988 resultados para Imaging system


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effect of radiotherapy on the radiopacity and flexural strength of composite resin. Forty Z250 composite resin specimens were polymerized using a halogen light-curing unit and divided into 5 groups, in accordance with the radiotherapy dose: G1- without irradiation, G2- 30 Gy, G3- 40 Gy, G4- 50 Gy and GS- 60 Gy Digital images were obtained using a GE 100 X-ray. Radiopacity values were obtained with the Digora digital imaging system and the flexural strength was evaluated with an EMIC universal testing machine. Data were submitted to ANOVA and Tukey 's test. G1 presented the highest radiopacity value, followed by G3, G5, G4 and G2. For flexural strength, G1 presented the lowest value, followed by G2, G5, G3 and G4. Differences were no significant (p>0.05). The commonly used dosage of radiotherapy treatment, did not cause alteration in the radiopacity and flexural strength of resin-based composites.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: This in vitro study evaluated the accuracy of primary incisor lengths determined by digital and conventional radiography compared to the actual tooth length. Methods: Twenty extracted primary maxillary incisors were mounted in acrylic blocks. Tooth length was estimated by using a straight-line measurement provided by the distance measurement tool of a digital dental imaging system (Computed Dental Radiography, Schick Technologies Inc.) and conventional E-speed film radiographs by using a digital caliper. Two operators familiar with both radiographic methods performed the estimates. The estimated tooth lengths were compared to the actual tooth lengths measured with the digital caliper. Data were statistically analyzed by Dahlberg's equation, paired t test, Pearson's correlation coefficient and ANOVA at 5% significance level. Results: There were no statistically significant differences (p = 0.85) between tooth length estimated on digital and conventional radiographs. Admitting as clinically acceptable a 0.5-mm discrepancy between the actual tooth lengths and the radiographically estimated lengths, 60% of the radiographic measurements were considered as accurate. When the acceptable difference range was 1.0 mm, the accuracy of the radiographic measurements increased to 100%. Conclusions: Digital and conventional radiography provided similar tooth length measurements and were equivalent to the actual tooth lengths.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

NEWEST (Neoadjuvant Endocrine Therapy for Women with Estrogen-Sensitive Tumors) is the first study to compare biological and clinical activity of fulvestrant 500 versus 250 mg in the neoadjuvant breast cancer setting. We hypothesized that fulvestrant 500 mg may be superior to 250 mg in blocking estrogen receptor (ER) signaling and growth. A multicenter, randomized, open-label, Phase II study was performed to compare fulvestrant 500 mg (500 mg/month plus 500 mg on day 14 of month 1) versus fulvestrant 250 mg/month for 16 weeks prior to surgery in postmenopausal women with ER+ locally advanced breast cancer. Core biopsies at baseline, week 4, and surgery were assessed for biomarker changes. Primary endpoint: change in Ki67 labeling index (LI) from baseline to week 4 determined by automated computer imaging system (ACIS). Secondary endpoints: ER protein expression and function; progesterone receptor (PgR) expression; tumor response; tolerability. ER and PgR were examined retrospectively using the H score method. A total of 211 patients were randomized (fulvestrant 500 mg: n = 109; 250 mg: n = 102). At week 4, fulvestrant 500 mg resulted in greater reduction of Ki67 LI and ER expression versus 250 mg (-78.8 vs. -47.4% [p < 0.0001] and -25.0 vs. -13.5% [p = 0.0002], respectively [ACIS]); PgR suppression was not significantly different (-22.7 vs. -17.6; p = 0.5677). However, H score detected even greater suppression of ER (-50.3 vs. -13.7%; p < 0.0001) and greater PgR suppression (-80.5 vs. -46.3%; p = 0.0018) for fulvestrant 500 versus 250 mg. At week 16, tumor response rates were 22.9 and 20.6% for fulvestrant 500 and 250 mg, respectively, with considerable decline in all markers by both ACIS and H score. No detrimental effects on endometrial thickness or bone markers and no new safety concerns were identified. This provides the first evidence of greater biological activity for fulvestrant 500 versus 250 mg in depleting ER expression, function, and growth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O presente trabalho foi conduzido com o objetivo de verificar a eficiência do sistema computadorizado de avaliação do vigor de sementes (SVIS®), em comparação com outros procedimentos disponíveis, em sementes de milho superdoce. Foram utilizadas sementes dos híbridos SWB 551 e SWB 585, cada uma representada por cinco lotes, conduzindo-se testes de germinação, envelhecimento acelerado (tradicional e com solução saturada de NaCl) e emergência de plântulas em campo. Para a determinação do vigor das sementes por meio do SVIS®, as plântulas foram avaliadas aos três dias após a semeadura do teste de germinação, sendo obtidos dados referentes ao índice de vigor, à uniformidade de desenvolvimento e ao comprimento de plântulas. Para ambos os híbridos avaliados, os resultados fornecidos pelo SVIS® foram coerentes com os do teste de envelhecimento acelerado tradicional. Concluiu-se que o SVIS® é eficiente para avaliação do vigor de sementes de milho superdoce, constituindo alternativa viável para a determinação do potencial fisiológico.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die medizinische Forschung hat gezeigt, daß die frühzeitigeErkennung des Brustkrebses die Heilungschancen entscheidendverbessert. Die vorliegende Arbeit befaßt sich mit demVersuch, dieses Vorhaben durch die elektrischeImpedanztomographie zu realisieren. Dazu werden an der BrustElektroden angebracht, über die Strom in die Brust fließt.Zu verschiedenen Stromkonfigurationen werden die jeweilsresultierenden Potentialverteilungen gemessen, wasRückschlüsse auf die Leitfähigkeitsverteilung zuläßt. Tumorelassen sich somit aufgrund ihrer im Vergleich zu normalemGewebe anderen elektrischen Eigenschaften lokalisieren. Diese Dissertation beschreibt verschiedene in der Praxisdenkbare Vorgehensweisen. Das Problem wird in zwei und indrei Dimensionen mit ein oder mehreren Stromkonfigurationen untersucht. Im zweidimensionalen Fall werden Schnittbildervon Objekten in einem Versuchstank mit realistischenMeßdaten berechnet. Alle Untersuchungen in drei Dimensionenbeziehen sich auf künstlich generierte Daten. Ein weiterer Schwerpunkt der Arbeit liegt in der Bestimmungdes Stromflusses durch Elektroden in drei Dimensionen. DieKenntnis dieser Stromdichten ist für eine präzise Behandlungdes Vorwärtsproblems von großer Bedeutung.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This thesis proposes design methods and test tools, for optical systems, which may be used in an industrial environment, where not only precision and reliability but also ease of use is important. The approach to the problem has been conceived to be as general as possible, although in the present work, the design of a portable device for automatic identification applications has been studied, because this doctorate has been funded by Datalogic Scanning Group s.r.l., a world-class producer of barcode readers. The main functional components of the complete device are: electro-optical imaging, illumination and pattern generator systems. For what concerns the electro-optical imaging system, a characterization tool and an analysis one has been developed to check if the desired performance of the system has been achieved. Moreover, two design tools for optimizing the imaging system have been implemented. The first optimizes just the core of the system, the optical part, improving its performance ignoring all other contributions and generating a good starting point for the optimization of the whole complex system. The second tool optimizes the system taking into account its behavior with a model as near as possible to reality including optics, electronics and detection. For what concerns the illumination and the pattern generator systems, two tools have been implemented. The first allows the design of free-form lenses described by an arbitrary analytical function exited by an incoherent source and is able to provide custom illumination conditions for all kind of applications. The second tool consists of a new method to design Diffractive Optical Elements excited by a coherent source for large pattern angles using the Iterative Fourier Transform Algorithm. Validation of the design tools has been obtained, whenever possible, comparing the performance of the designed systems with those of fabricated prototypes. In other cases simulations have been used.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recent developments in the theory of plasma-based collisionally excited x-ray lasers (XRL) have shown an optimization potential based on the dependence of the absorption region of the pumping laser on its angle of incidence on the plasma. For the experimental proof of this idea, a number of diagnostic schemes were developed, tested, qualified and applied. A high-resolution imaging system, yielding the keV emission profile perpendicular to the target surface, provided positions of the hottest plasma regions, interesting for the benchmarking of plasma simulation codes. The implementation of a highly efficient spectrometer for the plasma emission made it possible to gain information about the abundance of the ionization states necessary for the laser action in the plasma. The intensity distribution and deflection angle of the pump laser beam could be imaged for single XRL shots, giving access to its refraction process within the plasma. During a European collaboration campaign at the Lund Laser Center, Sweden, the optimization of the pumping laser incidence angle resulted in a reduction of the required pumping energy for a Ni-like Mo XRL, which enabled the operation at a repetition rate of 10 Hz. Using the experiences gained there, the XRL performance at the PHELIX facility, GSI Darmstadt with respect to achievable repetition rate and at wavelengths below 20 nm was significantly improved, and also important information for the development towards multi-100 eV plasma XRLs was acquired. Due to the setup improvements achieved during the work for this thesis, the PHELIX XRL system now has reached a degree of reproducibility and versatility which is sufficient for demanding applications like the XRL spectroscopy of heavy ions. In addition, a European research campaign, aiming towards plasma XRLs approaching the water-window (wavelengths below 5 nm) was initiated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Die chronisch obstruktive Lungenerkrankung (engl. chronic obstructive pulmonary disease, COPD) ist ein Überbegriff für Erkrankungen, die zu Husten, Auswurf und Dyspnoe (Atemnot) in Ruhe oder Belastung führen - zu diesen werden die chronische Bronchitis und das Lungenemphysem gezählt. Das Fortschreiten der COPD ist eng verknüpft mit der Zunahme des Volumens der Wände kleiner Luftwege (Bronchien). Die hochauflösende Computertomographie (CT) gilt bei der Untersuchung der Morphologie der Lunge als Goldstandard (beste und zuverlässigste Methode in der Diagnostik). Möchte man Bronchien, eine in Annäherung tubuläre Struktur, in CT-Bildern vermessen, so stellt die geringe Größe der Bronchien im Vergleich zum Auflösungsvermögen eines klinischen Computertomographen ein großes Problem dar. In dieser Arbeit wird gezeigt wie aus konventionellen Röntgenaufnahmen CT-Bilder berechnet werden, wo die mathematischen und physikalischen Fehlerquellen im Bildentstehungsprozess liegen und wie man ein CT-System mittels Interpretation als lineares verschiebungsinvariantes System (engl. linear shift invariant systems, LSI System) mathematisch greifbar macht. Basierend auf der linearen Systemtheorie werden Möglichkeiten zur Beschreibung des Auflösungsvermögens bildgebender Verfahren hergeleitet. Es wird gezeigt wie man den Tracheobronchialbaum aus einem CT-Datensatz stabil segmentiert und mittels eines topologieerhaltenden 3-dimensionalen Skelettierungsalgorithmus in eine Skelettdarstellung und anschließend in einen kreisfreien Graphen überführt. Basierend auf der linearen System Theorie wird eine neue, vielversprechende, integral-basierte Methodik (IBM) zum Vermessen kleiner Strukturen in CT-Bildern vorgestellt. Zum Validieren der IBM-Resultate wurden verschiedene Messungen an einem Phantom, bestehend aus 10 unterschiedlichen Silikon Schläuchen, durchgeführt. Mit Hilfe der Skelett- und Graphendarstellung ist ein Vermessen des kompletten segmentierten Tracheobronchialbaums im 3-dimensionalen Raum möglich. Für 8 zweifach gescannte Schweine konnte eine gute Reproduzierbarkeit der IBM-Resultate nachgewiesen werden. In einer weiteren, mit IBM durchgeführten Studie konnte gezeigt werden, dass die durchschnittliche prozentuale Bronchialwandstärke in CT-Datensätzen von 16 Rauchern signifikant höher ist, als in Datensätzen von 15 Nichtrauchern. IBM läßt sich möglicherweise auch für Wanddickenbestimmungen bei Problemstellungen aus anderen Arbeitsgebieten benutzen - kann zumindest als Ideengeber dienen. Ein Artikel mit der Beschreibung der entwickelten Methodik und der damit erzielten Studienergebnisse wurde zur Publikation im Journal IEEE Transactions on Medical Imaging angenommen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this research was to develop a working physical model of the focused plenoptic camera and develop software that can process the measured image intensity, reconstruct this into a full resolution image, and to develop a depth map from its corresponding rendered image. The plenoptic camera is a specialized imaging system designed to acquire spatial, angular, and depth information in a single intensity measurement. This camera can also computationally refocus an image by adjusting the patch size used to reconstruct the image. The published methods have been vague and conflicting, so the motivation behind this research is to decipher the work that has been done in order to develop a working proof-of-concept model. This thesis outlines the theory behind the plenoptic camera operation and shows how the measured intensity from the image sensor can be turned into a full resolution rendered image with its corresponding depth map. The depth map can be created by a cross-correlation of adjacent sub-images created by the microlenslet array (MLA.) The full resolution image reconstruction can be done by taking a patch from each MLA sub-image and piecing them together like a puzzle. The patch size determines what object plane will be in-focus. This thesis also goes through a very rigorous explanation of the design constraints involved with building a plenoptic camera. Plenoptic camera data from Adobe © was used to help with the development of the algorithms written to create a rendered image and its depth map. Finally, using the algorithms developed from these tests and the knowledge for developing the plenoptic camera, a working experimental system was built, which successfully generated a rendered image and its corresponding depth map.