973 resultados para Ion selective electrodes


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6) and high speed (30 readings/hour); it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite-epoxy electrode sensitive to the zinc-1,10-phenantroline complex based on the [Zn(fen)3][tetrakis(4-chlorophenyl)borate]2 incorporated into a poly(vinylchloride) (PVC) matrix are described. A thin membrane film of this ion-pair, dibutylphthalate (DBPh) and PVC were deposited directly onto an electrically conductive graphite-epoxy support located inside a Perspex® tube. The best PVC polymeric membrane contains 65% (m/m) DBPh, 30% (m/m) PVC and 5% (m/m) of the ion-pair. This electrode shows a response of 19.5 mV dec-1 over the zinc(II) concentration range of 1.0 x 10-5 to 1.0 x 10-3 mol L-1 in 1,10-phenantroline medium, at pH 6.0. The response time was less than 20 seconds and the lifetime of this electrode was more than four months (over 1200 determinations by each polymeric membrane). It was successfully used as an indicator electrode in the potentiometric precipitation titration of zinc(II) ions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The contamination level of silicon oil used as insulation liquid in high-voltage transformers by ascarel (PCBs) is above those permitted by the Brazilian law. Thus new techniques able to detect ascarel, with low operational costs, are very attractive. The present work proposes an analysis of the contamination levels of silicon oil using the following techniques: naphthalene anion radical reaction for ascarel dechlorination; and potentiometry with an ion-selective electrode for chloride ion determination. The data obtained with the proposed methodology agree well with those from the official methodology, (method IEC 61619).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Proton binding properties of humic and fulvic acids were studied by potentiometric titration. Carboxylic groups were the predominant ionizable sites in comparison to phenolic and amine groups. Total acidity of fulvic acid was 12 x 10-3 mol g-1, a number significantly higher than that obtained for humic acid (5.2 x 10-3 mol g-1). Copper ion binding was evaluated at pH 4, 5 and 6 by potentiometric titration with an ion selective electrode for Cu(II). Differential stability constants and complexation capacities were systematically higher for humic acid, despite its lower number of ionizable sites in comparison with fulvic acid.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pyrohydrolysis is proposed for fossil fuels sample preparation for further fluorine and chlorine determination. Samples were heated during 10 min at temperatures up to 1000 °C. Water vapor was passed through the reactor and the volatile products were condensed and collected in NH4OH solution. Fluoride was determined by potentiometry using an ion selective electrode (ISE) and Cl by ICP OES and DRC-ICP-MS. The results are in good agreement with certified values and the precision is better than 10% (n = 4). Sample preparation by means of pyrohydrolysis is relatively simple, whereas chlorine and fluorine can be determined at low concentrations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a quality assurance and quality control protocol in order to ensure the reliability of analytical results for the determination of acid volatile sulfides in environmental samples by potentiometry. The monitoring of the ion selective sensor readings must be realized continually and particularly in this situation where the analyte is susceptible to transformation and volatilization. Potentiometry with the standard addition was presented as a rapid, accurate, precise, feasible as well as a low cost technique. Concentrations of the analyte in the range of 0.49 to 1.02 mg L-1 were tested with percentage recoveries varying from 89 to 113%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les résultats présentés dans cette thèse précisent certains aspects de la fonction du cotransporteur Na+/glucose (SGLT1), une protéine transmembranaire qui utilise le gradient électrochimique favorable des ions Na+ afin d’accumuler le glucose à l’intérieur des cellules épithéliales de l’intestin grêle et du rein. Nous avons tout d’abord utilisé l’électrophysiologie à deux microélectrodes sur des ovocytes de xénope afin d’identifier les ions qui constituaient le courant de fuite de SGLT1, un courant mesuré en absence de glucose qui est découplé de la stoechiométrie stricte de 2 Na+/1 glucose caractérisant le cotransport. Nos résultats ont démontré que des cations comme le Li+, le K+ et le Cs+, qui n’interagissent que faiblement avec les sites de liaison de SGLT1 et ne permettent pas les conformations engendrées par la liaison du Na+, pouvaient néanmoins générer un courant de fuite d’amplitude comparable à celui mesuré en présence de Na+. Ceci suggère que le courant de fuite traverse SGLT1 en utilisant une voie de perméation différente de celle définie par les changements de conformation propres au cotransport Na+/glucose, possiblement similaire à celle empruntée par la perméabilité à l’eau passive. Dans un deuxième temps, nous avons cherché à estimer la vitesse des cycles de cotransport de SGLT1 à l’aide de la technique de la trappe ionique, selon laquelle le large bout d’une électrode sélective (~100 μm) est pressé contre la membrane plasmique d’un ovocyte et circonscrit ainsi un petit volume de solution extracellulaire que l’on nomme la trappe. Les variations de concentration ionique se produisant dans la trappe en conséquence de l’activité de SGLT1 nous ont permis de déduire que le cotransport Na+/glucose s’effectuait à un rythme d’environ 13 s-1 lorsque le potentiel membranaire était fixé à -155 mV. Suite à cela, nous nous sommes intéressés au développement d’un modèle cinétique de SGLT1. En se servant de l’algorithme du recuit simulé, nous avons construit un schéma cinétique à 7 états reproduisant de façon précise les courants du cotransporteur en fonction du Na+ et du glucose extracellulaire. Notre modèle prédit qu’en présence d’une concentration saturante de glucose, la réorientation dans la membrane de SGLT1 suivant le relâchement intracellulaire de ses substrats est l’étape qui limite la vitesse de cotransport.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effect of dietary sodium restriction on perceived intensity of and preference for the taste of salt was evaluated in 76 adults, 25-49 years, with diastolic blood pressure between 79-90 mmHg. Participants were volunteers from clinical Hypertension Prevention Trials (HPT), at the University of California, Davis and the University of Minnesota, Minneapolis. Participants followed one of four HPT diets: 1600 mg Na+/day (NA, n=lS), 1600 mg Na+ plus 3200 mg K+/day (NK, n=lS), 1600 mg Na+/day plus energy restriction to achieve weight loss (NW, n=l3) and weight loss only (WT, n=l3). All participants attended regularly scheduled nutri­tion intervention meetings designed to help them achieve the HPT dietary goals. A fifth, no-intervention group, consisted of 20, no-diet-change controls CCN). Sodium, potassium and energy intakes were monitored by analysis of single, 24-hour food records and corresponding overnight urine speci­mens, obtained at baseline and after 12 and 24 weeks of intervention. Hedonic responses to sodium chloride in a prepared cream of green bean soup were assessed by two methods : 1) scaling of like/dislike for an NaCl concentration series on 10-cm graphie line scales and 2) ad libitum mixing of unsalted and salted soups to maximum level of liking. Salt content of the mixes was analyzed by sodium ion-selective electrode. The concentration series was also rated for perceived saltiness­intensity on similar graphie line scales. Tests were conducted at base­line and after approximately 1, 3, 6, 8, 10, 13 and 24 weeks of intervention. Reduction in sodium intake and excretion in NA, NK and NW partici­pants was accompanied by a shift in preference toward less saltiness in soup. The pattern of hedonic responses changed over time: scores for high NaCl concentrations decreased progressively while scores for low concentrations increased. Hedonic maxima shifted fran a concentration of 0.55% at the onset to 0.1-0.2% added NaCl at week 24. During the same time period, the preferred concentration of ad libitum mixes declined 50%. These shifts occurred independently of changes in salti­ness intensity ratings, potassium or energy intakes, and were consistent across the two participating study sites. Like/dislike and sd. libitum responses were similar after 13 and 24 weeks of diet, as were measures of sodium intake and excretion. These findings suggest that after three months of sodium restriction, preference for salt had readjusted to a lower level, reflective of lower sodium intake. Mechanisms underlying the change in preference are unclear, but may include sensory, context, physiological as well as behavioral effects. In contrast, few changes were noted within WT and CN groups. The pattern of hedonic responses varied little in controls while the WT group showed increased liking for mid-range NaCl concentrations. Small, but significant fluctuations in ad libitum mix concentration occurred in both of these groups, but the differences appeared to be random rather than systematic. The results of this study indicate that preference for the taste of salt declines progressively toward a new baseline following reductions in sodium intake. These alterations may enhance maintenance of low­sodium diets for the treatment and prevention of hypertension. Further investigation is needed to establish the degree to which long-term com­pliance is contingent upon variation in salt taste preference.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The quality of a drug is determined after establishing its authenticity by testing its purity and quality of the pure substance in the drug and its formulations.Ion selective sensors have become one of the most effective and powerful means for analytical scientists in the determination of drug substances and are playing an increasing role in pharmaceutical analysis.ISEs are cost effective,easy to prepare and can be rapidly manipulated . Potentiometric ion selective sensors have been developed for six drugs namely trimethoprim, ketoconazole, lamivudine, domperidon, nimesulide and Lomefloxacin. The sensors fabricated include both PVC membrane sensor as well as carbon paste sensor. A total of sixteen different sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied to the determination of the drugs in pharmaceutical formulations and also in real samples like urine.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polymer supports are efficient reagents,substrates and catalysts and they are extensively used for carrying out reactions at controlled rates.Tailor-made polymer supports are highly versatile which have opened an excellent area of research.Now polymer supported chemistry is being exploited at an amazing rate and it seems to join the routine world of organic synthesis.Polymer supported ligands are found to be efficient complexing agents whose high selectivity enables the analysis and removal of heavy metal ions which are toxic to all the living organisms of land and sea.polymer supported membranes function as ion selective potentiometric sensors which allow the exchange of specific ions among other ions of the same charge.In this investigation three series of polymeric schiff bases and three series of metal complexes have been prepared.An attempt is done to develop optimum conditions for the removal of heavy metal ions using polymeric schiff bases.A novel copper sensor electrode have also been prepared from polymer supported metal complex.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As the application of polymeric complexes is enormous, there exists a continuing interest in the synthesis and characterization of these complexes. The synthetic and characterization parts are very important in an academic point of view. Further in an application point of view also polymeric ligands/complexes are gaining attention.The thesis is divided in to six chapters, in which the first chapter gives an introduction along with a brief review on polymeric ligands/ complexes. The second chapter explains the different procedure adopted for the whole work along with the details of the reagents/ instruments used. The third chapter gives a report of the detailed study regarding the synthesis and characterization of eighteen complexes. While the fourth chapter is a report of the ion removal studies using three polymeric ligands, the fifth chapter explains the development of a polymeric complex as ion selective electrode material for the fabrication of a CC ion selective electrode. The sixth chapter presents the summary and tables, figures and references are given separately at the end.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The complexation of Cu by sewage sludge-derived dissolved organic matter (SSDOM) is a process by which the environmental significance of the element may become enhanced due to reduced soil sorption and, hence, increased mobility. The work described in this paper used an ion selective electrode procedure to show that SSDOM complexation of Cu was greatest at intermediate pH values because competition between hydrogen ions and Cu for SSDOM binding sites, and between hydroxyl ions and SSDOM as Cu ligands, was lowest at such values. Batch sorption experiments further showed that the process of Cu complexation by SSDOM provided an explanation for enhanced desorption of Cu from the solid phase of a contaminated, organic matter-rich, clay loam soil, and reduced adsorption of Cu onto the solid phase of a sandy loam soil. Complexation of Cu by SSDOM did not affect uptake of Cu by spring barley plants, when compared to free ionic Cu, in a sand-culture pot experiment. However, it did appear to lead to greater biomass yields of the plant; perhaps indicating that the Cu-SSDOM complex had a lower toxicity towards the plant than the free Cu ion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the last decade, there has been renewed interest in biologically active peptides in fields like allergy, autoimmume diseases and antibiotic therapy. Mast cell degranulating peptides mimic G-protein receptors, showing different activity levels even among homologous peptides. Another important feature is their ability to interact directly with membrane phospholipids, in a fast and concentration-dependent way. The mechanism of action of peptide HR1 on model membranes was investigated comparatively to other mast cell degranulating peptides (Mastoparan, Eumenitin and Anoplin) to evidence the features that modulate their selectivity. Using vesicle leakage, single-channel recordings and zeta-potential measurements, we demonstrated that HR1 preferentially binds to anionic bilayers, accumulates, folds, and at very low concentrations, is able to insert and create membrane spanning ion-selective pores. We discuss the ion selectivity character of the pores based on the neutralization or screening of the peptides charges by the bilayer head group charges or dipoles. (C) 2009 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The batch-operated bromate/phosphate/acetone/dual catalyst system was studied at four temperatures between 5 and 35 degrees C. The dynamics was simultaneously followed by potential measurements with platinum and bromide selective electrodes, and spectroscopically at two different wavelengths. By simultaneously recording these four time series it was possible to characterize the dynamics of the sequential oscillations that evolve in time. The existence of three sequential oscillatory patterns at each temperature allowed estimating the activation energies in each case. Along with the activation energy of the induction period, it was possible to trace the time evolution of the overall activation energy at four different stages as the reaction proceeds. The study was carried out for two different sets of initial concentrations and it was observed that the overall activation energy increases as reactants turn into products. This finding was propounded as a result of the decrease in the driving force, or the system`s affinity, of the catalytic oxidative bromination of acetone with acidic bromate, as the closed system evolves toward the thermodynamic equilibrium.