823 resultados para Human motion monitoring


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The stratum corneum (SC) barrier typically consists of layers of corneocytes embedded in a lipid continuum that regulates barrier function. The lipid domain containing ceramides, cholesterol, and free fatty acids provides the major pathway for most drugs permeating across SC. Penetration enhancers diminish the SC barrier function. The classic enhancer is dimethyl sulfoxide (DMSO). Its mechanisms of action remain unclear, although DMSO disrupts lipid organisation and may displace protein-bound water. Here we use confocal Raman spectroscopy to probe molecular interactions between a finite (depleting) dose of DMSO and SC, as functions of depth and time, providing novel information about residence time and location of DMSO in human SC in vivo

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Considering that counting the percentage of CD4 T lymphocytes can add prognostic information regarding patients infected with HIV, the aim of this study was to evaluate the percentage values of CD4+ T lymphocytes from 81 patients determined by flow cytometry and estimated by flow cytometry in conjunction with a hematology counter. Means were compared through the Student's t-test. Pearson's correlation was determined, and the agreement between results was tested by Bland-Altman. The level of significance was P < 0.05. It was found a significantly higher mean difference between the relative values of CD4+ T lymphocytes to the hematologic counter (P < 0.05), for all strata studied. Positive and significant correlations (P < 0.01) were found between the strata CD4 < 200 cells/mL (r = 0.93), between 200 and 500 cells/mL (r = 0.65), and >500 cells/mL (r = 0.81). The limits of agreement were 1.0 +/- 3.8% for the stratum of CD4 < 200 cells/mL, approximately 2.2 +/- 13.5% for the stratum of CD4 between 200 and 500 cells/mL, and approximately 6.2 +/- 20.4% for the stratum > 500 cells/mL. The differences in the percentages of CD4+ T lymphocytes obtained by different methodologies could lead to conflict when used in clinical decisions related to the treatment and care of people infected with HIV.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

40.00% 40.00%

Publicador:

Resumo:

L’analisi del movimento umano ha come obiettivo la descrizione del movimento assoluto e relativo dei segmenti ossei del soggetto e, ove richiesto, dei relativi tessuti molli durante l’esecuzione di esercizi fisici. La bioingegneria mette a disposizione dell’analisi del movimento gli strumenti ed i metodi necessari per una valutazione quantitativa di efficacia, funzione e/o qualità del movimento umano, consentendo al clinico l’analisi di aspetti non individuabili con gli esami tradizionali. Tali valutazioni possono essere di ausilio all’analisi clinica di pazienti e, specialmente con riferimento a problemi ortopedici, richiedono una elevata accuratezza e precisione perché il loro uso sia valido. Il miglioramento della affidabilità dell’analisi del movimento ha quindi un impatto positivo sia sulla metodologia utilizzata, sia sulle ricadute cliniche della stessa. Per perseguire gli obiettivi scientifici descritti, è necessario effettuare una stima precisa ed accurata della posizione e orientamento nello spazio dei segmenti ossei in esame durante l’esecuzione di un qualsiasi atto motorio. Tale descrizione può essere ottenuta mediante la definizione di un modello della porzione del corpo sotto analisi e la misura di due tipi di informazione: una relativa al movimento ed una alla morfologia. L’obiettivo è quindi stimare il vettore posizione e la matrice di orientamento necessari a descrivere la collocazione nello spazio virtuale 3D di un osso utilizzando le posizioni di punti, definiti sulla superficie cutanea ottenute attraverso la stereofotogrammetria. Le traiettorie dei marker, così ottenute, vengono utilizzate per la ricostruzione della posizione e dell’orientamento istantaneo di un sistema di assi solidale con il segmento sotto esame (sistema tecnico) (Cappozzo et al. 2005). Tali traiettorie e conseguentemente i sistemi tecnici, sono affetti da due tipi di errore, uno associato allo strumento di misura e l’altro associato alla presenza di tessuti molli interposti tra osso e cute. La propagazione di quest’ultimo ai risultati finali è molto più distruttiva rispetto a quella dell’errore strumentale che è facilmente minimizzabile attraverso semplici tecniche di filtraggio (Chiari et al. 2005). In letteratura è stato evidenziato che l’errore dovuto alla deformabilità dei tessuti molli durante l’analisi del movimento umano provoca inaccuratezze tali da mettere a rischio l’utilizzabilità dei risultati. A tal proposito Andriacchi scrive: “attualmente, uno dei fattori critici che rallentano il progresso negli studi del movimento umano è la misura del movimento scheletrico partendo dai marcatori posti sulla cute” (Andriacchi et al. 2000). Relativamente alla morfologia, essa può essere acquisita, ad esempio, attraverso l’utilizzazione di tecniche per bioimmagini. Queste vengono fornite con riferimento a sistemi di assi locali in generale diversi dai sistemi tecnici. Per integrare i dati relativi al movimento con i dati morfologici occorre determinare l’operatore che consente la trasformazione tra questi due sistemi di assi (matrice di registrazione) e di conseguenza è fondamentale l’individuazione di particolari terne di riferimento, dette terne anatomiche. L’identificazione di queste terne richiede la localizzazione sul segmento osseo di particolari punti notevoli, detti repere anatomici, rispetto ad un sistema di riferimento solidale con l’osso sotto esame. Tale operazione prende il nome di calibrazione anatomica. Nella maggior parte dei laboratori di analisi del movimento viene implementata una calibrazione anatomica a “bassa risoluzione” che prevede la descrizione della morfologia dell’osso a partire dall’informazione relativa alla posizione di alcuni repere corrispondenti a prominenze ossee individuabili tramite palpazione. Attraverso la stereofotogrammetria è quindi possibile registrare la posizione di questi repere rispetto ad un sistema tecnico. Un diverso approccio di calibrazione anatomica può essere realizzato avvalendosi delle tecniche ad “alta risoluzione”, ovvero attraverso l’uso di bioimmagini. In questo caso è necessario disporre di una rappresentazione digitale dell’osso in un sistema di riferimento morfologico e localizzare i repere d’interesse attraverso palpazione in ambiente virtuale (Benedetti et al. 1994 ; Van Sint Jan et al. 2002; Van Sint Jan et al. 2003). Un simile approccio è difficilmente applicabile nella maggior parte dei laboratori di analisi del movimento, in quanto normalmente non si dispone della strumentazione necessaria per ottenere le bioimmagini; inoltre è noto che tale strumentazione in alcuni casi può essere invasiva. Per entrambe le calibrazioni anatomiche rimane da tenere in considerazione che, generalmente, i repere anatomici sono dei punti definiti arbitrariamente all’interno di un’area più vasta e irregolare che i manuali di anatomia definiscono essere il repere anatomico. L’identificazione dei repere attraverso una loro descrizione verbale è quindi povera in precisione e la difficoltà nella loro identificazione tramite palpazione manuale, a causa della presenza dei tessuti molli interposti, genera errori sia in precisione che in accuratezza. Tali errori si propagano alla stima della cinematica e della dinamica articolare (Ramakrishnan et al. 1991; Della Croce et al. 1999). Della Croce (Della Croce et al. 1999) ha inoltre evidenziato che gli errori che influenzano la collocazione nello spazio delle terne anatomiche non dipendono soltanto dalla precisione con cui vengono identificati i repere anatomici, ma anche dalle regole che si utilizzano per definire le terne. E’ infine necessario evidenziare che la palpazione manuale richiede tempo e può essere effettuata esclusivamente da personale altamente specializzato, risultando quindi molto onerosa (Simon 2004). La presente tesi prende lo spunto dai problemi sopra elencati e ha come obiettivo quello di migliorare la qualità delle informazioni necessarie alla ricostruzione della cinematica 3D dei segmenti ossei in esame affrontando i problemi posti dall’artefatto di tessuto molle e le limitazioni intrinseche nelle attuali procedure di calibrazione anatomica. I problemi sono stati affrontati sia mediante procedure di elaborazione dei dati, sia apportando modifiche ai protocolli sperimentali che consentano di conseguire tale obiettivo. Per quanto riguarda l’artefatto da tessuto molle, si è affrontato l’obiettivo di sviluppare un metodo di stima che fosse specifico per il soggetto e per l’atto motorio in esame e, conseguentemente, di elaborare un metodo che ne consentisse la minimizzazione. Il metodo di stima è non invasivo, non impone restrizione al movimento dei tessuti molli, utilizza la sola misura stereofotogrammetrica ed è basato sul principio della media correlata. Le prestazioni del metodo sono state valutate su dati ottenuti mediante una misura 3D stereofotogrammetrica e fluoroscopica sincrona (Stagni et al. 2005), (Stagni et al. 2005). La coerenza dei risultati raggiunti attraverso i due differenti metodi permette di considerare ragionevoli le stime dell’artefatto ottenute con il nuovo metodo. Tale metodo fornisce informazioni sull’artefatto di pelle in differenti porzioni della coscia del soggetto e durante diversi compiti motori, può quindi essere utilizzato come base per un piazzamento ottimo dei marcatori. Lo si è quindi utilizzato come punto di partenza per elaborare un metodo di compensazione dell’errore dovuto all’artefatto di pelle che lo modella come combinazione lineare degli angoli articolari di anca e ginocchio. Il metodo di compensazione è stato validato attraverso una procedura di simulazione sviluppata ad-hoc. Relativamente alla calibrazione anatomica si è ritenuto prioritario affrontare il problema associato all’identificazione dei repere anatomici perseguendo i seguenti obiettivi: 1. migliorare la precisione nell’identificazione dei repere e, di conseguenza, la ripetibilità dell’identificazione delle terne anatomiche e della cinematica articolare, 2. diminuire il tempo richiesto, 3. permettere che la procedura di identificazione possa essere eseguita anche da personale non specializzato. Il perseguimento di tali obiettivi ha portato alla implementazione dei seguenti metodi: • Inizialmente è stata sviluppata una procedura di palpazione virtuale automatica. Dato un osso digitale, la procedura identifica automaticamente i punti di repere più significativi, nella maniera più precisa possibile e senza l'ausilio di un operatore esperto, sulla base delle informazioni ricavabili da un osso digitale di riferimento (template), preliminarmente palpato manualmente. • E’ stato poi condotto uno studio volto ad indagare i fattori metodologici che influenzano le prestazioni del metodo funzionale nell’individuazione del centro articolare d’anca, come prerequisito fondamentale per migliorare la procedura di calibrazione anatomica. A tale scopo sono stati confrontati diversi algoritmi, diversi cluster di marcatori ed è stata valutata la prestazione del metodo in presenza di compensazione dell’artefatto di pelle. • E’stato infine proposto un metodo alternativo di calibrazione anatomica basato sull’individuazione di un insieme di punti non etichettati, giacenti sulla superficie dell’osso e ricostruiti rispetto ad un TF (UP-CAST). A partire dalla posizione di questi punti, misurati su pelvi coscia e gamba, la morfologia del relativo segmento osseo è stata stimata senza identificare i repere, bensì effettuando un’operazione di matching dei punti misurati con un modello digitale dell’osso in esame. La procedura di individuazione dei punti è stata eseguita da personale non specializzato nell’individuazione dei repere anatomici. Ai soggetti in esame è stato richiesto di effettuare dei cicli di cammino in modo tale da poter indagare gli effetti della nuova procedura di calibrazione anatomica sulla determinazione della cinematica articolare. I risultati ottenuti hanno mostrato, per quel che riguarda la identificazione dei repere, che il metodo proposto migliora sia la precisione inter- che intraoperatore, rispetto alla palpazione convenzionale (Della Croce et al. 1999). E’ stato inoltre riscontrato un notevole miglioramento, rispetto ad altri protocolli (Charlton et al. 2004; Schwartz et al. 2004), nella ripetibilità della cinematica 3D di anca e ginocchio. Bisogna inoltre evidenziare che il protocollo è stato applicato da operatori non specializzati nell’identificazione dei repere anatomici. Grazie a questo miglioramento, la presenza di diversi operatori nel laboratorio non genera una riduzione di ripetibilità. Infine, il tempo richiesto per la procedura è drasticamente diminuito. Per una analisi che include la pelvi e i due arti inferiori, ad esempio, l’identificazione dei 16 repere caratteristici usando la calibrazione convenzionale richiede circa 15 minuti, mentre col nuovo metodo tra i 5 e i 10 minuti.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In case of severe osteoarthritis at the knee causing pain, deformity, and loss of stability and mobility, the clinicians consider that the substitution of these surfaces by means of joint prostheses. The objectives to be pursued by this surgery are: complete pain elimination, restoration of the normal physiological mobility and joint stability, correction of all deformities and, thus, of limping. The knee surgical navigation systems have bee developed in computer-aided surgery in order to improve the surgical final outcome in total knee arthroplasty. These systems provide the surgeon with quantitative and real-time information about each surgical action, like bone cut executions and prosthesis component alignment, by mean of tracking tools rigidly fixed onto the femur and the tibia. Nevertheless, there is still a margin of error due to the incorrect surgical procedures and to the still limited number of kinematic information provided by the current systems. Particularly, patello-femoral joint kinematics is not considered in knee surgical navigation. It is also unclear and, thus, a source of misunderstanding, what the most appropriate methodology is to study the patellar motion. In addition, also the knee ligamentous apparatus is superficially considered in navigated total knee arthroplasty, without taking into account how their physiological behavior is altered by this surgery. The aim of the present research work was to provide new functional and biomechanical assessments for the improvement of the surgical navigation systems for joint replacement in the human lower limb. This was mainly realized by means of the identification and development of new techniques that allow a thorough comprehension of the functioning of the knee joint, with particular attention to the patello-femoral joint and to the main knee soft tissues. A knee surgical navigation system with active markers was used in all research activities presented in this research work. Particularly, preliminary test were performed in order to assess the system accuracy and the robustness of a number of navigation procedures. Four studies were performed in-vivo on patients requiring total knee arthroplasty and randomly implanted by means of traditional and navigated procedures in order to check for the real efficacy of the latter with respect to the former. In order to cope with assessment of patello-femoral joint kinematics in the intact and replaced knees, twenty in-vitro tests were performed by using a prototypal tracking tool also for the patella. In addition to standard anatomical and articular recommendations, original proposals for defining the patellar anatomical-based reference frame and for studying the patello-femoral joint kinematics were reported and used in these tests. These definitions were applied to two further in-vitro tests in which, for the first time, also the implant of patellar component insert was fully navigated. In addition, an original technique to analyze the main knee soft tissues by means of anatomical-based fiber mappings was also reported and used in the same tests. The preliminary instrumental tests revealed a system accuracy within the millimeter and a good inter- and intra-observer repeatability in defining all anatomical reference frames. In in-vivo studies, the general alignments of femoral and tibial prosthesis components and of the lower limb mechanical axis, as measured on radiographs, was more satisfactory, i.e. within ±3°, in those patient in which total knee arthroplasty was performed by navigated procedures. As for in-vitro tests, consistent patello-femoral joint kinematic patterns were observed over specimens throughout the knee flexion arc. Generally, the physiological intact knee patellar motion was not restored after the implant. This restoration was successfully achieved in the two further tests where all component implants, included the patellar insert, were fully navigated, i.e. by means of intra-operative assessment of also patellar component positioning and general tibio-femoral and patello-femoral joint assessment. The tests for assessing the behavior of the main knee ligaments revealed the complexity of the latter and the different functional roles played by the several sub-bundles compounding each ligament. Also in this case, total knee arthroplasty altered the physiological behavior of these knee soft tissues. These results reveal in-vitro the relevance and the feasibility of the applications of new techniques for accurate knee soft tissues monitoring, patellar tracking assessment and navigated patellar resurfacing intra-operatively in the contest of the most modern operative techniques. This present research work gives a contribution to the much controversial knowledge on the normal and replaced of knee kinematics by testing the reported new methodologies. The consistence of these results provides fundamental information for the comprehension and improvements of knee orthopedic treatments. In the future, the reported new techniques can be safely applied in-vivo and also adopted in other joint replacements.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Knowledge on how ligaments and articular surfaces guide passive motion at the human ankle joint complex is fundamental for the design of relevant surgical treatments. The dissertation presents a possible improvement of this knowledge by a new kinematic model of the tibiotalar articulation. In this dissertation two one-DOF spatial equivalent mechanisms are presented for the simulation of the passive motion of the human ankle joint: the 5-5 fully parallel mechanism and the fully parallel spherical wrist mechanism. These mechanisms are based on the main anatomical structures of the ankle joint, namely the talus/calcaneus and the tibio/fibula bones at their interface, and the TiCaL and CaFiL ligaments. In order to show the accuracy of the models and the efficiency of the proposed procedure, these mechanisms are synthesized from experimental data and the results are compared with those obtained both during experimental sessions and with data published in the literature. Experimental results proved the efficiency of the proposed new mechanisms to simulate the ankle passive motion and, at the same time, the potentiality of the mechanism to replicate the ankle’s main anatomical structures quite well. The new mechanisms represent a powerful tool for both pre-operation planning and new prosthesis design.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The relevance of human joint models was shown in the literature. In particular, the great importance of models for the joint passive motion simulation (i.e. motion under virtually unloaded conditions) was outlined. They clarify the role played by the principal anatomical structures of the articulation, enhancing the comprehension of surgical treatments, and in particular the design of total ankle replacement and ligament reconstruction. Equivalent rigid link mechanisms proved to be an efficient tool for an accurate simulation of the joint passive motion. This thesis focuses on the ankle complex (i.e. the anatomical structure composed of the tibiotalar and the subtalar joints), which has a considerable role in human locomotion. The lack of interpreting models of this articulation and the poor results of total ankle replacement arthroplasty have strongly suggested devising new mathematical models capable of reproducing the restraining function of each structure of the joint and of replicating the relative motion of the bones which constitute the joint itself. In this contest, novel equivalent mechanisms are proposed for modelling the ankle passive motion. Their geometry is based on the joint’s anatomical structures. In particular, the role of the main ligaments of the articulation is investigated under passive conditions by means of nine 5-5 fully parallel mechanisms. Based on this investigation, a one-DOF spatial mechanism is developed for modelling the passive motion of the lower leg. The model considers many passive structures constituting the articulation, overcoming the limitations of previous models which took into account few anatomical elements of the ankle complex. All the models have been identified from experimental data by means of optimization procedure. Then, the simulated motions have been compared to the experimental one, in order to show the efficiency of the approach and thus to deduce the role of each anatomical structure in the ankle kinematic behavior.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The chemotherapeutic drug 5-fluorouracil (5-FU) is widely used for treating solid tumors. Response to 5-FU treatment is variable with 10-30% of patients experiencing serious toxicity partly explained by reduced activity of dihydropyrimidine dehydrogenase (DPD). DPD converts endogenous uracil (U) into 5,6-dihydrouracil (UH(2) ), and analogously, 5-FU into 5-fluoro-5,6-dihydrouracil (5-FUH(2) ). Combined quantification of U and UH(2) with 5-FU and 5-FUH(2) may provide a pre-therapeutic assessment of DPD activity and further guide drug dosing during therapy. Here, we report the development of a liquid chromatography-tandem mass spectrometry assay for simultaneous quantification of U, UH(2) , 5-FU and 5-FUH(2) in human plasma. Samples were prepared by liquid-liquid extraction with 10:1 ethyl acetate-2-propanol (v/v). The evaporated samples were reconstituted in 0.1% formic acid and 10 μL aliquots were injected into the HPLC system. Analyte separation was achieved on an Atlantis dC(18) column with a mobile phase consisting of 1.0 mm ammonium acetate, 0.5 mm formic acid and 3.3% methanol. Positively ionized analytes were detected by multiple reaction monitoring. The analytical response was linear in the range 0.01-10 μm for U, 0.1-10 μm for UH(2) , 0.1-75 μm for 5-FU and 0.75-75 μm for 5-FUH(2) , covering the expected concentration ranges in plasma. The method was validated following the FDA guidelines and applied to clinical samples obtained from ten 5-FU-treated colorectal cancer patients. The present method merges the analysis of 5-FU pharmacokinetics and DPD activity into a single assay representing a valuable tool to improve the efficacy and safety of 5-FU-based chemotherapy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Utilizing advanced information technology, Intensive Care Unit (ICU) remote monitoring allows highly trained specialists to oversee a large number of patients at multiple sites on a continuous basis. In the current research, we conducted a time-motion study of registered nurses’ work in an ICU remote monitoring facility. Data were collected on seven nurses through 40 hours of observation. The results showed that nurses’ essential tasks were centered on three themes: monitoring patients, maintaining patients’ health records, and managing technology use. In monitoring patients, nurses spent 52% of the time assimilating information embedded in a clinical information system and 15% on monitoring live vitals. System-generated alerts frequently interrupted nurses in their task performance and redirected them to manage suddenly appearing events. These findings provide insight into nurses’ workflow in a new, technology-driven critical care setting and have important implications for system design, work engineering, and personnel selection and training.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE To reliably determine the amplitude of the transmit radiofrequency ( B1+) field in moving organs like the liver and heart, where most current techniques are usually not feasible. METHODS B1+ field measurement based on the Bloch-Siegert shift induced by a pair of Fermi pulses in a double-triggered modified Point RESolved Spectroscopy (PRESS) sequence with motion-compensated crusher gradients has been developed. Performance of the sequence was tested in moving phantoms and in muscle, liver, and heart of six healthy volunteers each, using different arrangements of transmit/receive coils. RESULTS B1+ determination in a moving phantom was almost independent of type and amplitude of the motion and agreed well with theory. In vivo, repeated measurements led to very small coefficients of variance (CV) if the amplitude of the Fermi pulse was chosen above an appropriate level (CV in muscle 0.6%, liver 1.6%, heart 2.3% with moderate amplitude of the Fermi pulses and 1.2% with stronger Fermi pulses). CONCLUSION The proposed sequence shows a very robust determination of B1+ in a single voxel even under challenging conditions (transmission with a surface coil or measurements in the heart without breath-hold). Magn Reson Med, 2015. © 2015 Wiley Periodicals, Inc.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Here an inertial sensor-based monitoring system for measuring and analyzing upper limb movements is presented. The final goal is the integration of this motion-tracking device within a portable rehabilitation system for brain injury patients. A set of four inertial sensors mounted on a special garment worn by the patient provides the quaternions representing the patient upper limb’s orientation in space. A kinematic model is built to estimate 3D upper limb motion for accurate therapeutic evaluation. The human upper limb is represented as a kinematic chain of rigid bodies with three joints and six degrees of freedom. Validation of the system has been performed by co-registration of movements with a commercial optoelectronic tracking system. Successful results are shown that exhibit a high correlation among signals provided by both devices and obtained at the Institut Guttmann Neurorehabilitation Hospital.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

En este proyecto, se presenta un informe técnico sobre la cámara Leap Motion y el Software Development Kit correspondiente, el cual es un dispositivo con una cámara de profundidad orientada a interfaces hombre-máquina. Esto es realizado con el propósito de desarrollar una interfaz hombre-máquina basada en un sistema de reconocimiento de gestos de manos. Después de un exhaustivo estudio de la cámara Leap Motion, se han realizado diversos programas de ejemplo con la intención de verificar las capacidades descritas en el informe técnico, poniendo a prueba la Application Programming Interface y evaluando la precisión de las diferentes medidas obtenidas sobre los datos de la cámara. Finalmente, se desarrolla un prototipo de un sistema de reconocimiento de gestos. Los datos sobre la posición y orientación de la punta de los dedos obtenidos de la Leap Motion son usados para describir un gesto mediante un vector descriptor, el cual es enviado a una Máquina Vectores Soporte, utilizada como clasificador multi-clase.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mechanistic insights to viral replication and pathogenesis generally have come from the analysis of viral gene products, either by studying their biochemical activities and interactions individually or by creating mutant viruses and analyzing their phenotype. Now it is possible to identify and catalog the host cell genes whose mRNA levels change in response to a pathogen. We have used DNA array technology to monitor the level of ≈6,600 human mRNAs in uninfected as compared with human cytomegalovirus-infected cells. The level of 258 mRNAs changed by a factor of 4 or more before the onset of viral DNA replication. Several of these mRNAs encode gene products that might play key roles in virus-induced pathogenesis, identifying them as intriguing targets for further study.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Microarrays containing 1046 human cDNAs of unknown sequence were printed on glass with high-speed robotics. These 1.0-cm2 DNA "chips" were used to quantitatively monitor differential expression of the cognate human genes using a highly sensitive two-color hybridization assay. Array elements that displayed differential expression patterns under given experimental conditions were characterized by sequencing. The identification of known and novel heat shock and phorbol ester-regulated genes in human T cells demonstrates the sensitivity of the assay. Parallel gene analysis with microarrays provides a rapid and efficient method for large-scale human gene discovery.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Women’s handball is a sport, which has seen an accelerated development over the last decade. Data on movement patterns in combination with physiological demands are nearly nonexistent in the literature. The aim of this study was twofold: first, to analyze the horizontal movement pattern, including the sprint acceleration profiles, of individual female elite handball players and the corresponding heart rates (HRs) during a match and secondly to determine underlying correlations with individual aerobic performance. Players from one German First League team (n = 11) and the Norwegian National Team (n = 14) were studied during one match using the Sagit system for movement analysis and Polar HR monitoring for analysis of physiological demands. Mean HR during the match was 86 % of maximum HR (HRmax). With the exception of the goalkeepers (GKs, 78 % of HRmax), no position-specific differences could be detected. Total distance covered during the match was 4614 m (2066 m in GKs and 5251 m in field players (FPs)). Total distance consisted of 9.2 % sprinting, 26.7 % fast running, 28.8 % slow running, and 35.5 % walking. Mean velocity varied between 1.9 km/h (0.52 m/s) (GKs) and 4.2 km/h (1.17 m/s) (FPs, no position effect). Field players with a higher level of maximum oxygen uptake (V̇O2max) executed run activities with a higher velocity but comparable percentage of HRmax as compared to players with lower aerobic performance, independent of FP position. Acceleration profile depended on aerobic performance and the field player’s position. In conclusion, a high V̇O2max appears to be important in top-level international women’s handball. Sprint and endurance training should be conducted according to the specific demands of the player’s position.