951 resultados para Green performance


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The main light-harvesting chlorophyll a/b -protein complex (LHC II) has been isolated directly from thylakoid membranes of shiphonous green alga, Bryopsis corticulans Setch. by using two consecutive runs of anion exchange and gel-filtration chromatography. Monomeric and trimeric subcomplexes of LHC 11 were obtained by using sucrose gradient ultracentrifugation. Pigment analysis by reversed-phase high performance liquid chromatography showed that chlorophyll a (Chl a), chlorophyll b (Chl b), neoxanthin, violaxanthin and siphonaxanthin were involved in LHC 11 from B. corticulans. The properties of electronic transition of monomeric LHC II showed similarities to those of trimeric LHC II. Circular dichroism spectroscopy showed that strong intramolecular interaction of excitonic dipoles between Chl a and between Chl b exist in one LHC II apoprotein, while the intermolecular interaction of these dipoles can be intensified in the trimeric structure. The monomer has high efficient energy transfer from Chl b and siphonaxanthin to Chl a similarly to that of the trimer. Our results suggest that in B. corticulans, LHC II monomer has high ordered pigment organization that play effective physiological function as the trimer, and thus it might be also a functional organization existing in thylakoid membrane of B. corticulans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A gradient reversed-phase high-performance liquid chromatography (HPLC) method using a C30 column was developed for the simultaneous determination of astaxanthin, astaxanthin monoesters and astaxanthin diesters in the green algae Chlorococcum sp., Chlorella zofingiensis, Haematococcus pluvialis and the mutant E1, which was obtained from the mutagenesis of H. pluvialis by exposure to UV-irradiation and ethyl methanesulphonate (EMS) with subsequent screening using nicotine. The results showed that the contents of total astaxanthins including free astaxanthin and astaxanthin esters ranged from 1.4 to 30.9 mg/g dry biomass in these green algae. The lower total astaxanthin levels (< 2 mg/g dry biomass) were detected in the green algae Chlorococcum sp. and C. zofingiensis. The higher total astaxanthin levels (> 16 mg/g dry biomass) were found in the green alga H. pluvialis and its mutant E1. It is notable that the mutant E1 is found to have considerably higher amounts of total astaxanthin (30.9 mg/g) as compared to the wild strain of H. pluvialis (16.1 mg/g). This indicates that UV-irradiation and EMS compound mutagenesis with subsequent screening using nicotine is an effective method for breeding of a high-producing astaxanthin strain of H. pluvialis. In addition, the green alga C. zofingiensis had a remarkably higher percentage of astaxanthin diesters (76.3% of total astaxanthins) and a remarkably lower percentage of astaxanthin monoesters (18.0% of total astaxanthins) in comparison with H. pluvialis (35.5% for diesters and 60.9% for monoesters), the mutant E1 (49.1% and 48.1%) and Chlorococcum sp. (18.0% and 58.6%).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brian Huntley, Rhys E. Green, Yvonne C. Collingham, Jane K. Hill, Stephen G. Willis , Patrick J. Bartlein, Wolfgang Cramer, Ward J. M. Hagemeijer and Christopher J. Thomas (2004). The performance of models relating species geographical distributions to climate is independent of trophic level. Ecology Letters, 7(5), 417-426. Sponsorship: NERC (awards: GR9/3016, GR9/04270, GR3/12542, NER/F/S/2000/00166) / RSPB RAE2008

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Political drivers such as the Kyoto protocol, the EU Energy Performance of Buildings Directive and the Energy end use and Services Directive have been implemented in response to an identified need for a reduction in human related CO2 emissions. Buildings account for a significant portion of global CO2 emissions, approximately 25-30%, and it is widely acknowledged by industry and research organisations that they operate inefficiently. In parallel, unsatisfactory indoor environmental conditions have proven to negatively impact occupant productivity. Legislative drivers and client education are seen as the key motivating factors for an improvement in the holistic environmental and energy performance of a building. A symbiotic relationship exists between building indoor environmental conditions and building energy consumption. However traditional Building Management Systems and Energy Management Systems treat these separately. Conventional performance analysis compares building energy consumption with a previously recorded value or with the consumption of a similar building and does not recognise the fact that all buildings are unique. Therefore what is required is a new framework which incorporates performance comparison against a theoretical building specific ideal benchmark. Traditionally Energy Managers, who work at the operational level of organisations with respect to building performance, do not have access to ideal performance benchmark information and as a result cannot optimally operate buildings. This thesis systematically defines Holistic Environmental and Energy Management and specifies the Scenario Modelling Technique which in turn uses an ideal performance benchmark. The holistic technique uses quantified expressions of building performance and by doing so enables the profiled Energy Manager to visualise his actions and the downstream consequences of his actions in the context of overall building operation. The Ideal Building Framework facilitates the use of this technique by acting as a Building Life Cycle (BLC) data repository through which ideal building performance benchmarks are systematically structured and stored in parallel with actual performance data. The Ideal Building Framework utilises transformed data in the form of the Ideal Set of Performance Objectives and Metrics which are capable of defining the performance of any building at any stage of the BLC. It is proposed that the union of Scenario Models for an individual building would result in a building specific Combination of Performance Metrics which would in turn be stored in the BLC data repository. The Ideal Data Set underpins the Ideal Set of Performance Objectives and Metrics and is the set of measurements required to monitor the performance of the Ideal Building. A Model View describes the unique building specific data relevant to a particular project stakeholder. The energy management data and information exchange requirements that underlie a Model View implementation are detailed and incorporate traditional and proposed energy management. This thesis also specifies the Model View Methodology which complements the Ideal Building Framework. The developed Model View and Rule Set methodology process utilises stakeholder specific rule sets to define stakeholder pertinent environmental and energy performance data. This generic process further enables each stakeholder to define the resolution of data desired. For example, basic, intermediate or detailed. The Model View methodology is applicable for all project stakeholders, each requiring its own customised rule set. Two rule sets are defined in detail, the Energy Manager rule set and the LEED Accreditor rule set. This particular measurement generation process accompanied by defined View would filter and expedite data access for all stakeholders involved in building performance. Information presentation is critical for effective use of the data provided by the Ideal Building Framework and the Energy Management View definition. The specifications for a customised Information Delivery Tool account for the established profile of Energy Managers and best practice user interface design. Components of the developed tool could also be used by Facility Managers working at the tactical and strategic levels of organisations. Informed decision making is made possible through specified decision assistance processes which incorporate the Scenario Modelling and Benchmarking techniques, the Ideal Building Framework, the Energy Manager Model View, the Information Delivery Tool and the established profile of Energy Managers. The Model View and Rule Set Methodology is effectively demonstrated on an appropriate mixed use existing ‘green’ building, the Environmental Research Institute at University College Cork, using the Energy Management and LEED rule sets. Informed Decision Making is also demonstrated using a prototype scenario for the demonstration building.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gabriel Urbain Fauré lived during one of the most exciting times in music history. Spanning a life of 79 years (1845-1924), he lived through the height of Romanticism and the experimental avant-garde techniques of the early 20th century. In Fauré's music, one can find traces of Chopin, Liszt, Mendelssohn, Debussy and Poulenc. One can even argue that Fauré presages Skryabin and Shostakovich. The late works of Gabriel Fauré, chiefly those composed after 1892, testify to the argument that Fauré holds an important position in the shift from tonal to atonal composition and should be counted among such transitional composers as Gustav Mahler, Claude Debussy, Erik Satie, Richard Strauss, and Ferruccio Busoni. Fauré's unique way of fashioning harmonic impetus of almost purely linear means, resulting in a synthesis of harmonic and melodic devices, led me to craft the term mélodoharmonique. This term refers to a contrapuntally motivated technique of composition, particularly in a secondary layer of musical texture, in which a component of harmonic progression (i.e. arpeggiation, broken chord, etc.) is fused with linear motivic or thematic development. This dissertation seeks to bring to public attention through exploration in lecture and recital format, certain works of Gabriel Fauré, written after 1892. The repertoire will be selected from works for solo piano and piano in collaboration with violin, violoncello, and voice, which support the notion of Fauré as a modernist deserving larger recognition for his influence in the transition to atonal music. The recital repertoire includes the following--Song Cycles: La bonne chanson, opus 61; La chanson d'Ève, opus 95; Le jardin clos, opus 106; Mirages, opus 113; L'horizon chimérique, opus 118; Piano Works: Prelude in G minor opus 103, No. 3; Prelude in E minor opus 103, No. 9; Eleventh Nocturne, opus 104, No.1; Thirteenth Nocturne, opus 119; Chamber Works: Second Violin Sonata, opus 108; First Violoncello Sonata, opus 109; Second Violoncello Sonata, opus 117.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Green roofs are one solution to stormwater runoff which is a major environmental problem. However, the majority of green roofs are primarily implemented on flat roofed commercial buildings and not residential homes with sloped roofs. Team SO GREEN designed a light-weight green roof system retrofit for residential homes. Between June and November 2014, green roof performance data was collected and compared between the designed sloped roofs and a non-sloped control. The sloped design performed well and one test slope was improved with a recirculating irrigation system. An economic analysis was made and a focus group determined preliminary consumer interest, aesthetic preferences, and barriers. This study enriches the body of knowledge regarding bringing green roof systems to the residential home market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The purpose of this paper is to examine the extent and nature of greening the supply chain (SC) in the UK manufacturing sector; and the factors that influence the breadth and depth of this activity.

Design/methodology/approach: Based on the findings from a sample of manufacturing organisations drawn from the membership of The Chartered Institute for Purchasing and Supply. Data are collected using a questionnaire, piloted and pre-tested before distribution with responses from 60 manufacturing companies.

Findings: On average manufacturers perceive the greatest pressure to improve environmental performance through legislation and internal drivers (IDs). The least influential pressures are related to societal drivers and SC pressures from individual customers. Green supply chain management (GSCM) practices amongst this “average” group of UK manufacturing organisations are focusing on internal, higher risk, descriptive activities, rather than proactive, external engagement processes. Environmental attitude (EA) is a key predictor of GSCM activity and those organisations that have a progressive attitude are also operationally very active. EA shows some relationship to legislative drivers but other factors are also influential. Operational activity may also be moderated by organisational contingencies such as risk, size, and nationality.

Research limitations/implications: The main limitation to this paper is the relatively small manufacturing sample.

Practical implications: This paper presents a series of constructs that identify GSCM operational activities companies to benchmark themselves against. It suggests which factors are driving these operational changes and how industry contingencies may be influential.

Originality/value: This paper explores what is driving environmental behaviour amongst an “average” sample of manufacturers, what specific management practices take place and the relationships between them.

Keywords: Manufacturing industries, Environmental management, Supply chain management, Sustainable development, United Kingdom
Paper type: Research paper

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A six-part radio comedy series, co-writeen with John Murphy, set in the insane world of the Circuit Court in the Republic of Ireland. The series was broadcast by RTE Lyric FM.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Green tea, a popular polyphenol-containing beverage, has been shown to alleviate clinical features of the metabolic syndrome. However, its effects in endogenous antioxidant biomarkers are not clearly understood. Thus, we tested the hypothesis that green tea supplementation will upregulate antioxidant parameters (enzymatic and nonenzymatic) in adults with the metabolic syndrome. Thirty-five obese participants with the metabolic syndrome were randomly assigned to receive one of the following for 8 weeks: green tea (4 cups per day), control (4 cups water per day), or green tea extract (2 capsules and 4 cups water per day). Blood samples and dietary information were collected at baseline (0 week) and 8 weeks of the study. Circulating carotenoids (a-carotene, ß-carotene, lycopene) and tocopherols (a-tocopherol, ?-tocopherol) and trace elements were measured using high-performance liquid chromatography and inductively coupled plasma mass spectroscopy, respectively. Serum antioxidant enzymes (glutathione peroxidase, glutathione, catalase) and plasma antioxidant capacity were measured spectrophotometrically. Green tea beverage and green tea extract significantly increased plasma antioxidant capacity (1.5 to 2.3 µmol/L and 1.2 to 2.5 µmol/L, respectively; P <.05) and whole blood glutathione (1783 to 2395 µg/g hemoglobin and 1905 to 2751 µg/g hemoglobin, respectively; P <.05) vs controls at 8 weeks. No effects were noted in serum levels of carotenoids and tocopherols and glutathione peroxidase and catalase activities. Green tea extract significantly reduced plasma iron vs baseline (128 to 92 µg/dL, P <.02), whereas copper, zinc, and selenium were not affected. These results support the hypothesis that green tea may provide antioxidant protection in the metabolic syndrome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Implementation of both design for durability and performance-based standards and specifications are limited by the lack of rapid, simple, science-based test methods for characterizing the transport properties and deterioration resistance of concrete. To this end, this paper presents the background rationale and current developments in the application of electrical property measurements - conductivity in this instance - as a testing methodology to evaluate the relative performance of a range of concrete mixes. The technique can not only be used on standard specimens (e.g. cubes), but also lends itself to in-situ monitoring thereby allowing measurements to be obtained on the as-placed concrete. It is the latter which forms the focus of the current work. Conductivity measurements are presented for concretes with and without supplementary cementitious materials (SCM's) from demoulding up to 400-days. It is shown that electrical conductivity measurements display a continual decrease over the entire test period and attributed to the pore structure refinement due to hydration and pozzolanic reaction in those concretes containing blast furnace slag or fly ash. The term Formation Factor is introduced to rank concrete performance in terms of is resistance to chloride penetration.