992 resultados para Hemoglobin oxygen saturation
Resumo:
BACKGROUND: Previous studies have shown positive effects from noninvasive ventilation (NIV) or supplemental oxygen on exercise capacity in patients with COPD. However, the best adjunct for promoting physiologic adaptations to physical training in patients with severe COPD remains to be investigated. METHODS: Twenty-eight patients (mean +/- SD age 68 +/- 7 y) with stable COPD (FEV(1) 34 +/- 9% of predicted) undergoing an exercise training program were randomized to either NIV (n = 14) or supplemental oxygen (n = 14) during group training to maintain peripheral oxygen saturation (S(pO2)) >= 90%. Physical training consisted of treadmill walking (at 70% of maximal speed) 3 times a week, for 6 weeks. Patients were assessed at baseline and after 6 weeks. Assessments included physiological adaptations during incremental exercise testing (ratio of lactate concentration to walk speed, oxygen uptake [(V) over dot(O2)], and dyspnea), exercise tolerance during 6-min walk test, leg fatigue, maximum inspiratory pressure, and health-related quality of life. RESULTS: Two patients in each group dropped out due to COPD exacerbations and lack of exercise program adherence, and 24 completed the training program. Both groups improved 6-min walk distance, symptoms, and health-related quality of life. However, there were significant differences between the NIV and supplemental-oxygen groups in lactate/speed ratio (33% vs -4%), maximum inspiratory pressure (80% vs 23%), 6-min walk distance (122 m vs 47 m), and leg fatigue (25% vs 11%). In addition, changes in S(pO2)/speed, (V) over dot(O2), and dyspnea were greater with NIV than with supplemental-oxygen. CONCLUSIONS: NIV alone is better than supplemental oxygen alone in promoting beneficial physiologic adaptations to physical exercise in patients with severe COPD.
Resumo:
The medical records of 27 patients with hantavirus pulmonary syndrome were analyzed according to the need for invasive mechanical ventilation in relation to the following data up on hospital admission: age, gender, fever, cough, dyspnea, systolic arterial blood pressure, heart rate, levels of hemoglobin, hematocrit, leukocytes, lymphocytes, platelets, creatinine and arterial blood gases. The volume infused during the first 24 hours after admission, the use of inotropic agents, the use of corticosteroids and the patient outcomes were also evaluated. A favorable outcome was related to systolic blood pressure³ 100mmHg, heart rate lower than 100 beats per minute, creatinine below 1.6mg/dl, arterial blood pH³ 7.35, bicarbonate higher than 15mEq/dl, oxygen saturation higher than 84.1%, lower rehydration volume in the first 24 hours of hospitalization and no use of inotropic agents. Absence of clinical and laboratory signs of circulatory shock up on admission was associated with a favorable outcome of the patients.
Resumo:
Pulse oximetry has been proposed as a noninvasive continuous method for transcutaneous monitoring of arterial oxygen saturation of hemoglobin (tcSO2) in the newborn infant. The reliability of this technique in detecting hyperoxemia is controversial, because small changes in saturation greater than 90% are associated with relatively large changes in arterial oxygen tension (PaO2). The purpose of this study was to assess the reliability of pulse oximetry using an alarm limit of 95% tcSO2 in detecting hyperoxemia (defined as PaO2 greater than 90 mm Hg) and to examine the effect of varying the alarm limit on reliability. Two types of pulse oximeter were studied alternately in 50 newborn infants who were mechanically ventilated with indwelling arterial lines. Three arterial blood samples were drawn from every infant during routine increase of inspired oxygen before intratracheal suction, and PaO2 was compared with tcSO2. The Nellcor N-100 pulse oximeter identified all 26 hyperoxemic instances correctly (sensitivity 100%) and alarmed falsely in 25 of 49 nonhyperoxemic instances (specificity 49%). The Ohmeda Biox 3700 pulse oximeter detected 13 of 35 hyperoxemic instances (sensitivity 37%) and alarmed falsely in 7 of 40 nonhyperoxemic instances (specificity 83%). The optimal alarm limit, defined as a sensitivity of 95% or more associated with maximal specificity, was determined for Nellcor N-100 at 96% tcSO2 (specificity 38%) and for Ohmeda Biox 3700 at 89% tcSO2 (specificity 52%). It was concluded that pulse oximeters can be highly sensitive in detecting hyperoxemia provided that type-specific alarm limits are set and a low specificity is accepted.
Resumo:
INTRODUCTION Higher and lower cerebral perfusion pressure (CPP) thresholds have been proposed to improve brain tissue oxygen pressure (PtiO2) and outcome. We study the distribution of hypoxic PtiO2 samples at different CPP thresholds, using prospective multimodality monitoring in patients with severe traumatic brain injury. METHODS This is a prospective observational study of 22 severely head injured patients admitted to a neurosurgical critical care unit from whom multimodality data was collected during standard management directed at improving intracranial pressure, CPP and PtiO2. Local PtiO2 was continuously measured in uninjured areas and snapshot samples were collected hourly and analyzed in relation to simultaneous CPP. Other variables that influence tissue oxygen availability, mainly arterial oxygen saturation, end tidal carbon dioxide, body temperature and effective hemoglobin, were also monitored to keep them stable in order to avoid non-ischemic hypoxia. RESULTS Our main results indicate that half of PtiO2 samples were at risk of hypoxia (defined by a PtiO2 equal to or less than 15 mmHg) when CPP was below 60 mmHg, and that this percentage decreased to 25% and 10% when CPP was between 60 and 70 mmHg and above 70 mmHg, respectively (p < 0.01). CONCLUSION Our study indicates that the risk of brain tissue hypoxia in severely head injured patients could be really high when CPP is below the normally recommended threshold of 60 mmHg, is still elevated when CPP is slightly over it, but decreases at CPP values above it.
Resumo:
BACKGROUND AND OBJECTIVE: Off-pump coronary artery bypass grafting has stimulated the development of micro-pumps designed to prevent the hemodynamic instability induced by heart luxation for the exposure of target vessels of the posterior wall. Impella (Aachen, Germany) developed micro-pumps with a miniaturized propeller system for both sides of the heart. The aim of this study was to analyze the impact of both pumps working together on blood cell integrity. MATERIALS AND METHODS: Both right and left-sided micro-pumps were implanted in 5 calves (body weight, 72_4 Kg) during 3 h. Blood samples for hematology and hemolysis parameters were drawn hourly. RESULTS: Both pumps performed well with a flow of 3.6 L +/- 0.3 L during the 3 h of the experiment with stable hemodynamic conditions. Mixed venous oxygen saturation was 63.4 +/- 15.2% at baseline and 63.8 +/- 16.3% at the end of the experiment (P = ns). Red cell count, LDH and free plasma hemoglobin were 6.7 +/- 2.1 x 10(12)/L, 1807 +/- 437 IU/L, and 32 +/- 9 mg/L at baseline vs. 6.1 +/- 2.1 x 10(12)/L, 1871 +/- 410 IU/L, and 52 +/- 9 mg/L at the end of the experiment (P = ns for all comparisons). Platelet count exhibited a non-significant drop (872 +/- 126 vs. 715 +/- 22 x 10(9)/L). CONCLUSIONS: This double pump system based on the Archimed screw principle is hematologically well tolerated under conditions of prolonged cardiac assist.
Resumo:
Sleep apnea syndrome (SAS) consists of nocturnal snoring interrupted by obstructive apnea and of diurnal symptoms like hypersomnolence as a consequence of sleep fragmentation. Cardiovascular morbidity and mortality associated with this syndrome justify early detection and appropriate treatment. Polysomnography is still a frequently used method for early detection; however, several disadvantages like duration, discomfort and expense led to a search for alternatives. Since the beginning of the eighties, oximetry allows recording of nocturnal oxygen saturation of hemoglobin even at home. Nocturnal oximetry reveals O2-desaturation associated with apnea and thus permits often to diagnose or exclude SAS. Diagnosis of SAS is made when at least 20 desaturations per hour with an amplitude of at least 4% are recorded. On the other hand, normal nocturnal oximetry nearly excludes SAS. In those cases where nocturnal oximetry is not diagnostic, polysomnography remains the method of choice. Departing from published work, a model for SAS detection, based mainly on nocturnal oximetry, is proposed.
Resumo:
The aim was to provide reference data for blood gas/acid-base status and electrolytes for non-anesthetized Amazon parrots (Amazona aestiva). Thirty-five adult parrots from Tietê ecologic park were utilized. Arterial blood (0.3ml) samples were anaerobically collected from the superficial ulnar artery in heparinized (sodium heparin) 1-ml plastic syringes. The samples were immediately analyzed through a portable analyzer (i-STAT*, Abbot, Illinois, USA) with cartridges (EG7+). These data were grouped in such a way as to present both mean and standard deviation: body weight (360±37g), respiratory rate (82±33 b/m), temperature (41.8±0.6°C), hydrogen potential (7.452±0.048), carbon dioxide partial pressure (22.1±4.0mmHg), oxygen partial pressure (98.1±7.6mmHg), base excess (-7.9±3.1), plasma concentration of bicarbonate ions (14.8±2.8mmol/L), oxygen saturation (96.2±1.1%), plasma concentration of sodium (147.4±2.2mmol/L), plasma concentration of potassium (3.5±0.53mmol/L), plasma concentration of calcium (0.8±0.28mmol/L), hematocrit (38.7±6.2%) and concentration of hemoglobin (13.2±2.1g/dl). This study led us to conclude that, although the results obtained showed hypocapnia and low values of bicarbonate and base excess, when compared to other avian species, these data are very similar. Besides, in spite of the equipment being approved only for human beings, it was considered simple and very useful in the analysis of avian blood samples. By using this equipment we were able to provide references data for non-anaesthetized Amazon parrots.
Resumo:
Several inorganic substances (e.g., C£ , Mg , Ca , H ) are potent negative modulators of hemoglobin-oxygen affinity. To evaluate the possibility that potentially adaptive changes in the red cell ionic environment of hemoglobin may take place during acclimation of fishes to increased environmental temperature, hematological status (hemoglobin, hematocrit, red cell numbers, mean erythrocytic volume and hemoglobin content), plasma + + 2+ 2+ and packed red cell electrolyte levels (Na , K , Ca , Mg , C£ ) were evaluated in summer and winter populations of the stenothermal rainbow trout, Salmo gairdneri, following acclimation to 2°, 10°, 18°C, and in a spring population of eurythermal carp, Cyprinus carpio, held at 2°, 16° and 30°C. From these data cell ion concentrations and ion:hemoglobin ratios were estimated. In view of the role of red cell carbonic anhydrase in the reductions of blood C02 tensions and the recruitment of Na and C£~ lost by fishes, a preliminary investigation of thermoacclimatory changes in the activity of this system in rainbow trout erythrocytes was conducted. Few changes in hematological status were encountered following acclimation. There was, however, some evidence of weight-specific differential hematological response in carp. This lead to markedly greater increases in hemoglobin, hematocrit and red cell numbers in smaller rather than in larger specimens at higher temperatures; variations which were 2+ well correlated with changes in plasma Ca . Plasma composition in summer trout was not altered by acclimation. In winter trout plasma Na and K increased at higher temperatures. Carp were characterized by increases in plasma calcium, and reductions in sodium and magnesium under these conditions. Several significant seasonal differences in plasma ion levels were observed in the trout. (n) In trout, only erythrocytic K and K :Hb were altered by acclimation, rising at higher temperatures. In carp Na , Na :Hb, C£~ and C£~:Hb in- 2+ 2+ creased with temperature, while Mg and Mg :Hb declined. Changes in overall ionic composition in carp red cells were consistent with increases in H content. In both species significant reciprocal variations in C£~ 2+ - + and Mg were found. In mammalian systems increases in C£ and H reduce hemoglobin-oxygen affinity by interaction with hemoglobin. Reduction in 2+ 2+ Mg maximizes organophosphate modulator availability by decreasing ATP»Mg complex formation. Thus, the changes observed may be of adaptive value in reducing hemoglobin-oxygen affinity, and facilitating oxygen release to cells at higher temperatures. Trout appear to maintain a high chloridelow magnesium state over the entire thermal tolerance zone. Carp, however, achieved this state only at higher temperatures. In both species mean erythrocytic volume was decreased at higher temperatures and this may facilitate branchial oxygen loading. Since mean erythrocytic volume was inversely related to red cell ion content, it is hypothesized that reductions in cell volume are achieved by export of some unidentified solute or solutes. Variations in the carbonic anhydrase activity that could be attributed to the thermoacclimatory process were quite modest. On the other hand, assays performed at the temperature of acclimation showed a large temperature effect where under in vivo conditions of temperature fish acclimated to higher temperatures might be expected to have higher activities. Furthermore, since hematocrit increased with temperature in these fish, while carbonic anhydrase is present only in the erythrocyte, the whole blood levels of this enzyme are expected to increase and further augment the temperature effect. This, in turn, could aid in the reduction of C02 (111) tension and increase the production of H and HC0~~ used in the active uptake of Na and C£ at higher temperatures.
Resumo:
El manejo del trauma abdominal supone el reto de realizar una anastomosis o sutura intestinal en pacientes comprometidos hemodinámicamente. La decisión de cirugía de control de daños ante la presencia de acidosis, hipotermia y coagulopatía es evidente, sin embargo la situación no siempre es tan clara. En individuos con trauma se desarrollan cambios moleculares e inflamatorios por inadecuado balance entre aporte y demanda de oxígeno, que afectan el proceso de reparación de los tejidos con el riesgo de aparición de fístulas. Una forma rápida y práctica de detectar esta hipoperfusión es midiendo la saturación venosa de oxígeno (SVO2) y el Lactato Sérico. OBJETIVOS: Establecer correlación entre los valores de SVO2 transoperatorio y la aparición de fístulas intestinales en pacientes intervenidos por trauma abdominal. MATERIALES Y METODOS: Estudio de cohorte prospectivo que analiza diferentes variables en relación con la aparición de fistulas en pacientes con trauma abdominal que requieren suturas en el tracto gastrointestinal, haciendo énfasis en los niveles de SVO2. RESULTADOS: Los pacientes con falla anastomótica, presentaron un promedio de SVO2 más baja (60.0% ± 2.94%), versus los no fistulizados (69.89% ± 7.21%) (p =0.010). Todos los pacientes de la cohorte expuesta (SVO2<65%), presentaron dehiscencia de la anastomosis (RR =39.8, IC95%: 2.35,659.91, p<0.001, Test exacto de Fisher). El valor predictivo positivo de la saturación (<65%) fue de 57.14% (IC 95%: 13.34%, 100%) y el valor predictivo negativo fue de 100% (IC 95%:81.75%, 100%). La sensibilidad fue de 100% (IC 95%:87.50%, 100%) y especificidad de 91.89% (IC 95%: 81.75%, 100%). En el análisis bivariante determinó que el índice de trauma abdominal, el nivel de hemoglobina y el requerimiento de transfusión de glóbulos rojos, son factores de riesgo directamente relacionados con la falla de la anastomosis en pacientes con trauma abdominal CONCLUSIONES: - Hay una fuerte relación entre la falla en la reparación intestinal y SVO2 < 65%. - El pronóstico de una anastomosis intestinal está directamente relacionada con el estado hemodinámico y la perfusión tisular al momento de la intervención quirúrgica. - El nivel de SVO2 puede apoyar al cirujano en la decisión de realizar o no una reparación en víscera hueca al momento de intervención quirúrgica en un paciente con trauma abdominal.
Resumo:
Introducción. En Colombia, el 80% de los pacientes con enfermedad renal crónica en hemodiálisis tienen fístula arteriovenosa periférica (FAV) que asegura el flujo de sangre durante la hemodiálisis (1), la variabilidad en el flujo de sangre en el brazo de la FAV hacia la parte distal, puede afectar la lectura de la oximetría de pulso (SpO2) (2), llevando a la toma de decisiones equivocadas por el personal de salud. El objetivo de este estudio es aclarar si existe diferencia entre la SpO2 del brazo de la FAV y el brazo contralateral. Materiales y métodos. Se realizó un estudio de correlación entre los valores de SpO2 del brazo con FAV contra el brazo sin FAV, de 40 pacientes que asistieron a hemodiálisis. La recolección de los datos se llevó a cabo, con un formato que incluyó el resultado de la pulsioximetria y variables asociadas, antes, durante y después de la hemodiálisis. Se comparó la mediana de los deltas de las diferencias con pruebas estadísticas T Student – Mann Whitney, aceptando un valor significativo de p < 0,05. Resultados. No se encontraron diferencias estadísticamente significativas de la SpO2 entre el brazo con FAV y el brazo sin FAV, antes, durante y después de la diálisis, sin embargo si se apreció una correlación positiva estadísticamente significativa. Conclusiones. Se encontró correlación positiva estadísticamente significativa, donde no hubo diferencias en el resultado la pulsioximetría entre el brazo con FAV y brazo sin FAV, por lo tanto es válido tomar la pulsioximetría en cualquiera de los brazos.
Resumo:
Objetivos – Descrever as características clínicas de crianças entre 1 e 12 meses hospitalizadas com diagnóstico de bronquiolite viral aguda (BVA), nos primeiros dias de internação, e verificar se o tempo de dessaturação de oxigênio (TD) tem valor prognóstico nesses pacientes. Metodologia – Estudo de coorte realizado de maio a outubro de 2001 com 111 pacientes entre 1 e 12 meses de idade internados no Hospital da Criança Santo Antônio, de Porto Alegre (RS), com diagnóstico de BVA na admissão, com saturação transcutânea de oxigênio da hemoglobina (SatHb) menor que 95% e em oxigenoterapia por cateter extranasal há menos de 24 horas. A gravidade foi verificada através do tempo de internação, tempo de oxigenoterapia e tempo para saturar 95% em ar ambiente (desfechos). Foram realizadas avaliações clínicas duas vezes ao dia (manhã e tarde), durante o período em que o paciente necessitou de oxigênio suplementar (até atingir saturação transcutânea de oxigênio de 95% em ar ambiente), com limite de dez avaliações. Os pacientes tiveram o oxigênio adicional retirado. Foi verificado, então, o tempo necessário para a saturação decrescer até 90% (TD90) e 85% (TD85), limitando-se a medida em no máximo cinco minutos. Foi constituído um escore de gravidade com os sinais clínicos anotados. Utilizou-se o teste do qui-quadrado ou teste exato de Fischer para comparar entre si os grupos de variáveis categóricas e o teste t ou MannWhitney para variáveis numéricas. Foi utilizada a correlação de Spearman para avaliar associações entre variáveis contínuas de distribuição assimétrica (escore de gravidade, tempo de internação, tempo de oxigenoterapia total e tempo para saturar acima ou igual a 95% em ar ambiente). Considerou-se alfa crítico de 5% em todas as comparações, exceto nas correlações em que foi utilizada a correção de Bonferroni para comparações múltiplas (30 correlações: p= 0,002; 10 correlações: p= 0,005). Os dados relativos ao peso e estatura para a idade foram digitados e analisados no programa específico do EpiInfo que utiliza o padrão NCHS (EpiNut). Resultados – Houve leve predomínio do sexo masculino (54%), predominância de idade inferior a quatro meses (61,3%), prevalência maior nos meses de junho e julho, freqüência elevada de história de prematuridade (23%) e de baixo peso de nascimento (14%). As manifestações clínicas prévias à hospitalização (falta de ar, chiado no peito, febre e parar de respirar) ocorreram, na sua maioria, nos três dias anteriores. Da população estudada, 45% tinha história de sibilância prévia, a maioria com um ou dois episódios relatados (31,5%). Esses pacientes foram analisados separadamente e tiveram resultados semelhantes ao grupo com BVA. A freqüência de desnutrição moderada e grave, excluídos os pacientes com história de prematuridade, foi de 26 pacientes (23%). Todos os pacientes utilizaram broncodilatador inalatório; 20% do grupo com BVA receberam corticosteróides sistêmicos e 47% de toda população, antibióticos. A mediana do uso de oxigênio em pacientes com BVA foi de 4,4 dias (IIQ 70,2-165,2) e o tempo de oxigenoterapia até saturar 95% em ar ambiente foi de 3,4 dias (IIQ 55-128). A mediana do tempo de internação hospitalar foi de 7 dias (IIQ 5-10,5) entre os pacientes com BVA; neste aspecto, apresentou diferença (p = 0,041) em relação ao grupo com sibilância prévia, que teve um tempo de internação mais longo (9 dias, IIQ 5-12). Observou-se pouca variabilidade clínica no período estudado, através da aplicação do escore clínico. Não se encontraram correlações estatisticamente significativas entre os escores clínicos e os TDs com os desfechos. Conclusões – Os TDs como elementos auxiliares na avaliação de pacientes em oxigenoterapia não foram clinicamente úteis neste estudo. É possível, no entanto, que, avaliando pacientes com maiores diferenças clínicas entre si, essas aferições possam mostrar-se importantes.
Resumo:
Objective To compare results reported for blood gas partial pressures, electrolyte concentrations, and Hct in venous blood samples collected from cattle, horses, and sheep and analyzed by use of a portable clinical analyzer (PCA) and reference analyzer (RA).Animals-Clinically normal animals (24 cattle, 22 horses, and 22 sheep).Procedures-pH; Pco(2); Po(2); total carbon dioxide concentration; oxygen saturation; base excess; concentrations of HCO(3)(-), Na(+), K(+), and ionized calcium; Hct; and hemoglobin concentration were determined with a PCA. Results were compared with those obtained for the same blood sample with an RA. Bias (mean difference) and variability (95% confidence interval) were determined for all data reported. Data were also subjected to analyses by Deming regression and Pearson correlation.Results-Analysis of Bland-Altman plots revealed good agreement between results obtained with the PCA and those obtained with the RA for pH and total carbon dioxide concentration in cattle, K(+) concentration in horses and sheep, and base excess in horses. Except for Na(+) concentration and Hct in horses and sheep, correlation was good or excellent for most variables reported.Conclusions and Clinical Relevance-Data from blood gas and electrolyte analyses obtained by use of the PCA can be used to evaluate the health status of cattle, horses, and sheep. Furthermore, the handheld PCA device may have a great advantage over the RA device as a result of the ability to analyze blood samples on farms that may be located far from urban centers. (Am J Vet Res 2010;71:515-521)
Resumo:
OBJETIVO: Comparar a formação de shunt venoso-arterial em pulmões de cães submetidos a anestesia geral inalatória utilizando-se sistemas de anestesia com e sem reinalação, com fração inspirada de oxigênio de 0,4 e 0,9, respectivamente. MÉTODOS: Empregaram-se 20 cães induzidos com tiopental sódico (30mg/kg) e mantidos com sevoflurano (3%) e alocados em dois grupos (n=10); os animais de GI foram ventilados com modalidade controlada em sistema semifechado, sem reinalação, F I O2 = 0,9, e os de GII, com modalidade controlada, sistema semifechado, com reinalação e F I O2 = 0,4. Os atributos analisados durante o experimento foram: freqüência cardíaca, pressão arterial média, shunt pulmonar venoso-arterial, hematócrito, hemoglobina, pressão parcial de oxigênio arterial, pressão parcial de oxigênio no sangue venoso misto, saturação de oxigênio no sangue venoso misto, pressão parcial de dióxido de carbono arterial e pressão de vapor de água nos alvéolos (P VA). RESULTADOS: A P VA foi significativamente maior em GII. A análise estatística dos valores encontrados de shunt mostrou que GI e GII apresentaram diferenças significativas, sendo que os resultados de GI são maiores que os de GII em todos os momentos avaliados. Já a análise de momentos dentro de um mesmo grupo não demonstrou diferenças. CONCLUSÃO: O sistema de anestesia sem reinalação com F I O2 = 0,9 desenvolveu maior grau de shunt pulmonar venoso-arterial que o sistema de anestesia com reinalação e F I O2 = 0,4. A umidificação dos gases em GII contribuiu para diminuir o shunt.
Resumo:
The caprine oxyhemoglobin dissociation curve has not been previously defined. Blood from 10 healthy goats was equilibrated in a tonometer with calibrated gas mixtures of oxygen at concentrations of 95%, 21%, 13%, 12%, 10%, 9%, 8%, 5%, 4% and 2.5%, 5% carbon dioxide, balance nitrogen. The pH, partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), total hemoglobin, oxyhemoglobin saturation, carboxyhemoglobin, methemoglobin, and oxygen content were measured. The PO2/oxyhemoglobin and the PO2/oxygen content relationships were graphed with curve-fitting software and a formula for calculating oxyhemoglobin from PO2 was generated. The maximum oxygen content per gram of hemoglobin was 1.29 ml of oxygen per gram of hemoglobin. The PO2 at which hemoglobin was 50% saturated (P-50) from the PO2/oxyhemoglobin relationship was 28.6 +/- 1.5 mmHg and that from the PO2/oxygen content relationships was 29.1 +/- 1.6 mmHg. The Hill coefficient for the PO2/oxyhemoglobin data was 3.0 +/- 0.4. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Objectives: To evaluate the effects of a combination of tiletamine-zolazepam-romifidine-atropine in ocelots. Design: Prospective experimental trial. Animals: Eight captive adult ocelots (three females and five males). Methods: Calculated doses of tiletamine-zolazepam (3.75 mg kg -1), romifidine (50 μg kg-1) and atropine (0.04 mg kg-1) were administered intramuscularly. After immobilization, animals were weighed and the real doses determined. Heart rate, respiratory frequency, noninvasive systolic, diastolic, and mean arterial pressure, arterial oxygen hemoglobin saturation, and rectal temperature were measured. Data were analyzed by means of ANOVA for repeated measures, followed by the Tukey test to compare values over time. Results: Doses administered were 3.4 ± 0.6 mg kg-1 of tiletamine-zolazepam, 0.04 ± 7.0 mg kg-1 of romifidine, and 0.03 ± 0.007 mg kg-1 of atropine. The mean time to recumbency and duration of immobilization were 7.0 ± 4.5 and 109.2 ± 27.9 minutes, respectively. The median times to standing and walking were 52.3 [0-90] and 2.3 [0-69.3] minutes, respectively. A decrease in heart rate was observed 45 minutes following drug administration. Arterial blood pressure was maintained during the study. Conclusions and clinical relevance: This protocol produced good immobilization in ocelots with minimal changes over time in cardiovascular parameters.