953 resultados para Intra-ocular pressure


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Arthrocentesis, injection and infiltration of joints and soft tissues belong to the basic procedures in rheumatology. The indications and the practical performance are based on experience and tradition. Nowadays, a crucial reappraisal and adaption of indications and technical aspects appear important in the light of new evidence and technical developments. The main indications for puncture remain the search of an infectious arthritis and reduction of intra-articular pressure due to effusion. Good indications for the injection of glucocorticoids are inflammation in sterile joints and activated osteoarthritis. The local infiltration with corticosteroids in mechanically induced enthesopathies at the lateral epicondyle of the humerus or at the plantar fascia have to be questioned in the light of recent publications which show that this common practice is associated with a poorer outcome than without injection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Spontaneous pneumomediastinum commonly occurs in healthy young men or parturient women in whom an increased intra-alveolar pressure (Valsalva maneuver, asthma, cough, emesis) leads to the rupture of the marginal pulmonary alveoli. The air ascends along the bronchi to the mediastinum and the subcutaneous space of the neck, causing cervico-fascial subcutaneous emphysema in 70-90% of cases. Ninety-five forensic cases, including five cases of hanging, were examined using postmortem multi-slice computed tomography (MSCT) and magnetic resonance imaging (MRI) prior to autopsy until December 2003. This paper describes the findings of pneumomediastinum and cervical emphysema in three of five cases of hanging. The mechanism of its formation is discussed based on these results and a review of the literature. In conclusion, when putrefaction gas can be excluded the findings of pneumomediastinum and cervical soft tissue emphysema serve as evidence of vitality of a hanged person. Postmortem cross-sectional imaging is considered a useful visualization tool for emphysema, with a great potential for examination and documentation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The pelvic floor muscles (PFM) are part of the trunk stability mechanism. Their function is interdependent with other muscles of this system. They also contribute to continence, elimination, sexual arousal and intra-abdominal pressure. This paper outlines some aspects of function and dysfunction of the PFM complex and describes the contribution of other trunk muscles to these processes. Muscle pathophysiology of stress urinary incontinence (SUI) is described in detail. The innovative rehabilitation programme for SUI presented here utilizes abdominal muscle action to initiate tonic PFM activity. Abdominal muscle activity is then used in PFM strengthening, motor relearning for functional expiratory actions and finally impact training. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis is concerned with the design and synthesis of a novel, injectable proteoglycan analogue for tissue repair. This is of particular relevance to the restoration of disc height to a degraded nucleus pulposus of the intervertebral disc. The focus is on the use of sulfonate monomers as proteoglycan analogues, in particular sodium 2-acrylamido-2-methylpropane sulfonic acid and the potassium salt of 3-sulfopropyl acrylate. For most biomedical applications, synthetic hydrogels need to show dimensional stability to changes in pH, osmolarity, and temperature. This is readily achieved by neutral structures however ionic sulfonate containing hydrogels are responsive to environmental change which renders them difficult to manage in most tissue replacement applications. In this case osmotic responsiveness rather than stability is desirable. Therefore sulfonate based materials possess advantageous properties. This is a result of the sulfonate becoming an ideal surrogate for the sulfate group present within the structure of natural proteoglycans. This thesis reports polymerisation studies based on the production of a redox initiated copolymer system capable of polymerising in situ within a timescale of circa. 5-7 minutes. The rheological properties, osmotic drive, and residual monomer content of successful compositions is analysed. Properties are adapted to mimic those of the target natural tissue. The adaptation of the material for use as an injectable intra-ocular lens, with hyaluronic acid as an interpenetrate is reported. The synthesis of a radiopaque macromer to allow visibility of the repair system once in situ is investigated and discussed. The results presented in this thesis describe a suitable proteoglycan tissue analogue which is injectable, biomimetic, osmotically responsive and mechanically stable in its desired application.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: A clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500 (Japan) was performed to evaluate validity and repeatability compared with non-cycloplegic subjective refraction and Javal–Schiotz keratometry. An investigation into the dynamic recording capabilities of the instrument was also conducted. Methods: Refractive error measurements were obtained from 150 eyes of 75 subjects (aged 25.12 ± 9.03 years), subjectively by a masked optometrist, and objectively with the WAM-5500 at a second session. Keratometry measurements from the WAM-5500 were compared to Javal–Schiotz readings. Intratest variability was examined on all subjects, whilst intertest variability was assessed on a subgroup of 44 eyes 7–14 days after the initial objective measures. The accuracy of the dynamic recording mode of the instrument and its tolerance to longitudinal movement was evaluated using a model eye. An additional evaluation of the dynamic mode was performed using a human eye in relaxed and accommodated states. Results: Refractive error determined by the WAM-5500 was found to be very similar (p = 0.77) to subjective refraction (difference, -0.01 ± 0.38 D). The instrument was accurate and reliable over a wide range of refractive errors (-6.38 to +4.88 D). WAM-5500 keratometry values were steeper by approximately 0.05 mm in both the vertical and horizontal meridians. High intertest repeatability was demonstrated for all parameters measured: for sphere, cylinder power and MSE, over 90% of retest values fell within ±0.50 D of initial testing. In dynamic (high-speed) mode, the root-mean-square of the fluctuations was 0.005 ± 0.0005 D and a high level of recording accuracy was maintained when the measurement ring was significantly blurred by longitudinal movement of the instrument head. Conclusion: The WAM-5500 Auto Ref/Keratometer represents a reliable and valid objective refraction tool for general optometric practice, with important additional features allowing pupil size determination and easy conversion into high-speed mode, increasing its usefulness post-surgically following accommodating intra-ocular lens implantation, and as a research tool in the study of accommodation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Summarised retinal vessel diameters are linked to systemic vascular pathology. Monochromatic images provide best contrast to measure vessel calibres. However, when obtaining images with a dual wavelength oximeter the red-free image can be extracted as the green channel information only which in turn will reduce the number of photographs taken at a given time. This will reduce patient exposure to the camera flash and could provide sufficient quality images to reliably measure vessel calibres. Methods: We obtained retinal images of one eye of 45 healthy participants. Central retinal arteriolar and central retinal venular equivalents (CRAE and CRVE, respectively) were measured using semi-automated software from two monochromatic images: one taken with a red-free filter and one extracted from the green channel of a dual wavelength oximetry image. Results: Participants were aged between 21 and 62 years, all were normotensive (SBP: 115 (12) mmHg; DBP: 72 (10) mmHg) and had normal intra-ocular pressures (12 (3) mmHg). Bland-Altman analysis revealed good agreement of CRAE and CRVE as obtained from both images (mean bias CRAE = 0.88; CRVE = 2.82). Conclusions: Summarised retinal vessel calibre measurements obtained from oximetry images are in good agreement to those obtained using red-free photographs.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Despite the high incidence of abdominal traumas, traumatic abdominal wall hernias (TAWHs) remain rare probably because of elasticity of the abdominal wall. The TAWH is due to blunt abdominal trauma with disruption of the abdominal wall muscles and fascia with intact overlying skin. TAWH can be classified into high energy injures (generally motor vehicle accidents) and low energy injures (impact on a small blunt object). Common example of the latter type is a fall onto a bicycle handlebar. The mechanism of the trauma includes sudden increase of intra-abdominal pressure and extensive shear forces applied to the abdominal wall. The diagnosis of TAWH is difficult in the Emergency Room because during the primary diagnostic process most attention is directed toward the detection of internal injures and TAWH can be missed. In this article we report a case of TAWH caused by a work accident (an heavy steel tube fallen onto the abdominal wall of the patient from a height of five meters) with delayed diagnosis.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Introdução: A catarata em idade pediátrica constitui um desafio cirúrgico. Este desafio assume maior dimensão quando a catarata pediátrica é secundária ao tratamento com radioterapia por tumor ocular. A complexidade da técnica, a maior fragilidade ou fibrose de estruturas oculares e o maior risco de complicações intra e pós operatórias são obstáculos que o cirurgião deve equacionar. Os autores apresentam um caso clinico de uma cirurgia de catarata unilateral, secundária a radiação por feixe de protões externo para tratamento de melanoma da íris, em criança com 11 anos de idade. Métodos: Criança de 8 anos, com lesão pigmentada infero-temporal no olho esquerdo. Estabeleceu-se o diagnóstico de melanoma da íris, tendo realizado radioterapia com feixe acelerado de protões com excisão e recolocação de células limbares. Após 18 meses de radioterapia, constatou-se desenvolvimento de catarata subcapsular posterior com evolução para catarata branca. Aos 11 anos, foi submetida, sob anestesia geral, a facoemulsificação microincisional. Realizaram-se 2 paracenteses de 1 mm e, através destas, efectuou-se a capsulorexis anterior, após coloração com azul tripano. Procedeu-se à realização da incisão principal (2,2mm), à faco-aspiração do cristalino opacificado e à irrigação/aspiração bimanual do córtex. Implantou-se a lente intra-ocular monobloco monofocal (SN 60WF) no saco capsular e efectuou-se capsulorexis posterior primária. Com o objectivo de excluir a presença de vítreo na câmara anterior e simultaneamente obter um efeito anti-inflamatório, injectou-se intra-camerularmente triamcinolona sem conservantes. Resultados: Não se observaram complicações intra ou pós-operatórias, imediatas ou tardias, de relevo. Com 1 ano de evolução, a acuidade visual do olho esquerdo é de 10/10. Após 4 anos de radioterapia não se observa recorrência do tumor, doença metastática nem complicações da radioterapia. Conclusões: A micro-incisão, a capsulorexis posterior primária e a aplicação de triamcinolona intracamerular asseguram maior segurança no procedimento, mais rápida recuperação visual com transparência duradoura do eixo visual e menor inflamação no pós-operatório.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims: To investigate the change that occurs in intraocular pressure (IOP) and ocular pulse amplitude (OPA) with accommodation in young adult myopes and emmetropes. Methods: Fifteen progressing myopic and 17 emmetropic young adult subjects had their IOP and OPA measured using the Pascal dynamic contour tonometer. Measurements were taken initially with accommodation relaxed, and then following 2 min of near fixation (accommodative demand 3 D). Baseline measurements of axial length and corneal thickness were also collected prior to the IOP measures. Results: IOP significantly decreased with accommodation in both the myopic and emmetropic subjects (mean change 1.861.1 mm Hg, p<0.0001). There was no significant difference (p>0.05) between myopes and emmetropes in terms of baseline IOP or the magnitude of change in IOP with accommodation. OPA also decreased significantly with accommodation (mean change for all subjects 0.560.5, p<0.0001). The myopic subjects (baseline OPA 2.060.7 mm Hg) exhibited a significantly lower baseline OPA (p¼0.004) than the emmetropes (baseline OPA 3.261.3 mm Hg),and a significantly lower magnitude of change in OPA with accommodation. Conclusion: IOP decreases significantly with accommodation, and changes similarly in progressing myopic and emmetropic subjects. However, differences found between progressing myopes and emmetropes in the mean OPA levels and the decrease in OPA associated with accommodation suggested some changes in IOP dynamics associated with myopia.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AIM To assess the effects of eye rubbing on corneal thickness (CT) and intraocular pressure (IOP) measurements obtained 0-30min after habitual eye rubbing in symptomatic patients. METHODS Measurements of IOP and CT were obtained at five locations (central, temporal, superior, nasal and inferior) before, and every 5min for 30min interval after 30s of eye rubbing, for 25 randomly selected eyes of 14 subjects with ocular allergy and 11 age-matched normals. Differences in measurements were calculated in each group [Baseline measurements minus measurements recorded at each time interval after eye rubbing (for IOP), and for each corneal location (for CT)] and comparison were then made between groups (allergic versus control) for differences in any observed effects. RESULTS Within groups, baseline mean IOPs in the allergic patient-group (14.2±3.0 mm Hg) and in the control group (13.1±1.9 mm Hg) were similar at all times, after eye rubbing (P >0.05, for all). The maximum reduction in IOP was 0.8 mm Hg in the control subjects and the maximum increase was also 0.8 mm Hg in the allergic subjects. Between groups (allergic versus control), the changes in IOP remained under 1 mm Hg at all times (P=0.2) after 30min of eye rubbing. Between 0 and 30min of CT measurements after eye rubbing, the mean central CT (CCT), inferior CT (ICT), superior CT (SCT), temporal CT (TCT) and nasal CT (NCT) did not vary significantly from baseline values in the control and allergic-subject groups (P>0.05, for both). Between both groups, changes in CT were similar at all locations (P>0.05) except for the TC which was minimally thinner by about 4.4 µm (P=0.001) in the allergic subjects than in the control subjects, 30min following 30s of eye rubbing. CONCLUSION IOP measured in allergic subjects after 30s of habitual eye rubbing was comparable with that obtained in normal subjects at all times between 0 and 30min. Although, CT in the allergic subjects were similar to those of the control subjects at all times, it varied between +10 and -7.5 µm following eye rubbing, with the temporal cornea showing consistent reductions in thickness in the subjects with allergy. However, this reduction was minimal and was considered to not be clinically relevant.