar cells and a large decrease in the size of cells, which are made of costly semiconductor materials. Both issues are closely linked since high efficiency values are only possible with expensive cell materials and technologies, implying a compulsory area reduction if cost-effectiveness is desired. The reduction in the cell size requires that light coming from the sun must be redirected (i.e. concentrated) towards the cell position. This is achieved by placing an optical concentrator system on top of the cell. These CPV concentrators consist of different optical elements manufactured on cheap materials in order to maintain low production costs. The optimal framework for the design of concentrators is nonimaging optics. Nonimaging optics was first developed in the 60s decade and has been largely developed ever since. The aim of nonimaging devices is the efficient transfer of light power between the source and the receiver (sun and cell respectively in the case of CPV), disregarding image formation. Nonimaging systems are usually simple, comprised of fewer surfaces than imaging systems and are more tolerant to manufacturing errors. This renders nonimaging optics a fundamental tool, not only in the design of photovoltaic concentrators, but also in the design of other applications as illumination, projection and wireless optical communications. Nonimaging optical concentrators are well suited for CPV applications because the goal is not the reproduction of an exact image of the sun (as imaging optics would provide), but simply the collection of its energy on the solar cell. Concentrators for CPV may present very different architectures and optical elements, resulting in a vast variety of possible designs. The first optical element that sunlight goes through is called the Primary Optical Element (POE) and is the most determinant element in order to define the shape and properties of the whole concentrator. The POE can be either refractive (lens) or reflective (mirror). This thesis focuses on CPV systems based on Fresnel lenses as POE, which are thin and inexpensive refractive lenses able to concentrate sunlight. Chapter 1 exposes a short introduction to geometrical and nonimaging optics, explaining their fundamentals and basic concepts. Then, the Köhler integration is presented in detail, explaining its principles, valid for both applications: CPV and illumination. An introduction to CPV fundamental concepts is also included in this chapter, analyzing the properties of multijunction solar cells and optical concentrators employed in CPV systems. The chapter is closed with a description of the existing technologies employed for the manufacture of optical elements composing the concentrator. Chapter 2 is mainly devoted to the design and development of the three advanced Fresnel Köhler optical concentrators presented in this thesis work: Fresnel-Köhler (FK), Dome-shaped Fresnel-Köhler (DFK) and Cavity Fresnel-Köhler (CFK). They all perform Köhler integration and comprise a Fresnel lens as their Primary Optical Element. Each one of these CPV concentrators presents its own characteristics, properties and its own design procedure. Their performances include all the key issues in a concentrator: high concentration factor, large tolerances, high optical efficiency, uniform irradiance on the cell surface and low production cost. The FK and DFK concentrators present a 4-fold configuration in order to perform the Köhler integration. This means that POE and SOE are divided into four symmetric sectors each one, working each POE sector with its corresponding SOE sector by pairs. The main difference between both concentrators is that the POE of the FK is a flat Fresnel lens, while a dome-shaped (curved) Fresnel lens performs as the DFK’s POE. The CFK concentrator includes an integrated external confinement cavity, which is an optical element able to recover rays reflected by the cell surface in order to be re-absorbed by the cell. It increases the light absorption, entailing an increase in the efficiency of the module. Additionally, an alternative design method for faceted elements will also be explained, especially suitable for dome-shaped lenses as the POE of the DFK. Chapter 3 focuses on the characterization and experimental measurements of the optical concentrators presented in Chapter 2, describing their procedures. These procedures are in general applicable to any Fresnel-based concentrator as well and include three main types of experimental measurements: electrical efficiency, acceptance angle and irradiance uniformity at the solar cell plane. The results shown along this chapter will validate through outdoor measurements under real sun operation the advanced characteristics presented by the Köhler concentrators, which are demonstrated in Chapter 2 through raytrace simulation: high optical efficiency, large acceptance angle, insensitivity to manufacturing tolerances and very good irradiance uniformity on the cell surface. Each concentrator (FK, DFK and CFK) is designed and optimized looking at realistic performance characteristics. Their performances are modeled exhaustively using ray tracing combined with cell modeling, taking into account the major relevant factors. The tolerance is a critical issue when coming to the manufacturing process in order to obtain cost-effective mass-production systems. Concentrators with tight tolerances result in significant efficiency drops at array level caused by current mismatch among different modules (mainly due to manufacturing alignment errors). In this sense, Section 3.5 presents two mathematical methods that estimate these mismatch losses for a given array just by analyzing its full-array I-V curve, hence being unnecessary any single mono-module measurement. Chapter 3 also describes the indoor characterization of the optical elements composing the concentrators, i.e. the Fresnel lenses acting as POEs and the free-form SOEs. The aim of this characterization is to assess the proper surface profiles and optical transmissions of the different elements analyzed, so they will allow for the expected module performance. This thesis is closed by Chapter 4, in which Köhler integration is presented as a good approach to obtain uniform distributions in Solid State Lighting applications (i.e. illumination with LEDs), being particularly effective when dealing with color mixing requirements. This chapter shows it through the particular example of a DFK concentrator, which has been used for CPV applications in the previous chapters. An alternative known method for color mixing purposes (anomalous deflections) has also been used to design a thin aplanatic TIR lens. This lens fulfills conservation of étendue, thus ensuring no light blocking and no light dilution at the same time. Both approaches present clear advantages over the classical techniques employed in lighting to obtain uniform illumination distributions: diffusers and kaleidoscopic lightpipe mixing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This document is the result of a process of web development to create a tool that will allow to Cracow University of Technology consult, create and manage timetables. The technologies chosen for this purpose are Apache Tomcat Server, My SQL Community Server, JDBC driver, Java Servlets and JSPs for the server side. The client part counts on Javascript, jQuery, AJAX and CSS technologies to perform the dynamism. The document will justify the choice of these technologies and will explain some development tools that help in the integration and development of all this elements: specifically, NetBeans IDE and MySQL workbench have been used as helpful tools. After explaining all the elements involved in the development of the web application, the architecture and the code developed are explained through UML diagrams. Some implementation details related to security are also deeper explained through sequence diagrams. As the source code of the application is provided, an installation manual has been developed to run the project. In addition, as the platform is intended to be a beta that will be grown, some unimplemented ideas for future development are also exposed. Finally, some annexes with important files and scripts related to the initiation of the platform are attached. This project started through an existing tool that needed to be expanded. The main purpose of the project along its development has focused on setting the roots for a whole new platform that will replace the existing one. For this goal, it has been needed to make a deep inspection on the existing web technologies: a web server and a SQL database had to be chosen. Although the alternatives were a lot, Java technology for the server was finally selected because of the big community backwards, the easiness of modelling the language through UML diagrams and the fact of being free license software. Apache Tomcat is the open source server that can use Java Servlet and JSP technology. Related to the SQL database, MySQL Community Server is the most popular open-source SQL Server, with a big community after and quite a lot of tools to manage the server. JDBC is the driver needed to put in contact Java and MySQL. Once we chose the technologies that would be part of the platform, the development process started. After a detailed explanation of the development environment installation, we used UML use case diagrams to set the main tasks of the platform; UML class diagrams served to establish the existing relations between the classes generated; the architecture of the platform was represented through UML deployment diagrams; and Enhanced entity–relationship (EER) model were used to define the tables of the database and their relationships. Apart from the previous diagrams, some implementation issues were explained to make a better understanding of the developed code - UML sequence diagrams helped to explain this. Once the whole platform was properly defined and developed, the performance of the application has been shown: it has been proved that with the current state of the code, the platform covers the use cases that were set as the main target. Nevertheless, some requisites needed for the proper working of the platform have been specified. As the project is aimed to be grown, some ideas that could not be added to this beta have been explained in order not to be missed for future development. Finally, some annexes containing important configuration issues for the platform have been added after proper explanation, as well as an installation guide that will let a new developer get the project ready. In addition to this document some other files related to the project are provided: - Javadoc. The Javadoc containing the information of every Java class created is necessary for a better understanding of the source code. - database_model.mwb. This file contains the model of the database for MySQL Workbench. This model allows, among other things, generate the MySQL script for the creation of the tables. - ScheduleManager.war. The WAR file that will allow loading the developed application into Tomcat Server without using NetBeans. - ScheduleManager.zip. The source code exported from NetBeans project containing all Java packages, JSPs, Javascript files and CSS files that are part of the platform. - config.properties. The configuration file to properly get the names and credentials to use the database, also explained in Annex II. Example of config.properties file. - db_init_script.sql. The SQL query to initiate the database explained in Annex III. SQL statements for MySQL initialization. RESUMEN. Este proyecto tiene como punto de partida la necesidad de evolución de una herramienta web existente. El propósito principal del proyecto durante su desarrollo se ha centrado en establecer las bases de una completamente nueva plataforma que reemplazará a la existente. Para lograr esto, ha sido necesario realizar una profunda inspección en las tecnologías web existentes: un servidor web y una base de datos SQL debían ser elegidos. Aunque existen muchas alternativas, la tecnología Java ha resultado ser elegida debido a la gran comunidad de desarrolladores que tiene detrás, además de la facilidad que proporciona este lenguaje a la hora de modelarlo usando diagramas UML. Tampoco hay que olvidar que es una tecnología de uso libre de licencia. Apache Tomcat es el servidor de código libre que permite emplear Java Servlets y JSPs para hacer uso de la tecnología de Java. Respecto a la base de datos SQL, el servidor más popular de código libre es MySQL, y cuenta también con una gran comunidad detrás y buenas herramientas de modelado, creación y gestión de la bases de datos. JDBC es el driver que va a permitir comunicar las aplicaciones Java con MySQL. Tras elegir las tecnologías que formarían parte de esta nueva plataforma, el proceso de desarrollo tiene comienzo. Tras una extensa explicación de la instalación del entorno de desarrollo, se han usado diagramas de caso de UML para establecer cuáles son los objetivos principales de la plataforma; los diagramas de clases nos permiten realizar una organización del código java desarrollado de modo que sean fácilmente entendibles las relaciones entre las diferentes clases. La arquitectura de la plataforma queda definida a través de diagramas de despliegue. Por último, diagramas EER van a definir las relaciones entre las tablas creadas en la base de datos. Aparte de estos diagramas, algunos detalles de implementación se van a justificar para tener una mejor comprensión del código desarrollado. Diagramas de secuencia ayudarán en estas explicaciones. Una vez que toda la plataforma haya quedad debidamente definida y desarrollada, se va a realizar una demostración de la misma: se demostrará cómo los objetivos generales han sido alcanzados con el desarrollo actual del proyecto. No obstante, algunos requisitos han sido aclarados para que la plataforma trabaje adecuadamente. Como la intención del proyecto es crecer (no es una versión final), algunas ideas que se han podido llevar acabo han quedado descritas de manera que no se pierdan. Por último, algunos anexos que contienen información importante acerca de la plataforma se han añadido tras la correspondiente explicación de su utilidad, así como una guía de instalación que va a permitir a un nuevo desarrollador tener el proyecto preparado. Junto a este documento, ficheros conteniendo el proyecto desarrollado quedan adjuntos. Estos ficheros son: - Documentación Javadoc. Contiene la información de las clases Java que han sido creadas. - database_model.mwb. Este fichero contiene el modelo de la base de datos para MySQL Workbench. Esto permite, entre otras cosas, generar el script de iniciación de la base de datos para la creación de las tablas. - ScheduleManager.war. El fichero WAR que permite desplegar la plataforma en un servidor Apache Tomcat. - ScheduleManager.zip. El código fuente exportado directamente del proyecto de Netbeans. Contiene todos los paquetes de Java generados, ficheros JSPs, Javascript y CSS que forman parte de la plataforma. - config.properties. Ejemplo del fichero de configuración que permite obtener los nombres de la base de datos - db_init_script.sql. Las consultas SQL necesarias para la creación de la base de datos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Researchers evaluating angiomodulating compounds as a part of scientific projects or pre-clinical studies are often confronted with limitations of applied animal models. The rough and insufficient early-stage compound assessment without reliable quantification of the vascular response counts, at least partially, to the low transition rate to clinics. OBJECTIVE To establish an advanced, rapid and cost-effective angiogenesis assay for the precise and sensitive assessment of angiomodulating compounds using zebrafish caudal fin regeneration. It should provide information regarding the angiogenic mechanisms involved and should include qualitative and quantitative data of drug effects in a non-biased and time-efficient way. APPROACH & RESULTS Basic vascular parameters (total regenerated area, vascular projection area, contour length, vessel area density) were extracted from in vivo fluorescence microscopy images using a stereological approach. Skeletonization of the vasculature by our custom-made software Skelios provided additional parameters including "graph energy" and "distance to farthest node". The latter gave important insights into the complexity, connectivity and maturation status of the regenerating vascular network. The employment of a reference point (vascular parameters prior amputation) is unique for the model and crucial for a proper assessment. Additionally, the assay provides exceptional possibilities for correlative microscopy by combining in vivo-imaging and morphological investigation of the area of interest. The 3-way correlative microscopy links the dynamic changes in vivo with their structural substrate at the subcellular level. CONCLUSIONS The improved zebrafish fin regeneration model with advanced quantitative analysis and optional 3-way correlative morphology is a promising in vivo angiogenesis assay, well-suitable for basic research and preclinical investigations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Putrefaction of the brain is a challenge to a forensic pathologist because it may lead to considerable organ alterations and restrict documenting reliable autopsy findings. OBJECTIVES This study aims to present a new and systematic evaluation of possible benefits of post-mortem MR Neuroimaging (1.5 Tesla, sequences: T1w, T2w) in putrefied corpses in comparison to PMCT and autopsy. METHODS A post-mortem MRI brain examination was conducted on 35 adult, putrefied corpses after performing a whole body CT scan prior to a forensic autopsy. Imaging data and autopsy findings were compared with regard to brain symmetry, gray and white matter junction, ventricular system, basal ganglia, cerebellum, brain stem, and possible pathological findings. RESULTS At autopsy, a reliable assessment of the anatomical brain structures was often restricted. MR imaging offered an assessment of the anatomical brain structures, even at advanced stages of putrefaction. In two cases, MR imaging revealed pathological findings that were detectable neither by CT scans nor at autopsy. CONCLUSIONS Post-mortem MR imaging of putrefied brains offers the possibility to assess brain morphology, even if the brain is liquefied. Post-mortem MR imaging of the brain should be considered if the assessment of a putrefied brain is crucial to the evaluation of a forensic autopsy case.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, we compared contrast-enhanced ultrasound perfusion imaging with magnetic resonance perfusion-weighted imaging or perfusion computed tomography for detecting normo-, hypo-, and nonperfused brain areas in acute middle cerebral artery stroke. We performed high mechanical index contrast-enhanced ultrasound perfusion imaging in 30 patients. Time-to-peak intensity of 10 ischemic regions of interests was compared to four standardized nonischemic regions of interests of the same patient. A time-to-peak >3 s (ultrasound perfusion imaging) or >4 s (perfusion computed tomography and magnetic resonance perfusion) defined hypoperfusion. In 16 patients, 98 of 160 ultrasound perfusion imaging regions of interests of the ischemic hemisphere were classified as normal, and 52 as hypoperfused or nonperfused. Ten regions of interests were excluded due to artifacts. There was a significant correlation of the ultrasound perfusion imaging and magnetic resonance perfusion or perfusion computed tomography (Pearson`s chi-squared test 79.119, p < 0.001) (OR 0.1065, 95% CI 0.06-0.18). No perfusion in ultrasound perfusion imaging (18 regions of interests) correlated highly with diffusion restriction on magnetic resonance imaging (Pearson's chi-squared test 42.307, p < 0.001). Analysis of receiver operating characteristics proved a high sensitivity of ultrasound perfusion imaging in the diagnosis of hypoperfused area under the curve, (AUC = 0.917; p < 0.001) and nonperfused (AUC = 0.830; p < 0.001) tissue in comparison with perfusion computed tomography and magnetic resonance perfusion. We present a proof of concept in determining normo-, hypo-, and nonperfused tissue in acute stroke by advanced contrast-enhanced ultrasound perfusion imaging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine the acceptability of short term neo-adjuvant maximal androgen deprivation (MAD) to patients treated with external beam radiation for locally advanced prostate cancer. Methods: Between 1996 and 2000, 818 patients with locally advanced, but non-metastatic, prostate cancer were entered into a randomised clinical trial (TROG 96.01), which compared radiation treatment alone with the same radiation treatment and 3 or 6 months neo-adjuvant MAD with goserelin and flutamide. Relevant symptoms, and how troublesome they were to the patient, were scored using a self-assessment questionnaire. This was completed by the patient at registration, and at specified times during and after treatment. Patients taking flutamide had liver function tests checked at regular intervals. Results: All patients have completed at least 12 months follow-up after treatment. Nearly all patients completed planned treatment with goserelin, but 27% of patients in the 6-month MAD treatment arm, and 20% in the 3-month arm, had to stop flutamide early. This was mainly due to altered liver function (up to 17% patients) and bowel side effects (up to 8% patients). However, although flutamide resulted in more bowel symptoms for patients on MAD, there was significant reduction in some urinary symptoms on this treatment. Acute bowel and urinary side effects at the end of radiation treatment were similar in all treatment arms. Side effect severity was unrelated to radiation target volume size, which was reduced by MAD, but symptomatology prior to any treatment was a powerful predictor. Of the 36% of patients who were sexually active before any treatment, the majority became inactive whilst on MAD. However, sexual activity at 12 months after radiation treatment was similar in all treatment arms, indicating that the effects of short term MAD on sexual function are reversible. Conclusion: Despite temporary effects on sexual activity, and compliance difficulties with flutamide, short-term neo-adjuvant MAD was not perceived by patients to be a major inconvenience. If neo-adjuvant MAD in the way tested can be demonstrated to lead to improved biochemical control and/or survival, then patients would view these therapeutic gains as worthwhile. Compliance with short-term goserelin was excellent, confirming that LH-RH analogues have a potential role in more long-term adjuvant treatment. However, for more protracted androgen deprivation, survival advantages and deleterious effects need to be assessed in parallel, in order to determine the optimal duration of treatment. (C) 2003 Elsevier Ireland Ltd. All fights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This article reports the overall survival, failure-free survival, local failure, and late radiation toxicity of a phase II trial of preoperative radiotherapy with continuous infusion 5-fluorouracil for rectal cancer after a minimum 3.5 years of follow-up. METHODS: Eligible patients were those with newly diagnosed localized adenocarcinoma of the rectum, within 12 cm of the anal verge, staged T3-T4 and deemed suitable for curative resection. Radiotherapy (50.4 Gy in 28 fractions in five weeks and three days) was given with continuous infusion 5-fluorouracil throughout the course of radiotherapy. RESULTS: A total of 82 patients were accrued in 13 months. The median follow-up time was 4.1 (range, 2.3-4.5) years. There were 55 males (67 percent) and the median age was 59 (range, 27-87) years. Patients were staged pretreatment as T3 (89 percent) and resectable T4 (11 percent). Endorectal ultrasound was performed in 70 percent and magnetic resonance imaging in another 5 percent. The four-year overall and failure-free survival rates were 82 percent (95 percent Cl: 72-89) and 69 percent (95 percent Cl: 58-78), respectively. The cumulative incidence of local failure at four years was 3.9 percent (95 percent CI: 1.3-11). Risk of failures, local and distant, has not reached a plateau phase. CONCLUSION: This regimen can be delivered safely and without leading to a significant increase in late toxicity. It provides excellent local control and favorable overall survival. There is a need for longer follow-up than has commonly been used for the proper evaluation of failures after an effective regimen of preoperative chemoradiation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Imaging of the crystalline lens and intraocular lens is becoming increasingly more important to optimize the refractive outcome of cataract surgery, to detect and manage complications and to ascertain advanced intraocular lens performance. This review examines recent advances in anterior segment imaging. RECENT FINDINGS: The main techniques used for imaging the anterior segment are slit-lamp biomicroscopy, ultrasound biomicroscopy, scheimpflug imaging, phakometry, optical coherence tomography and magnetic resonance imaging. They have principally been applied to the assessment of intraocular lens centration, tilt, position relative to the iris and movement with ciliary body contraction. SUMMARY: Despite the advances in anterior chamber imaging technology, there is still the need for a clinical, high-resolution, true anatomical, noninvasive technique to image behind the peripheral iris. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This dissertation develops an image processing framework with unique feature extraction and similarity measurements for human face recognition in the thermal mid-wave infrared portion of the electromagnetic spectrum. The goals of this research is to design specialized algorithms that would extract facial vasculature information, create a thermal facial signature and identify the individual. The objective is to use such findings in support of a biometrics system for human identification with a high degree of accuracy and a high degree of reliability. This last assertion is due to the minimal to no risk for potential alteration of the intrinsic physiological characteristics seen through thermal infrared imaging. The proposed thermal facial signature recognition is fully integrated and consolidates the main and critical steps of feature extraction, registration, matching through similarity measures, and validation through testing our algorithm on a database, referred to as C-X1, provided by the Computer Vision Research Laboratory at the University of Notre Dame. Feature extraction was accomplished by first registering the infrared images to a reference image using the functional MRI of the Brain’s (FMRIB’s) Linear Image Registration Tool (FLIRT) modified to suit thermal infrared images. This was followed by segmentation of the facial region using an advanced localized contouring algorithm applied on anisotropically diffused thermal images. Thermal feature extraction from facial images was attained by performing morphological operations such as opening and top-hat segmentation to yield thermal signatures for each subject. Four thermal images taken over a period of six months were used to generate thermal signatures and a thermal template for each subject, the thermal template contains only the most prevalent and consistent features. Finally a similarity measure technique was used to match signatures to templates and the Principal Component Analysis (PCA) was used to validate the results of the matching process. Thirteen subjects were used for testing the developed technique on an in-house thermal imaging system. The matching using an Euclidean-based similarity measure showed 88% accuracy in the case of skeletonized signatures and templates, we obtained 90% accuracy for anisotropically diffused signatures and templates. We also employed the Manhattan-based similarity measure and obtained an accuracy of 90.39% for skeletonized and diffused templates and signatures. It was found that an average 18.9% improvement in the similarity measure was obtained when using diffused templates. The Euclidean- and Manhattan-based similarity measure was also applied to skeletonized signatures and templates of 25 subjects in the C-X1 database. The highly accurate results obtained in the matching process along with the generalized design process clearly demonstrate the ability of the thermal infrared system to be used on other thermal imaging based systems and related databases. A novel user-initialization registration of thermal facial images has been successfully implemented. Furthermore, the novel approach at developing a thermal signature template using four images taken at various times ensured that unforeseen changes in the vasculature did not affect the biometric matching process as it relied on consistent thermal features.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

X-ray computed tomography (CT) imaging constitutes one of the most widely used diagnostic tools in radiology today with nearly 85 million CT examinations performed in the U.S in 2011. CT imparts a relatively high amount of radiation dose to the patient compared to other x-ray imaging modalities and as a result of this fact, coupled with its popularity, CT is currently the single largest source of medical radiation exposure to the U.S. population. For this reason, there is a critical need to optimize CT examinations such that the dose is minimized while the quality of the CT images is not degraded. This optimization can be difficult to achieve due to the relationship between dose and image quality. All things being held equal, reducing the dose degrades image quality and can impact the diagnostic value of the CT examination.

A recent push from the medical and scientific community towards using lower doses has spawned new dose reduction technologies such as automatic exposure control (i.e., tube current modulation) and iterative reconstruction algorithms. In theory, these technologies could allow for scanning at reduced doses while maintaining the image quality of the exam at an acceptable level. Therefore, there is a scientific need to establish the dose reduction potential of these new technologies in an objective and rigorous manner. Establishing these dose reduction potentials requires precise and clinically relevant metrics of CT image quality, as well as practical and efficient methodologies to measure such metrics on real CT systems. The currently established methodologies for assessing CT image quality are not appropriate to assess modern CT scanners that have implemented those aforementioned dose reduction technologies.

Thus the purpose of this doctoral project was to develop, assess, and implement new phantoms, image quality metrics, analysis techniques, and modeling tools that are appropriate for image quality assessment of modern clinical CT systems. The project developed image quality assessment methods in the context of three distinct paradigms, (a) uniform phantoms, (b) textured phantoms, and (c) clinical images.

The work in this dissertation used the “task-based” definition of image quality. That is, image quality was broadly defined as the effectiveness by which an image can be used for its intended task. Under this definition, any assessment of image quality requires three components: (1) A well defined imaging task (e.g., detection of subtle lesions), (2) an “observer” to perform the task (e.g., a radiologists or a detection algorithm), and (3) a way to measure the observer’s performance in completing the task at hand (e.g., detection sensitivity/specificity).

First, this task-based image quality paradigm was implemented using a novel multi-sized phantom platform (with uniform background) developed specifically to assess modern CT systems (Mercury Phantom, v3.0, Duke University). A comprehensive evaluation was performed on a state-of-the-art CT system (SOMATOM Definition Force, Siemens Healthcare) in terms of noise, resolution, and detectability as a function of patient size, dose, tube energy (i.e., kVp), automatic exposure control, and reconstruction algorithm (i.e., Filtered Back-Projection– FPB vs Advanced Modeled Iterative Reconstruction– ADMIRE). A mathematical observer model (i.e., computer detection algorithm) was implemented and used as the basis of image quality comparisons. It was found that image quality increased with increasing dose and decreasing phantom size. The CT system exhibited nonlinear noise and resolution properties, especially at very low-doses, large phantom sizes, and for low-contrast objects. Objective image quality metrics generally increased with increasing dose and ADMIRE strength, and with decreasing phantom size. The ADMIRE algorithm could offer comparable image quality at reduced doses or improved image quality at the same dose (increase in detectability index by up to 163% depending on iterative strength). The use of automatic exposure control resulted in more consistent image quality with changing phantom size.

Based on those results, the dose reduction potential of ADMIRE was further assessed specifically for the task of detecting small (<=6 mm) low-contrast (<=20 HU) lesions. A new low-contrast detectability phantom (with uniform background) was designed and fabricated using a multi-material 3D printer. The phantom was imaged at multiple dose levels and images were reconstructed with FBP and ADMIRE. Human perception experiments were performed to measure the detection accuracy from FBP and ADMIRE images. It was found that ADMIRE had equivalent performance to FBP at 56% less dose.

Using the same image data as the previous study, a number of different mathematical observer models were implemented to assess which models would result in image quality metrics that best correlated with human detection performance. The models included naïve simple metrics of image quality such as contrast-to-noise ratio (CNR) and more sophisticated observer models such as the non-prewhitening matched filter observer model family and the channelized Hotelling observer model family. It was found that non-prewhitening matched filter observers and the channelized Hotelling observers both correlated strongly with human performance. Conversely, CNR was found to not correlate strongly with human performance, especially when comparing different reconstruction algorithms.

The uniform background phantoms used in the previous studies provided a good first-order approximation of image quality. However, due to their simplicity and due to the complexity of iterative reconstruction algorithms, it is possible that such phantoms are not fully adequate to assess the clinical impact of iterative algorithms because patient images obviously do not have smooth uniform backgrounds. To test this hypothesis, two textured phantoms (classified as gross texture and fine texture) and a uniform phantom of similar size were built and imaged on a SOMATOM Flash scanner (Siemens Healthcare). Images were reconstructed using FBP and a Sinogram Affirmed Iterative Reconstruction (SAFIRE). Using an image subtraction technique, quantum noise was measured in all images of each phantom. It was found that in FBP, the noise was independent of the background (textured vs uniform). However, for SAFIRE, noise increased by up to 44% in the textured phantoms compared to the uniform phantom. As a result, the noise reduction from SAFIRE was found to be up to 66% in the uniform phantom but as low as 29% in the textured phantoms. Based on this result, it clear that further investigation was needed into to understand the impact that background texture has on image quality when iterative reconstruction algorithms are used.

To further investigate this phenomenon with more realistic textures, two anthropomorphic textured phantoms were designed to mimic lung vasculature and fatty soft tissue texture. The phantoms (along with a corresponding uniform phantom) were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Scans were repeated a total of 50 times in order to get ensemble statistics of the noise. A novel method of estimating the noise power spectrum (NPS) from irregularly shaped ROIs was developed. It was found that SAFIRE images had highly locally non-stationary noise patterns with pixels near edges having higher noise than pixels in more uniform regions. Compared to FBP, SAFIRE images had 60% less noise on average in uniform regions for edge pixels, noise was between 20% higher and 40% lower. The noise texture (i.e., NPS) was also highly dependent on the background texture for SAFIRE. Therefore, it was concluded that quantum noise properties in the uniform phantoms are not representative of those in patients for iterative reconstruction algorithms and texture should be considered when assessing image quality of iterative algorithms.

The move beyond just assessing noise properties in textured phantoms towards assessing detectability, a series of new phantoms were designed specifically to measure low-contrast detectability in the presence of background texture. The textures used were optimized to match the texture in the liver regions actual patient CT images using a genetic algorithm. The so called “Clustured Lumpy Background” texture synthesis framework was used to generate the modeled texture. Three textured phantoms and a corresponding uniform phantom were fabricated with a multi-material 3D printer and imaged on the SOMATOM Flash scanner. Images were reconstructed with FBP and SAFIRE and analyzed using a multi-slice channelized Hotelling observer to measure detectability and the dose reduction potential of SAFIRE based on the uniform and textured phantoms. It was found that at the same dose, the improvement in detectability from SAFIRE (compared to FBP) was higher when measured in a uniform phantom compared to textured phantoms.

The final trajectory of this project aimed at developing methods to mathematically model lesions, as a means to help assess image quality directly from patient images. The mathematical modeling framework is first presented. The models describe a lesion’s morphology in terms of size, shape, contrast, and edge profile as an analytical equation. The models can be voxelized and inserted into patient images to create so-called “hybrid” images. These hybrid images can then be used to assess detectability or estimability with the advantage that the ground truth of the lesion morphology and location is known exactly. Based on this framework, a series of liver lesions, lung nodules, and kidney stones were modeled based on images of real lesions. The lesion models were virtually inserted into patient images to create a database of hybrid images to go along with the original database of real lesion images. ROI images from each database were assessed by radiologists in a blinded fashion to determine the realism of the hybrid images. It was found that the radiologists could not readily distinguish between real and virtual lesion images (area under the ROC curve was 0.55). This study provided evidence that the proposed mathematical lesion modeling framework could produce reasonably realistic lesion images.

Based on that result, two studies were conducted which demonstrated the utility of the lesion models. The first study used the modeling framework as a measurement tool to determine how dose and reconstruction algorithm affected the quantitative analysis of liver lesions, lung nodules, and renal stones in terms of their size, shape, attenuation, edge profile, and texture features. The same database of real lesion images used in the previous study was used for this study. That database contained images of the same patient at 2 dose levels (50% and 100%) along with 3 reconstruction algorithms from a GE 750HD CT system (GE Healthcare). The algorithms in question were FBP, Adaptive Statistical Iterative Reconstruction (ASiR), and Model-Based Iterative Reconstruction (MBIR). A total of 23 quantitative features were extracted from the lesions under each condition. It was found that both dose and reconstruction algorithm had a statistically significant effect on the feature measurements. In particular, radiation dose affected five, three, and four of the 23 features (related to lesion size, conspicuity, and pixel-value distribution) for liver lesions, lung nodules, and renal stones, respectively. MBIR significantly affected 9, 11, and 15 of the 23 features (including size, attenuation, and texture features) for liver lesions, lung nodules, and renal stones, respectively. Lesion texture was not significantly affected by radiation dose.

The second study demonstrating the utility of the lesion modeling framework focused on assessing detectability of very low-contrast liver lesions in abdominal imaging. Specifically, detectability was assessed as a function of dose and reconstruction algorithm. As part of a parallel clinical trial, images from 21 patients were collected at 6 dose levels per patient on a SOMATOM Flash scanner. Subtle liver lesion models (contrast = -15 HU) were inserted into the raw projection data from the patient scans. The projections were then reconstructed with FBP and SAFIRE (strength 5). Also, lesion-less images were reconstructed. Noise, contrast, CNR, and detectability index of an observer model (non-prewhitening matched filter) were assessed. It was found that SAFIRE reduced noise by 52%, reduced contrast by 12%, increased CNR by 87%. and increased detectability index by 65% compared to FBP. Further, a 2AFC human perception experiment was performed to assess the dose reduction potential of SAFIRE, which was found to be 22% compared to the standard of care dose.

In conclusion, this dissertation provides to the scientific community a series of new methodologies, phantoms, analysis techniques, and modeling tools that can be used to rigorously assess image quality from modern CT systems. Specifically, methods to properly evaluate iterative reconstruction have been developed and are expected to aid in the safe clinical implementation of dose reduction technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Optical coherence tomography (OCT) is a noninvasive three-dimensional interferometric imaging technique capable of achieving micrometer scale resolution. It is now a standard of care in ophthalmology, where it is used to improve the accuracy of early diagnosis, to better understand the source of pathophysiology, and to monitor disease progression and response to therapy. In particular, retinal imaging has been the most prevalent clinical application of OCT, but researchers and companies alike are developing OCT systems for cardiology, dermatology, dentistry, and many other medical and industrial applications.

Adaptive optics (AO) is a technique used to reduce monochromatic aberrations in optical instruments. It is used in astronomical telescopes, laser communications, high-power lasers, retinal imaging, optical fabrication and microscopy to improve system performance. Scanning laser ophthalmoscopy (SLO) is a noninvasive confocal imaging technique that produces high contrast two-dimensional retinal images. AO is combined with SLO (AOSLO) to compensate for the wavefront distortions caused by the optics of the eye, providing the ability to visualize the living retina with cellular resolution. AOSLO has shown great promise to advance the understanding of the etiology of retinal diseases on a cellular level.

Broadly, we endeavor to enhance the vision outcome of ophthalmic patients through improved diagnostics and personalized therapy. Toward this end, the objective of the work presented herein was the development of advanced techniques for increasing the imaging speed, reducing the form factor, and broadening the versatility of OCT and AOSLO. Despite our focus on applications in ophthalmology, the techniques developed could be applied to other medical and industrial applications. In this dissertation, a technique to quadruple the imaging speed of OCT was developed. This technique was demonstrated by imaging the retinas of healthy human subjects. A handheld, dual depth OCT system was developed. This system enabled sequential imaging of the anterior segment and retina of human eyes. Finally, handheld SLO/OCT systems were developed, culminating in the design of a handheld AOSLO system. This system has the potential to provide cellular level imaging of the human retina, resolving even the most densely packed foveal cones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Scientists planning to use underwater stereoscopic image technologies are often faced with numerous problems during the methodological implementations: commercial equipment is too expensive; the setup or calibration is too complex; or the imaging processing (i.e. measuring objects in the stereo-images) is too complicated to be performed without a time-consuming phase of training and evaluation. The present paper addresses some of these problems and describes a workflow for stereoscopic measurements for marine biologists. It also provides instructions on how to assemble an underwater stereo-photographic system with two digital consumer cameras and gives step-by-step guidelines for setting up the hardware. The second part details a software procedure to correct stereo-image pairs for lens distortions, which is especially important when using cameras with non-calibrated optical units. The final part presents a guide to the process of measuring the lengths (or distances) of objects in stereoscopic image pairs. To reveal the applicability and the restrictions of the described systems and to test the effects of different types of camera (a compact camera and an SLR type), experiments were performed to determine the precision and accuracy of two generic stereo-imaging units: a diver-operated system based on two Olympus Mju 1030SW compact cameras and a cable-connected observatory system based on two Canon 1100D SLR cameras. In the simplest setup without any correction for lens distortion, the low-budget Olympus Mju 1030SW system achieved mean accuracy errors (percentage deviation of a measurement from the object's real size) between 10.2 and -7.6% (overall mean value: -0.6%), depending on the size, orientation and distance of the measured object from the camera. With the single lens reflex (SLR) system, very similar values between 10.1% and -3.4% (overall mean value: -1.2%) were observed. Correction of the lens distortion significantly improved the mean accuracy errors of either system. Even more, system precision (spread of the accuracy) improved significantly in both systems. Neither the use of a wide-angle converter nor multiple reassembly of the system had a significant negative effect on the results. The study shows that underwater stereophotography, independent of the system, has a high potential for robust and non-destructive in situ sampling and can be used without prior specialist training.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At the University of Worcester we are continually striving to find new approaches to the learning and teaching of programming, to improve the quality of learning and the student experience. Over the past three years we have used the contexts of robotics, computer games, and most recently a study of Abstract Art to this end. This paper discusses our motivation for using Abstract Art as a context, details our principles and methodology, and reports on an evaluation of the student experience. Our basic tenet is that one can view the works of artists such as Kandinsky, Klee and Malevich as Object-Oriented (OO) constructions. Discussion of these works can therefore be used to introduce OO principles, to explore the meaning of classes, methods and attributes and finally to synthesize new works of art through Java code. This research has been conducted during delivery of an “Advanced OOP (Java)” programming module at final-year Undergraduate level, and during a Masters’ OO-Programming (Java) module. This allows a comparative evaluation of novice and experienced programmers’ learning. In this paper, we identify several instructional factors which emerge from our approach, and reflect upon the associated pedagogy. A Catalogue of ArtApplets is provided at the associated web-site.