934 resultados para Indoor shoe
Resumo:
PURPOSE: The aim of this study was to develop models based on kernel regression and probability estimation in order to predict and map IRC in Switzerland by taking into account all of the following: architectural factors, spatial relationships between the measurements, as well as geological information. METHODS: We looked at about 240,000 IRC measurements carried out in about 150,000 houses. As predictor variables we included: building type, foundation type, year of construction, detector type, geographical coordinates, altitude, temperature and lithology into the kernel estimation models. We developed predictive maps as well as a map of the local probability to exceed 300 Bq/m(3). Additionally, we developed a map of a confidence index in order to estimate the reliability of the probability map. RESULTS: Our models were able to explain 28% of the variations of IRC data. All variables added information to the model. The model estimation revealed a bandwidth for each variable, making it possible to characterize the influence of each variable on the IRC estimation. Furthermore, we assessed the mapping characteristics of kernel estimation overall as well as by municipality. Overall, our model reproduces spatial IRC patterns which were already obtained earlier. On the municipal level, we could show that our model accounts well for IRC trends within municipal boundaries. Finally, we found that different building characteristics result in different IRC maps. Maps corresponding to detached houses with concrete foundations indicate systematically smaller IRC than maps corresponding to farms with earth foundation. CONCLUSIONS: IRC mapping based on kernel estimation is a powerful tool to predict and analyze IRC on a large-scale as well as on a local level. This approach enables to develop tailor-made maps for different architectural elements and measurement conditions and to account at the same time for geological information and spatial relations between IRC measurements.
Resumo:
Nicotine in a smoky indoor air environment can be determined using graphitized carbon black as a solid sorbent in quartz tubes. The temperature stability, high purity, and heat absorption characteristics of the sorbent, as well as the permeability of the quartz tubes to microwaves, enable the thermal desorption by means of microwaves after active sampling. Permeation and dynamic dilution procedures for the generation of nicotine in the vapor phase at low and high concentrations are used to evaluate the performances of the sampler. Tube preparation is described and the microwave desorption temperature is measured. Breakthrough volume is determined to allow sampling at 0.1-1 L/min for definite periods of time. The procedure is tested for the determination of gas and paticulate phase nicotine in sidestream smoke produced in an experimental chamber.
Resumo:
Location information is becoming increasingly necessary as every new smartphone incorporates a GPS (Global Positioning System) which allows the development of various applications based on it. However, it is not possible to properly receive the GPS signal in indoor environments. For this reason, new indoor positioning systems are being developed.As indoors is a very challenging scenario, it is necessary to study the precision of the obtained location information in order to determine if these new positioning techniques are suitable for indoor positioning.
Resumo:
Au printemps 2012, des employés administratifs, ayant récemment emménagé dans un nouveau bâtiment à hautes performances énergétiques, se plaignent de problèmes de santé et de gênes compatibles avec un syndrome du bâtiment malsain. L'employeur a entendu les plaintes des collaborateurs, et choisit une intervention unique, consistant à poser des ouvrants afin de fournir une ventilation naturelle. Parallèlement, il commande à des spécialistes MSST une étude sur l'impact de la mesure sur les plaintes exprimées par les employés. La littérature recommande quant à elle de prendre en charge ce type de problématique de façon itérative, et en abordant de multiples aspects (qualité de l'air, psycho-sociaux, organisationnels). Au vu des nombreuses plaintes de la population, et de la disponibilité de ces données, une analyse détaillée, de cohorte, est proposée dans ce travail de master, dont les objectifs seront de caractériser les plaintes des collaborateurs travaillant dans le bâtiment administratif, de diagnostiquer le type de problématique présent, de déterminer si l'on observe une atténuation des symptômes dans ce bâtiment suite à l'intervention unique de pose des ouvrants, et d'isoler si possible d'autres déterminants d'une évolution favorable ou défavorable de la symptomatologie en présence d'une intervention unique. Une étude de cohorte est menée sur les données récoltées par un questionnaire, basé sur le questionnaire MM40, en mars 2012 (T0) et mars 2013 (T1). La population est décrite, puis des analyses descriptives et par régression logistique sont réalisées. La participation a été importante. Entre T0 et T1, après la pose des ouvrants, le nombre de plaintes et symptômes a diminué, mais la prévalence des plaintes reste importante (odeurs, ventilation, bruit, etc.). Les plaintes et les symptômes mis en évidence sont retrouvés dans la littérature, et sont peu spécifiques à la problématique de ce bâtiment, situé en Suisse. De nouvelles pistes d'intervention sont proposées au vu des résultats trouvés.
Resumo:
Location information is becoming increasingly necessary as every new smartphone incorporates a GPS (Global Positioning System) which allows the development of various applications based on it. However, it is not possible to properly receive the GPS signal in indoor environments. For this reason, new indoor positioning systems are being developed. As indoors is a very challenging scenario, it is necessary to study the precision of the obtained location information in order to determine if these new positioning techniques are suitable for indoor positioning.
Resumo:
PURPOSE: According to estimations around 230 people die as a result of radon exposure in Switzerland. This public health concern makes reliable indoor radon prediction and mapping methods necessary in order to improve risk communication to the public. The aim of this study was to develop an automated method to classify lithological units according to their radon characteristics and to develop mapping and predictive tools in order to improve local radon prediction. METHOD: About 240 000 indoor radon concentration (IRC) measurements in about 150 000 buildings were available for our analysis. The automated classification of lithological units was based on k-medoids clustering via pair-wise Kolmogorov distances between IRC distributions of lithological units. For IRC mapping and prediction we used random forests and Bayesian additive regression trees (BART). RESULTS: The automated classification groups lithological units well in terms of their IRC characteristics. Especially the IRC differences in metamorphic rocks like gneiss are well revealed by this method. The maps produced by random forests soundly represent the regional difference of IRCs in Switzerland and improve the spatial detail compared to existing approaches. We could explain 33% of the variations in IRC data with random forests. Additionally, the influence of a variable evaluated by random forests shows that building characteristics are less important predictors for IRCs than spatial/geological influences. BART could explain 29% of IRC variability and produced maps that indicate the prediction uncertainty. CONCLUSION: Ensemble regression trees are a powerful tool to model and understand the multidimensional influences on IRCs. Automatic clustering of lithological units complements this method by facilitating the interpretation of radon properties of rock types. This study provides an important element for radon risk communication. Future approaches should consider taking into account further variables like soil gas radon measurements as well as more detailed geological information.
Resumo:
Simultaneous measurements of outdoor and indoor pollution were performed at three schools in Lisbon. Volatile organic compounds (VOCs), formaldehyde and NO2 were passively monitored over a two-week period. Bacterial and fungal colony-forming units and comfort parameters were also monitored at classrooms and playgrounds. The highest indoor levels of CO2 (2666 μg/m³), NO2 (40.3 μg/m³), VOCs (10.3 μg/m³), formaldehyde (1.03 μg/m³) and bioaerosols (1634 CFU/m³), and some indoor/outdoor ratios greater than unity, suggest that indoor sources and building conditions might have negative effects on air indoors. Increasing ventilation rates and use of low-emission materials would contribute towards improving indoor air quality.
Resumo:
Atmospheric pollutants can have serious impacts on the preservation of São Paulo's tangible cultural heritage. The purpose of this paper is to report the results of a monitoring campaign focussed on particulate matter (PM) that was conducted in three of the most important museums of the São Paulo megacity (Brazil): the Museu de Arqueologia e Etnologia (MAE-USP), the Museu Paulista (MP-USP), and the Pinacoteca do Estado de São Paulo (PE). These museums exhibit indoor PM and black carbon (BC) concentrations consistent with their urban locations and their specific methods for managing the indoor environment.
Resumo:
Optimointi on tavallinen toimenpide esimerkiksi prosessin muuttamisen tai uusimisen jälkeen. Optimoinnilla pyritään etsimään vaikkapa tiettyjen laatuominaisuuksien kannalta paras tapa ajaa prosessia tai erinäisiä prosessin osia. Tämän työn tarkoituksena oli investoinnin jälkeen optimoida neljä muuttujaa, erään runkoon menevän massan jauhatus ja määrä, märkäpuristus sekä spray –tärkin määrä, kolmen laatuominaisuuden, palstautumislujuuden, geometrisen taivutusjäykkyyden ja sileyden, suhteen. Työtä varten tehtiin viisi tehdasmittakaavaista koeajoa. Ensimmäisessä koeajossa oli tarkoitus lisätä vettä tai spray –tärkkiä kolmikerroskartongin toiseen kerrosten rajapintaan, toisessa koeajossa muutettiin, jo aiemmin mainitun runkoon menevän massan jauhatusta ja jauhinkombinaatioita. Ensimmäisessä koeajossa tutkittiin palstautumislujuuden, toisessa koeajossa muiden lujuusominaisuuksien kehittymistä. Kolmannessa koeajossa tutkittiin erään runkoon menevän massan jauhatuksen ja määrän sekä kenkäpuristimen viivapaineen muutoksen vaikutusta palstautumislujuuteen, geometriseen taivutusjäykkyyteen sekä sileyteen. Neljännessä koeajossa yritettiin toistaa edellisen koeajon paras piste ja parametreja hieman muuttamalla saada aikaan vieläkin paremmat laatuominaisuudet. Myös tässä kokeessa tutkittiin muuttujien vaikutusta palstautumislujuuteen, geometriseen taivutusjäykkyyteen ja sileyteen. Viimeisen kokeen tarkoituksena oli tutkia samaisen runkoon menevän massan vähentämisen vaikutusta palstautumislujuuteen. Erinäisistä vastoinkäymisistä johtuen, koeajoista saadut tulokset jäivät melko laihoiksi. Kokeista kävi kuitenkin ilmi, että lujuusominaisuudet eivät parantuneet, vaikka jauhatusta jatkettiin. Lujuusominaisuuksien kehittymisen kannalta turha jauhatus pystyttiin siis jättämään pois ja näin säästämään energiaa sekä säästymään pitkälle viedyn jauhatuksen mahdollisesti aiheuttamilta muilta ongelmilta. Vähemmällä jauhatuksella ominaissärmäkuorma saatiin myös pidettyä alle tehtaalla halutun tason. Puuttuvat lujuusominaisuudet täytyy saavuttaa muilla keinoin.
Resumo:
In this report are described means for indoor localization in special, challenging circum-stances in marine industry. The work has been carried out in MARIN project, where a tool based on mobile augmented reality technologies for marine industry is developed. The tool can be used for various inspection and documentation tasks and it is aimed for improving the efficiency in design and construction work by offering the possibility to visualize the newest 3D-CAD model in real environment. Indoor localization is needed to support the system in initialization of the accurate camera pose calculation and auto-matically finding the right location in the 3D-CAD model. The suitability of each indoor localization method to the specific environment and circumstances is evaluated.
Resumo:
Waste has been incinerated for energy utilization for more than a hundred years, but the harmful emissions emitted from the incineration plants did not begin to cause concern until the 1980s. Many plants were shutdown and the waste incineration plant in Kyläsaari Helsinki was one of them. In later years, new landfill regulations have increased the interest in waste incineration. During the last year, four new plants were taken into operation in Finland, Westenergy in Vaasa among them. The presence of dust has been observed indoors at Westenergy waste incineration plant. Dust is defined as particles with a diameter above 10 μm, while fine particles have a diameter smaller than 2.5 μm, ultrafine under 0.1 μm and nanoparticles under 0.05 μm. In recent years, the focus of particle health research has been changed to investigate smaller particles. Ultrafine particles have been found to be more detrimental to health than larger particles. Limit values regulating the concentrations of ultrafine particles have not been determined yet. The objective of this thesis was to investigate dust and particles present inside the Westenergy waste incineration facility. The task was to investigate the potential pollutant sources and to give recommendations of how to minimize the presence of dust and particles in the power plant. The total particle number concentrations and size distributions where measured at 15 points inside the plant with an Engine Exhaust Particle Sizer (EEPS) Spectrometer. The measured particles were mainly in the ultrafine size range. Dust was only visually investigated, since the main purpose was to follow the dust accumulation. The measurement points inside the incineration plant were chosen according to investigate exposure to visitors and workers. At some points probable leakage of emissions were investigated. The measurements were carried out during approximately one month in March–April 2013. The results of the measurements showed that elevated levels of dust and particles are present in the indoor air at the waste incineration plant. The cleanest air was found in the control room, warehouse and office. The most polluted air was near the sources that were investigated due to possible leakage and in the bottom ash hall. However, the concentrations were near measured background concentrations in European cities and no leakage could be detected. The high concentrations were assumed to be a result of a lot of dust and particles present on surfaces that had not been cleaned in a while. The main source of the dust and particles present inside the waste incineration plant was thought to be particles and dust from the outside air. Other activities in the area around the waste incineration facility are ground work activities, stone crushing and traffic, which probably are sources of particle formation. Filtration of the outside air prior entering the facility would probably save personnel and visitors from nuisance and save in cleaning and maintenance costs.
Resumo:
Studies of cooking-generated NO2 effects are rare in occupational epidemiology. In the present study, we evaluated the lung function of professional cooks exposed to NO2 in hospital kitchens. We performed spirometry in 37 cooks working in four hospital kitchens and estimated the predicted FVC, FEV1 and FEF25-75, based on age, sex, race, weight, and height, according to Knudson standards. NO2 measurements were obtained for 4 consecutive days during 4 different periods at 20-day intervals in each kitchen. Measurements were performed inside and outside the kitchens, simultaneously using Palm diffusion tubes. A time/exposure indicator was defined as representative of the cumulative exposure of each cook. No statistically significant effect of NO2 exposure on FVC was found. Each year of work as a cook corresponded to a decrease in predicted FEV1 of 2.5% (P = 0.046) for the group as a whole. When smoking status and asthma were included in the analysis the effect of time/exposure decreased about 10% and lost statistical significance. On predicted FEF25-75, a decrease of 3.5% (P = 0.035) was observed for the same group and the inclusion of controllers for smoking status and asthma did not affect the effects of time/exposure on pulmonary function parameter. After a 10-year period of work as cooks the participants of the study may present decreases in both predicted FEV1 and FEF25-75 that can reach 20 and 30%, respectively. The present study showed small but statistically significant adverse effects of gas stove exposure on the lung function of professional cooks.